09-667R-004
ELECTRICAL GENERAL NOTES NOTES 1.- AC SHALL HAVE BUILT -IN BREAKER. 2.- ALL SINGLE STATION SMOKE DETECTOR WITHIN THE HOUSE SHALL ME INTERCONNECTED AS PER NFPA 32 ART. 8- 1.4.1.6 3.- ALL SINGLE STATION SMOKE DETECTOR SHALL BE POWERED BY 120V POWER AND SHALL BE CONNECTED TO BRANCH CIRCUIT AHEAD OF ANY SWITCH, 4.- ALL SINGLE STATION SMOKE DETECTOR SHALL HAVE BATTERY BACK -UP. 5.- ALL SINGLE STATION SMOKE DETECTORS SHALL BE INSTALLED MIN 3' FROM ANY A/C REGISTER, BATHROOM OR KITCHEN DOOR. CONTRACTOR TO VERIFY IN FIELD. 6.- COORDINATE EXACT LOCATION OF ALL DEVICES WITH ARCH /OWNER. T- HANGING FIXTURES L FANS MUST BE SUPPORTED AS PER NEC 314- 23D/422 -18. 8.- JACUZZI SHALL HAVE AN ACCESS PLATE OR COVER AS PER NEC 680 -73. MIN SIZE 20 "W x 15 "H. ALL METAL PIPING SYSTEM, METAL PARTS OF ELECTRIC EQUIPMENTS, AND PUMP MOTORS ASSOCIATED WITH THE JACUZZI SHALL BE BONDED TOGETHER WITH A COPPER BONDING JUMPER, INSULATED, COVERED, OR MARE, NOT SMALLER THAN #8 AWG SOLID, AS PER NEC 680 -74. 9.- FIXTURES LOCATED IN WET LOCATIONS SHALL BE LISTED FOR THAT PURPOSE. 10.- CONTRACTOR TO PROVIDE PANEL SCHEDULE AT EACH PANEL INDICATING ALL CKTS CONNECTED. 11.- CONTRACTOR SHALL LABEL PANELS AND DISCONNECT . EX: PANEL "A ", PANEL "A" DISCONNECT ETC. 12,- FIXTURES WITH DIRECT CONTACT W /INSULATION MUST ME RATED IC AS PER NEC 410 -65 (C). 13. -ALL FLUORESCENT FIXTURES MUST ME ENERGY EFFICIENT. ALL CEILING FIXTURES MUST HAVE AN IN LINE FUSE (THERMAL PROTECTOR). 14. -ALL LIGHTING FIXTURES MUST ME LISTED BY A NATIONAL RECOGNIZED TESTING LABORATORY (UL) A/C CALCULATIONS 240V -10 CENTRAL A /C#1 COMPRESSOR: 19.9 AMP HEATER: 9,600 VA CONDENSER FAN: 2,8 AMP EVAP. BLOWER: 4.3 AMP EVAP. BLOWER: 43A x 240V = 1,032 VA 27,0 AMP TOTAL VA = 28.0 A x 240 V = 6,480 VA TOTAL HEATER = 10,632 VA SELECT LARGER NON CONCURRENT A/C LOAD: 10,632VA EXISTING SERVICE - TO FPSL POLE NEUTRAL TO BE BONDED IN MAIN AS PER NEC 250.24(8), 250.26, 250.28. NEW METER /COMBO - 200A, 10, 120/240V ELECTRICAL RISER DIAGRAM LEGEND O (3) #2/0 THWN CU IN 2" PVC CONDUIT ©(3) #2/0 THWN CU L (1) #6 THWN GROUND IN 2" PVC CONDUIT (3) #4 THWN CU L (1) #8 THWN GROUND IN 1 -1/2" PVC CONDUIT WWVV YVV 1.- OVERALL INSTALLATION: THE INSTALLATION SHALL COMPLY WITH THE NATIONAL 11.- DATA /TELECOMMUNICATION SYSTEMS: FOR DATA /TELECOMMUNICATION SYSTEMS 24. -ALL ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN ACCESIBLE AREAS ONLY • G G ELECTRICAL CODE (NEC), THE FLORIDA 11111;UILDING CODE (FBC), AND ANY OTHER UTILIZE A CONTRACTOR EXPERIENCED IN THE INSTALLATION OF AND ABOVE BASE FLOOD ELEVATION. w•• V V APPLICABLE FEDERAL, STATE AND LOCAL CODES. COMMUNICATIONSYSTEMS AND CERTIFIED BY BUILDING INDUSTRY CONSULTING SERVICE INTERNATIONAL, 25.- CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER AND FUSES • Y Y 2.