Loading...
12-405-009REQUIRED CAPACITIES AT FIXTURE SUPPLY PIPE OUTLETS FIXTURE SUPPLY OUTLET FLOW RATE FLOW RATE FLOW PRESSURE SERVING (GPM) (PSI) BATHTUB 4 8 BIDET 2 4 COMBINATION FIXTURES 4 8 DISHWASHER (HIGH TEMP) 1.0 8 DISHWASHER (LOW TEMP) 3/8 HOSE BIBBS DRINKING FOUNTAIN 0.75 8 LAUNDRYTRAY 4 8 LAVATORY 3/8 SHOWER, SINGLE HEAD SHOWER 1/2 SINKS, FLUSHING RIM SHOWER, TEMPERATURE CONTROLLED 3 20 SILLCOCK, HOSE BIBB 5 8 SINK, RESIDENTIAL 3/4 WALL HYDRANT SINK, SERVICE 3 8 URINAL, VALVE 15 15 WATER CLOSET, BLOW OUT 35 25 WATER CLOSET, FLUSHOMETER TANK 1.28 15 WATER CLOSET, SIPHONIC 25 15 WATER CLOSET, TANK, CLOSE COUPLED 3 8 WATER CLOSET, TANK, ONE PIECE 6 20 NOTE: NOT ALL FIXURES ARE USED FIXTURE WATER SUPPLY PIPES FIXTURE SYMBOL MINIMUM PIPE SIZE 07'• (INCH) BATHTUBS (60- X 32- AND SMALLER) -------------- 1/2 BATHTUBS (LARGER THAN 60- X 32-) W ct) E 1/2 COMBINATION SINK AND TRAY U) 1/2 DISHWASHER, DOMESTIC 0124.024 OR 1/2 DRINKING FOUNTAIN 0124.131 3/8 HOSE BIBBS SD- 1/2 KITCHEN SINK* (.) CL � 2 1/2 LAVATORY to x 3/8 SHOWER, SINGLE HEAD 1/2 SINKS, FLUSHING RIM U) 0 3/4 SINKS, SERVICE co IF- 1/2 URINAL, FLUSH VALVE co R-0 3/4 WALL HYDRANT FCO--&- 1/2 WATER CLOSET, FLUSH TANK 3/8 WATER CLOSET, FLUSH VALVE 1 F-WATER CLOSET, FLUSHOMETER TANK _______0 PLUMBING FIXTURE SCHEDULE MANUFACTURER 1: [i GENERAL NOTES • I mom PLUMBING LEGEND SYMBOL 07'• ................. AMERICAN STANDAR D -------------- LAVATORY FAUCET HERITAGE TWO HANDLE OR W ct) E INNSB•OOK LAV FCT U) 2 AMERICAN STANDARD 0124.024 OR W COMRADE 0124.131 1: [i GENERAL NOTES • I mom 1 NOTE: ALL SYMBOLS INDICATED MAY NOT BE USED ON DRAWINGS PLUMBING SPECIFICATION 1. GENERAL: MATERIAL SHALL BE NEW, UNUSED, BEST OF THEIR RESPECTIVE KINDS AND FREE FROM DEFECTS IN WORKMANSHIP; IN CONFORMANCE WITH THE LATEST PUBLICATIONS IN FORCE AT TIME OF BIDDING. 2. PIPE MATERIAL: A. SANITARY SOIL AND VENT PIPING: (ABOVE GROUND) PVC TYPE DWV AS PER ASTM D 2665, ASTM D 2949, ASTM F 891, CAST IRON AS PER ASTM Z74, ASTM A 888, CISPI 301. ABS PLASTIC PIPE AS PER ASTM D 2661, ASTM F 628, CSA B 181.1. B. SANITARY SOIL AND VENT PIPING: (BELOW GROUND) PVC TYPE DWV AS PER ASTM D 2665, ASTM D 2949, ASTM D 3034. CAST IRON AS PER ASTM A 74, ASTM A 888, CISPI 301, ABS PLASTIC PIPE AS PER ASTM D 2661, ASTM F 628, ASTM D 2751 C. DOMESTIC WATER SUPPLY PIPING: POLYVINYL CHLORIDE (PVC) PLASTIC PIPE AS PER ASTM D 1785; ASTM D 2241; ASTM D 2672; CSA B137.3 D. WATER DISTRIBUTION PIPE: POLYBUTYLENE (PB PLASTIC PIPE AND TUBING: ASTM D 3309; CSA B137.8M 3, JOINTS AND METHODS OF CONNECTION SHALL COMPLY WITH FBC SECTION P605 4. PIPE FITTINGS: SHALL BE APPROVED FOR INSTALLATION WITH THE PIPING MATERIAL INSTALLED AND SHALL CONFORM TO THE RESPECTIVE PIPE STANDARDS OR ONE OF THE STANDARDS LISTED IN TABLE P605.6. ALL PIPE FITTINGS UTILIZED IN WATER SUPPLY SYSTEMS SHALL ALSO CONFORM TO NSF 61. THE FITTINGS SHALL NOT HAVE LEDGES, SHOULDERS OR REDUCTIONS CAPABLE OF RETARDING OR OBSTRUCTING FLOW IN THE PIPING. 