Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13-205-021
1' DEMOLITION NOTES. 1. REFER TO TITLE SHEETS FOR ADDITIONAL GENERAL NOTES THAT ARE REQUIRED AND APPLY TO THE DEMOLITION PHASE. 2. CONTRACTOR TO FIELD VERIFY EXTENT OF PARTITIONS SCHEDULED FOR REMOVAL U.O.N. 3. CONTRACTOR TO COORDINATE ALL ASPECTS OF DEMOLITION AND NOTIFY ARCHITECT OF ANY DISCREPANCIES /CONFLICTING CONDITIONS INTERFERING W /COMPLETION OF THE WORK. 4. CONTRACTOR IS RESPONSIBLE FOR REMOVAL OF ALL DEBRIS, DISCARDED MATERIAL, AND EQUIPMENT AS INDICATED. 5. CONTRACTOR IS TO COORDINATE & COMPLY W /ALL LANDLORD REGULATIONS & CITY LAWS. 6. CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING ITEMS TO REMAIN. 7. CONTRACTOR IS RESPONSIBLE FOR ANY EXISTING CONSTRUCTION DAMAGE DUE TO DEMOLITION. 8. REFER TO PHASING PLAN FOR COORDINATION OF DEMOLITION. 9. EXISTING CARPET FINISH TO BE REMOVED. U.O.N. 10. EXISTING BAMBOO FLOORING TO BE PARTIALLY REMOVED. CONTRACTOR TO FIELD VERIFY EXACT EXTENT. 11, EXISTING FURNITURE AND EQUIPMENT TO BE REMOVED AND /OR STORED BY OWNER. CONTRACTOR, OWNER AND ARCHITECT TO COORDINATE DATE WHEN ALL FURNITURE AND EQUIPMENT IS REQUIRED TO BE REMOVED FOR EACH DEMOLITION PHASE. 12, EXISTING WOOD BASE TO REMAIN. PATCH AND REPAIR AS REQ'D TO RECEIVE NEW SCHEDULE BASE. 13. EXISTING OUTLETS TO REMAIN. REFER TO A -300s AND ELECTRICAL DWGS FOR RELOCATION OF EXISTING OUTLETS. G 14. EXISTING ROUGH CONCRETE FINISH ON COLUMNS, EXTERIOR WALLS AND SOFFITS TO REMAIN. LEGEND DEMOLITION KEYNOTES t EXISTING FLOOR FINISH TO BE REMOVED AND PREPARED TO RECEIVE NEW FINISH. Ir EEP SUBFLOOR AS RE 'D TO RECEIVE NEW SCHEDULED FINISH. j� EXISTING PARTITION TO BE REMOVED VERIFY EXTENT IN— FIELD. CONTRACTOR TO PATCH AND REPAIR EXISTING ADJACENT / PERPENDICULAR WALL TO REMAIN AND PREPARE SURFACE TO RECEIVE SCHEDULED FINISH. OREMOVE EXISTING WOOD SLATS AND BACK —UP FRAMING FOR VALANCE WHERE IT APPLIES. EXISTING BLIND ASSEMBLY AT ALL EXTERIOR WINDOWS TO REMAIN. PROTECT BLINDS DURING CONSTRUCTION. / EXISTING DOOR & FRAME ASSEMBLY TO BE REMOVED. L DEMOLITION KEYNOTES (CONTINUED) OEXISTING DOOR & FRAME ASSEMBLY TO BE REMOVED. CONTRACTOR TO PREPARE OPENING TO RECEIVE NEW DOOR AND FRAME ASSEMBLY. OEXISTING ROCK FINISH AND FRAMING ASSEMBLY TO BE REMOVED BACK TO DEMISING PARTITION. CONTRACTOR TO VERIFY EXTENT IN —FEILD AND PREPARE DEMISING PARTITION TO RECEIVE NEW FINISH. OEXISTING GLASS FRONTS AND DOORS TO BE REMOVED AND RETURNED TO ORIGINAL MANUFACTURER, 4TH FLOOR — DIRTT SYSTEMS AND 5TH FLOOR — STEELCASE. EXISTING HEADER TO BE REMOVED VERIFY EXTENT IN —FEILD AND BASED ON CONSTRUCTION PLANS. EXISTING SHELVING & FRAMING ASSEMBLY TO BE REMOVED BACK TO DEMISING PARTITION. CONTRACTOR TO VERIFY EXTENT IN —FEILD AND PREPARE DEMISING PARTITION RECEIVE NEW FINISH. OEXISTING THERMOSTAT TO BE RELOCATED. REFER TO MECHANICAL DRAWINGS FOR ADD'L INFO. t 0 EXISTING FISH TANK ASSEMBLY TO BE REMOVED BY OWNER PRIOR TO DEMOLITION WORK. t t LINE OF EXISTING FLOOR FINISH TO REMAIN. t 2 EXISTING CARPET TILE FLOOR FINISH TO BE REMOVED. EXISTING BAMBOO FLOOR BELOW TO REMAIN. CLEAN SURFACE. t 3 EXISTING TERRAZZO FLOORING TO REMAIN AND BE PROTECTED DURING DEMOLITION AND CONSTRUCTION. 