- CONDUCTOR CALCULATIONS: CONDUCTOR CALCULATIONS ARE BASED ON 75•C. 12- CUTTING AND PATCHING: MAJOR CUTTING, PATCHING 14 PAINTING REQUIRED BY SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATES, IF DIFFERENT FROM THOSE SPECIFIED ON DRAWINGS, AS WELL AS ANY FEEDER CHANGES BEING AFFECTED BY J, THE GENERAL AND SPECIAL CONDITIONS AND REQUIREMENTS OF THE THIS CONTRACT WILL BE PERFORMED IN A NEAT AND WORKMANLIKE MANNER. ALL THIS CHANGE. CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA *00 Y• V • 3.- GENERAL: CONTRACT AND SPECIFICATIONS AS WELL AS PLANS AND SPECIFICATIONS OF OTHER SURFACES SHALL BE RETURNED TO ORIGINAL CONDITIONS AFTER THE INSTALLATION COST. EXECUTED FROM THESE PLANS WITHOUT EXPRESSED APPROVAL OF THE DESIGN PROFESSIONAL CONSULTING DISCIPLINES AND TRADES SHALL BE A PART OF THE WORK HEREBY SPECIFIED. THESE OF THE EQUIPMENT. 26.- ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR TO information provided by others. SPECIFICATIONS AND ACCOMPANYING PLANS ARE INTENDED TO PROVIDE FOR THE FURNISHING AND INSTALLATION OF THE ELECTRICAL SYSTEMS. TO PROVIDE 13. -THE ELECTRICAL INSTALLATION SHALL MEET ALL STANDARD REQUIREMENTS OF PROVIDE ALL REQUIRED J -BOXES AND CONDUITS FOR INSTALLATION OF CONTROL V Y V Y G COMPLETE THE LOCAL ELECTRIC UTILITY AND THE TELEPHONE COMPANY, WIRING. LOW VOLTAGE CONTROL WIRING AND THEIR TERMINATION IS THE V • G ti MEANS TO FURNISH AND INSTALL. • RESPONSIBILITY OF THE MECHANICAL CONTRACTOR, 4•u u 4.- COMPLIANCE: WORKMANSHIP, MATERIALS AND INSTALLATION SHALL BE IN STRICT 14. -LOAD DATA IS BASED ON INFORMATION PROVIDED TO THE ENGINEER AT THE TIME OF DESIGN. ALL EQUIPMENT AND PANEL SIZES SHALL BE VERIFIED BEFORE ORDERING, 23.- ELECTRICAL METER AND PANEL LOCATIONS SHOWN MAY VARY DEPENDING ON ♦v ACCORDANCE WITH THE APPLICABLE EDITION OF THE NEC, NFPA, NEMA, ASTM, OSHA, • SERVICE ENTRANCE LOCATION, ••Y• ••••• HRS HEALTH AGENCIES, AND OTHER APPLICABLE NATIONAL, STATE, AND LOCAL AND PERTAINING REGULATIONS ESTABLISHED BY THE RULING AUTHORITY 15.- CIRCUITS SHOWN ON PLANS ARE USED TO DETERMINE LOAD DATA AND PANEL • • ♦♦• • ti CODES HAVING JURISDICTION. CONTRACTORS SHALL ALSO MEET THE REQUIREMENTS OF SIZES. THE CONTRACTOR SHALL PROVIDE CIRCUIT ROUTING TO SUIT THE JOB 28. -ALL LIGHTING FIXTURES 70 BE SELECTED BY THE OWNER /ARCHITECT, U.O.N. AND OTHER STANDARDS WHERE SUCH REQUIREMENTS ARE MORE STRICT THAN THOSE CONDITIONS. SHALL BE INSTALLED BY THIS CONTRACTOR. T STANDARDS CITED ABOVE. 16.- FURNISH AND INSTALL ALL FIXTURES AS CALLED FOR ON THE PLANS OR AS 29.- BALANCE ALL PHASES AT EACH PANEL AND MOP/SERVICE MAINS. ISOLATED S.- WORKMANSHIP: ALL WORK SHALL BE PERFORMED BY CONTRACTORS LICENSED IN SELECTED BY OWNER /ARCHITECT. 30. -CHECK AVAILABLE ELECTRICAL SERVICE CHARACTERISTICS WITH THE LOCAL :00 DO • ••••w THEIR RESPECTIVE DISCIPLINE. WORK SHALL BE DONE IN A FIRST CLASS MANNER, TO THE ACCEPTANCE OF THE ARCHITECT AND THE 13.