Loading...
13-205-001■ FIR TREE PARTNERS -SOUTH MIAMI EXISTING SPACE RENOVAT10"N 7301 SW 57TH CT. SUITE 410 & 510, SOUT1.1 M1AMI, FL 33143 LIST OF DRA WINGS T -100 TITLE SHEET, NOTES AND LEGENDS T -101 GENERAL NOTES T -102 GENERAL NOTES P -100 DEMOLITION AND CONSTRUCTION PHASING PLANS D -100 DEMOLITION PLAN 4TH FLOOR D -101 DEMOLITION PLAN 5TH FLOOR A -000 TYPICAL ADA DETAILS A -010 PARTITION TYPES A -100 CONSTRUCTION PLAN 4TH FLOOR A -101 CONSTRUCTION PLAN 5TH FLOOR A -200 REFLECTED CEILING PLAN 4TH FLOOR A -201 REFLECTED CEILING PLAN 5TH FLOOR A -300 POWER & COMMUNICATIONS PLAN 4TH FLOOR A -301 POWER & COMMUNICATIONS PLAN 5TH FLOOR A -400 FINISH PLAN 4TH FLOOR A -401 FINISH PLAN 5TH FLOOR A -500 FURNITURE PLAN 4TH FLOOR A -501 FURNITURE PLAN 5TH FLOOR A -600 ELEVATIONS A -601 ELEVATIONS A -650 STAIR DETAILS A -700 DOOR SCHEDULE A -701 SCHEDULES A -850 PANTRY DETAILS A -900 FIRESTOPPING DETAILS DM- 100.00 4TH FLOOR DEMOLITION PLAN DM- 101.00 5TH FLOOR DEMOLITION PLAN M- 200.00 4TH FLOOR HVAC PLAN M- 201.00 5TH FLOOR HVAC PLAN M- 300.00 HVAC NOTES, DETAILS, SCHEDULES FP- 200.00 4TH FLOOR FIRE PROTECTION PLAN FP- 201.00 5HT FLOOR FIRE PROTECTION PLAN DE- 100.00 4TH FLOOR DEMOLITION PLAN DE- 101.00 51H FLOOR DEMOLITION PLAN E- 100.00 4TH FLOOR ELECTRICAL PLAN POWER E- 101.00 5TH FLOOR ELECTRICAL PLAN POWER E- 200.00 4TH FLOOR ELECTRICAL PLAN LIGHTING E- 201.00 5TH FLOOR ELECTRICAL PLAN LIGHTING E- 300.00 PANELS, RISER DP- 101.00 5TH FLOOR DEMOLITION PLAN P- 100.00 4TH FLOOR PLUMBING PLAN P-101.00 5TH FLOOR PLUMBING PLAN S1.01 GENERAL STRUCTURAL NOTES S2.01 FIFTH FLOOR FRAMING PLAN S2.02 PARTIAL FIFTH FLOOR FRAMING PLAN S3.01 SECTIONS PROJECT LOCATION PLAN I SYMBOL NOTES DETAIL REFERENCE 4a �j c :r t f z: 4111 CE G S I WALL TYPE REFERENCE -. SECTION REFERENCE m FIFTH FLOOR INTERIOR MODIFIC'A TIONS ONLY LWNA ELEVATION REFERENCE l^^^1 ROOM NUMBER XX DOOR NUMBER A ELEVATION a.a,.,�...�.,R. . F._ ON A BOARD APPEARANCE) IDENTIFYING DEVICES APPEARANCE) REQUIlift AREA OF WORK EXISTING RESTROOMS (4TH FLOOR) (4TH FLOOR) M. I.._ _t> I I I I I A" x I I I I E 6 0 j„ : „F Im "o FOURTH FLOOR 1.) PROVIDE MAXIMUM CAPACITY SIGN, RAISED OCCUPANT CHARACTERS, BORDER, AND BRAILLE CHARACTERS. 2.) MAXIMUM CAPACITY SIGN SHALL READ: "44 OCCUPANTS MAXIMUM CAPACITY" 3.) MAXIMUM CAPACITY SIGN SHALL BE LOCATED IN A CONSPICUQ'US LOCATION. 4.) PROVIDE REQUIRED ACCE�'SIBILITY SIGNAGE AT RESTROOMS. 