14 EXISTING PLUMBING FIXTURES TO BE REMOVED. CAP PLUMBING LINES IN —ORDER TO BE RECOMMISSIONED AT LATER DATE. PANTRY SINK LINE MOVED INTO ADJACENT WALL. REFER TO PLUMBING DRAWINGS ON WHICH WATERLINES AND DRAINAGE LINES ARE BEING REPURPOSED FOR NEW CONSTRUCTION. S 15 EXISTING LOW PARTITIONS TO BE REMOVED BY CONTRACTOR. t 6 EXISTING SOFFIT TO REMAIN t 7 EXISTING FLOORING AND WALL BASE TO REMAIN. t LINE OF BAMBOO FLOORING TO REMAIN. COORDINATE EXACT LOCATION WITH FINISH PLAN AND WITH GLASS FRONTS SHOP DRAWINGS. DEMOLITION KEYNOTES (CONTINUED) t REMOVE PARTITION /SOFFIT TO ALIGN WITH EXISTING GWB CEILING IN EXISTING ROOM 102. PATCH AND REPAIR AS REG'D. REFER TO REFLECTED CEILING PLAN FOR ADD'L INFO. 20 EXISTING DOOR TO REMAIN 21 EXISTING CABINETRY, PLUMBING FIXTURES AND COUNTERTOP TO BE REMOVED AND WALLS AND PLUMBING SYSTEMS PREPARED FOR NEW SCHEDULED CABINETRY, FIXTURES AND FINISHES. CONTRACTOR TO COORDINATE WITH CLIENT ON STORAGE AND /OR REMOVAL OF EXISTING APPLIANCES. 22 EXISTING DOOR THRESHOLD TO REMAIN. 23 EXISTING TILED WALL FINISH TO BE REMOVED BACK TO DEMISING PARTITION AND /OR INTERIOR PARTITION. PATCH AND PREPARE SURFACE TO RECEIVE NEW FINISH. 24 EXISTING ROLLING MANUAL SHADES TO REMAIN, 25 EXISTING FINISHED CEILING AND LIGHT FIXTURES TO REMAIN. err CONTRACTOR TO CAREFULLY REMOVE EXISTING LIGHT FIXTURES AND DIFFUSERS. STORE FOR REUSE. REFER TO REFLECTED CEILING PLAN FOR ADD'L INFO. REMOVE EXISTING CEILING GRID. 27 REMOVE ALL LIGHT FIXTURES AND HANGING CEILING SYSTEM IN THIS AREA 2i EXISTING CEILING CANOPY / LIGHT FIXTURE TO REMAIN. 2'J EXISTING GWB SOFFIT TO BE REMOVED. O3o CONTRACTOR TO CAREFULLY REMOVE EXISTING JET NOZZLE WALL DIFFUSERS (SUPPLY & RETURN). CLEAN, REPAIR AS REQ'D & REINSTALL PER MECHANICAL DWGS. 31 LINE OF SOFFIT TO REMAIN. EXISTING HVAC DIFFUSERS TO REMAIN AND REPURPOSED INTO THE UPDATED HVAC SYSTEM. PROTECT DURING DEMOLITION. 32 EXISTING EXIT SIGNS TO REMAIN. REFER TO RCPs FOR ADD'L INFO. 33 EXISTING WATERLINE TO REMAIN. REFER TO PLUMBING DRAWINGS FOR ADD'L INFO. 34 EXISTING WALL MOUNTED AIR — CONDITIONER UNIT AND REMOTE CONTROL TO REMAIN. PROTECT DURING CONSTRUCTION. REPLACE FILTER AND CLEAN AS REQUIRED. 1 a` ..