Loading...
12-669-006. SeeshaetA3.1. The adjoining sude/soaco8soccupied by the same suite omm/e,ltenamt and has its own designated egress doors, corridors, and sta[rs The door (#102) connecting the two spaces isformbeusemfohestaar - amthatrhey do not have toexit toa common corridor tmmove between the two suites. The suite being, constructed under this permit will have its own designated egress doors Door 102 is not anegress door for either suite. Comment #7 Indicate on plans the type of occupancy and the occupant load as per Table 7.3.1.2. See sheets As,aand A3.1- this isa Business Occupancy with amaximum occupancy mp28persons. Comment #8 Indicate on plans the use of all rooms orareas. See sheet w3.1- noted under room labels. ^ Comment #9 Provide complete life safety plans showing common path of travel - dead end distances - | travel distances - number of exits - exit capacities -etc. ! See sheet A3.1. ( Comment #10 Provide minimum required flame spread classification for interior finish - Table A.10.2.2. XXXXXX Comment #11 Provide aUL Approval Number for 1 hour rated tenant wall. XXXXXX Comment #12 Storage Room and Utility to be provided with a 1 hour fire rated enclosure and a 45 minute rated door with acloser. See sheets A3.0 and Al 0.0: Comment #13 Indicate in door schedule the rating of the following doors: existing corridor doors, #100, #1U2. See sheet A 10'0. Comment #I4 Doors shall swing in the direction of egress travel where serving a room or area with an occupant load of5Oor more persons. See sheets AO'0 and A3'1. Not applicable - maximum occupancy of28persons. Comment #15 Doors obstructing egress - Scc. 7.2.l.4.4-(#118and #124) See sheet A3.0 for revised doors. Comment #16 See engineer responses. Comment #17 See engineer responses. Comment #18 NO RESPONSE NEEDED, Feel free to call usif you have any questions or need further clarification. Sincenely, 0�7-carmen Martinez