- MINIMUM WIRE SIZE SHALL BE #14 AWG. UNLESS OTHERWISE NOTED, ALL POWER COMPANY PRIOR TO ORDERING ANY EQUIPMENT. INFORM THE ARCH /ENGINEER FULLY OPERATIVE, AND ENGINEERS, CONTRACTOR SHALL PROVIDE FOR ALL NECESSARY LABOR AND MATERIAL CONDUCTORS SHALL BE COPPER WITH THHN /THWN INSULATION, CONDUCTORS #10 AND IF IT IS DIFFERENT FROM WHAT IS SHOWN ON PLANS. BREAKER,AS PER NEC 240 - 83(0). REQUIRED FOR THE COMPLETION OF THE WORK INCLUDING BUT NOT LIMITED TO SMALLER MAY ME SOLID; #8 AND LARGER SHALL BE STRANDED ALUMINUM CONDUCTORS MAY BE ALLOWED FOR SERVICE ENTRANCE IF SPECIFICALLY APPROVED 31.- CONTRACTOR SHALL PROVIDE TEMPORARY SERVICE AND LIGHTING FOR USE OF WITH RELATED WORK SUCH AS CONNECTION OF EXISTING SYSTEMS, EXCAVATIONS AND NY THE ENGINEER. ALL TRADES AS REQUIRED FOR CONSTRUCTION AND AUTHORITIES HAVING RACK FILLING. JURISDICTION. 6,- MATERIALS: CONTRACTOR SHALL PROVIDE ALL NEW MATERIALS OF AMERICAN 18. -ALL CONDUCTORS SHALL BE RUN IN CONDUIT, U.O.N, 32,- ELECTRICAL CONTRACTOR SHALL ASSURE THAT ALL FEATURES OF SERVICE MANUFACTURE, BEARING THE UNDERWRITER'S LABORATORY (UL) LABEL AS FOR THE APPLICATION AND 19.- INSTALL 3/4" EMPTY CONDUIT TO ALL TELEPHONE /DATA OUTLETS. PROVIDE PULL COMPLY WITH THE POWER COMPANY'S REQUIREMENTS AND SHALL MAKE ALL VA APPLICABLE, MATERIALS SHALL BE NEW, SUITABLE WIRE. NECESSARY ARRANGEMENTS WITH POWER COMPANY FOR SERVICE, ALL EQUIPMENT VOLT ABOVE STANDARD QUALITY NORMALLY USED FOR THE PURPOSE AS CALLED FOR ON WIRE NOT FURNISHED AND /OR INSTALLED by THE POWER CO. IS TO BE FURNISHED AND VA PLANS. SUPPLEMENTAL MATERIALS, PRODUCTS AND COMPONENTS NECESSARY TO COMPLY WITH THE INTENT OF THE CONTRACT DRAWINGS AND /OR SPECIFICATIONS, 20. -ALL CONDUITS SHALL BE GALVANIZED RIGID (GRU, EXCEPT AS FOLLOWS: INSTALLED BY THE ELECTRICAL CONTRACTOR. SPEC BUT NOT NOTED OR SPECIFIED ON THESE SECTIONS, SHALL BE PROVIDED BY THE CONTRACTOR AS REQUIRED FOR THE COMPLETION OF THE WORK AT NO ADDITIONAL (A) UL LISTED PVC CONDUITS MAY BE USED UNDERGROUND OUTDOORS OR 33.- U.O.N., COORDINATE REQUIRED A.I.C. RATINGS WITH POWER COMPANY. CONE COST TO THE OWNER. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVISIONS AND UNDER SLAB INSIDE THE BUILDING AS ALLOWED BY CODE. CONDUIT FITTINGS AND CEMENT SHALL BE PRODUCED BY THE SAME MANUFACTURER. 34. -WHERE MORE THAN ONE IS INDICATED AT ANY LOCATION, THESE SHALL USE COORDINATION OF DELIVERY OF MATERIALS. EQUIPMENT MARRED DURING SHIPMENT OR ME GANGED UNDER ONE COMMOON N COVER. AWG INSTALLATION SHALL RE TOUCHED UP AND REFINISHED TO FACTORY FINISH, (B) ELECTRICAL METALIC TUBING (EMT), MAY BE USED IN OR ON WALLS OR No. REPLACED WHERE NOT ACCEPTABLE. CEILINGS WHERE NOT SUBJECT TO MECHANICAL DAMAGE, CORROSIVE OR DAMP 35.- QUANTITY AND LOCATION OF ELECTRICAL, TELEPHONE /DATA iG TV OUTLETS, AWG 7.- PERMITS AND INSURANCE: CONTRACTOR SHALL SECURE AND PAY FOR ALL CONDITIONS. LIGHTS AND LIGHT CONTROLS, SHALL BE ADJUSTED TO SUIT THE OWNER'S REQUIREMENTS AS PER OWNER /ARCHITECT INSTRUCTIONS. SAID ARRANGEMENTS AHU -1 PERMITS, FEES, TAXES, INSPECTIONS, TESTS, FINES AND OTHER ITEMS AS REQUIRED FOR THE INSTALLATION OF THE COMPLETE ELECTRICAL SYSTEMS AS OUTLINED HEREIN (C) ELECTRICAL NON METALIC TUBING (ENT), MAY BE USED WHEN INSTALLED IN SHALL NOT BE IN CONFLICT WITH APPLICABLE CODES. 