1 I m CODE RE VIE W PROJECT EXISTING SPACE RENOVATION DESCRIPTION: FOR CURRENT TENANT AUTHORITY: CITY OF SOUTH MIAMI BUILDING DEPARTMENT PH. 305 663 6355 BUILDING CODE: 2010 FLORIDA BLDG. CODE AMENDMENTS: STATE AND LOCAL PLUMBING CODE: 2010 FLORIDA PLUMBING CODE MECHANICAL CODE: 2010 FLORIDA MECHANICAL CODE GAS CODE: 2010 FLORIDA FUEL GAS CODE ELECTRICAL CODE: 2010 NATIONAL ELECTRIC CODE FLORIDA FIRE PREVENTION CODE. 2010 CODE CONSTRUCTION TYPE: TYPE: I USE: BUSINESS BUILDING IS FULLY SPRINKLERED NUMBER OF STORIES FOR BUILDOUT: TWO (EXISTING) ALTERATION LEVEL = 2 TOTAL AREA OF CONSTRUCTION: 5,294 S.F. 4TH FLOOR TOTAL 3000 SQ. FT. BUSINESS: 2133 / 100 = 22 UNOCCUPIED: 867 / 0 = 0 TOTAL = 22 5TH FLOOR TOTAL 2294 SQ. FT. BUSINESS: 1924 / 100 = 20 UNOCCUPIED: 370 / 0_ = 0 TOTAL = 20 MAX TOTAL OCCUPANCY 44 FULL TIME EMPLOYEES 8. COMPLY WITH APPLICABLE CODES AND /OR ORDINANCES CONCERNING REQUIRED NUMBER OF EXITS: 0.2" X 44 = 8.6 12 "/8.6" = 1.39 L. F. REQ'D. NUMBER OF EXITS PROVIDED: 2 EXITS @ 3' -O" = 6' -0" L.F. SANITARY FACILITIES AS PER TABLE 403.1 FBCP: RESTROOM FACILITIES PROVIDED IN HALLWAY GENERAL NO TES FIRS G E DIVISIOI',I 1 GENERAL REQUIREMENTS 1. TH :: INTENT OF THESE DOCUMENTS IS TO PROVIDE FOR THE 7. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE DISCOVERY, COI`�I:aTRUCTION OF THIS PROJECT, COMPLETE AND FUNCTIONAL PRESENCE, HANDLING, REMOVAL OR DISPOSAL OF OR EXPOSURE OF IN ALL RESPECTS. THE CONTRACTOR SHALL BE RESPONSIBLE PERSONS TO HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT SITE, FOR THIS RESULT. THE OMISSION OF EXPRESS REFERENCE TO INCLUDING BUT NOT LIMITED TO ASBESTOS, ASBESTOS PRODUCTS, WORK NECESSARY AND REASONABLY INCIDENTAL FOR THE POLYCHLORINATED BIPHENYL (PCB) OR OTHER SUBSTANCES. COMIPLETE CONSTRUCTION OF THE PROJECT SHALL NOT BE 8. COMPLY WITH APPLICABLE CODES AND /OR ORDINANCES CONCERNING CONSTRUED AS RELEASING THE CONTRACTOR FROM HIS DEMOLITION OPERATIONS, REFUSE REMOVAL, AND DISPOSAL. RESPONSIBILITIES. DIVISION 3 CONCRETE 2. THE CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, CLEARANCES AND CONDITIONS AND INFORM THE ARCHITECT 1. CLEAN, GRIND AND FILL EXISTING CONCRETE TO ACCEPT VINYL OF ANY DISCREPANCIES PRIOR TO TILE, CARPET, OR CERAMIC TILE. BIDDING THE WORK. FAILURE TO DO SO CONSTITUTES 2. FLOORS TO RECEIVE TILE OR SHEET VINYL SHALL NOT VARY ACCEPTANCE AND RESPONSIBILITY FOR ALL EXISTING CONDITIONS. MORE THAN 1/4" PER 10 FEET. 3. THE CONTRACTOR WILL NOT BE ALLOWED ADJUSTMENTS IN THE TIME DIVISION 5 METALS OR MONEY REQUIRED TO RECTIFY THE SITUATION. 1. STEEL FRAMING: WITH EACH TYPE OF METAL FRAMING REQUIRED, 4. DO NOT SCALE DRAWINGS. GIVEN DIMENSIONS SHALL GOVERN. PROVIDE MANUFACTURER'S STANDARD STEEL RUNNER, BLOCKING, LARGE SCALE DRAWINGS SHALL GOVERN OVER SMALL SCALE LINTELS, CLIP ANGELS, SHOES, REINFORCEMENTS, FASTENERS AND DRAWINGS, ACCESSORIES AS RECOMMENDED BY THE MANUFACTURER FOR THE APPLICATIONS INDICATED. 5. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF ALL 2. METAL STUDS: OPEN BOX SHAPED SECTIONS, 3-1/2 INCH x 25 GAGE PURCHASED, FABRICATED AND FINISHED ITEMS FOR REVIEW BY MIN. (20 GAGE FOR STUDS OVER 14' -0" IN HEIGHT AND AT WALL AT THE ARCHITECT UNLESS WAIVED BY THE SAME. WATER HEATER /MOP SINK ENCLOSURE). 6. ALL EQUIPMENT, MATERIALS AND ARTICLES INCORPORATED DIVISION 8 DOORS & WINDOWS INTO THE PROJECT SHALL BE NEW AND UNDAMAGED. ALL WORKMANSHIP SHALL BE WITHIN INDUSTRY STANDARDS. 1. ALL GLASS SUBJECT TO HUMAN IMPACT SHALL CONFORM TO THE STANDARDS SET FORTH IN THE UNIFORM BUILDING CODE. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR AND REPLACEMENT OF DAMAGE TO AREAS CAUSED BY HIS WORK AT 2• ALL EXITS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE NO ADDITIONAL COST TO THE OWNER. USE OF A KEY OR SPECIAL KNOWLEDGE. 8. THE" CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY 3. MANUALLY OPERATED EDGE OR SURFACE - MOUNTED FLUSH BOLTS COirIDITIONS RELATING TO JOB CONSTRUCTION INCLUDING A SAFE AND SURFACE BOLTS OR ANY OTHER TYPE 'OF DEVICE THAT MAY BE ENVIRONMENT FOR OCCUPANTS OF AREAS ADJACENT TO THE USED TO CLOSE OR RESTRAIN THE DOOR ARE PROHIBITED. WHERE WOs•_K AREA. EXIT DOORS ARE USED IN PAIRS AND APPROVED AUTOMATIC FLUSH BOLTS ARE USED, THE DOOR LEAF HAVING THE AUTOMATIC FLUSH 9. THE: CONTRACTOR SHALL PAY ALL FEES FOR PERMITS BOLTS SHALL HAVE NO DOORKNOB OR SURFACE- MOUNTED HARDWARE. NECESSARY FOR PROPER COMPLETION OF WORK, UNLESS THE UNLATCHING OF ANY LEAF SHALL NOT REQUIRE MORE THAN ONE NOIED OTHERWISE. OPERATION. 10. SH0''JLD THE CONTRACTOR OBSERVE ERRORS, DISCREPANCIES 4. PANIC HARDWARE, WHERE INSTALLED, SHALL COMPLY WITH THE UNIFORM OR OMISSIONS IN THE CONTRACT DOCUMENTS, HE SHALL PROMPTLY BUILDING CODE. THE ACTIVATING MEMBER SHALL BE MOUNTED AT 36 NOTIFY THE ARCHITECT REQUESTING CLARIFICATION. THE TO 44 INCHES ABOVE THE FLOOR. THE UNLATCHING FORCE SHALL NOT CONTRACTOR SHALL NOT PROCEED WITH WORK AFFECTED BY EXCEED 15 POUNDS WHEN APPLIED IN THE DIRECTION OF TRAVEL. SUCH ERRORS, DISCREPANCIES OR OMISSIONS WITHOUT RECEIVING CLARIFICATIONS. ADJUSTMENTS INVOLVING SUCH CONDITIONS MADE DIVISION 9 FINISHES BY THE CONTRACTOR WITHOUT PRIOR CLARIFICATION BY THE 1. INTERIOR FINISHES TO HAVE A MAXIMUM FLAME SPREAD RATING OF 200 ARCHITECT, SHALL BE AT THE CONTRACTOR'S OWN RISK. AND MAXIMUM SMOKE DEVELOPMENT RATING OF 450. COkliPLI CATIONS ARISING FROM PROCEEDING