Loading...
13-205-006L 1- VTrMI0M 1A /II\IrVl1A/ REFLECTED CEILING NOTES: 1, PLAN SHOWN FOR LOCATION OF CEILING SYSTEMS AND DEVICES ONLY, SEE ENGINEER'S PLANS FOR ELECTRICAL CIRCUITING, MECHANICAL, FIRE, AND LIFE SAFETY DEVICES (FINAL QUANTITIES SHOWN ON ENGINEER'S DRAWINGS SHALL SUPERCEDE). 2. ALL ELEVATIONS GIVEN ARE THE HEIGHT ABOVE TOP OF FINISH FLOOR. 3. G.C. SHALL BE RESPONSIBLE FOR REPAIR AND RESTORATION OF ALL FIREPROOFING FOR ALL STRUCTURAL MEMBERS THAT MAY BE DAMAGED BY CONSTRUCTION OPERATIONS. FIREPROOFING TO MATCH EXISTING. VERIFY TYPE WITH BUILDING MANAGEMENT. 4. T TED TO THE SURFACE MOUNTED FIXTURES IN EXISTING CEILING TO BE PAINTED PT -2 U.O.N. 6 5. COORDINATE ADDITIONAL CEILING AND WALL MOUNTED DEVICES WITH POWER AND COMMUNICATIONS PLAN. 6. ALL LIGHTING FIXTURES INDICATED TO REMAIN: RELAMP, CLEAN AND REPAIR AS REQ'D PRIOR TO REWIRING. REFER TO ELECTRICAL DRAWINGS FOR ADD'L INFO. 7. LIGHT FIXTURES CONNECTED TO LUTRON TYPE SWITCH SHALL BE DIMMABLE, LEGEND SUBSCRIPT DENOTES: X - EXISTING FIXTURE TYPE A R - REPURPOSED ® 24 "X24' SUPPLY DIFFUSER z 24 "X24" RETURN DIFFUSER -DENOTES SWITCH X -DENOTES SWITCH TYPE WALL MOUNTED SUPPLY DIFFUSER (5TH FLOOR REPURPOSED JET NOZZLE) WALL MOUNTED RETURN DIFFUSER SWITCH TYPES: D DIMMER SWITCH L LUTRON SWITCH LEGEND (CONTINUED) A FIXTURE TYPE A • • • V RECESSED LED FIXTURE A20 FIXTURE TYPE A2 L UNDERCABINET RECESSED LED AMCHITECTUAE - INTERIOR DE" - M"ANNNG FIXTURE 51 FIXTURE TYPE B1 IV` FAX: (954) 922 -7388 PENDANT MOUNTED B.O. N FIXTURE 6' -0' A.F.F. NATL. REG. NO. 69178 FIXTURE TYPE B2 NORBERTO ROSENSTEIN ARCHITECT, INC. FLUORESCENT B.O. FIXTURE PENDANT MOUNTED B.O. @ 9' -0" AFF FIXTURE 6' -0' A.F.F. C _ FIXTURE TYPE C LIGHTING. B.O. @ 10' -0" AFF. FLUORESCENT COVE LIGHT D 0> FIXTURE TYPE D X - EXISTING FIXTURE TO REMAIN RECESSED LED WALL FIXTURE TYPE Wm - RECESSED WASHER FIXTURE E FIXTURE TYPE E SUBSCRIPT DENOTES: UNDERCABINET R - REPURPOSED. CONTRACTOR FLUORESCENT FIXTURE FFx FIXTURE TYPE Fx X - EXISTING TO REMAIN. EXISTING PENDANT LINEAR FIXTURE TYPE Tri - RECESSED DIRECT /INDIRECT DIMMABLE HIGH HAT. SUBSCRIPT DENOTES: BALLAST TO REMAIN @ T- 10'AFF GX FIXTURE TYPE GGx TO CONFIRM QUANTITY. X - EXISTING TO REMAIN. EXISTING CEILING CANOPY / EXIT