Loading...
10-201-043FOURTH FLOOR PLAN — NEW ELECTRICAL fu I SCALE: 3/I6" = I'—O" AAW m NORTH M V' G1 ,a 0 _N N N 61 N M N W d' 00 O u w J W i n O co O N LD LIGHTING FIXTURE SCHEDULE SA 2'X2' FLUOR. LAY —IN COFFAIRE TYPE. LIGHTOLIER CAT. #CF— S- 2— G— HP -3 -17- 120 - -GLR S2'X2' FLUOR. LAY —IN COFFAIRE TYPE. LIGHTOLIER CAT. #CF— S- 2— G— HP -3 -17 -120- -GLR WITH EMERGENCY BALLAST FBP50. SC BATHROOM WALL MOUNTED LIGHT FIXTURE. TO BE SELECTED BY INTERIOR DESIGNER /OWNER. AND TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. SD PROVIDE J —BOX FOR SURFACE MOUNTED LIGHT FIXTURE TO BE SELECTED BY INTERIOR DESIGNER /OWNER AND TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. ES DOWN LIGHT— LIGHTOLIER 2005WH- 2000LV— MR16 -50W -120 FSPROVIDE J —BOX FOR SURFACE MOUNTED LIGHT FIXTURE TO BE SELECTED BY INTERIOR DESIGNER /OWNER AND TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. SWALL MOUNTED STAIR LIGHT LIGHTOLIER CAT. #LSW- 4- 2- 32- 120 —LE —GLR SX EDGE —LIT EXIT SIGN WITH BATTERY PACK, LIGHTOLIER LU SERIES, SY EMERGENCY LIGHT WITH BATTERY PACK CHLORIDE GM3 SERIES— WHITE —AD KEY NOTES: S EXISTING EXIT SIGN TO BE DISCONNECTED AND REPLACED. PROVIDE NEW EXIT SIGN WITH BATTERY PACK. S EXISTING F/A PULL STATION TO BE REPLACED WITH NEW PULL STATION, Q EXISTING F/A HORN WITH STROBE LIGHT TO BE REPLACED WITH NEW HORN WITH STROBE LIGHT. S4 PROVIDE NEW F/A SMOKE DETECTOR AT NEW CEILING TO BE CONNECTED TO THE EXISTING ALARM CIRCUIT OF THE OLD SMOKE DETECTOR THAT WAS DISCONNECTED AND REMOVED. S5 EXISTING F/A STROBE LIGHT TO BE REPLACED WITH NEW STROBE LIGHT. S6 NEW D.F. TO BE CONNECTED TO THE EXISTING CIRCUIT, WITH 2 #12 THWN CU IN 1/2" C. S EXISTING VAV —BOX AT CLG. SPACE TO BE REPLACED, AND NEW TO BE CONNECTED TO EXISTING CIRCUIT. S CONNECT NEW CORRIDOR /LOBBY LIGHTS TO THE EXISTING CIRCUIT.(1P -20 AMPS BRK.) WITH 2 #12 THWN CU IN 1/2" C. S NEW 2'X2' FLUORESCENT LIGHT. FIXTURE TO BE PROVIDED WITH EMERGENCY BALLAST. 10 NEW VAV —BOX TO BE CONNECTED TO NEW PANEL -4D. EXIST' WIRING AND CONDUIT FOR THE EXISTING VAV —BOX THAT WILL BE REPLACED SHALL BE DISCONNECTED AND REMOVED, 11 NEW STAIR LIGHT FIXTURE TO REPLACE EXISTING AND TO BE CONNECTED TO THE EXISTING STAIR LIGHT CIRCUIT, WITH 2 #12 THWN CU IN 1/2" C. 12 NEW STAIR EMERGENCY LIGHT WITH BATTERY PACK TO REPLACE EXISTING AND TO BE CONNECTED TO THE EXISTING STAIR EMERGENCY LIGHT CIRCUIT WITH 2 #12 THWN CU IN 1/2" C. 13 NOT USED. 14 EXISTING F/A ELEVATOR RECALL SIGN TO BE REPLACED. FIRE ALARM LEGEND: 10 RE EXISTING FIRE ALARM PULL STATION SHALL BE REPLACED AND NEW PULL STATION SHALL BE RECONNECTED TO THE EXISTING FIRE ALARM SYSTEM. G.E GENESIS SIGA -278. Q EXISTING FIRE ALARM HORN WITH STROBE LIGHT RE SHALL BE REPLACED AND NEW HORN WITH STROBE LIGHT SHALL BE RECONNECTED TO THE EXISTING FIRE ALARM SYSTEM. G.E GENESIS SERIES G1 (75 cd) COLOR WHITE. Q EXISTING FIRE ALARM STROBE LIGHT SHALL BE RE REPLACED AND NEW STROBE LIGHT SHALL BE RECONNECTED TO THE EXISTING FIRE ALARM SYSTEM. G.E GENESIS SERIES (15 cd) COLOR WHITE. �S PROVIDE NEW SMOKE DETECTOR, TO BE CONNECTED N TO THE EXITING ALARM CIRCUIT OF THE OLD SMOKE DETECTOR THAT WAS DISCONNECTED AN REMOVED. G.E. CONVENTIONAL SMOKE DETECTOR EC30U -3 NOTE_ NEW DEVICES SHALL BE COMPATIBLE WITH THE EXISTING FIRE ALARM SYSTEM, AND CONNECTED AS PER THE EXISTING FIRE ALARM SYSTEM SPECIFICATIONS. �y s '.I RAF EL PE d�n „d, ; �; f JR.' .(1 395) Rq h i? 4 e" i✓ u i" b i 8 0iLv, COWIFL.IAN s WI i IA N.F%IPA. 12 AND F.A.G. 61G 05-32.006 (iDESI(;N OF ALJt`ARIA SYST PASS) A TI-Ii'U P. A COPY OF lNL_BE APPROVLD DPAVVINGS MUST BE SUBN]ITTED VVITH PiE Si 10 P Dr?AV4WiNGS ROft Pl_#'lA�il_F A PROVAL. ,y DATE. . w )wllI �i'i�+la�`i`�'�.���'��`���:�� `- r4y `.`i: i ,..e."ar i.:rlxvfr ^mdwa:�:�v.Y:+B`dua SOUTH MIAMI MEDICAL SQUARE 7330 S.W. 02114 PLACE SOUTH MIAMI, FLORIDA, 33 143 R P J 9 INC. OWNER: y TING ENGINEERS SOUTH MIAMI MEDICAL C,ONS�CTI� BUILDING 4977 S.W. 74th COURT MIAMI, FL. 33155 ATTN: PHONE: (305) 666 -2131 TEL: FAX: (305) 666 -0131 DRAWING NO. DATE: JOB NO. E -2.3 101-12-10 08°047