6 AND SHOWN ON PLANS. CONTRACTOR SHALL PROVIDE ALL REQUIRED INSURANCE FOR ACCORDANCE WITH THE REQUIREMENTS OF THE NEC ARTICLE 362 AND ONOUIT CONTRACTOR SHALL VERIFY REQUIREMENTS, EXACT LOCATIONS, TYPE PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION MANUFACTURER'S INSTRUCTIONS, AND ARRANGEMENT OF OUTLETS FOR ALL ELECTRICAL FIXTURES, APPLIANCES AND AND ARRANGEMENT 240 OF THE WORK. (0) METAL CLAD CABLE (MC), SHALL BE LIMITED TO BRANCH CIRCUITING AND BE EQUIPMENT, PRIOR TO INSTALLATION. 11,500 a,- EXISTING CONDITIONS: BEFORE BIDDING, THE CONTRACTOR SHALL VISIT THE JOB INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF NEC ARTICLE 330 AND CABLE ALL BRANCH CIRCUITS THAT SUPPLY 125 - VOLTS, SINGLE PHASE, 15 AND 20 SITE AND ASCERTAIN ALL EXISTING CONDITIONS WHICH WILL AFFECT HIS WORK. MANUFACTURER'S INSTRUCTIONS. AMPERE OUTLETS INSTALLED IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED MY AM FAILURE TO DO SO WILL NOT BE ACCEPTED AS A REASON FOR REQUESTING EXTRA PAY WHERE THE EXISTING CONDITIONS RESULT IN EXTRA MATERIALS OR ANY (E) NONMETALLIC CABLE (NM), (NMC) L (NMS) MAY BE USED FOR INTERIOR N ARC -FAULT CIRCUIT INTERRUPTER (AFCI) LISTED TO PROVIDE PROTECTION OF THE EXISTING CONDITIONS FOUND BY THE CONTRACTOR WHICH WILL ADVERSELY AFFECT WIRING, EXPOSED OR CONCEALED IN DRY LOCATIONS. MUST NOT BE USED EMBEDDED ENTIRE BRANCH CIRCUIT. E THE WORK SHALL BE IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE IN CONCRETE, MASONRY, FILL OR PLASTER. ITS USE AND INSTALLATION SHALL INSTALLATION OF LIGHTING FIXTURES INSIDE CLOTHES CLOSETS SHALL COMPLY ARCHITECT /ENGINEER, CORRECTION OF ANY DEFECTS SHALL BE COMPLETELY WITHOUT COMPLY WITH NEC ARTICLE 334. WITH THE NEC ARTICLE 410 -8. WITH ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENTS OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY. (F) FLEXIBLE CONDUIT SHALL BE USED FOR CONNECTIONS TO VIBRATING 39.- PROVIDE A TYPEWRITTEN DIRECTORY FOR EACH ELECTRICAL PANEL, 240 30 EQUIPMENT AND RECESSED LIGHT FIXTURES, WHERE PERMITTED BY CODE, EMBEDDED 3/4 4,500 9,- SUBSTITUTIONS: PRODUCTS AND MATERIALS CALLED OUT BY TRADE NAME IN CONCRETE, MASONRY, FILL OR PLASTER. IF USED OUTDOORS, IT SHALL BE CONTRACTOR SHALL FURNISH AS -BUILT DRAWINGS TO THE OWNER UPON AND /OR CATALOG NUMBERS ESTABLISH A STANDARD OF QUALITY, APPEARANCE, LIQUIDTIGHT. COMPLETION OF WORK AND PRIOR 70 FINAL PAYMENT. COMPLETION PERFORMANCE AND DIMENSION, CONTRACTORS SHALL BASE HIS PROPOSAL ON THOSE 8 ITEMS AS THEY SHALL BE CONSIDERED AS A STANDARD BASIS OF BIDDING. 21.- PROVIDE FIRE RETARDANT U.L. APPROVED SEALANT ON ALL PENETRATIONS, OUTLET BOXES SHALL PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY REQUESTS FOR SUBSTITUTION SHALL BE SUBMITTED IN WRITING TO THE WALLS AND STRUCTURAL SLABS. IT SHALL BE THE RESPONSIBILITY OF THE WITH THREADED HUBS IN WET /DAMP LOCATIONS AND SPECIAL ENCLOSURES AS WITH T EXIST, COOKTOP ARCHITECT /ENGINEER, DEMONSTRATING THAT PRODUCT IS OF COMPARABLE AND ELECTRICAL CONTRACTOR TO VERIFY, PRIOR TO SUBMITTING BID, THE LOCATIONS OF REQUIRED FOR OTHER CLASSIFIED AREAS AND SHALL CONFORM TO NEMA STANDARDS. EXIST BASIC DESIGN, CONSTRUCTION, STANDARDS AND WARRANTIES, DIMENSIONS TO FIT ALL SUCH FIRE RATED PARTITIONS, WALLS, AND STRUCTURAL SLABS. PLASTIC BOXES MAY BE USED WHERE PERMITTED UNDER APPLICABLE CODES AND WITHOUT CHANGE, AND DOES NOT CAUSE EXTRA WORK TO OTHER TRADES. CLOTHES WASHER J. DRYER ** ORDINANCES. 