10-201-047LEGEND QUAD. (DOUBLE DUPLEX) DUPLEX OUTLET (GROUNDING) -Q SINGLE OUTLET (GROUNDING) ® SPECIAL PURPOSE FLOOR BOX - TO BE RCI, MODEL BIG 2 ", UNLESS NOTED EXIT LIGHT 0 CEILING FIXTURE (TYPE INDICATED ON PLANS) �-o WALL MOUNTED FIXTURE (TYPE INDICATED ON PLANS) .-Q POLE LIGHT I--e FLUORESCENT STRIP O FLUORESCENT, UNLESS OTHERWISE NOTED � LIGHTING PANEL 9 J BOX MOTOR © DATA OUTLET ® STARTER, OR CONTROL PANEL W COMBINATION STARTER D DISCONNECT SWITCH - WP INDICATES WEATHERPROOF (TYP.) S SINGLE POLE SWITCH S3 THREE WAY SWITCH SB SERVICE BREAKER (FACTORY INSTALLED) A TELEPHONE OUTLET IJVVVU FLEXIBLE CONDUIT - — — - CONDUIT RUN EXPOSED — r�— CONDUIT CONCEALED IN WALLS OR OVERHEAD (SHOWN WITH TWO HOT & NEUTRAL) — CONDUIT IN OR UNDER THE SLAB (SHOWN WITH HOT, NEUTRAL & GROUND) E EXISTING TO REMAIN. ER EXISTING TO BE REMOVED. RE EXISTING REPLACED. 0 GENERAL NOTES (REFER TO DRAWING MEP -01 FOR ADDITIONAL SPECIFICATIONS) I- GENERAL CONDITIONS: THE GENERAL CONDITIONS FORM A PART OF THE SPECIFICATIONS FOR THIS TRADE. EACH SUB - CONTRACTOR MUST READ GENERAL CONDITIONS, AS WELL AS THE SPECIFICATIONS FOR WORK OF OTHER TRADES AND TO ASCERTAIN WHAT WORK AND MATERIALS HE MUST SUPPLY TO THE OTHER CONTRACTORS. 2- SITE INVESTIGATION: IT SHALL BE THE RESPONSABILITY OF BIDDERS TO VISIT THE SITE AND TO ACQUAINT THEMSELVES WITH AL INFORMATION REGARDING THE NEW BUILDING. 3- DESIGN: THE INSTALLATION OF THE WIRING SYSTEM SHOWN ON THESE DWGS. SHALL CONFORM TO THE REGULATIONS OF LOCAL CODES AND ORDINANCES, N.E.C. AND LOCAL UTILITY COMPANIES. 4- MINIMUM STANDARDS: THE MATERIAL, INSTALLATIONS AND WORKMANSHIP FURNISHED UNDER THIS SECTION SHALL CONFORM TO THE REQUIREMENTS OF LOCAL CODES AND N.E.C., ALL MATERIALS USED SHALL BE LISTED OR BEAR U.L. APPROVAL. 5— GUARANTEE: THIS SUB — CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE THAT ALL WORK EXECUTED UNDER THIS CONTRACT, SHALL BE FREE FROM DEFECTS OR WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR, AT CONTRACTOR'S EXPENSE, REPAIR AND REPLACE ALL WORK WHICH BECOMES DEFECTIVE DURING THE TIME OF THE GUARANTEE. 6- RACEWAYS AND FITTINGS: a) RIGID GALVANIZED : 1 -1/2" OR LARGER AND IN SLAB ABOVE GRADE. b) EMT : ALL OTHER LOCATION, (WITH COMPRESSION COUPLING FOR DAMP LOCATION). FITTING: TO MATCH THE APPROVED USED RACEWAY. 7- CONDUCTORS: THE MINIMUM CONDUCTOR NO. 12 SOLID CU. TYPE "THWN" INSULATION, NO MORE THAN THREE CURRENT- CARRYING CONDUCTORS SHALL BE INSTALLED IN A RACEWAY. 8- ALL EQUIPMENT LISTED ON DWGS. BY CATALOG NO. SHALL BE LIMITED TO THE KIND AND MANUFACTURE LISTED. NO SUBSTITUTION SHALL BE ALLOWED UNLESS APPROVED BY THE ENGINEER. A WRITTEN GUARANTEE OF THREE YEARS AND CREDIT FROM BASIC BID SHALL BE SUBMITTED WITH SHOP DRAWINGS. 9— CONTRACTOR TO INSTALL AND /OR CONNECT ALL EQUIPMENTS AND CONTROLS SUPPLIED BY OWNER, OR ANY OTHER TRADE. SEE OTHER TRADES DRAWINGS AND SPECIFICATIONS. 10- ALL FEEDERS AND BREAKERS SHALL BE COORDINATED WITH EQUIPMENT'S PLATE AT SITE. r n, R 6 0 )d t�.�g �RAFAE RA4JRE {` (18395) SOUTH MIAMI MEDICAL SQUARE 7330 S.W. 021ad ]PLACE SOUTH MIAMI, FLORIDA, 33 143 RPJ, INC. CONSULTING ENGINEERS 4977 S.W. 74th COURT MIAMI, FL. 33155 PHONE: (305) 666 -2131 FAX: (305) 666 -0131 DRAWING NO. DATE: E -5.0 01 -12 -10 OWNER: SOUTH MIAMI MEDICAL BUILDING ATTN: TEL: JOB NO. 08 -04"7