SIGN - WALL MOUNTED LIGHTING FIXTURE TO REMAIN s SUBSCRIPT DENOTES: T- 10'AFF O_j FIXTURE TYPE J • • • V WALL MOUNTED FIXTURE architect, B.O. @ 8' -0" A.F.F. L FIXTURE TYPE L AMCHITECTUAE - INTERIOR DE" - M"ANNNG 126 S. FEDERAL HIGHWAY PENDANT MOUNTED B.O. DANIA BEACH, FLORIDA 33004 FIXTURE T -6" A.F.F. OF 5TH FAX: (954) 922 -7388 FLOOR N FIXTURE TYPE N NATL. REG. NO. 69178 PENDANT 4' LONG NORBERTO ROSENSTEIN ARCHITECT, INC. FLUORESCENT B.O. FIXTURE OR PARTS THEREOF, MAY NOT BE REPRODUCED @ 9' -0" AFF R p o FIXTURE TYPE R -TRACK M' rJ •: LIGHTING. B.O. @ 10' -0" AFF. � ; ?.' 1 ca w SUBSCRIPT DENOTES: X - EXISTING FIXTURE TO REMAIN ' FIXTURE TYPE Wm - RECESSED w#01 FLUORESCENT 2'x2' FIXTURE. ; SUBSCRIPT DENOTES: WHERE PREPARED BY ME OR UNDER R - REPURPOSED. CONTRACTOR OF MY KNOWLEDGE, COMPLY WITH ALL TO CONFIRM QUANTITY. X - EXISTING TO REMAIN. T,o FIXTURE TYPE Tri - RECESSED HIGH HAT. SUBSCRIPT DENOTES: R - REPURPOSED. CONTRACTOR TO CONFIRM QUANTITY. X - EXISTING TO REMAIN. pH EXIT SIGN - WALL MOUNTED [� SUBSCRIPT DENOTES: EX- EXISTING TO REMAIN R- EXISTING TO BE RELOCATED LEGEND (CONTINUED) CEILING TYPE 1: ACT -1 = SUSPENDED ACOUSTICAL CEILING TILE SYSTEM CEILING TYPE 2: AP -1 = SUSPENDED DECOUSTICAL CEILING TILE SYSTEM_ 2'x5' PANELS •' ` <' CEILING TYPE 3: ..` SUSPENDED GYPSUM BOARD CEILING: 5/8" GWB ON SUSPENDED CHANNELS WITH " HAT CLIPS CEILING TYPE 4: EXISTING TO REMAIN. CONTRACTOR TO PATCH AND REPAIR ALL SURFACES TO BE REPAINTED. REPLACE ALL ACOUSTICAL TILES WITH ACT -1. REFER TO ELEVATIONS FOR ADD'L INFO. CEILING TYPE 5: SURFACE MOUNTED FABRIC CEILING PANELS. l' -6' x 3-0' TILES + + CEILING TYPE 6: + * + + + NOT USED S PT -1 DENOTES SCHEDULED FINISH DENOTES FINISHED CEILING HEIGHT ABOVE FINISHED FLOOR S' DENOTES RECESSED CEILING MOUNTED SPEAKER DEVICE. SUBSCRIPT 'X" INDICATES EXISTING DEVICE TO REMAIN. DS DENOTES CEILING MOUNTED OCCUPANCY SENSOR DEVICE OS DENOTES WALL MOUNTED OCCUPANCY SENSOR DEVICE DENOTES KEYNOTE A H FLOOR REFLECTED CEILING PLAN 1/4' = 1' -0' REFLECTED CEILING KEYNOTES ONO FINISH CEILING. OPEN TO UNDERSIDE OF SLAB ABOVE. PAINT PT -2 U.O.N. OOPEN TO FLOOR ABOVE. OLINE OF EXISTING SOFFIT FACE. OALIGN NEW GWB CEILING WITH EXISTING CEILING. PATCH AND PREP ENTIRE GWB CEILING