240 CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING EQUALITY OF SUBSTITUTION: 22,- INTERFERENCE: THE CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER 3/4 6,500 ARCHITECT /ENGINEER WILL, UNDER NO CIRCUMSTANCES, BE REQUIRED TO PROVE SUCH TRADES SO THAT INTERFERENCE WITH EXISTING CONDITIONS, CONDUITS, PIPING, 42 -ALL DISCONNECT SWITCHES SHALL BE SIZED NEC REQUIREMENTS TO ITEM IS OR IS NOT OF EQUAL QUALITY TO THE SPECIFIED ITEM. ARCHITECT /ENGINEER EQUIPMENT, ARCHITECTURAL AND STRUCTURAL MEMBERS BE AVOIDED. R ACCOMODATE THE EQUIPMENT SERVED, INCLUDING REJECTION CLIPS AND FUSES, WHEN EXPENSES INCURRED DUE TO CONTRACTOR'S REQUESTED REVISIONS OR SUBSTITUTIONS SHALL BE PAID BY THE CONTRACTOR. 23.- PLANS: DRAWINGS ARE BASICALLY DIAGRAMS INTENDED TO DEPICT APPLICABLE. SWITCHES SHALL HP RATED, QUICK -MAKE, QUICK - BREAK, IN NEMA 1 APPROXIMATELY EQUIPMENT LOCATIONS AND ARRANGEMENTS, NOT TO SHOW EVERY ENCLOSURES FOR INDOOR AND NEMA 3R FOR OUTDOOR. 10.- MOTORS STARTERS SHALL BE MANUAL OR MAGNETIC AS INDICATED OR REQUIRED, MINOR DETAIL. PLANS SHALL NOT BE SCALED TO DETERMINE EXACT LOCATION AND 13 EXISTING DISHWASHER WITH OVERLOAD RELAYS OR FUSES IN EACH HOT LEG. DIMENSIONS. 20 NOTES 1.- AC SHALL HAVE BUILT -IN BREAKER. 2.- ALL SINGLE STATION SMOKE DETECTOR WITHIN THE HOUSE SHALL ME INTERCONNECTED AS PER NFPA 32 ART. 8- 1.4.1.6 3.- ALL SINGLE STATION SMOKE DETECTOR SHALL BE POWERED BY 120V POWER AND SHALL BE CONNECTED TO BRANCH CIRCUIT AHEAD OF ANY SWITCH, 4.- ALL SINGLE STATION SMOKE DETECTOR SHALL HAVE BATTERY BACK -UP. 5.- ALL SINGLE STATION SMOKE DETECTORS SHALL BE INSTALLED MIN 3' FROM ANY A/C REGISTER, BATHROOM OR KITCHEN DOOR. CONTRACTOR TO VERIFY IN FIELD. 6.- COORDINATE EXACT LOCATION OF ALL DEVICES WITH ARCH /OWNER. T- HANGING FIXTURES L FANS MUST BE SUPPORTED AS PER NEC 314- 23D/422 -18. 8.- JACUZZI SHALL HAVE AN ACCESS PLATE OR COVER AS PER NEC 680 -73. MIN SIZE 20 "W x 15 "H. ALL METAL PIPING SYSTEM, METAL PARTS OF ELECTRIC EQUIPMENTS, AND PUMP MOTORS ASSOCIATED WITH THE JACUZZI SHALL BE BONDED TOGETHER WITH A COPPER BONDING JUMPER, INSULATED, COVERED, OR MARE, NOT SMALLER THAN #8 AWG SOLID, AS PER NEC 680 -74. 9.- FIXTURES LOCATED IN WET LOCATIONS SHALL BE LISTED FOR THAT PURPOSE. 10.- CONTRACTOR TO PROVIDE PANEL SCHEDULE AT EACH PANEL INDICATING ALL CKTS CONNECTED. 11.- CONTRACTOR SHALL LABEL PANELS AND DISCONNECT . EX: PANEL "A ", PANEL "A" DISCONNECT ETC. 12,- FIXTURES WITH DIRECT CONTACT W /INSULATION MUST ME RATED IC AS PER NEC 410 -65 (C). 13. -ALL FLUORESCENT FIXTURES MUST ME ENERGY EFFICIENT. ALL CEILING FIXTURES MUST HAVE AN IN LINE FUSE (THERMAL PROTECTOR). 