12-669-040ELECTRICAL SYMBOL LEGEND 1- GENERAL CONDITIONS: THE GENERAL CONDITIONS FORM A PART OF THE SPECIFICATIONS FOR THIS TRADE. EACH SUB - CONTRACTOR MUST READ GENERAL CONDITIONS, AS WELL AS THE SPECIFICATIONS FOR WORK OF OTHER TRADES AND TO ASCERTAIN WHAT WORK AND MATERIALS HE MUST SUPPLY TO THE OTHER CONTRACTORS. 2- SITE INVESTIGATION: IT SHALL BE THE RESPONSABILITY OF BIDDERS TO VISIT THE SITE AND TO ACQUAINT THEMSELVES WITH AL INFORMATION REGARDING THE NEW BUILDING. 3- DESIGN: THE INSTALLATION OF THE WIRING SYSTEM SHOWN ON THESE DWGS. SHALL CONFORM TO THE REGULATIONS OF LOCAL CODES AND ORDINANCES, N.E.C. AND LOCAL UTILITY COMPANIES. 4- MINIMUM STANDARDS: THE MATERIAL, INSTALLATIONS AND WORKMANSHIP FURNISHED UNDER THIS SECTION SHALL CONFORM TO THE REQUIREMENTS OF LOCAL CODES AND N.E.C., ALL MATERIALS USED SHALL BE LISTED OR BEAR U.L. APPROVAL. 5- GUARANTEE: THIS SUB - CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE THAT ALL WORK EXECUTED UNDER THIS CONTRACT, SHALL BE FREE FROM DEFECTS OR WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR, AT CONTRACTOR'S EXPENSE, REPAIR AND REPLACE ALL WORK WHICH BECOMES DEFECTIVE DURING THE TIME OF THE GUARANTEE. 6- RACEWAYS AND FITTINGS: a RIGID GALVANIZED : 1 -1/2" OR LARGER , AND IN SLAB ABOVE GRADE. b PVC : IN OR UNDER GND FLOOR SLAB cjjjjjj EMT : ALL OTHER LOCATION. d) ARMORED CABLE, MC: ABOVE SLAB, BRANCH CIRCUITS ONLY. e) FITTINGS: TO MATCH APPROVED RACEWAY . 7- CONDUCTORS: THE MINIMUM CONDUCTOR NO.12 SOLID CU. TYPE "THW" INSULATION. ALUMINUM CONDUCTOR ALLOWED ONLY WHERE INDICATED ON DRAWINGS. 8- ALL EQUIPMENT LISTED ON DWGS. BY CATALOG NO. SHALL BE LIMITED TO THE KIND AND MANUFACTURE LISTED. NO SUBSTITUTION SHALL BE ALLOWED UNLESS APPROVED BY THE ENGINEER. A WRITTEN GUARANTEE OF THREE YEARS AND CREDIT FROM BASIC BID SHALL BE SUBMITTED WITH SHOP DRAWINGS. 9- CONTRACTOR TO INSTALL AND /OR CONNECT ALL EQUIPMENTS AND CONTROLS SUPPLIED BY OWNER, OR ANY OTHER TRADE. SEE OTHER TRADES DRAWINGS AND SPECIFICATIONS. 10- ALL FEEDERS AND BREAKERS SHALL BE COORDINATED WITH EQUIPMENT'S PLATE AT SITE. `itutnr��� PEN �'i G44 S 41 % Q� `tG •f y No 1639 s 7� • ,f .cc r . : Uj IAEU PEt, JR. oaAR \3 SIO N a\- r��ne���11>t� QUADRUPLE (DOUBLE DUPLEX) ® DOOR BELL 1-Z DUPLEX OUTLET �° DOOR BELL PUSH BUTTON EXIT /EMERGENCY LIGHT COMBINATION 120 V 120V SMOKE ALARM (EQUAL TO KIDDE MODEL '-O ISOLATED GROUND DUPLEX OUTLET O P12000) CONNECTED TO LINE SIDE OF LOCAL .2W 1 ISOLATED GROUND QUADRUPLE OUTLET CIRCUIT. ALL SMOKE ALARMS SHALL BE INTERCONNECTED. architecture HALF SWITCHABLE DUPLEX OULET 120 V 120V COMBINATION CARBON MONOXIDE / SMOKE 3941 Midway Street ALARM (EQUAL TO KIDDE MODEL KN- COSM -IB) SINGLE OUTLET (GROUNDING) CONNECTED TO LINE SIDE OF LOCAL CIRCUIT, Tel 305 447 -1907 Fax 305 447 -1906 SPECIAL PURPOSE (120/240: L,L N, & GND) a g AND SHALL BE INTERCONNECTED WITH SMOKE Ao ALARMS. Q FLOOR BOX AS MANUFACTURED BY RCI MODEL BIG 2" OR EQUAL, ® ELECTRICAL PANEL UNLESS NOTED. O JUNCTION BOX lfvvvL FLEXIBLE CONDUIT G.F.I. DUPLEX OUTLET — — — CONDUIT RUN EXPOSED j� ABOVE - COUNTER DUPLEX RECEPTACLE —"� CONDUIT CONCEALED IN WALLS OR OVERHEAD (SHOWN WITH TWO HOT & NEUTRAL) ABOVE - COUNTER G.F.I. DUPLEX RECEPTACLES CONDUIT IN OR UNDER THE SLAB (SHOWN WITH HOT, NEUTRAL & GROUND) ® TV OUTLET 1x4 FLUORESCENT LIGHT FIXTURE v TELEPHONE OUTLET ®0 DATA OUTLET 2x4 FLUORESCENT LIGHT FIXTURE COMMUNICATION & DATA STRUCTURAL OUTLET COMBINATION. S SINGLE POLE SWITCH 2x2 FLUORESCENT LIGHT FIXTURE S3 THREE WAY SWITCH F---QI 4' FLUORESCENT LIGHT STRIP S4 FOUR WAY SWITCH SURFACE MID. FLUORESCENT LIGHT FIXTURE or SB SERVICE BREAKER (FACTORY INSTALLED) ,J� SURFACE FLUORESCENT, UNLESS NOTED 9 CEILING FAN CONTROL SWITCH COMBINATION SD PENDANT LIGHT FIXTURE DIMMER SWITCH T P ® LOW VOLTAGE TRANSFORMER O RECESS HI -HAT LIGHT FUXTURE ® WALL WASH LIGHT FIXTURE EXHAUST FAN FQ WALL MOUNTED LIGHT FIXTURE MOTOR ® STEP LIGHT FIXTURE ® STARTER OR CONTROL PANEL O MJ COMBINATION STARTER CEILING FAN QI DISCONNECT SWITCH - WP INDICATES WEATHERPROOF (TYP.) 6F% NOTE: ALL FLUORECENT LUMINAIRES THAT UTILIZE DOUBLE -ENDED 340 DISCONNECT SIZE (3 DENOTES NO. POLES, LAMPS AND CONTAINS BALLAST(S) SHALL BE PROVIDED 60 DENOTES DISCONNECT RATED AMPERAGE, WITH FACTORY INSTALLED SEPARABLE PLUG LOCATED 40 DENOTES FUSE SIZE [NF DENOTES NON- FUSED] AT THE BALLAST COMPARTMENT TO COMPLY WITH WITH N.E.C. 410.130 (G). (TYP). 1- GENERAL CONDITIONS: THE GENERAL CONDITIONS FORM A PART OF THE SPECIFICATIONS FOR THIS TRADE. EACH SUB - CONTRACTOR MUST READ GENERAL CONDITIONS, AS WELL AS THE SPECIFICATIONS FOR WORK OF OTHER TRADES AND TO ASCERTAIN WHAT WORK AND MATERIALS HE MUST SUPPLY TO THE OTHER CONTRACTORS. 2- SITE INVESTIGATION: IT SHALL BE THE RESPONSABILITY OF BIDDERS TO VISIT THE SITE AND TO ACQUAINT THEMSELVES WITH AL INFORMATION REGARDING THE NEW BUILDING. 3- DESIGN: THE INSTALLATION OF THE WIRING SYSTEM SHOWN ON THESE DWGS. SHALL CONFORM TO THE REGULATIONS OF LOCAL CODES AND ORDINANCES, N.E.C. AND LOCAL UTILITY COMPANIES. 4- MINIMUM STANDARDS: THE MATERIAL, INSTALLATIONS AND WORKMANSHIP FURNISHED UNDER THIS SECTION SHALL CONFORM TO THE REQUIREMENTS OF LOCAL CODES AND N.E.C., ALL MATERIALS USED SHALL BE LISTED OR BEAR U.L. APPROVAL. 