Loading...
12-669-022■ El El El 1:1 a NOTE: THIS IS A BUSINESS OCCUPANCY - OFFICE BASED SURGICAL FACILITY THIS NOT AN AMBULATORY FACILITY OCCUPANCY LOAD: 2,813 SQ. Fr. / 100 SQ. FT. PER PERSON 28 MAXIMUM OCCUPANCY MEANS OF EGRESS AS PER NFPA SECTION 38.2.5.2.2, 38.2.5.3.2, 38.2.6.2 ALLOWED: 20' DEAD END CORRIDOR LIMIT 75' MAXIMUM COMMON PATH OF TRAVEL LIMIT 200' MAXIMUM TRAVEL DISTANCE PROPOSED: MAX DEAD END CORRIDOR = 15'-3" MAX COMMON PATH OF TRAVEL = 59'-9" MAX TRAVEL DISTANCE = 59'-9" NUMBER OF EXITS: 2 EGRESS CAPACITY: 34" / 0.2 PER PERSON = 170 PERSONS r7 co 07 O� Klk SET FO APP d7B� 'k MCM DPQBY: revi si ons: D, CM A08-01-12 02012 UPSTAIRS STUDIO'— A architecture Maricarmen Martinez, AZA A3941 Midway Street Miami, Florida 33133 LIFESAFETY PLAN GROUND FLOOR Tel 305 "7-1907 Fax 305 "7-1906 SCALE: 3/16" = V-011 e-mail: info@up;t7;irsstudioarchitecture.com FLORIDA LICENSE: AA 0003148 -------------- project: i South Miami Advanced I Center for Surgery DR. ALAN SERURE 7330 SW 62 PLACE SUITE 200 SOUTH MIAMI, FL 33143 L-------- - - - - -J A3.1 (D 10 mm Q Y -------------- project: i South Miami Advanced I Center for Surgery DR. ALAN SERURE 7330 SW 62 PLACE SUITE 200 SOUTH MIAMI, FL 33143 L-------- - - - - -J A3.1 (D 10