10-201-028C ro U N co 0 CD 0 N N N ai m Q cQ O. U Q 2 s III THIRD FLOOR CEILING PLAN - HVAC SCALE: 3/16" = I " -O" _ NORTH LEGEND SYMBOL DESCRIPTION GT THERMOSTAT EEEE3 • RETURN AIR OPENING W/ FIRE DAMPER FD EE::�:]] VAV VARIABLE AIR VOLUME BOX CA VAV VARIABLE AIR VOLUME BOX W/ ELECT. HEATER (E) EXISTING VD VOLUME DAMPER A.H.U. AIR HANDLING UNIT S.A. SIPPLY AIR DUCT R. A. RETURN AIR DUCT (N) NEW 0. A. OUTSIDE AIR �9 FLEXIBLE S.A. DUCT. REMOVE ALL EXISTING WIRE LINES CROSSING THROUGH ALL EXISTING TRANSFER DUCTS ON CORRIDOR OR MECHANICAL ROOM WALL. CEILING IS A RETURN AIR PLENUM, NO COMBUSTIBLES ALLOWED. KEY NOTES -HVAC 10 NEW AHU -2. REFER TO AIR HANDLING UNIT SCHEDULE. �2 EXISTING WALL MOUNTED TRANSFER DUCT W /FIRE DAMPER. U3 EXISTING TOILET EXHAUST GRILLE TO BE REMOVED. EXTEND EXISTING 12X4 EXHAUST DUCT AS REQUIRED TO NEW CEILING REGISTER. �4 EXISTING REFRIGERANT PIPING IN CEILING SPACE. RECONNECT TO NEW AHU -2. ALL DUCT PENETRATIONS THRU FIRE RATED WALL SHALL BE FIRE SEALED TO MAINTAIN WALL FIRE RATED INTEGRITY. © NEW VAV BOX. REFER TO VAV SCHEDULE. �7 EXISTING OUTSIDE AIR INTAKE LOUVER. ® EXISTING 16X14 OUTSIDE AIR INTAKE DUCT TO MECHANICAL ROOM WITH FIRE DAMPER AT WALL PENETRATION. �9 EXISTING THERMOSTAT, TO BE REMOVED. 10 EXISTING SUPPLY AIR MAIN DUCT TO REMAIN. 11 TIE -IN NEW 8 "X10" DUCT TO EXISTING 24 "X12" S.A DUCT. TIE -IN EXISTING 80 FLEXIBLE TO NEW DUCT. 12 EXISTING DUCT SMOKE DETECTOR. 13 EXISTING S.A. DIFFUSER TO BE REMOVED. INSTALL NEW AS SPECIFIED. 14 EXISTING TOILET EXHAUST DUCT RISER TO REMAIN AS IS. 15 EXISTING TRANSFER DUCT TO BE REMOVED AND PATCH WALL OPENING TO MAINTAIN WALL FIRE RATED INTEGRITY. 16 EXISTING S.A. DUCTWORK TO BE REMOVED. BLANK -OFF DUCT OPENING AIR TIGHT. 17 CONTRACTOR TO REMOVE EXISTING VAV BOX AND RELATED FLEX SUPPLY DUCT AND PROVIDE NEW AS SPECIFIED. REMOVE EXISTING THERMOSTAT AND INSTALL NEW THERMOSTAT. COORDINATE LOCATION OF THERMOSTATS WITH TENANTS BEFORE INSTALLATION. 18 CONTRACTOR TO REPLACE / REPAIR EXISTING DUCT LEAK. 19 CONTRACTOR TO REMOVE ALL EXISTING SUPPLY RUNOUTS FROM EXISTING SUPPLY AIR MAIN DIRECTLY CONNECTED TO CEILING DIFFUSER. RECONNECT SUPPLY RUNOUT TO SUPPLY DUCT DOWNSTREAM OF CLOSET VAV BOX. t ArAE RA A (16395) SOUTH MIAMI MEDICAL SQUARE 7330 S.W. 02rid ]PLACE SOUTH MIAMI, FLORIDA, 33143 R P J 9 INC. OWNER: CONSULTINNG ENGINEERS SOUTH MIAMI MEDICAL BUILDING 4977 S.W. 74th COURT MIAMI, FL. 33155 ATTN: PHONE: (305) 666 -2131 TEL: FAX: (305) 666 -0131 DRAWING NO. AC-03 DATE: 01 -12 -10 JOB NO. 08 -04'7