13-205-018CONTINUOUS ACOUSTICAL
SEAL JOINT AT
PERIMETER, TYP.
(1) LAYER 5/f
ON 3 -5/8' ME
STUDS @ 16'
BOXED HEADI
B.O. FINISHED
+9' -0" A.F.F.
SCHEDULED F
B.O. FINISHED
+8' -2" A.F.F,
SUSPENDED
CEILING TILE
BOTTOM OF SLAB
STUD KICKER AS
REQUIRED
ACOUSTICAL SOUND
BLANKET FRICTION
FITTED BETWEEN
STUD CAVITY, TYP.--,
B.O. SOFFIT
OL
+9' -0' A.F.F.
(1) LAYER 5/8' GWB
ON 3 -5/8" METAL
STUDS @ 16 O.C. MAX --
WOOD BLOCKING
SIZED AS REQ'D
B.O. TRIMMED OPENNING
+7' -6" A.F.F.
ALIGN
- SUSPENDED ACOUSTICAL
CEILING TILE
SOFFIT DETAIL �AT PA NTRY 411
' = 1' -0
z
BOTTOM OF SLAB
ACOUSTICAL SOUND
BLANKET FRICTION
FITTED BETWEEN
STUD CAVITY, TYP.
STUD KICKER AS
REQUIRED
(1) LAYER 5/8" GWB
SUSPENDED ACOUSTICAL
CEILING TILE
CEILING DETAIL AT CONFERENCE ROOM 509
scale: 1 112' = T -0'
CONF. ARE
OFFICE 4C
BOTTOM OF SLAB A
STUD KICKER AS RD
EXISTING CEILING TILE
GRID. TRIM AS REQ'D
(1) LAYER 5/8" GWB
METAL STUDS @ 16"
EXISTING GWB FINISH
EXISTING PARTITION
ACOUSTICAL SOUND
BLANKET FRICTION
FITTED BETWEEN
STUD CAVITY, TYP.
B.O. TRIMMED OPENING
+9' -0" A.F.F.
(1) LAYER 5/8" GWB
ON 3 -5/8" METAL
STUDS @ 16' O.C. MAX
2x4 TREATED WOOD
BLOCKING MIN.
SCHEDULED PARTITION
BOTTOM OF SLAB
(1) LAYER 5/8" GWB ON
3 -5/8" METAL STUDS @
16' O.C. MAX.
ACOUSTICAL SOUND
BLANKET FRICTION
FITTED BETWEEN STUD
CAVITY, TYP.
SCHEDULED FINISHED
CEILING
PT -1
TV MONITOR AND
SWIVEL SUPPORT
BRACKET
PT -1
9' VIF
�!A L D ETAIL AT OFFICE 500 A le: 1 1/2" = Al,
CEILING DETAIL AT CONF. ROOM 408/409
scale: 1 1/2' = 1' -0'
BOTTOM OF SLAB
STRUCTURAL CABLES AS
PER AP -1 SPECIFICATION.
SPECIFIED COVE LIGF
REFER TO FIXTURE
SCHEDULE FOR ADD
24" X 60' AP -1 TILE.
KNIFE EDGE DETAIL
B.O. SOFFIT
+9' -0" A.F.F.
6 CEILING DETAIL AT PANTRY 502
scale: 1 1/2' = 1'-0'
BOTTOM OF SLAB
STUD KICKER AS
REQUIRED
SUSPENDED ACOUSTICAL
CEILING TILE
B.O. FINISHED CEILING
+9' -0" A.F.F.
(1) LAYER 5/8" GWB
0
T
B.O. FINISHED CEILING '
+8' -2" A.F.F.
24" X 60' AP--1 TILE.
MITRE EDGE DETAIL
z
CEILING DETAIL AT CONFERENCE ROOM 509
scale: 1 1/2' = T -0"
M13
BOTTOM OF SLAB ABOVE
SCHEDULED PARTITION
TYPE 2
(1) LAYER 5/8' GWB ON
3 -5/8" METAL STUDS @ 16"
O.C. MAX. ACOUSTICAL
SOUND BLANKET FRICTION
FITTED BETWEEN STUD
CAVITY, TYP.
B.O. TRIMMED OPENING
+9' -0' A.F.F.
2x4 TREATED WOOD
BLOCKING
SCHEDULED PARTITION
�CEILING DETAIL AT CLOSET 409A
e: 1 112' = T -0'
1 -112' COLD ROLLED 16
GA. STEEL SUSPENSION
CHANNEL W /HAT
CHANNELS @ 12" O.C. MAX
SCHEDULED
PARTITION
B.O. HUNG CEILING
+9' -0" A.F.F.
AP -1 FLUSH JOINTS
2 COVE LIGHT DETAIL AT CONF. ROOM 409 CEILING DETAIL AT LARGE MEDIA ELEMENT 409
scale: 1 1/2" = T -0" M11 scale: 1 112' = 1' -O' Mt
•
• g:
ri +•+ • Y • i
Do.
000
go
i • • • •
r•
N • ,.:
We "rY
13TRC CY U"' €., :{
l
r
i
i
J
iJ
u
o
IL
c
u
E
u
R
L
•••
•+•
i
•
• ••
architect
NORBERTO ROSENSTEIN
ARCHITECT INC.
AROMTURE - INTERIOR DE" - FLMNNG
126 S. FEDERAL HIGHWAY
SUITE # 202
DANIA BEACH, FLORIDA 33004
PH- (954) 922 -6551
FAX= (954) 922 -7388
EMAIL -.info•rosensteinarchhect.com
WEB, www.rosensteinarchitect.com
STATE REG. NO. AR0016674
NATL. REG. NO. 69178
COPYRIGHT CO 2012
NORBERTO ROSENSTEIN ARCHITECT, INC.
ALL RIGHTS RESERVED. THIS DOCUMENT
OR PARTS THEREOF, MAY NOT SE REPRODUCED
IN ANY FORM WITHOUT PERN'iIS901a.�rr
'
rr
, ,, `�'1 .
FDEI,GNED
C'' ,' l
;S` 2
..
,
•..... ,
5� r.�'
I HEREBY CERTIFY THAT THESE PLANS
WHERE PREPARED BY ME OR UNDER
MY SUPERVISION, AND TO THE BEST
OF MY KNOWLEDGE, COMPLY WITH ALL
APPLICABLE CODES.
Q
03.15.13
ADDENDUM #6 / CONSTRUCTION
A
02.22.13
ADDENDUM #3.3
02.21.13
ADDENDUM #3.2
0
02.18.13
ADDENDUM .#3
2
02.22.13
BLDG DPT / ADDENDUM #2
A
01.20.13
PRESUBMITTAL /COORDINATION
R E V I S 1 0 N S
COMM.
DATE
2012 -53
01/04/2013
FIR TREE PARTNERS
SOUTH MIAMI
EXISTING SPACE
RENOVATION
7301 SW 57th COURT
SOUTH MIAMI, FLORIDA 33143
D ETAI LS
A -801 900
i
i
J
iJ
u
o
IL
c
u
E
u
R
L
i
n,
M
i_I
C
II