WITHOUT CLARIFICATION 2. STUD PARTITIONS TO BE ANCHORED SO AS TO RESIST A LATERAL SHALL BE RESOLVED AT THE CONTRACTOR'S EXPENSE. LOAD OF 5 PSF AS FOLLOWS, BOTTOM PLATE: ANCHOR TO SUB 11. ALL, WORK PERFORMED ON THIS PROJECT SHALL COMPLY WITH FLOOR WITH 300# POWER DRIVEN PINS AT 48" O.C. ICBO #1639 ALL APPLICABLE LOCAL, STATE AND NATIONAL CODES, LAWS 3. GYP BOARD WALLS TO BE TAPED, SANDED AND HAVE LIGHT AND ORDINANCES. ORANGE PEEL FINISH, UNLESS NOTED OTHERWISE. 12. ANYTHING IN THE CONTRACT DOCUMENTS NOT WITHSTANDING, THE 4. THE CONTRACTOR SHALL PROVIDE AND INSTALL CAULKING WHERE CONTRACTOR ACCEPTS THE RESPONSIBILITY OF CONSTRUCTING A NOT SPECIFICALLY PERFORMED BY OTHER TRADES. WATERTIGHT, WEATHER TIGHT PROJECT, 5. CERAMIC TILE FLOORS SHALL NOT VARY MORE THAN 1/4" PER 10 FEET. 13. CONTRACTOR SHALL COORDINATE LOCATION OF ALL NEW ROOF MOUNTED EQUIPMENT WITH OWNER PRIOR TO INSTALL. CENTER EQUIPMENT DIVISION 10 SPECIALTIES OVER BEAM OR COLUMN UNLESS DIRECTED OTHERWISE BY OWNER. 1. SUITE NUMBER OR ADDRESS TO BE POSTED ABOVE DOOR. 14, CONTRACTOR SHALL PROVIDE 2x BLOCKING AT ALL WALL MOUNTED EQUIPMENT OR ACCESSORIES. 2, CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND INSTALLATION / MODIFICATION TO THE FIRE SPRINKLER SYSTEM. 15. ALL SIGNS, INCLUDING WINDOW SIGNS, TO BE SUBMITTED FOR REVIEW AND CONTRACTOR SHALL SUBMIT DRAWING TO GOVERNING AUTHORITY APPROVAL UNDER SEPARATE PERMIT BY OWNER /CONTRACTOR. FOR REVIEW AND APPROVAL PRIOR TO COMMENCING WITH WORK. ALL ANGLES AT 45" OR 90"' UNO. DIVISION 12 FURNISHINGS 1. ALL MILLWORK TO BE CUSTOM GRADE AS CHOSEN BY OWNER. DIVISION 2 DEMOLITION; HAZARDOUS MATERIALS PROVIDE CASEWORK WITH ALL NECESSARY HARDWARE, HINGES 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION AND PULLS. REQUIRED TO ALLOW FOR ALL PROPOSED NEW WORK. DIVISION 15 MECHANICAL 2. PATCH, REPAIR, REPLACE AND FINISH ANY FLOOR, WALL OR CEILING TO MATCH ADJACENT AREAS WHERE DEMOLITION 1. VERIFY FRESH AIR SETTING, HUMIDITY CONTROLS, BALANCE, ETC. HAS BEEN REQUIRED. ARE ADEQUATE FOR PROPOSED USE. REPLACE AND /OR MODIFY SYSTEM AS REQUIRED FOR COMPLIANCE WITH LOCAL GOVERNMENTAL 3• PROVIDE PROPER SHORING AND DISCONNECTION OF ALL UTILITIES I. AGENCIES REQUIREMENTS. Ca` -Y F SOLI 11 killAW PRIOR TO DEMOLITION, 4• THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING THE SITE FREE OF DEBRIS. ^-kwti �A Ld A... N �..