• Osseo *see 0 got • • c y v INDICATES AREAS NC �^ INDICATES EXISTING CONSTRUCTION TO REMAIN. INDICATES EXISTING CONSTRUCTION TO BE REMOVED. a• • INDICATES EXISTING DOOR AND FRAME ASSEMBLY TO BE REMOVED. NORBERTO ROSENSTEIN INDICATES AREA OF CONCRETE SLAB TO BE CUT AND REMOVED. REFER , TO STRUCTURAL DWGS FOR ADD'L INFO. COORDINATE EXACT LOCATION 126 S. FEDERAL HIGHWAY IN— FIELD. DANIA BEACH, FLORIDA 33004 INDICATES AREA OF BAMBOO FLOORING TO BE CUT AND REMOVED. REFER FAX: (954) 922 -7388 TO FINISH PLAN FOR ADD'L INFO. COORDINATE EXACT LOCATION IN FIELD. WEB: www.rosensteinarchitect.com INDICATES AREA OF GWB SOFFIT TO BE CUT AND REMOVED. REFER TO NATL.. REG. NO. 69178 REFLECTED CEILING PLAN FOR ADD'L INFO, COORDINATE EXACT LOCATION NORIERTO ROSENSTEIN ARCHITECT, INC. IN FIELD. OR PARTS THEREOF, MAY NOT BE REPRODUCED DENOTES KEYNOTE DENOTES FINISHED SURFACES TO ALIGN DEMOLITION KEYNOTES t EXISTING FLOOR FINISH TO BE REMOVED AND PREPARED TO RECEIVE NEW FINISH. Ir EEP SUBFLOOR AS RE 'D TO RECEIVE NEW SCHEDULED FINISH. j� EXISTING PARTITION TO BE REMOVED VERIFY EXTENT IN— FIELD. CONTRACTOR TO PATCH AND REPAIR EXISTING ADJACENT / PERPENDICULAR WALL TO REMAIN AND PREPARE SURFACE TO RECEIVE SCHEDULED FINISH. OREMOVE EXISTING WOOD SLATS AND BACK —UP FRAMING FOR VALANCE WHERE IT APPLIES. EXISTING BLIND ASSEMBLY AT ALL EXTERIOR WINDOWS TO REMAIN. PROTECT BLINDS DURING CONSTRUCTION. / EXISTING DOOR & FRAME ASSEMBLY TO BE REMOVED. L DEMOLITION KEYNOTES (CONTINUED) OEXISTING DOOR & FRAME ASSEMBLY TO BE REMOVED. CONTRACTOR TO PREPARE OPENING TO RECEIVE NEW DOOR AND FRAME ASSEMBLY. OEXISTING ROCK FINISH AND FRAMING ASSEMBLY TO BE REMOVED BACK TO DEMISING PARTITION. CONTRACTOR TO VERIFY EXTENT IN —FEILD AND PREPARE DEMISING PARTITION TO RECEIVE NEW FINISH. OEXISTING GLASS FRONTS AND DOORS TO BE REMOVED AND RETURNED TO ORIGINAL MANUFACTURER, 4TH FLOOR — DIRTT SYSTEMS AND 5TH FLOOR — STEELCASE. EXISTING HEADER TO BE REMOVED VERIFY EXTENT IN —FEILD AND BASED ON CONSTRUCTION PLANS. EXISTING SHELVING & FRAMING ASSEMBLY TO BE REMOVED BACK TO DEMISING PARTITION. CONTRACTOR TO VERIFY EXTENT IN —FEILD AND PREPARE DEMISING PARTITION RECEIVE NEW FINISH. OEXISTING THERMOSTAT TO BE RELOCATED. REFER TO MECHANICAL DRAWINGS FOR ADD'L INFO. t 0 EXISTING FISH TANK ASSEMBLY TO BE REMOVED BY OWNER PRIOR TO DEMOLITION WORK. t t LINE OF EXISTING FLOOR FINISH TO REMAIN. t 2 EXISTING CARPET TILE FLOOR FINISH TO BE REMOVED. EXISTING BAMBOO FLOOR BELOW TO REMAIN. CLEAN SURFACE. t 3 EXISTING TERRAZZO FLOORING TO REMAIN AND BE PROTECTED DURING DEMOLITION AND CONSTRUCTION. 14 EXISTING PLUMBING FIXTURES TO BE REMOVED. CAP PLUMBING LINES IN —ORDER TO BE RECOMMISSIONED AT LATER DATE. PANTRY SINK LINE MOVED INTO ADJACENT WALL. REFER TO PLUMBING DRAWINGS ON WHICH WATERLINES AND DRAINAGE LINES ARE BEING REPURPOSED FOR NEW CONSTRUCTION. S 15 EXISTING LOW PARTITIONS TO BE REMOVED BY CONTRACTOR. t 6 EXISTING SOFFIT TO REMAIN t 7 EXISTING FLOORING AND WALL BASE TO REMAIN. t LINE OF BAMBOO FLOORING TO REMAIN. COORDINATE EXACT LOCATION WITH FINISH PLAN AND WITH GLASS FRONTS SHOP DRAWINGS. DEMOLITION KEYNOTES (CONTINUED) t REMOVE PARTITION /SOFFIT TO ALIGN WITH EXISTING GWB CEILING IN EXISTING ROOM 102. PATCH AND REPAIR AS REG'D. REFER TO REFLECTED CEILING PLAN FOR ADD'L INFO. 20 EXISTING DOOR TO REMAIN 21 EXISTING CABINETRY, PLUMBING FIXTURES AND COUNTERTOP TO BE REMOVED AND WALLS AND PLUMBING SYSTEMS PREPARED FOR NEW SCHEDULED CABINETRY, FIXTURES AND FINISHES. CONTRACTOR TO COORDINATE WITH CLIENT ON STORAGE AND /OR REMOVAL OF EXISTING APPLIANCES. 