Loading...
13-205-013r op 0 CV 0 CV O ZD CV CV 0 N O N 0 N 0 N 0 CV 0 N O N 0 REFLECTED CEILING NOTES: F03 1. PLAN SHOWN FOR LOCATION OF CEILING SYSTEMS AND DEVICES ONLY. SEE ENGINEER'S PLANS FOR ELECTRICAL CIRCUITING, MECHANICAL, FIRE, AND LIFE SAFETY DEVICES (FINAL QUANTITIES SHOWN ON ENGINEER'S DRAWINGS SHALL SUPERCEDE). 2. ALL ELEVATIONS GIVEN ARE THE HEIGHT ABOVE TOP OF FINISH FLOOR. 3. G.C. SHALL BE RESPONSIBLE FOR REPAIR AND RESTORATION OF ALL FIREPROOFING FOR ALL STRUCTURAL MEMBERS THAT MAY BE DAMAGED BY CONSTRUCTION OPERATIONS. FIREPROOFING TO MATCH EXISTING. VERIFY TYPE WITH BUILDING MANAGEMENT. 4, ALL EXPOSED CONDUITS ASSOCIATED TO THE SURFACE MOUNTED FIXTURES IN EXISTING CEILING TO BE PAINTED TO MATCH CEILING PAINT, TYPICAL. 5. COORDINATE ADDITIONAL CEILING AND WALL MOUNTED DEVICES WITH POWER AND COMMUNICATIONS PLAN. 6. ALL LIGHTING FIXTURES INDICATED TO REMAIN: RELAMP, CLEAN AND REPAIR AS REQ'D PRIOR TO REWIRING. REFER TO ELECTRICAL DRAWINGS FOR ADD'L INFO. T LIGHT FIXTURES CONNECTED TO LUTRON SWITCH SHALL BE DIMMERABLE. LEGEND SUBSCRIPT DENOTES: X - EXISTING R- REPURPOSED 24 ")24" SUPPLY DIFFUSER 24" '04" RETURN DIFFUSER DEf�P TES SWITCH (DTES SWITCH TYPE X -= DENi WALL MOUNTED SUPPLY DIFFUSER (5TH FLOOR REPURPOSED JET NOZZLE) WALL MOUNTED RETURN DIFFUSER SWITCH TYPES: D DIMMER SWITCH L LUTRON SWITCH 5-0" 5' -0" F02 LEGEND (CONTINUED) Fx Gx CONF. AREA A® FIXTURE TYPE A RECESSED LED FIXTURE A20 FIXTURE TYPE A2 UNDERCABINET RECESSED LED FIXTURE LJ ME, 1111111421 C D c> E FIXTURE TYPE B1 PENDANT MOUNTED B.O. FIXTURE 6' -0" A.F.F. FIXTURE TYPE B2 PENDANT MOUNTED B.O. FIXTURE 6' -0" A.F.F. FIXTURE TYPE C FLUORESCENT COVE LIGHT FIXTURE TYPE D RECESSED LED WALL WASHER FIXTURE FIXTURE TYPE E UNDERCABINET FLUORESCENT FIXTURE FIXTURE TYPE Fx EXISTING PENDANT LINEAR DIREL;TANDIRECT DIMMABLE BALL-AST TO REMAIN @ T -10 'AFF FIXTI,_ �)RE TYPE�Gx EX'S'} ING CEILING CANOPY / LIGI - 'j-j ING FIXTURE TO REMAIN @ 7'- 10)'AFF J o-i FIXTURE TYPE J WALL MOUNTED FIXTURE B.Q. @ 8' -0" A.F.F. L FIXTURE TYPE L PENDANT MOUNTED B.O. FIXTURE 7' -6" A.F.F. OF 5TH FLOOR N FIXTURE TYPE N PENDANT 4' LONG FLUORESCENT B.O. FIXTURE @ 9' -0" AFF R o o FIXTURE TYPE R -TRACK LIGHTING. B.O. @ 10' -0" AFF. SUBSCRIPT DENOTES: X - EXISTING FIXTURE TO REMAIN FIXTURE TYPE WR - RECESSED WR FLUORESCENT 2'x2' FIXTURE. SUBSCRIPT DENOTES: R - REPURPOSED. CONTRACTOR TO CONFIRM QUANTITY. X - EXISTING TO REMAIN. TRo FIXTURE TYPE TR - RECESSED HIGH HAT. SUBSCRIPT DENOTES: R - REPURPOSED. CONTRACTOR TO CONFIRM QUANTITY. X - EXISTING TO REMAIN. G� EXIT SIGN - WALL MOUNTED d� SUBSCRIPT DENOTES: EX- EXISTING TO REMAIN R- EXISTING TO BE RELOCATED 4TH FLOOR REFLECTED CEILING PLAN scale: 1/4' = 1' -0" LEGEND (CONTINUED) CEILING TYPE 1: ACT -1 = SUSPENDED ACOUSTICAL CEILING TILE SYSTEM CEILING TYPE 2: AP -1 = SUSPENDED DECOUSTICAL CEILING TILE SYSTEM. 