14. -ALL LIGHTING FIXTURES MUST ME LISTED BY A NATIONAL RECOGNIZED TESTING LABORATORY (UL) A/C CALCULATIONS 240V -10 CENTRAL A /C#1 COMPRESSOR: 19.9 AMP HEATER: 9,600 VA CONDENSER FAN: 2,8 AMP EVAP. BLOWER: 4.3 AMP EVAP. BLOWER: 43A x 240V = 1,032 VA 27,0 AMP TOTAL VA = 28.0 A x 240 V = 6,480 VA TOTAL HEATER = 10,632 VA SELECT LARGER NON CONCURRENT A/C LOAD: 10,632VA EXISTING SERVICE - TO FPSL POLE NEUTRAL TO BE BONDED IN MAIN AS PER NEC 250.24(8), 250.26, 250.28. NEW METER /COMBO - 200A, 10, 120/240V ELECTRICAL RISER DIAGRAM LEGEND O (3) #2/0 THWN CU IN 2" PVC CONDUIT ©(3) #2/0 THWN CU L (1) #6 THWN GROUND IN 2" PVC CONDUIT (3) #4 THWN CU L (1) #8 THWN GROUND IN 1 -1/2" PVC CONDUIT WWVV YVV • Y VWV4W t'4V • G G Y sj ♦ Y V • ♦ w•• V V V • • Y E • • Y Y • • • • w W V V G V G V V V W E u *00 Y• V • G W V V V V E • EXECUTED FROM THESE PLANS WITHOUT EXPRESSED APPROVAL OF THE DESIGN PROFESSIONAL CONSULTING may be incorporated herein as a result of erroneous SHALL AUTOMATICALLY RENDER THE DESIGN PROFESSIONAL AND THE ENGINEERING GROUP, PA, HARMLESS TO ANY LIABILITY CLAIMS, SUIT OR LITIGATION BY ANY INTERESTED PARTIES information provided by others. OF THE PROJECT. NO PART THEREOF OF THESE PLANS SHALL BE CORIED OR REPRODUCED BY ANY MEANS, OR USED IN CONNECTION WITH ANY WORK OTHER THAN FOR THE SPECIFIC PROJECT FOR V Y V Y G V •• • W V V V • G ti ti • V Y V 4•u u DUTY. Y V V' W w ♦v ;04 • Yu• Y ••Y• ••••• C = VIA •• • • ♦♦• • ti ♦ Y Y Y • AFCI = BREAKER SUITABLE FOR ARC -FAULT CKT. PROTECTION INTERRUPTER BKR. T = VIA TIMER. IS = ISOLATED GROUND CKT. :00 DO • ••••w 4 ♦w• ♦ ♦••• V GENERAL LOAD CALCULATIONS As per N.E.0 Art. 220,30 Section B 1,850 sqf x 3 va /sqf = 5,550 va Other Loads = 62,760 va Subtotal = 68,310 va First 10,000 va @ 100% = 10,000 va Rest 51,310 va @ 40% = 23,324 va Subtotal = 33,324 va A/C Load = 10,632 va Total VA = 43,956 va Panel Load = 43,956/240 = 183 Amps KITCHEN 8 0 A[3E]-- 200A PANEL "b" NEW PANEL "A" 120/240V 120/240V 200A,.10 200A, 14 42 POS. U POs. WP 4,--- EXIST TO C,W.P 1 1 EXISTING GROUNDING RODS (CONTRACTOR TO VERIFY) EXISTING ONE STORY CBS GARAGE ( EXISTING I SUB- PANEL I „C„ I 1120/240V I I 125A,10 I 1 12 POS, I L. - - -rJ WP ELECTRICAL RISER DIAGRAM N.T.S. DI NORTH ETER /COMBO 1ANEL 'A') L ERVICE ENTRANCE BEE ELECT. RISER) PHASE: 10 RECORD DRAWINGS PANEL TTBTT PLANS ARE PROTECTED UNDER THE COPYRIGHT LAWS OF FLORIDA: These record drawings have been prepared based VOLTAGE: 120/240 v on the information compiled and provided b p p y CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CDNDITIONS ON THE JOB. THE DESIGN PROFESSIONAL MUST BE NOTIFIED IN WRITING OF ANY VARIATION FROM THE PLANS. others. The engineer has not verified the accuracy ALL IDEAS DESIGN ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWINGS ARE OWNED BY AND THE PROPERTY OF THE DESIGN PROFESSIONAL AND WERE CREATED EVOLVED AND and/or completeness of this information and shall PANEL AMPS: 20OAmps not