5- GUARANTEE: THIS SUB - CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE THAT ALL WORK EXECUTED UNDER THIS CONTRACT, SHALL BE FREE FROM DEFECTS OR WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR, AT CONTRACTOR'S EXPENSE, REPAIR AND REPLACE ALL WORK WHICH BECOMES DEFECTIVE DURING THE TIME OF THE GUARANTEE. 6- RACEWAYS AND FITTINGS: a RIGID GALVANIZED : 1 -1/2" OR LARGER , AND IN SLAB ABOVE GRADE. b PVC : IN OR UNDER GND FLOOR SLAB cjjjjjj EMT : ALL OTHER LOCATION. d) ARMORED CABLE, MC: ABOVE SLAB, BRANCH CIRCUITS ONLY. e) FITTINGS: TO MATCH APPROVED RACEWAY . 7- CONDUCTORS: THE MINIMUM CONDUCTOR NO.12 SOLID CU. TYPE "THW" INSULATION. ALUMINUM CONDUCTOR ALLOWED ONLY WHERE INDICATED ON DRAWINGS. 8- ALL EQUIPMENT LISTED ON DWGS. BY CATALOG NO. SHALL BE LIMITED TO THE KIND AND MANUFACTURE LISTED. NO SUBSTITUTION SHALL BE ALLOWED UNLESS APPROVED BY THE ENGINEER. A WRITTEN GUARANTEE OF THREE YEARS AND CREDIT FROM BASIC BID SHALL BE SUBMITTED WITH SHOP DRAWINGS. 9- CONTRACTOR TO INSTALL AND /OR CONNECT ALL EQUIPMENTS AND CONTROLS SUPPLIED BY OWNER, OR ANY OTHER TRADE. SEE OTHER TRADES DRAWINGS AND SPECIFICATIONS. 10- ALL FEEDERS AND BREAKERS SHALL BE COORDINATED WITH EQUIPMENT'S PLATE AT SITE. `itutnr��� PEN �'i G44 S 41 % Q� `tG •f y No 1639 s 7� • ,f .cc r . : Uj IAEU PEt, JR. oaAR \3 SIO N a\- r��ne���11>t� ABBREVATIONS GFCI GROUND -FAULT CIRCUIT - INTERRUPTER AFCI ARC -FAULT CIRCUIT INTERRUPTER AFF ABOVE FINISH FLOOR WP WEATHER PROOF U/C INSTALLED UNDER COUNTER I/C INSTALLED IN ATTIC SPACE SCR MINIMUM AIC OF BREAKER IN PANEL AND PANEL BRAZING INSTALLATION NOTES A) MOUNT WIRING DEVICES CENTER LINE @ HEIGHT ABOVE FINISHED FLOOR INDICATED BELLOW: A) RECEPTACLES: @ 18" B) LIGHT SWITCHES: @ 46" C) TELEPHONE JACKS: KITCHEN @ 42 ", ALL OTHRES @ 18" D) THERMOSTATS: @ 46" B} BATHROOM WALL MOUNTED FIXTURES: 6" OVER THE CENTER UNE OF THE MIRROR OR AS SHOWN IN THE ARCHITECTURAL DRAWINGS. C) LIGHT SCONCES TO BE MOUNTED @ 6' -6" A.F.F. OR AS SHOWN IN IN THE ARCHITECTURAL DRAWINGS. SCONCES MOUNTED BELOW 6' -6" SHALL NOT PROTUDE NOT MORE THAT 4" INTO WALKWAYS, HALLS, CORRIDORS, OR AISLES. COORDINATE WITH ARCHITECTURAL ELEVATIONS. GENERAL LEGEND • TES (aAmaxellsolagrgl1mg 1. ALL 125 -VOLT, SINGLE - PHASE, 15 AND 20 AMPERE RECEPTACLES INSTALLED AT PUBLIC BATHROOMS, KITCHEN AREAS, GARAGES, OR OTHER COMUN AREAS AS SPECIFIED IN THE NEC SHALL BE GFCI PROTECTED. 