5. PIPE INSULATION: A. ALL CONDENSATE LINES SHALL BE INSULATED WITH 3/4' FIRE RETARDANT ARMAFLEX INSULATION WITH A MAXIMUM OF 25/50 FLAME SPREAD AND SMOKE DEVELOPED RESPECTIVELY. B. ALL HOT WATER AND TEMPERED WATER LINES SHALL BE INSULATED WITH 1" FIRE RETARDANT ARMAFLEX INSULATION WITH A MAXIMUM OF 25150 FLAME SPREAD AND SMOKE DEVELOPED RESPECTIVELY. 6. WATER HAMMER: THE FLOW VELOCITY OF THE WATER DISTRIBUTION SYSTEM SHALL BE CONTROLLED TO REDUCE THE POSSIBILITY OF WATER HAMMER. A WATER-HAMMER ARRESTOR SHALL BE INSTALLED WHERE QUICK-CLOSING VALVES ARE UTILIZED. WATER-HAMMER ARRESTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS SPECIFICATIONS. WATER-HAMMER ARRESTORS SHALL CONFORM TO ASSE 1010. 7. ALL VALVES SHALL BE OF THE APPROVED TYPE AND COMPATIBLE WITH THE TYPE OF PIPING MATERIAL INSTALLED IN THE SYSTEM. 8, LOCATION OF FULL-OPEN VALVES. FULL-OPEN VALVES SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: 1. ON THE BUILDING WATER SERVICE PIPE FROM THE PUBLIC WATER SUPPLY NEAR THE CURB. 2. ON THE WATER DISTRIBUTION SUPPLY PIPE AT THE ENTRANCE INTO THE STRUCTURE. 3. ON THE BASE OF EVERY WATER RISER PIPE. 4. ON THE WATER SUPPLY PIPE TO EVERY WATER HEATER. 5. SHUTOFF VALVES SHALL BE INSTALLED IN ON THE WATER SUPPLY PIPE TO EACH APPLIANCE OR MECHANICAL EQUIPMENT. 9. VALVE IDENTIFICATION. SERVICE AND HOSE BIBB VALVES SHALL BE IDENTIFIED. ALL OTHER VALVES INSTALLED IN LOCATIONS THAT ARE NOT ADJACENT TO THE FIXTURE OR APPLIANCE SHALL BE IDENTIFIED, INDICATING THE FIXTURE OR APPLIANCE SERVED. 10. JOINTS BETWEEN DIFFERENT MATERIALS. JOINTS BETWEEN DIFFERENT PIPING MATERIALS SHALL BE MADE WITH A MECHANICAL JOINT OF THE COMPRESSION OR MECHANICAL-SEALING TYPE, OR AS PERMITTED IN §P605.22.1 AND §P605.22.2. CONNECTORS OR ADAPTERS SHALL HAVE AN ELASTOMERIC SEAL CONFORMING TO ASTM D 1869 OR ASTM F 477, JOINTS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS. 11. ESCUTCHEONS: CHROME PLATED OR STAINLESS STEEL WITH SET SCREWS FOR HOLDING SECURELY IN PLACE. USE ESCUTCHEONS ON PIPES PASSING THROUGH WALLS, FLOORS AND CEILINGS OF FINISHED AREAS. 12. THE HOT WATER SUPPLY TO ANY FIXTURE REQUIRING HOT WATER SHALL BE INSTALLED ON THE LEFT SIDE OF THE FIXTURE. 