FOR SCHEDULED FINSH. O PROVIDE INDEPENDENT COOLING SYSTEM FOR THE TECH. CLOSET. aEXISTING HVAC DUCTS. ONEW HVAC DUCTS. NEW SUPPLY DIFFUSERS TO MATCH EXISTING. REFER TO MECHANICAL DWGS FOR SIZES AND LOCATIONS. ONEW BACK -TO -BACK RETURN GRILLS WITH INTERIOR SOUND AND LIGHT BAFFLES. REFER TO MECHANICAL DWGS FOR SIZES AND LOCATIONS. EXISTING FAN -POWER BOXES. REFER TO MECHANICAL DWGS FOR ADD'L INFO. 1 o EXISTING RETURN DUCT & GRILL. REDUCE DUCT LENGTH. B.O. RETURN GRILL @ 10' -0'AFF f MODIFY EXISTING DUCT & RELOCATE DIFFUSERS. REFER TO MECH, DWGS FOR ADD'L INFO. 12 LINEAR WALL RETURN DIFFUSER. B.O. s 10' -0 "AFF. 13 REPLACE EXISTING FIXTURE TYPE W WITH FIXTURE TYPE TR. 14 ADD FIXTURE TYPE Ell TO EXISTING CEILING. 15 ALTERNATE: ACT -1, ACOUSTICAL CEILING TILE SYSTEM. HEIGHT T.B.D. • r • • r • • • Yi•• • • • • W v • • •r 0 U O Ln L r-I m 0 N M i i i 7 Z 5 L z LuU Lu w.. V J W Q O LLLLn CDJ N 0 N ri >= I C dj s 0 E n t O v t `u C n lu u LL M N i w v!i O IL E p- 0 u t G u n ri N N CL M C N ! • • • V • J • architect, NORBERTO ROSENSTEIN ARCHITECT INC. , AMCHITECTUAE - INTERIOR DE" - M"ANNNG 126 S. FEDERAL HIGHWAY SUITE # 202 DANIA BEACH, FLORIDA 33004 PH: (954) 922 -6551 FAX: (954) 922 -7388 EMAIL :irdoorosensteinarchitect.com WEB: www.rosensteinarchitect.com STATE REG. NO. AR0016674 NATL. REG. NO. 69178 COPYRIGHT © 2012 NORBERTO ROSENSTEIN ARCHITECT, INC. ALL RIGHTS RESERVED. THIS DOCUMENT OR PARTS THEREOF, MAY NOT BE REPRODUCED IN ANY FORM WITHOUT PERMISSION. DESIGNED M' rJ •: N.R. � ; ?.' 1 ca w DRAWN D. P. ' CHECKED N. R. ; I HEREBY CERTIFY THAT THESE PLANS WHERE PREPARED BY ME OR UNDER MY SUPERVISION, AND TO THE BEST OF MY KNOWLEDGE, COMPLY WITH ALL APPLICABLE CODES. Q 03.15.13 ADDENDUM #6 / CONSTRUCTION 02.22.13 ADDENDUM #3.3 02.21.13 ADDENDUM #3.2 Q 02.18.13 ADDENDUM #3 Q 02.22.13 BLDG DPT / ADDENDUM #2 Q 01.20.13 PRESUBMITTAL /COORDINATION R E V I S 1 0 N S COMM. DATE 2012-53 01/04/201,3 FIR TREE PARTNERS SOUTH MIAMI EXISTING SPACE RENOVATION 7301 SW 57th COURT SOUTH MIAMI, FLORIDA 33143 5TH FLOOR REFLECTED CEILING PLAN A-201 900 0 U O Ln L r-I m 0 N M i i i 7 Z 5 L z LuU Lu w.. V J W Q O LLLLn CDJ N 0 N ri >= I C dj s 0 E n t O v t `u C n lu u LL M N i w v!i O IL E p- 0 u t G u n ri N N CL M C N !