2. ALL 125 AND 250 VOLT, 15 AND 20 AMPERE NON LOCKING RECEPTACLES INSTALLED IN DAMP OR WET LOCATIONS SHALL BE GFCI PROTECTED AND LISTED AS WEATHER - RESISTANT TYPE. GENERAL CONSTRUCTION NOTES: 1. ALTERATIONS TO EXISTING WORK BEING OF SUCH NATURE THAT ALL FACETS OF THE WORK ARE IMPOSSIBLE TO DETAIL AND SPECIFY. IT IS THEREFORE THE RESPONSABILITY OF THE CONTRACTOR TO CARE- FULLY EXAMINE THE BUILDING AND THE GROUNDS AND FAMILIARIZE HIMSELF WITH THE CONDITIONS AND RELATE THESE CONDITIONS TO THE SCOPE OF THE PROPOSED WORK PRIOR TO BIDDING. 2. ANY EXISTING INSTALLATION PROBLEMS OR EXISTING CODE VIOLATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT /ENGINEER PRIOR TO BIDDING. 3. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXISTING ELECTRICAL INTALLATION, THE WORKING CONDITIONS OF THE EXISTING ELECTRICAL PANELS, LIHGT FIXTURES AT THE STAIRS, FIRE ALARM SYSTEM AND DEVICES AND A WRITTEN REPORT TO THE OWNER WITH THE BID PROPOSAL. 4. ANY ELECTRICAL WORK WHICH WILL INTERFERE WITH THE BUILDING TENANTS NORNAL OPERATION SHALL BE NOTIFIED IN ADVANCE TO THE BUILDING OWNER OR MANAGER AND SHALL BE DONE AFTER BUILDING NORMAL OPERATION HOURS OR ON WEEKENDS. 5. THE ELECTRICAL CONTRACTOR SHALL PROVIDE TO THE OWNER AT THE END OF THE WORK A SET OF AS BUTT DRAWINGS. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AT EACH EXISTING AND NEW ELECTRICAL PANELS A WRITTEN PANEL SCHEDULE WITH THE PROPER TYPE OF LOAD IDENTINFICATION AND THE ROOM NUMBER THAT ARE FEEFDING. 6. ALL DEVICES, EQUIPMENT, ETC. WHETHER SHOWN OR NOT, TO BE PROPERLY CONNECTED ELECTRICALLY, UNLESS SPECIFICALLY NOTED TO BE REMOVED. RPJ, Inc. Mec mkW1BectricsJ C nadHnm Er>gheera STATE OF FL CO. NO. (00006513) P.E. N0. (16395) 4977 S.W. 74th COURT MIAMI, FL 33155 PHONE: (305) 666 -2131 FAX: (305) 666 -0131 E —Mail: rpfnep®bellsouth.net APP VED RPI EMERGENCY LIGHT 1-Z WALL MTD EXIT SIGN (SHOWN WITH TWO FACES) EXIT LIGHT (SHOWN WITH ONE FACE AND DIRECTIONAL ARROW) EXIT /EMERGENCY LIGHT COMBINATION '-O ARM MOUNTED POLE LIGHT O TOP MOUNTED POLE LIGHT ABBREVATIONS GFCI GROUND -FAULT CIRCUIT - INTERRUPTER AFCI ARC -FAULT CIRCUIT INTERRUPTER AFF ABOVE FINISH FLOOR WP WEATHER PROOF U/C INSTALLED UNDER COUNTER I/C INSTALLED IN ATTIC SPACE SCR MINIMUM AIC OF BREAKER IN PANEL AND PANEL BRAZING INSTALLATION NOTES A) MOUNT WIRING DEVICES CENTER LINE @ HEIGHT ABOVE FINISHED FLOOR INDICATED BELLOW: A) RECEPTACLES: @ 18" B) LIGHT SWITCHES: @ 46" C) TELEPHONE JACKS: KITCHEN @ 42 ", ALL OTHRES @ 18" D) THERMOSTATS: @ 46" B} BATHROOM WALL MOUNTED FIXTURES: 6" OVER THE CENTER UNE OF THE MIRROR OR AS SHOWN IN THE ARCHITECTURAL DRAWINGS. C) LIGHT SCONCES TO BE MOUNTED @ 6' -6" A.F.F. OR AS SHOWN IN IN THE ARCHITECTURAL DRAWINGS. SCONCES MOUNTED BELOW 6' -6" SHALL NOT PROTUDE NOT MORE THAT 4" INTO WALKWAYS, HALLS, CORRIDORS, OR AISLES. COORDINATE WITH ARCHITECTURAL ELEVATIONS. GENERAL LEGEND • TES (aAmaxellsolagrgl1mg 1. ALL 125 -VOLT, SINGLE - PHASE, 15 AND 20 AMPERE RECEPTACLES INSTALLED AT PUBLIC BATHROOMS, KITCHEN AREAS, GARAGES, OR OTHER COMUN AREAS AS SPECIFIED IN THE NEC SHALL BE GFCI PROTECTED. 