13-669R-001
OXYGEN /ANESTHESIA TANKS - ANCHORED AS REQUIRED BY OSHA NOTE: DOOR TO HAVE APPROVED SEAL INSTALLED AND IS TO BE LOCKED AT ALL TIMES. NOTE: BOTTOM OF DOOR TO BE UNDERCUT TO PROVIDE AMPLE ROOM TO PASS OXYGEN TUBING UNDERNEATH TO ANESTHESIA MACHINE IN O.R. AND TO ALLOW FOR PROPER VENTILATION FOR COMPRESSED GAS INSIDE TANKS. Aa9 10 -13 ADD STORAGE CLOSET' NOTE: DASHED LINE INDICATES CLEAR FLOOR AREA AROUND OPERATING TABLE. ALL LIGHTING AND ELECTRICAL IS TO BE CAREFULLY COORDINATED TO CORRESPOND WITH SURGICAL EQUIPMENT TO BE INSTALLED. SEE REQUIREMENTS FROM EQUIPMENT CONSULTANT. FiEM N A S. N IN OPE F W K. NEW FIRE -RATED TENANT SEPARATION WALLS EXTEND TO THE UNDERSIDE OF ROOF DECK AS PER FBC- 704.2.1.3. EXTG. FIRE RESISTANCE INTEGRITY WILL BE MAINTAINED BY U.L. LISTED PENETRATION SEALANTS AS PER FBC 705.4, 705.5, 705.6 ALL HAZARDOUS MATERIALS it WASTE TO BE STORED IN SECONDARY CONTAINMENT AREAS. ALL BIOHAZARDOUS SAMPLES AND WASTE COLLECTED ON SITE WILL BE COLLECTED, STORED, AND SENT TO OUTSIDE LABS DAILY FOR ANALYSIS OR DISPOSAL VIA A STATE APPROVED BIOHAZARDOUS WASTE TRANSPORTER. ALL SECONDARY CONTAINMENT AREAS MUST BE ABLE TO CONTAIN 110% OF THE LARGEST CONTAINER. DOLS TYPICAL AC 123 i 124 1 1 02 -01 -12 10'-112" EVISE DOOR AND R ft ON 5'- —14 -o-z TYPICAL STORAGE 121 , `' u9 — — — — — — — — A 09-10-13 2o ALL L S T ` ADD DOOR H ROPER IN TO PPOR DE IVERIES 118 SHELVIN AND STORAGE it BIOHAZARD STORED ATERI AND TO AVE 1 - 1 -HOUR IRE A7.0ni RATED P RTITI L - - - - -J Ln 1 1zz 121 io 1 LINEN 16'-82 ' 4 ANES. TOR. O / AN - 4 0 MIT DOOR p CAR I 0 HANDS FREE +� WA HAVE P PER TYPICAL VE 38" 1 SCRUB SINK 702 BACKING PPORT SURGICAL PREP Q CABINETS AND STORED �. MATERIAL MILLWORK - Qi oIRE RA I CABINET DOOR TO O.R. N fV FIRE RATED PARTITIONS DOORS I NEEDS SMALL M I I lz4 WINDOW WITHIN - llG 112 1- In 109 1" ;-� 1 6" i" 1 0 I _7 @ V -5'1 —� 6 2 5 -102 -10Z 10' -g2 1 08 -01 -12 REVISE CLOSET DO ORS I i ADA ESTROOM 111 .L J — SHELVING TREATMENT ROOM 104 r — ABOVE rt WALL TO HAVE PROPER 0 RECOVERY li \_ - - 4 09 -10 -13 BACKING TO SUPPORT 117 / REVISE DOOR SIZE HAND DRYER- o I CABINETS AND STORED / O!E ATING (ROOM 116 MATERIAL I SEE 110.0 I ^ WALLS ENCLOSING UTILITY 1 TAFF CKER 108 1 O125 ARE TO BE 1 -HOUR FIRE — 1 / 1' 62 113 •� +I TREATMENT ROOM 106 