Loading...
12-669-016General Notes: 1. The general contractor must have an operating fax machine and a telephone on the job site at all times. 2. General Contractor shall install a first aid kit at job site in a readily accessible location. 3. All work shall be in strict accordance with the best workmanship practices of the construction trade. Architect reserves the right to reject a material or work, which does not conform to these standards. 4. All work shall be in accordance with the 2010 Florida Building Code and other applicable codes. 5. All materials furnished on the site shall be new and stored in such a manner as to protect them from the elements. General Contractor shall keep the site clean and free of debris and dust at all times during the construction period. 6. These plans may be used only under such conditions in which all applicable safety laws, rules, and regulations are being observed. Compliance is the sole responsibility of the General Contractor. 7. The architect shall be provided with samples, submittals, shop drawings for fixed and operable hurricane shutters, millwork, fireplace, windows and doors, and trusses, etc. Security and Forced Entry Notes: 1 All single exterior swinging doors shall have a lock, to be key - operated from the exterior with a minimum of 6,000 possible key changes, or locking single dead bolt w/ hardened bolt insert. 2 All locks on exterior doors shall be capable or resisting a force of 300 pounds applied in any movable direction and in accordance with resistance standards set forth in the 2004 Florida Building Code. 3 The active leaf of a pair of exterior swinging doors shall have the same lock as required for a single exterior swinging door. The inactive leaf of these pair of doors shall have a multiple point lock with 5/8" minimum throw bolts with inserts. 4 Sliding glass doors shall be provided with sliding door dead bolts or a bolt or pin, not removable or operated from the exterior. At the jamb, head, sill or meeting mullions. These doors shall be constructed so that no panel can be lifted from the track when in a locked position. 5 Hinges on the exterior out swinging doors shall have non - removable pins. 6 .lambs of all exterior offset type, in- swinging doors shall be rabbeted or of a similar fabrication to maintain the integrity of locks and hatches. 7 Vision panels of exterior doors, other than glazing within 40" of the inside lock activating device, shall comply with ANSI 297.1. 8 Exterior swinging doors, if wood, shall be of 1 -3/4" thick solid core construction. SHEET LEGEND: AOS -01 -12 ADD LIFE SAFETY PLANS AO.0 COVER SHEET • ` FLOOR A3. I LIFE SAFETY PLAN - GROUND FLOOR A3.2 LIFE SAFETY ., • r FLOOR ..0 REFLECTED CEILING PLAN A7.0 WALL SECTIONS A8.0 INTERIOR ELEVATIONS . • 1 INTERIOR ELEVATIONS A10.0 SCHEDULES ENGINEERING: ME1.0 MECHANICAL, ELECTRICAL, PLUMBING SPECS M -1.0 MECHANICAL PLANS M -2.0 SCHEDULES AND DETAILS E1.0 POWER PLANS 8. Noted dimensions shall have precedence over scaled dimensions. The architect shall be E2.0 LIGHTING PLAN notified of any discrepancies before the start of work. The Architect must be notified in E3.0 PANEL SCHEDULES AND RISER DIAGRAMS writing if scaled dimensions are being used. E4.0 NOTES AND LEGEND 9. The General Contractor shall be responsible for all permits, fees, licenses, and taxes P1.0 SANITARY PLAN AND ISOMETRIC related to work. P2.0 WATER PLAN AND ISOMETRICS 10. General Contractor is responsible for all work provided by subcontractors of the various P3.0 NOTES, DETAILS, SCHEDULES, AND LEGENDS trades. 11. Surfaces to be painted shall be filled, sealed, and sanded and primed as required. Colors to be selected by the architect. Four test samples shall be made prior to execution of work. The architect shall also select colors of prefabricated products. 12. All intrusion preventing devices shall conform to the 2010 Florida Building Code. See security and forced entry notes. 