2. ALL 125 AND 250 VOLT, 15 AND 20 AMPERE NON LOCKING RECEPTACLES INSTALLED IN DAMP OR WET LOCATIONS SHALL BE GFCI PROTECTED AND LISTED AS WEATHER - RESISTANT TYPE. GENERAL CONSTRUCTION NOTES: 1. ALTERATIONS TO EXISTING WORK BEING OF SUCH NATURE THAT ALL FACETS OF THE WORK ARE IMPOSSIBLE TO DETAIL AND SPECIFY. IT IS THEREFORE THE RESPONSABILITY OF THE CONTRACTOR TO CARE- FULLY EXAMINE THE BUILDING AND THE GROUNDS AND FAMILIARIZE HIMSELF WITH THE CONDITIONS AND RELATE THESE CONDITIONS TO THE SCOPE OF THE PROPOSED WORK PRIOR TO BIDDING. 2. ANY EXISTING INSTALLATION PROBLEMS OR EXISTING CODE VIOLATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT /ENGINEER PRIOR TO BIDDING. 3. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXISTING ELECTRICAL INTALLATION, THE WORKING CONDITIONS OF THE EXISTING ELECTRICAL PANELS, LIHGT FIXTURES AT THE STAIRS, FIRE ALARM SYSTEM AND DEVICES AND A WRITTEN REPORT TO THE OWNER WITH THE BID PROPOSAL. 4. ANY ELECTRICAL WORK WHICH WILL INTERFERE WITH THE BUILDING TENANTS NORNAL OPERATION SHALL BE NOTIFIED IN ADVANCE TO THE BUILDING OWNER OR MANAGER AND SHALL BE DONE AFTER BUILDING NORMAL OPERATION HOURS OR ON WEEKENDS. 5. THE ELECTRICAL CONTRACTOR SHALL PROVIDE TO THE OWNER AT THE END OF THE WORK A SET OF AS BUTT DRAWINGS. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AT EACH EXISTING AND NEW ELECTRICAL PANELS A WRITTEN PANEL SCHEDULE WITH THE PROPER TYPE OF LOAD IDENTINFICATION AND THE ROOM NUMBER THAT ARE FEEFDING. 6. ALL DEVICES, EQUIPMENT, ETC. WHETHER SHOWN OR NOT, TO BE PROPERLY CONNECTED ELECTRICALLY, UNLESS SPECIFICALLY NOTED TO BE REMOVED. RPJ, Inc. Mec mkW1BectricsJ C nadHnm Er>gheera STATE OF FL CO. NO. (00006513) P.E. N0. (16395) 4977 S.W. 74th COURT MIAMI, FL 33155 PHONE: (305) 666 -2131 FAX: (305) 666 -0131 E —Mail: rpfnep®bellsouth.net r----------------------------- I project: ' I DR. ALAN SERURE 1 1 1 1 1 7330 SW 62 PLACE 1 SOUTH MIAMI, FL 33143 1 I 1 1 1 I 1 I ffi APP VED RPI revisions : D AP(VT f /�\ A DA 06 -27 -12 U A .2W 1 UPSTAIRS STUDIO architecture Maricarmen Martinez, AIA 3941 Midway Street Miami, Florida 33133 Tel 305 447 -1907 Fax 305 447 -1906 a g e -mail: info @upstairsstudioarchitecture.com Ao FLORIDA LICENSE: AA 0003148 r----------------------------- I project: ' I DR. ALAN SERURE 1 1 1 1 1 7330 SW 62 PLACE 1 SOUTH MIAMI, FL 33143 1 I 1 1 1 I 1 I ffi