�S jl•1..1.. r�7 i.. C+ 9 ,1�y n, 5• THE CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER PRIOR TO :TART OF WORK, THE REQUIREMENTS FOR CORING OF FLOOR r SLA3 FOR ALL REQUIRED WORK. 6. THI. ARCHITECT AND ENGINEERS, AND CONSULTANTS SHALL HAVE NO -- RESPONSIBILITY FOR THE DISCOVERY, PRESENCE, HANDLING, REIIJ!OVAL OR DISPOSAL OF OR EXPOSURE OF PERSONS TO HAZARDOUS MAlERIALS IN ANY FORM AT THE PROJECT SITE, INCLUDING BUT NOT LIMITED TO ASBESTOS PRODUCTS, POLYCHLORINATED BIPHENYL (PC3) OR OTHER TOXIC SUBSTANCES. OWNER'S REVIEW OF THESE CONSTRUCTION DOCUMENTS THE CONSTRUCTION CONTRACT FOR THIS PROJECT IS TO BE NEGOTIATED DIRECTLY BETWEEN THE ,OWNER AND THE CONTRACTOR, AND THEY WILL ACT IN UNISON TO PROPERLY EXECUTE THE INTENT OF THESE AND OTHER DESIGN AND CONTRACT DOCUMENTS. THIS SET OF DOCUMENTS (SHEETS T -100 THROUGH A -900) COVERS GENERAL CONSTRUCTION ITEMS AND EXCLUDES ANY DESIGN OF SITE, OR FIRE PROTECTION WORK. ALSO EXCLUDED ARE ANY EQUIPMENT ITEMS. ALL THESE EXCLUSIONS ARE COVERED UNDER SEPARATE DESIGN WORK BY DESIGNERS WORKING DIRECTLY FOR THE CONTRACTOR AND /OR THE OWNERS CLIENT. BY USE OF THESE DOCUMENTS THE OWNER AND THE CONTRACTOR CERTIFY THAT THEY HAVE REVIEWED THEM AND ARE IN AGREEMENT WITH THEIR CONTENT; ALSO THAT IF ANY CHANGES ARE REQUIRED THEY WILL BE DONE IN ACCORDANCE WITH ALL APPLICABLE CODES AND UNDER THE CONTRACTOR'S OR OWNER'S SUPERVISION. THE CONTRACTOR ASSUMES RESPONSIBILITY FOR COORDINATING THE VARIOUS OTHER CONSTRUCTION DOCUMENTS WITH THESE DESIGN DOCUMENTS TO ASSURE CODE COMPLIANCE AND CORRECTNESS OF WORK. THE CONTRACTOR AND OR OWNERS ASSIGNED AGENT IS ALSO RESPONSIBLE FOR OBTAINING FINAL COMMENTS AND APPROVAL FROM ALL GOVERNING AGENCIES. ANY AS BUILTS OR CHANGES TO THE DOCUMENTS AFTER THE JOB IS PERMITTED ARE ON THE C.O.D BASIS AND IS TO BE PAID IN FI,.11- TO THE APPROPRIATE PARTY. "APPROPRIATE PARTY" PER APPROVED CHANGE ORDER[S] BY CLIENT. ■ architect NORBERTO ROSENSTEIN ARCHITECT , INC. ARCHITECTURE - INTERIOR DESIGN - PLANNING 126 S. FEDERAL HIGHWAY SUITE # 202 DANIA BEACH, FLORIDA 33004 F'H= (954) 922 -6551 FAX= (954) 922 -7388 EMAIL- infoorosensteinarchitect.com WEB: www.rosensteinarchitect.com STATE REG. NO. AR0016674 NATL. REG. NO. 69178 COPYRIGHT (g) 2012 NORBERTO ROSENSTEIN ARCHITECT, INC. ALL RIGHTS RESERVED. THIS DOCUMENT OR PARTS THEREOF, MAY NOT BE REPRODUCED IN ANY FORM WITHOUT PERMISSION. DESIGNED �� N. R. 93� ERR, a V DRAWN (I h P D. P. z CHECKED N.R.B Jt o)9 riot, I HEREBY CERTIFY THAT "THESE PLANS WHERE PREPARED BY ME OR UNDER MY SUPERVISION, AND TO THE BEST OF MY KNOWLEDGE, COMPLY WITH ALL APPLICABLE CODES. 0 1. 2 0.131 PRESUBMITTAL /COORDINATION R E V I S 1 0 N S COMM. DATE 2012-53 01/04/2013 FR TREE PARTNERS SOUTH MIAMI EX STI G SPACE RENOVATION 7301 SW 57th COURT SOUTH MIAMI, FLORIDA 33143 TITLE SHEET