be responsible for any errors or omissions that EXECUTED FROM THESE PLANS WITHOUT EXPRESSED APPROVAL OF THE DESIGN PROFESSIONAL CONSULTING may be incorporated herein as a result of erroneous SHALL AUTOMATICALLY RENDER THE DESIGN PROFESSIONAL AND THE ENGINEERING GROUP, PA, HARMLESS TO ANY LIABILITY CLAIMS, SUIT OR LITIGATION BY ANY INTERESTED PARTIES information provided by others. OF THE PROJECT. NO PART THEREOF OF THESE PLANS SHALL BE CORIED OR REPRODUCED BY ANY MEANS, OR USED IN CONNECTION WITH ANY WORK OTHER THAN FOR THE SPECIFIC PROJECT FOR HACR = BREAKER SUITABLE FOR THE PROTECTION OF HEATING,A /C AND WHICH THEY HAVE BEEN PREPARED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL LV = VIA LOW VOLTAGE TRANSFORMER. SWO = ON -OFF SWITCHING DUTY. REFRIGERATION EQUIPMENT. C = VIA CONTACTOR. NCL = NON- CONCURRENT LOAD, AFCI = BREAKER SUITABLE FOR ARC -FAULT CKT. PROTECTION INTERRUPTER BKR. T = VIA TIMER. IS = ISOLATED GROUND CKT. GFI = GROUND FAULT INTERRUPTER. HID = RATED BREAKER,AS PER NEC 240 - 83(0). ST = BREAKER WITH SHUNT TRIP, VA Ckt VOLT BKR WIRE CONO VA PHASE Ckt USE SPEC VOLT WIRE CONE A C No. USE SPEC AMP AWG SIZE No. AMP AMP AWG SIZE 1 AHU -1 240 60 6 1 10,032 • 2 NEW WATER HEATER 240 60 6 3/4 11,500 3 • 4 5 6 WATER HEATER 240 30 10 3/4 4,500 T 8 9 EXIST, COOKTOP 240 50 EXIST EXIST 9,600 10 CLOTHES WASHER J. DRYER ** 240 35 >s 3/4 6,500 11 • 12 13 EXISTING DISHWASHER 120 20 EXIST EXIST 1,200 • 14 LAUNDRY CIRCUIT 120 20 12 1/2 1,500 15 EXISTING REFRIGERATOR 120 20 EXIST EXIST 1,200 16 EXIST. BATHROOM RECEPTACLES GFI 120 20 EXIST EXIST 17 EXIST. GARBAGE DISPOSAL /KIT. H000 120 20 EXIST EXIST 1,200 + 1i GENERAL LIGHTS AFCI 120 20 12 1/2 19 EXIST, SMALL APLIANCES GFI 120 20 EXIST EXIST 1,500 20 GENERAL RECEPTACLES AFCI 120 20 12 112 21 EXIST. SMALL APLIANCES GFI 120 20 EXIST EXIST 1,500 22 BATHROOM RECEPTACLES GFI 120 20 12 1/2 23 EXISTING GENERAL LIGHTS 120 20 EXIST EXIST * 24 BATHROOM RECEPTACLES GFI 120 20 12 1/2 25 EXISTING GENERAL LIGHTS 120 20 EXIST EXIST * 26 GENERAL LIGHTS 120 20 12 1/2 2T EXISTING GENERAL LIGHTS 120 20 EXIST EXIST * 2i GENERAL LIGHTS AFCI 120 20 12 1/2 29 EXISTING LANDSCAPE LIGHTS 120 20 EXIST EXIST 1,500 30 GENERAL RECEPTACLES AFCI 120 20 12 1/2 31 EXISTING LANDSCAPE LIGHTS 120 20 EXIST EXIST 1,500 32 GENERAL OUTDOOR LIGHTS 120 20 12 1/2 *560 33 EXISTING GENERAL LIGHTS 120 20 EXIST EXIST * 34 GENERAL RECEPTACLES AFCI 120 20 12 1/2 35 36 33 + 38 39 ' 40 _ * SEE LOAD CALCULATION Load Calculation ** VERIFY NAME PLATE As per N.E,C Art, 220.30 Section B. 1,526 sqf x 3 va /sqf = 4,538 va Other Loads = 43,760 va Subtotal = 48,338 va First 10,000 va @ 100 %. = 10,000 va Rest 38,331 va @ 40% = 15,335 va Subtotal = 25,335 va A/C Load = 10,632 va Total VA = 35,967 va Panel Load = 35,963/240 = 150 Amps FIELD CHANGES: THE CONTRACTOR SHALL CONSULT THE ENGINEER BEFORE THE IMPLEMENTATION OF FIELD CHANGES, MODIFICATIONS, ANO /OR ADDITIONS TO EQUIPMENT, INSTALLATION, AND /OR DISTRIBUTION THAT DEVIATE FROM THE ORIGINAL