12-669-024NOTE: THIS IS A BUSINESS OCCUPANCY - OFFICE BASED SURGICAL FACILITY
THIS NOT AN AMBULATORY FACILITY
OCCUPANCY LOAD: 2,813 SQ. Fr. / 100 SQ. Fr. PER PERSON
28 MAXIMUM OCCUPANCY
MEANS OF EGRESS AS PER NFPA SECTION 38.2.5.2.2, 38.2-5.3.2, 38.2-6.2
ALLOWED:
20' DEAD END CORRIDOR LIMIT
75' MAXIMUM COMMON PATH OF TRAVEL LIMIT
200' MAXIMUM TRAVEL DISTANCE
PROPOSED:
MAX DEAD END CORRIDOR = 15'-3"
MAX COMMON PATH OF TRAVEL = 59'-9"
MAX TRAVEL DISTANCE = 59'-9"
NUMBER OF EXITS: 2
EGRESS CAPACITY: 34" / 0.2 PER PERSON = 170 PERSONS
%
VJ'r' COD i
FARVAR
M
LIFE SAFETY
Z