22 EXISTING DOOR THRESHOLD TO REMAIN. 23 EXISTING TILED WALL FINISH TO BE REMOVED BACK TO DEMISING PARTITION AND /OR INTERIOR PARTITION. PATCH AND PREPARE SURFACE TO RECEIVE NEW FINISH. 24 EXISTING ROLLING MANUAL SHADES TO REMAIN, 25 EXISTING FINISHED CEILING AND LIGHT FIXTURES TO REMAIN. err CONTRACTOR TO CAREFULLY REMOVE EXISTING LIGHT FIXTURES AND DIFFUSERS. STORE FOR REUSE. REFER TO REFLECTED CEILING PLAN FOR ADD'L INFO. REMOVE EXISTING CEILING GRID. 27 REMOVE ALL LIGHT FIXTURES AND HANGING CEILING SYSTEM IN THIS AREA 2i EXISTING CEILING CANOPY / LIGHT FIXTURE TO REMAIN. 2'J EXISTING GWB SOFFIT TO BE REMOVED. O3o CONTRACTOR TO CAREFULLY REMOVE EXISTING JET NOZZLE WALL DIFFUSERS (SUPPLY & RETURN). CLEAN, REPAIR AS REQ'D & REINSTALL PER MECHANICAL DWGS. 31 LINE OF SOFFIT TO REMAIN. EXISTING HVAC DIFFUSERS TO REMAIN AND REPURPOSED INTO THE UPDATED HVAC SYSTEM. PROTECT DURING DEMOLITION. 32 EXISTING EXIT SIGNS TO REMAIN. REFER TO RCPs FOR ADD'L INFO. 33 EXISTING WATERLINE TO REMAIN. REFER TO PLUMBING DRAWINGS FOR ADD'L INFO. 34 EXISTING WALL MOUNTED AIR — CONDITIONER UNIT AND REMOTE CONTROL TO REMAIN. PROTECT DURING CONSTRUCTION. REPLACE FILTER AND CLEAN AS REQUIRED. 1 a` ..• Osseo *see 0 got • • c y v a a u 0 t p G L r r-i 11'f N m 0 N n li D> 3 °n z rL Z O F- J O W d O O LL 0 O r-I 0 11 N u E C U 0 E 0 lu N u Ft m N CD N N 0 N V u _.. -. i ML / u .o c u a R N N CL C Y • •+ + • • • �• a • a• • architect NORBERTO ROSENSTEIN ARCHITECT INC. , WITECTUPIE - lWffl Pi DESM - PLANNING 126 S. FEDERAL HIGHWAY SUITE # 202 DANIA BEACH, FLORIDA 33004 PH: (954) 922 -6551 FAX: (954) 922 -7388 EMAIL -infoarosensteinarchitect.com WEB: www.rosensteinarchitect.com STATE REG. NO. AR0016674 NATL.. REG. NO. 69178 COPYRIGHT © 2012 NORIERTO ROSENSTEIN ARCHITECT, INC. ALL RIGHTS RESERVED. THIS DOCUMENT OR PARTS THEREOF, MAY NOT BE REPRODUCED IN ANY.FORMWITHOUT PERMISSION. FDESIGNEDERTIFY THAT THESE PLANS PARED BY ME OR UNDER ISION, AND TO THE BEST OF MY KNOWLEDGE, COMPLY WITH ALL APPLICABLE CODES. Q 03.15.13 ADDENDUM #G / CONSTRUCTION A 02.22.13 ADDENDUM #13 02.21.13 ADDENDUM #3.2 Q 02.18.13 ADDENDUM #3 02.22.13 BLDG DPT / ADDENDUM #2 0 r2 01.20.13 PRESUBMITTAL /COORDINATION R E V I S I O N S COMM. DATE 2012-53 01/04/2013 FIR TREE PARTNERS SOUTH MIAMI EXISTING SPACE RENOVATION 7301 SW 57th COURT SOUTH MIAMI, FLORIDA 33143 4TH FLOOR DEMOLITION PLAN D -100 OF 900 a a u 0 t p G L r r-i 11'f N m 0 N n li D> 3 °n z rL Z O F- J O W d O O LL 0 O r-I 0 11 N u E C U 0 E 0 lu N u Ft m N CD N N 0 N V u _.. -. i ML / u .o c u a R N N CL C