13. HOSE CONNECTIONS. SILLCOCKS, HOSE BIBBS, WALL HYDRANTS AND OTHER OPENINGS WITH A HOSE CONNECTION SHALL BE PROTECTED BY AN ATMOSPHERIC-TYPE OR PRESSURE-TYPE VACUUM BREAKER OR PERMANENTLY ATTACHED HOSE CONNECTION VACUUM BREAKER, DEMOLITION NOTES 1. DEMOLITION • EXISTING PLUMBING WORK SHALL BE PERFORMED AND COMPLETED UNDER THIS SECTION OF THE WORK. 2. DISCONNECT SOIL, WASTE, VENT HOT AND COLD WATER CONNECTIONS FROM EXISTING FIXTURES. 3. REMOVE ALL EXISTING PLUMBING EQUIPMENT, FIXTURES, PIPING NOT REQUIRED, INCLUDING DRAINAGE, WATER, GAS, RAIN WATER LEADERS, AND SATISFY CODE REQUIREMENTS FOR PROHIBITED DEAD ENDS. 4. CAP EXISTING HOT COLD WATER, WASTE, VENT AND SOIL PIPING AT POINT THAT DOES NOT INTERFERE WITH NEW CONSTRUCTION, I.E. BELOW FINISHED FLOOR, BEHIND FINISHED WALLS OR ABOVE HUNG CEILINGS. 5. THE WORK SHALL INCLUDE THE FURNISHING OF ALL MATERIALS, CUT- I TINGS, EXTENSIONS, CONNECTIONS, REPAIRING, ADAPTING AND OTHER WORK INCIDENTAL THERETO, TOGETHER WITH SUCH TEMPORARY CONNECTIONS AS MAY BE REQUIRED. 6. EXISTING FIXTURES, MATERIALS AND EQUIPMENT TO BE REMOVED SHALL BE SALVAGED OR DISPOSED OF AS DIRECTED BY THE OWNER. 7. ANY WORK NOT SHOWN ON THE DRAWINGS OR SPECIFICALLY MENTIONED IN THE SPECIFICATIONS BUT CONSIDERED NECESSARY FOR THE COMPLETION • THE WORK IN PROPER MANNER SHALL BE PROVIDED BY THIS CONTRACTOR WITHOUT ADDITIONAL CHARGE. 8. CONTRACTOR SHALL DO HIS OWN CUTTING AND REMOVAL OF ALL HIS RELATED WORK IN ALL LOCATIONS WHERE REQUIRED, EXCEPT WHERE OTHERWISE SHOWN • THE DRAWINGS AND/011 AS SPECIFIED. • THIS CONTRACTOR SHALL BE RESPONSIBLE FOR ROUGH PATCHING AND REPAIRING. FINISH PATCHING SHALL BE PERFORMED BY GENERAL CONTRACTOR. System No. W-J-2091 SS i G F Rating - 4 Hr FIREST•P SYSTEMS T Rating L Ste'G A /T N 4 A SECTION A-A 1. WALL ASSEMBLY - MIN 8-1/2 IN. THICK REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF) CONCRETE. WALL MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE BLOCKS*. MAX DIAM • OPENING IS 7-3/8 IN. SEE CONCRETE BLOCKS (CAZT) IN VOLUME 1 OF THE FIRE RESISTANCE DIRECTORY FOR NAMES OF MANUFACTURERS. 2. THROUGH PENETRANTS - ONE NONMETALLIC PIPE TO BE INSTALLED CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN THE PIP AND THE PERIPHERY • THE OPENING SHALL BE A MIN 0 IN. (•• INT CONTACT) TO MAX 314 IN. FOR NOM DIAMETER PIPES AND MIN 0 IN. (POINT CONTACT) TO MAX 112 IN. FOR NOM DIAM (OR SMALLER) PIPES. PIPE TO BE RIGIDLY SUPPORTED • BOTH SIDES • WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES • NONMETALLIC PIPES MAY BE USED. A. POLYVINYL CHLORIDE (PVC) PIPE - NOM 6 IN. DIAM (OR SMALLER) SCHEDULE 40 SOLID OR CELLULAR PVC CORE PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING SYSTEMS. B. CHLORINATED POLYVINYL CHLORIDE (PVC) PIPE - NOM 6 IN. DIAM (OR SMALLER) SDR13.5 CPVC PIPE FOR USE IN CLOSED (PR• CESS OR SUPPLY) PIPING