10-201-041L fa fa N 4 w u Q 0 N 2 0 N _N N� N N w 00 0 W J W 00 N c7 SECOND FLOOR PLAN - NEW ELECTRICAL SCALE: 3/16"= I`0" _ ]NORTH LIGHTING FIXTURE SCHEDULE OA 2'X2' FLUOR, LAY -IN COFFAIRE TYPE. LIGHTOLIER CAT. #CF- S- 2- G- HP- 3- 17- 120 - -GLR O2'X2' FLUOR, LAY -IN COFFAIRE TYPE. LIGHTOLIER CAT. #CF- S- 2- G- HP -3 -17 -120- -GLR WITH EMERGENCY BALLAST FBP50. �C BATHROOM WALL MOUNTED LIGHT FIXTURE. TO BE SELECTED BY INTERIOR DESIGNER /OWNER. AND TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. OPROVIDE J -BOX FOR SURFACE MOUNTED LIGHT FIXTURE TO BE SELECTED BY INTERIOR DESIGN%OWNER AND TO BE PROVIDED AND INSTALLED BY ELECT CONTRACTOR. O DOWN LIGHT- LIGHTOLIER 2005WH- 2000LV- MR16 -50W -1 OPROVIDE J -BOX FOR SURFACE MOUNTED LIGHT FIXTURE TO BE SELECTED BY INTERIOR DESIGNER OWNER AND TO BE PROVIDED AND INSTALLED BY ELECT ICAL CONTRACTOR. O WALL MOUNTED STAIR LIGHT LIGHTOLIER CAT. #LSW- 4 -2 -32- 120 -LE -GLR O EDGE -LIT EXIT SIGN WITH BATTERY PACK. LIGHTOLIER LU SERIES. O EMERGENCY LIGHT WITH BATTERY PACK CHLORIDE GM3 SERIES - WHITE -AD KEY NOTES: 1U CONNECTED EXISTING D.F. TO BE REMOVED. EXISTING ELECT. INSTALLATION SHALL BE DISCONNECTED AND REMOVED. EXISTING EXIT SIGN TO BE DISCONNECTED. REPLACED PROVIDE NEW EXISTING W /BATTERY PACK. 0 EXISTING EMERGENCY LIGHT TO BE DISCONNECTED AND BE REPLACED WITH NEW EMERGENCY LIGHT FIXTURE WITH BATTERY PACK. ® EXISTING F/A PULL STATION TO BE REPLACED WITH NEW PULL STATION. O EXISTING F/A HORN WITH STROBE LIGHT TO BE REPLACED WITH NEW HORN WITH STROBELIGHT. © PROVIDE NEW F/A SMOKE DETECTOR AT NEW CEILING TO BE CONNECTED TO THE EXISTING ALARM CIRCUIT OF THE OLD SMOKE DETECTOR THAT WAS DISCONNECTED AND REMOVED. �7 EXISTING F/A ELEVATOR RECALL SIGN TO BE REPLACED. ® EXISTING F/A STROBE LIGHT TO BE REPLACED. NEW D.F. TO BE CONNECTED TO THE EXISTING CIRCUIT, 10 EXISTING VAV -BOX AT CLG, SPACE TO BE REPLACED AND NEW TO BE CONNECTED TO EXISTING CIRCUIT. @ CONNECTED NEW CORRIDOR /LOBBY LIGHTS TO THE EXISTING LIGHT CIRCUIT 2B -15 (1P -20 AMPS BRK.) WITH 2 #12 THWN CU IN 1/2" C. 12 NEW 2'X2' FLUORESCENT LIGHT FIXTURE TO BE PROVIDED WITH EMERGENCY BALLAST. 13 EXISTING VAV -BOX AT CLG. SPACE TO BE REPLACED AND THE NEW VAV -BOX TO BE CONNECTED TO THE NEW 2P -40 AMPS CKT. BRK. (213- 28,30) WITH 3 #8 THWN CU IN 3/4" C. 14 EXISTING VAV -BOX AT CLG. SPACE TO BE REPLACED AND THE NEW VAV -BOX TO BE CONNECTED TO THE NEW 2P -40 AMPS CKT. BRK. (2B- 32,34) WITH 3 #12 THWN CU IN 1/2" C. 15 NEW DUCT SMOKE DETECTOR TO BE CONNECTED TO EXISTING SHUNT DOWN /VISUAL ALARM /RESET BUTTOM. 16 NEW VARIABLE FRECUENCY DRIVE (SEE RISER AND MECHANICAL DRAWINGS), 17 NEW STAIR LIGHT FIXTURE TO REPLACE EXISTING AND TO BE CONNECTED TO THE EXISTING STAIR LIGHT CIRCUIT, WITH 2 #12 THWN CU IN 1/2" C. 18 NEW STAIR EMERGENCY LIGHT WITH BATTERY PACK TO REPLACE EXISTING AND TO BE CONNECTED TO THE EXISTING STAIR EMERGENCY LIGHT CIRCUIT WITH 2 #12 THWN CU IN 1/2" C. 19 NOT USED. FIRE ALARM LEGEND: 10 RE EXISTING FIRE ALARM PULL STATION SHALL BE REPLACED AND NEW PULL STATION SHALL BE RECONNECTED TO THE EXISTING FIRE ALARM SYSTEM. G.E GENESIS SIGA -278. ❑F RE EXISTING FIRE ALARM HORN WITH STROBE LIGHT SHALL BE REPLACED AND NEW HORN WITH STROBE LIGHT SHALL BE RECONNECTED TO THE EXISTING FIRE ALARM SYSTEM. G.E GENESIS SERIES Cl (75 cd) COLOR WHITE. Q EXISTING FIRE ALARM STROBE LIGHT SHALL BE RE REPLACED AND NEW STROBE LIGHT SHALL BE RECONNECTED TO THE EXISTING FIRE ALARM SYSTEM G.E GENESIS SERIES (15 cd) COLOR WHITE. S� PROVIDE NEW SMOKE DETECTOR, TO BE CONNECTED N TO THE EXITING ALARM CIRCUIT OF THE OLD SMOKE DETECTOR THAT WAS DISCONNECTED AN REMOVED. G.E. CONVENTIONAL SMOKE DETECTOR EC30U -3 NOTE: NEW DEVICES SHALL BE COMPATIBLE WITH THE EXISTING FIRE ALARM SYSTEM. AND CONNECTED AS PER THE EXISTING FIRE ALARM SYSTEM SPECIFICATIONS. AFACL" E, A; JR r•• (16390 vy, t I I J Sj�_BLDG. PERM WATE,R MAIN PXTE NSION w SOUTH MIAMI 7330 ' S.W. SOUTH MIAMI, MEDICAL SQUARE 02Td PLACE FLORIDA, 33143 R PJ, INC. CONSULTING ENGINEERS 4977 S.W. 74th COURT MIAMI, FL. 33155 PHONE: (305) 666 -2131 FAX: (305) 666 -0131 DRAWING- NO. I DATE: E -2.1 01 -12 -10 OWNER: SOUTH MIAMI MEDICAL BUILDING ATTN: TEL: JOB NO. 08 -04'7