12-669-017General Notes: Security and Forced Entry Notes:
1 All single exterior swinging doors shall have a lock, to be key - operated from the
1. The general contractor must have an operating fax machine and a telephone on the job exterior with a minimum of 6,000 possible key changes, or locking single dead bolt
site at all times. w/ hardened bolt insert.
2 All locks on exterior doors shall be capable or resisting a force of 300 pounds
2. General Contractor shall install a first aid kit at job site in a readily accessible location. applied in any movable direction and in accordance with resistance standards set
forth in the 2004 Florida Building Code.
3. All work shall be in strict accordance with the best workmanship practices of the 3 The active leaf of a pair of exterior swinging doors shall have the same lock as
construction trade. Architect reserves the right to reject a material or work, which does not required for a single exterior swinging door. The inactive leaf of these pair of
conform to these standards. doors shall have a multiple point lock with 5/8" minimum throw bolts with inserts.
4 Sliding glass doors shall be provided with sliding door dead bolts or a bolt or pin,
4. All work shall be in accordance with the 2010 Florida Building Code and other applicable not removable or operated from the exterior. At the jamb, head, sill or meeting
codes. mullions. These doors shall be constructed so that no panel can be lifted from the
track when in a locked position.
5. All materials furnished on the site shall be new and stored in such a manner as to protect 5 Hinges on the exterior out swinging doors shall have non - removable pins.
them from the elements. General Contractor shall keep the site clean and free of debris and 6 Jambs of all exterior offset type, in- swinging doors shall be rabbeted or of a
dust at all times during the construction period. similar fabrication to maintain the integrity of locks and hatches.
7 Vision panels of exterior doors, other than glazing within 40" of the inside lock
6. These plans may be used only under such conditions in which all applicable safety laws, I activating device, shall comply with ANSI 297.1.
rules, and regulations are being observed. Compliance is the sole responsibility of the 8 Exterior swinging doors, if wood, shall be of 1 -3/4" thick solid core construction.
General Contractor.
7. The architect shall be provided with samples, submittals, shop drawings for fixed and
operable hurricane shutters, millwork, fireplace, windows and doors, and trusses, etc.
8. Noted dimensions shall have precedence over scaled dimensions. The architect shall be
notified of any discrepancies before the start of work. The Architect must be notified in
writing if scaled dimensions are being used.
9. The General Contractor shall be responsible for all permits, fees, licenses, and taxes
related to work.
10. General Contractor is responsible for all work provided by subcontractors of the various
trades.
11. Surfaces to be painted shall be filled, sealed, and sanded and primed as required.
Colors to be selected by the architect. Four test samples shall be made prior to execution of
work. The architect shall also select colors of prefabricated products.
12. All intrusion preventing devices shall conform to the 2010 Florida Building Code. See
security and forced entry notes.
13. General Contractor shall be responsible that architectural, structural, electrical,
mechanical drawings are employed simultaneously in the construction of this project. Any
discrepancies shall be reported to the architect immediately.
14. Contractor shall maintain a set of drawings at the project site with up to -date
information on as -built conditions indicating with colored pens all changes and deviations
from the contract drawings. This set of prints shall be turned over to the architect /engineer
with the corresponding permits at the completion of the project as a pre - requisite for final
payment.
15. No deviations of these plans are allowed except with written authorization from the
architect.
16. Before submission of bid, the General Contractor shall visit the site and become
familiarized with the existing conditions and notify the architect of any findings not
addressed in the bid documents.
17. Lawful and proper disposal of all waste material shall be the responsibility of the General
Contractor.
18. General Contractor shall take special precautions and coordinate with the owner that the
building is secure at all times during the construction period. General Contractor shall
coordinate construction schedule with owner and his security services prior to construction
start.
19. Any demolition shall be in strict accordance with structural engineering requirements.
Refer to shoring and demolition plans on the structural sheets. Special care shall be taken
during the demolition and construction period that no damage will occur to anything in
existing areas which was intended to remain. Any damage to existing construction to remain
must be repaired by the general contractor at no cost to the owner.
20. No substitutions shall be permitted without written authorization of the Architect.
21. A/C should not run during construction so that dust does not permiate the duct and fan
components.
22. Site must be vaccurned and dust free at the close of each working day.
South Miami Advancedi
C:enter for Surgery
SHEET LEGEND:
F. r 1
AO .0
COVER SHEET
A3.0
FLOOR PLAN
A4.0
REFLECTED CEILING ,
A7.0
WALL SECTIONS
•:
•' ELEVATIONS
A:
•• ELEVATIONS
A10.0
UPSTAIRS STUDIO
FLOORING
ENGINEERING:
ME1.0 MECHANICAL, ELECTRICAL, PLUMBING SPECS
M -1.0 MECHANICAL PLANS
M -2.0 SCHEDULES AND DETAILS
E1.0 POWER PLANS
E2.0 LIGHTING PLAN
E3.0 PANEL SCHEDULES AND RISER DIAGRAMS
E4.0 NOTES AND LEGEND
P1.0 SANITARY PLAN AND ISOMETRIC
P2.0 WATER PLAN AND ISOMETRICS
P3.0 NOTES, DETAILS, SCHEDULES, AND LEGENDS
ARCHITECT:
UPSTAIRSSTUDIO, r rNC- AR-CHTTECTURE
Maricarmen Martinez, AIA rt m _ _ _ _ w _ - . - _ ..
Principal
3941 Midway Street
Miami, Florida 33133
TEL (305) 447 -1907 FAX (305) 447 -1906
ENGINEER:
RPJ, INC.
RAFAEL PENA
4977 SW 74 COURT
MIAMI, FL 33155
TEL (305) 666 -2131 FAX (305) 666 -0131
revisions:
A
A
d
nd
U
a
Q
A
APP YED
MCM
D BY:
-
project:
I South Miami Advanced I
Mcm
I Center for Surgery I
DAT .
U
I DR. ALAN SERURE I
I 7330 SW 62 PLACE
06!27(12
C
SUITE 200 I
UPSTAIRS STUDIO
I sour" MIAMI, FL 33143 I
c
a,rphb e-d
architecture
_ - �- _ J
Marlearmen Martinez, AIA
3941 Midway Street
Miami, Florida 33133
n}
Tel 305 447 -1907 Fax 305 447 -1906
}
e -mail: info @upstairsstudioarchitectx
p FLORIDA LICENSE: AA 0003148
MMI
r
a
w ;