Loading...
10-201-0420 V) ro ro 0 Q co 0 0 N M N W h Q b .. W J W n d' O 00 O N C� Igo THIRD FLOOR PLAN - NEW ELECTRICAL SCALE: 3/16" = 1' -0" _ ]NORTH i/ LIGHTING FIXTURE SCHEDULE OA 2'X2' FLUOR. LAY —IN COFFAIRE TYPE. LIGHTOLIER CAT. #CF— S- 2— G— HP -3 -17- 120 - -GLR D2'X2' FLUOR, LAY —IN COFFAIRE TYPE. LIGHTOLIER CAT. #CF— S- 2— G— HP -3 -17- 120 - -GLR WITH EMERGENCY BALLAST FBP50. (C BATHROOM WALL MOUNTED LIGHT FIXTURE. TO BE SELECTED BY INTERIOR DESIGNER /OWNER. AND TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. OD PROVIDE J —BOX FOR SURFACE MOUNTED LIGHT FIXTURE TO BE SELECTED BY INTERIOR DESIGNER/OWNER AND TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. O DOWN LIGHT — LIGHTOLIER 2005WH- 2000LV— MR16- 50W -12 OPROVIDE J —BOX FOR SURFACE MOUNTED LIGHT FIXTURE TO BE SELECTED BY INTERIOR DESIGNER /OWNER AND TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. �G WALL MOUNTED STAIR LIGHT LIGHTOLIER CAT. #LSW- 4 -2 -32- 120 —LE —GLR O EDGE —LIT EXIT SIGN WITH BATTERY PACK. LIGHTOLIER LU SERIES. OY EMERGENCY LIGHT WITH BATTERY PACK CHLORIDE GM3 SERIES — WHITE —AD KEY NOTES: EXISTING EXIT SIGN TO BE DISCONNECTED AND REPLACED WITH NEW EXIT SIGN WITH BATTERY PACK. O2 EXISTING F/A PULL STATION TO BE REPLACED WITH NEW PULL STATION. O3 EXISTING F/A HORN WITH STROBE LIGHT TO BE REPLACED WITH NEW HORN WITH STROBE LIGHT. ® PROVIDE NEW F/A SMOKE DETECTOR AT NEW CEILING TO BE CONNECTED TO THE EXISTING ALARM CIRCUIT OF THE OLD SMOKE DETECTOR THAT WAS DISCONNECTED AND REMOVED. �5 EXISTING F/A ELEVATOR RECALL SIGN TO BE REPLACED. © EXISTING F/A STROBE LIGHT TO BE REPLACED WITH NEW STROBE LIGHT, O7 NEW D.F. TO BE CONNECTED TO THE EXISTING CIRCUIT. WITH 2 #12 THWN CU IN 1/2" C. 8G EXISTING VAV —BOX AT CLG. SPACE TO BE REPLACED, AND NEW TO BE CONNECTED TO EXISTING CIRCUIT. ® CONNECT NEW CORRIDOR /LOBBY LIGHTS TO EXISTING LIGHT CIRCUIT. EM -11 (1P -20 AMPS BRK.) WITH 2 #12 THWN CU IN 1/2" C. 10 NEW 2'X2' FLUORESCENT LIGHT, FIXTURE TO BE PROVIDED WITH EMERGENCY BALLAST. 11 EXISTING E.W.H. TO BE RELOCATED, ADJUST EXISTING ELECT. INSTALLATION IF NECESARY AS PER THE NEW CLOSET LAY —OUT. 12 NEW LIGHT FIXTURES SHALL BE CONNECTED TO THE EXISTING RESTROOM LIGHT CIRCUIT WITH 2 #12 THWN CU IN 1/2" C. 13 NEW DUCT SMOKE DETECTOR TO BE CONNECTED TO EXISTING SHUT DOWN /VISUAL ALARM/ RESET BUTTOM. 14 NEW VARIABLE FRECUENCY DRIVE (SEE RISER) 15 NEW STAIR LIGHT FIXTURE TO REPLACE EXISTING AND TO BE CONNECTED TO THE EXISTING STAIR LIGHT CIRCUIT, WITH 2 #12 THWN CU IN 1/2" C. 16 NEW STAIR EMERGENCY LIGHT WITH BATTERY PACK TO REPLACE EXISTING AND TO BE CONNECTED TO THE EXISTING STAIR EMERGENCY LIGHT CIRCUIT WITH 2 #12 THWN CU IN 1/2" C. 17 PROVIDE TWO (2) 1 -1/2" EMT CONDUITS WITH PULL STRINGS FROM CEILING SPACE ABOVE THE SUITE 310 LOBBY TO THE 3RD FL. ELECTRICAL ROOM ABOVE THE EXIST'G PANELS —C & 2C FOR FUTURE USE, FIRE ALARM LEGEND: 10 RE EXISTING FIRE ALARM PULL STATION SHALL BE REPLACED AND NEW PULL STATION SHALL BE RECONNECTED TO THE EXISTING FIRE ALARM SYSTEM. G.E GENESIS SIGA -278. 10 RE EXISTING FIRE ALARM HORN WITH STROBE LIGHT SHALL BE REPLACED AND NEW HORN WITH STROBE LIGHT SHALL BE RECONNECTED TO THE EXISTING FIRE ALARM SYSTEM. G.E GENESIS SERIES G1 (75 cd) COLOR WHITE. Eg EXISTING FIRE ALARM STROBE LIGHT SHALL BE RE REPLACED AND NEW STROBE LIGHT SHALL BE RECONNECTED TO THE EXISTING FIRE ALARM SYSTEM, G.E GENESIS SERIES (15 cd) COLOR WHITE. US PROVIDE NEW SMOKE DETECTOR, TO BE CONNECTED N EXITING ALARM CIRCUIT DETECTOR THAT WAS DISCONNECTED AN REMOVED. G.E. CONVENTIONAL SMOKE DETECTOR EC30U -3 NOTE: NEW DEVICES SHALL BE COMPATIBLE WITH THE EXISTING FIRE ALARM SYSTEM, AND CONNECTED AS PER THE EXISTING FIRE ALARM SYSTEM SPECIFICATIONS. E �� '1 X3.13 �_ `� • c AFAEL ENA, JR. ( 6395) APPROVED By y bra 3 ,..i' `' ,J a 7. >_ AND 1° A. Ce. fT V'RtJ E A COPY Cr Ill-ESE APPa"ZOVED DFA' ;vii UNCS- 1VIRJ Y f DF' SU Rill h'ED V"VI 1 i l T9 lr7 3�10P 1. RAlfiJi�l(38 FOR P_- �'ar��'y?��1'��L. SOUTH MIAMI MEDICAL SQUARE 7330 S.W. 02nd PLACE SOUTH MIAMI9 FLORIDA, 33143 R P J 9 INC - OWNER: CONSULTING ENGINEERS SOUTH MIAMI MEDICAL 4977 S.W. 74th COURT BUILDING MIAMI, FL. 33155 ATTN: PHONE: (305) 666 -2131 TEL: FAX: (305) 666 -"0131 DRAWING NO. DATE: JOB NO. E -2.2 101-12-10 08 -047