104 I �: RATED PARTITIONS 1 UTILI _ 1 irl F RE RATED PARTITIONS I • ' I = A7 Q L J _ STAFF LOUNGE 107 I WALK IN, TYPICAL = I SURFACE DISINFECTANTS, A, os -01 -12 I i;S 105 , WALL -LESS INSTRUMENT CLEANING CHEMICAL STORAGE 15'-102" 7 -1 - SOLUTIONS, LUBRICANTS, I WALL TO HAVE PROPER I SHOWER AND AUTOCLAVE CLEANING = BACKING TO SUPPORT L_ _ '"""' — '-"" "— — — — — — — J I SOLUTIONS TO BE STORED I *-+ CABINETS AND STORED IN UTILITY NURSE STATION MATERIAL _ RESTROOM 105 F. I WALL TO HAVE PROPER CD RESTROOM RESTROOM IS TYPICAL I BACKING TO SUPPORT —1 ADAPTABLE TO CABINETS AND STORED MEET FUTURE FULL - HEIGHT — — — — — — J — — — — — — — 114 ACCESSIBILTY 4 i MATERIAL CABINETRY --- - - - - -- �--� r7 � / ,� NEEDS i �' '� A7.0 i A4 09 -10 -13 ADD MECH. CLOSET e AOS -01 -12 FIRE RATED NOTE ONE -HOUR FIRE RATED CORRIDOR EXTG. STAIR j A7.0 I L_1� EXTG. DOOR TO REMAIN HALLWAY TYPICAL 9,_6 ", � 6 _ 1 ' ' 17' -411 �05 OFFICE 101 io I WALLS TO 102 F io I WAITING ROOM 100 HAVE PROPER 11a 4' 2' -2" PRE -OP HOL ING 110 BACKING TO - �",,b,'y I SUPPORT 107 I CABINETS _ _ _ _ _ _ �+ lls AND STORED - - MATERIAL _ Ln 4'_6 ", 3 "_3.. 4., -02" 't 112.. 4. -3.. 2' =._5.. 10' -g2 4 09 -10 -13 TYPICAL O+ 111 1 REVISE LAYOUT 103 2 v i 10 -52 for rbr„ O WALL TO HAVE PROPER A7.0 O BACKING TO SUPPORT HALLWAY <9> rn CABINETS AND STORED MATERIAL - lac PAT. LOCKS AID ED MCM . BELOW /STORE STORAGE revi si ons : ABOVE i I South Miami Advanced I U",,CM" ALL WALLS TO HAVE PROPER BACKING TO SUPPORT CABINETS AND STORED MATERIAL WALL TO HAVE PROPER BACKING TO SUPPORT CABINETS AND STORED MATERIAL NOTE: THIS IS AN OFFICE BASED SURGICAL FACILITY. THIS IS NOT AN AMBULATORY FACILITY. A0{ -01 -12 OCCUPANCY CLARIFICATION z FLOOR PLAN SCALE: 1/4" — V -0" TYPICAL 4 A7.0 OL•J r 4Q 09 -10 -13 REVISE LAYOUT M D,EM N© W V UY1i 1 iY• III r1i v U V111U G U • � V •or " CONSTRUCTION N ?TES yy • • U U y 4J 4 U U u• U U 1, THE PARTITION LAYOUT IS TO BE�DEMARCAT!F� ON TuE FLOOR•,•„ REVIEWED, AND APPROVED BY THE �,RCHITECT PPOR ry 0 4 Y CONSTRUCTION. ANY DIMENSIONAL DISrREPANCIES tRE TO p .--- REPORTED TO THE ARCHITECT PRIOR 70— CONSTKOC7ION. 2. ALL INTERIOR PARTITIONS ARE SLAB TO SUSPENDED CEILING, EXTENDING PAST SUSPENDED CEILING W/ 5/8" TYPE "X" WALL BOARD EACH SIDE. USE R -19 BATT INSULATION BETWEEN ALL WAY TO BOTT. OF SLAB & STAGGER ALL ELECTRICAL DEVICES FOR MAX. SOUND ATTENUATION. 