13. General Contractor shall be responsible that architectural, structural, electrical, mechanical drawings are employed simultaneously in the construction of this project. Any discrepancies shall be reported to the architect immediately. 14. Contractor shall maintain a set of drawings at the project site with up to -date information on as -built conditions indicating with colored pens all changes and deviations from the contract drawings. This set of prints shall be turned over to the architect /engineer with the corresponding permits at the completion of the project as a pre - requisite for final payment. 15. No deviations of these plans are allowed except with written authorization from the architect. 16. Before submission of bid, the General Contractor shall visit the site and become familiarized with the existing conditions and notify the architect of any findings not addressed in the bid documents. 17. Lawful and proper disposal of all waste material shall be the responsibility of the General Contractor. 18. General Contractor shall take special precautions and coordinate with the owner that the building is secure at all times during the construction period. General Contractor shall coordinate construction schedule with owner and his security services prior to construction start. 19. Any demolition shall be in strict accordance with structural engineering requirements. Refer to shoring and demolition plans on the structural sheets. Special care shall be taken during the demolition and construction period that no damage will occur to anything in existing areas which was intended to remain. Any damage to existing construction to remain must be repaired by the general contractor at no cost to the owner. 20. No substitutions shall be permitted without written authorization of the Architect. 21. A/C should not run during construction so that dust does not permiate the duct and fan components. 22. Site must be vaccurned and dust free at the close of each working day. 4P ni n-rr_ a NO X -RAY EQUIPMENT, FILM DEVELOPMENT EQUIPMENT, OR CHEMICALS USED FOR PHOTO DEVELOPMENT WILL BE LOCATED ON SITE. NO RADIOACTIVE MATERIALS WILL BE USED. ONLY r LAB TESTS WILL BE CONDUCTED ON r r• NOT REQUIRE ANY LABORATORY EQUIPMENT. ALL BIOHAZARDOUS SAMPLES AND WASTE COLLECTED ON SITE WILL BE COLLECTED, STORED, AND SENT TO OUTSIDE LABS DAILY FOR ANALYSIS TRANSPORTER. OR DISPOSAL VIA A STATE APPROVED BIOHAZARDOUS WASTE A08-01-12 CHEMICAL AND BIOHAZARD NOTES A09-19-12 CHEMICAL AND BIOHAZARD NOTES OCCUPANCY TYPE: BUSINESS - OFFICE BASED SURGICAL FACILITY THIS IS NOT AN AMBULATORY FACILITY CLASS "C" REGULAR FACILITY - A MAXIMUM OF 3 PATIENTS WILL BE RENDERED INCAPABLE OF SELF - PRESERVATION UNDER EMERGENCY CONDITIONS WITHOUT THE ASSISTANCE OF OTHERS AT ANY ONE TIME. • MAXIMUM OCCUPANCY ANESTHETIZING LOCATIONS ARE TO COMPLY WITH THE REQUIREMENTS OF N FPA 99. AOS -01 -12 OCCUPANCY NOTES ARCHIaTECT: UPSTAIRSSTUDIO, INC. ARCHITECTURE Maricarmen Martinez, AIA Principal 3941 Midway Street Miami, Florida 33133 TEL (305) 447 -1907 FAX (305) 447 -1906 ENGINEER: RPJ, INC. RAFAEL PENA 4977 SW 74 COURT MIAMI, FL 33155 TEL (305) 666 -2131 FAX (305) 666 -0131 �. s 4. C a�F a4�a a a• .t .�.... fit d• ---- - - - - -- project: 1 i South Miami Advanced I i Center for Surgery I I DR. ALAN SERURE i i7330 00 2 PLACE SUITE I I SOUTH MIAMI, FL 33143 I L-------- - - - - -J tt MITI i APP YED Q::) revisions: D ar: DM MCM AOS -01 -1z A09-19-12 DAT . 09!19112 U C A m�e,� UPSTAIRS STUDIO A a"^° °b ® architecture Maricarmen Martinez, AIA a3941 Midway Street U Miami, Florida 33133 Q- Tel 305 447 -1907 Fax 305447 -1906 Q } e- mail: info @upstairsstudioarchitecture.com p FLORIDA LICENSE: AA 0003148 �. s 4. C a�F a4�a a a• .t .�.... fit d• ---- - - - - -- project: 1 i South Miami Advanced I i Center for Surgery I I DR. ALAN SERURE i i7330 00 2 PLACE SUITE I I SOUTH MIAMI, FL 33143 I L-------- - - - - -J tt MITI i