2'x5' PANELS CEILING TYPE 3: SUSPENDED GYPSUM BOARD CEILING: 5/8" GWB ON SUSPENDED CHANNELS WITH HAT CLIPS CEILING TYPE 4: EXISTING TO REMAIN. CONTRACTOR TO PATCH AND REPAIR ALL SURFACES TO BE REPAINTED. REPLACE ALL ACOUSTICAL TILES WITH ACT -1. REFER TO ELEVATIONS FOR ADD'L INFO. CEILING TYPE 5: SURFACE MOUNTED FABRIC CEILING PANELS. 1' -6" x 3' -0" TILES + + CEILING TYPE 6: + + + SUSPENDED FABRIC CEILING PANELS. 1' -6" x 3' -0" TILES B.O. TILE AT 9' -0" A.F.F. PT-1 DENOTES SCHEDULED FINISH DENOTES FINISHED CEILING HEIGHT ABOVE FINISHED FLOOR SP DENOTES RECESSED CEILING MOUNTED SPEAKER DEVICE. SUBSCRIPT "X" INDICATES EXISTING DEVICE TO REMAIN. QS DENOTES CEILING MOUNTED OCCUPANCY SENSOR DEVICE US DENOTES WALL MOUNTED OCCUPANCY SENSOR DEVICE DENOTES KEYNOTE KEYNOTES ONO FINISH CEILING. OPEN TO UNDERSIDE OF SLAB ABOVE. PAINT PT -2 U.O.N. OOPEN TO FLOOR ABOVE. OLINE OF EXISTING SOFFIT FACE. OALIGN NEW GWB CEILING WITH EXISTING CEILING, PATCH AND PREP ENTIRE GWB CEILING FOR SCHEDULED FINSH. O5 PROVIDE INDEPENDENT COOLING SYSTEM FOR THE TECH. CLOSET. OEXISTING HVAC DUCTS. / \ NEW HVAC DUCTS. NEW SUPPLY DIFFUSERS TO MATCH EXISTING. REFER TO MECHANICAL DWGS FOR SIZES AND LOCATIONS. NEW BACK -TO -BACK RETURN GRILLS WITH INTERIOR SOUND AND LIGHT BAFFLES, REFER TO MECHANICAL DWGS FOR SIZES AND LOCATIONS. OEXISTING FAN -POWER BOXES. REFER TO MECHANICAL DWGS FOR ADD'L INFO. a EXISTING RETURN DUCT & GRILL. REDUCE DUCT LENGTH. B.O. RETURN GRILL @ 10' -0 "AFF 11 MODIFY EXISTING DUCT & RELOCATE DIFFUSERS. REFER TO MECH. DWGS FOR ADD'L INFO. 12 LINEAR WALL RETURN DIFFUSER. B.O. @ 10' -0 "AFF. 13 REPLACE EXISTING FIXTURE TYPE W WITH FIXTURE TYPE TR. 14 ADD FIXTURE TYPE 131 TO EXISTING CEILING. architect NORBERTO ROSENSTEIN ARCHITECT , INC" ARDin'ECTURE - INTERIOR DESIGN - PLANNNG 126 S. FEDERAL HIGHWAY SUITE # 202 DANIA BEACH, FLORIDA 33004 PH: (954) 922 -6551 FAX- (954) 922 -7388 EMAIL :info-orosensteinarchitect.com WEB: www.rosensteinarchitect.com STATE REG. NO, AR0016674 NATL. REG. NO. 69178 COPYRIGHT © 2012 NORBERTO ROSENSTEIN ARCHITECT, INC. ALL RIGHTS RESERVED. THIS DOCUMENT OR PARTS THEREOF, MAY NOT BE REPRODUCED IN ANY FORM WITHOUT PERMISSION. JNE I HEREBY CERTIFY THAT THESE PLANS WHERE PREPARED BY ME OR UNDER MY SUPERVISION, AND TO THE BEST OF MY KNOWLEDGE, COMPLY WITH ALL APPLICABLE CODES. A 01.20.13 PRESUBMITTAL /COORDINATION R E V I S 1 0 N S COMM. 1 DATE 2012-5 01/04/2013 FIR TREE PARTNERS SOUTH MIAMI EXISTING SPACE RENOVATION 7301 SW 57th COURT SOUTH MIAMI, FLORIDA 33143 4th FLOOR REFLECTED CEILING PLAN A-200 900