3. 2 HR. FIRE SEAL @ ALL EXTG. & NEW PIPES, DUCTS, CHASES, ETC. PENETRATING FLOOR & CEILING SLABS. 4. CLEAN, REPAIR & PAINT, WINDOW FRAMES AS NEEDED -MEET W/ ARCHITECT TO DETERMINE. 5. ALL WALLS SUPPORTING SHELVING, CABINETRY, MILLWORK, AND GRAB BARS ARE TO BE REINFORCED WITH PROPER BACKING TO SAFELY SUPPORT AND ANCHOR THE ADDITIONAL LOADS. 6. PLUMBING WORK IN THIS SUITE WILL NEED TO BE DONE FROM CEILING BELOW, THEREFORE CEILING IN GARAGE AND DRIVEWAY WILL NEED TO BE OPENED TO ACCESS PLUMBING PIPES AND MUST BE REPAIRED ACCORDINGLY AFTER THE WORK IS COMPLETE. WALL LEGEND EXISTING WALL TO REMAIN NEW CAST -IN -PLACE CONC. WALL, SEE STRUCTURAL DRAWINGS NEW 8" CMU WALL. 3/4" STUCCO FINISH ON EXTERIOR FACE AND 5/8" GYP. BOARD OVER 7/8" MTL. FURRING Ca 16" O.C. W/ RIGID INSULATION BETWEEN FURRING ON INTERIOR., SEE STRUCTURAL NEW INTERIOR PARTITION W/3-5/8" METAL STUDS AT 16" O.C. AND 5/8" GYP. BOARD BOTH SIDES PROVIDE INSULATION BETWEEN STUDS - USE MOISTURE RESISTANT TYPE AT ALL DAMP LOCATIONS (BATHROOM, LAUNDRY, KITCHEN, BACKSPLASH, ETC.). USE 6" METAL STUDS AT 16" O.C. AS REQUIRED FOR PLUMBIN S. iii NEW INTERIOR FIRE RATED PAkTIT10N W/ 3 5/8" METAL STUDS AT 16" O.C. AND 5/8" TYPE'X' GYP. BOARDS BOTH SIDES. UL DESIGN NO. U419 Ad� O1 12 UL APPROVALNUMiER NEW INTERIOR PARTIAL HEIGHT PARTITION W/ 3 -5/8" METAL STUDS AT 16" O.C. AND 5/8" GYP. BOARD BOTH SIDES. NOTES: ANESTHETIZING LOCATIONS ARE TO COMPLY WITH THE REQUIREMENTS OF NFPA 99. NFPA 38.3.3 INTERIOR FINISH: INTERIOR WALL AND CEILING FINISH: EXITS AND EXIT ACCESS CORRIDORS CLASS A OR CLASS B ALL OTHER AREAS CLASS A, CLASS B, OR CLASS C 0 y� 0 low � QQ F r�. O 0 A0! 01-12 c UL APPROVAL NUMBER V 0 6 20 l3 i i k i, AID ED MCM . --..� -- -_ _ _ _ -- - r project: I revi si ons : aR aY: I South Miami Advanced I U",,CM" I Center for Surgery I A0111-01-12 I DR. ALAN SERURE A09 -19 -12 DATtj C I SUITE 00 2 PLACE A10 UPSTAIRS STUDIO _ I SOUTH MIAMI, FL 33143 1 -17 -12 3-- architecture - - - - -- _ _ _ _ A 0l -SO -is /� ® Maricarman Martinez, AIA Ln � L� 3941 Midway Street 7;::1 Miami, Florida 33133 Tel 305 447 -1907 Fax 305 447-1904 Q— A3111111111111 0 e mai: Inf+CtU P stairsstudi+architecture.C+m p FLORIDA LICENSE: M 0003141 i i k i,