SIGNED, SEALED AND APPROVED PLANS. PROPOSED CHANGES, ADDITIONS, AND /OR MODIFICATIONS WHICH ARE INTENDED TO BE INCLUDED BY THE CONTRACTOR IN ITS "AS- BUILT" DRAWINGS SHALL BE REVIEWED BY THE ENGINEER AND APPROVED IN WRITING BEFORE THE CHANGES, MODIFICATIONS, AND /OR ADDITIONS ARE IMPLEMENTED, THE ENGINEER SHALL NOT BE RESPONSIBLE AND WILL NOT INTEGRATE FIELD CHANGES INTO THE ORIGINAL PLANS THAT HAVE NOT BEEN CONSULTED AND APPROVED BEFORE THEIR FIELD IMPLEMENTATION, THE INTEGRATION BY THE ENGINEER OF FIELD CHANGES, MODIFICATIONS, AND /OR ADDITIONS INTO THE ORIGINAL SET OF CLANS TO CREATE A FINAL "RECORD DRAWING" SET IS NOT INCLUDED IN THE ORIGINAL CONTRACT AND SHALL BE CONSIDERED ADDITIONAL SERVICES. I r RECORD DRAWINGS PLANS ARE PROTECTED UNDER THE COPYRIGHT LAWS OF FLORIDA: These record drawings have been prepared based ALL RIGHTS RESERVED on the information compiled and provided b p p y CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CDNDITIONS ON THE JOB. THE DESIGN PROFESSIONAL MUST BE NOTIFIED IN WRITING OF ANY VARIATION FROM THE PLANS. others. The engineer has not verified the accuracy ALL IDEAS DESIGN ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWINGS ARE OWNED BY AND THE PROPERTY OF THE DESIGN PROFESSIONAL AND WERE CREATED EVOLVED AND and/or completeness of this information and shall DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. ANY CHANCES TO THESE PLANS WITHOUT THE WRITTEN APPROVAL OF THE DESIGN PROFESSIONAL OR ANY CONSTRUCTION not be responsible for any errors or omissions that EXECUTED FROM THESE PLANS WITHOUT EXPRESSED APPROVAL OF THE DESIGN PROFESSIONAL CONSULTING may be incorporated herein as a result of erroneous SHALL AUTOMATICALLY RENDER THE DESIGN PROFESSIONAL AND THE ENGINEERING GROUP, PA, HARMLESS TO ANY LIABILITY CLAIMS, SUIT OR LITIGATION BY ANY INTERESTED PARTIES information provided by others. OF THE PROJECT. NO PART THEREOF OF THESE PLANS SHALL BE CORIED OR REPRODUCED BY ANY MEANS, OR USED IN CONNECTION WITH ANY WORK OTHER THAN FOR THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL FIELD CHANGES: THE CONTRACTOR SHALL CONSULT THE ENGINEER BEFORE THE IMPLEMENTATION OF FIELD CHANGES, MODIFICATIONS, ANO /OR ADDITIONS TO EQUIPMENT, INSTALLATION, AND /OR DISTRIBUTION THAT DEVIATE FROM THE ORIGINAL SIGNED, SEALED AND APPROVED PLANS. PROPOSED CHANGES, ADDITIONS, AND /OR MODIFICATIONS WHICH ARE INTENDED TO BE INCLUDED BY THE CONTRACTOR IN ITS "AS- BUILT" DRAWINGS SHALL BE REVIEWED BY THE ENGINEER AND APPROVED IN WRITING BEFORE THE CHANGES, MODIFICATIONS, AND /OR ADDITIONS ARE IMPLEMENTED, THE ENGINEER SHALL NOT BE RESPONSIBLE AND WILL NOT INTEGRATE FIELD CHANGES INTO THE ORIGINAL PLANS THAT HAVE NOT BEEN CONSULTED AND APPROVED BEFORE THEIR FIELD IMPLEMENTATION, THE INTEGRATION BY THE ENGINEER OF FIELD CHANGES, MODIFICATIONS, AND /OR ADDITIONS INTO THE ORIGINAL SET OF CLANS TO CREATE A FINAL "RECORD DRAWING" SET IS NOT INCLUDED IN THE ORIGINAL CONTRACT AND SHALL BE CONSIDERED ADDITIONAL SERVICES. I r