SYSTEMS. THE T RATING IS DEPENDENT UPON THE DIAM OF PIPE USED IN THE FIRESTOP SYSTEM. FOR NOM 4 IN. DIAM (OR SMALLER) PIPES, THE T RATING IS 4 HR FOR PIPES GREATER THAN NOM 4 IN. DIAM. THE T RATING IS 2 HR. 3. FIRESTO• SYSTEM - THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: A. FILL, VOID OR CAVITY MATERIAL - SEALANT* - MIN I-W IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS, FLUSH WITH SURFACE • WALL- HIL11 CONSTRUCTION CHEMICALS, DIV OF HILT] FS-ONE SEALANT B. FIRESTO• DEVICE - FIRESTOP COLLAR - THE FIRESTOP COLLAR SHALL BE INSTALLED IN ACCORDANCE WITH THE ACCOMPANYING INSTALIA71ON INSTRUCTIONS. THE COLLAR SHALL BE T INSTALLED AND LATCHED AROUND THE PIPE AND SECURED TO THE CONCRETE WALL WITH THE ANCHOR HOOKS PROVIDED WITH THE COLLAR- (MIN 2 ANCHOR HOOKS FOR 1-1/2 AND 2 IN. DIAM PIPES, 3 ANCHOR HOOKS FOR 3 AND 4 IN. DIAM PIPES AND 4 ANCHOR HOOKS FOR 6 IN. DAM PIPES). THE ANCHOR HOOKS ARE TO BE SECURED TO THE WALL WITH 114 IN. BY 1-1/2 IN. LONG STEEL EXPANSION BOLTS, IN CONJUCTION WITH STEEL NUTS AND MIN 3/4 IN. DIAM STEEL WASHERS WITH ONE ANCHOR BOLT IN EACH ANCHOR HOOK. SYSTEM NO. W-J-1088 'ass i f F RATINGS - 1 AND 2 HR (SEE ITEM 3) FIRESTOP SYSTEMS T RATING - 0 HR e L s 160, A 2 A SECTION A-A 1. WALL ASSEMBLY - MIN 3-W4 IN. THICK REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF) CONCRETE. WALL MAY ALSO BE CONSTRUCTED • ANY UL CLASSIFIED CONCRETE BLOCKS*. MAX DIAMETER OF OPENING 10-1/2 IN. SEE CONCRETE BLOCKS (CAZT) CATEGORY IN THE FIRE RESISTANCE DIRECTORY FOR NAMES OF MANUFACTURERS. 2. THROUGH-PENETRANTS - ONE METALLJC PIPE, CONDUIT OR TUBING TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTO• SYSTEM. AN ANNULAR SPACE OF MIN 114 IN. TO MAX 1-5/8 IN. IS REQUIRED WITHIN FIRESTOP SYSTEM. PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES • WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED: A- STEEL PIPE - NOM DIAM O. SMALLER) SCHEDULE 10 (•R HEAVIER) STEEL PIPE. B. IRON PIPE - NOM 8 IN. DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE. C. CONDUIT - NOM 4 IN. DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING (EMT) OR 6 IN. DIAM STEEL CONDUIT. D. COPPER TUBING - NOM DIAM (OR SMALLER) TYPE L (•R HEAVIER) COPPER TUBING. E. COPPER PIPE - NOM 4 IN. DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. F. FLEXIBLE STEEL CONDUIT+ - NOM 2 IN. DIAM (OR SMALLER) FLEXIBLE STEEL CONDUIT. SEE FLEXIBLE METAL CONDUIT (DXUZ) CATEGORY IN THE ELECTRICAL CONSTRUCTION EQUIPMENT DIRECTORY FOR NAMES OF MANUFACTURERS. 3. FIRESTOP SYSTEM - THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: A- PACKING MATERIAL - MIN 2-1/8 IN. OR 2-W4 IN. THICKNESS • MIN 4 PCF MINERAL WOOL BATT INSULATION FIRMLY PACKED INTO OPENING • ONE SIDE • THE WALL AS PERMANENT FORM FOR 1 AND 2 HR WALLS, RESPECTIVELY. PACKING MATERIAL TO BE RECESSED FROM ONE SIDE • WALL AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL RIAL B. FILL, VOID OR CAVITY MATERIAL - SEALANT- - MIN I IN. THICKNESS • FILL MATERIAL APPLIED WITHIN OPENING, FLUSH WITH ONE SURFACE OF WALL. 7 SYSTEM NO. W-L-1 054 F RATINGS - I AND 2 HR (SEE ITEMS I AND 3) T RATING - 0 HR L RATING AT AMBIENT - LESS THAN 1 CFMISQ FT L RATING AT 40► F - 4 CFM/SQ FT • 9 -4 • sea • a e e r� Inf6fbaWial b-ic. 811 Ponce De Leon Blvd. Carat Gables, FL m33134 TES (305) 441-1556 httpl/www.s-garchitects.com immmc= 0� PLUMBING LEGEND SYMBOL DESCRIPTION U• U) NEW SANITARY PIPING -------------- F- Z SANITARY VENT PIPING W ct) E HOT WATER PIPING (HIV) U) 2 COLD WATER PIPING (CW) G - W GAS PIPING CD - > 0 CONDENSATE DRAIN PIPING SD- STORM DRAIN PIPING (.) CL � 2 GATE OR BALL VALVE to x CHECK VALVE GAS SHUT-OFF VAVLE U) 0 z "P- TRAP co IF- CLEAN OUT PLUG co R-0 z WALL CLEAN OUT FCO--&- W F- FLUSH FLOOR CLEAN OUT POINT OF CONNECTION CAP _______0 ELBOW TURNED UP D ELBOW TURNED UP 1 NOTE: ALL SYMBOLS INDICATED MAY NOT BE USED ON DRAWINGS PLUMBING SPECIFICATION 1. GENERAL: MATERIAL SHALL BE NEW, UNUSED, BEST OF THEIR RESPECTIVE KINDS AND FREE FROM DEFECTS IN WORKMANSHIP; IN CONFORMANCE WITH THE LATEST PUBLICATIONS IN FORCE AT TIME OF BIDDING. 2. PIPE MATERIAL: A. SANITARY SOIL AND VENT PIPING: (ABOVE GROUND) PVC TYPE DWV AS PER ASTM D 2665, ASTM D 2949, ASTM F 891, CAST IRON AS PER ASTM Z74, ASTM A 888, CISPI 301. ABS PLASTIC PIPE AS PER ASTM D 2661, ASTM F 628, CSA B 181.1. B. SANITARY SOIL AND VENT PIPING: (BELOW GROUND) PVC TYPE DWV AS PER ASTM D 2665, ASTM D 2949, ASTM D 3034. CAST IRON AS PER ASTM A 74, ASTM A 888, CISPI 301, ABS PLASTIC PIPE AS PER ASTM D 2661, ASTM F 628, ASTM D 2751 C. DOMESTIC WATER SUPPLY PIPING: POLYVINYL CHLORIDE (PVC) PLASTIC PIPE AS PER ASTM D 1785; ASTM D 2241; ASTM D 2672; CSA B137.3 D. WATER DISTRIBUTION PIPE: POLYBUTYLENE (PB PLASTIC PIPE AND TUBING: ASTM D 3309; CSA B137.8M 3, JOINTS AND METHODS OF CONNECTION SHALL COMPLY WITH FBC SECTION P605 4. PIPE FITTINGS: SHALL BE APPROVED FOR INSTALLATION WITH THE PIPING MATERIAL INSTALLED AND SHALL CONFORM TO THE RESPECTIVE PIPE STANDARDS OR ONE OF THE STANDARDS LISTED IN TABLE P605.6. ALL PIPE FITTINGS UTILIZED IN WATER SUPPLY SYSTEMS SHALL ALSO CONFORM TO NSF 61. THE FITTINGS SHALL NOT HAVE LEDGES, SHOULDERS OR REDUCTIONS CAPABLE OF RETARDING OR OBSTRUCTING FLOW IN THE PIPING. 5. PIPE INSULATION: A. ALL CONDENSATE LINES SHALL BE INSULATED WITH 3/4' FIRE RETARDANT ARMAFLEX INSULATION WITH A MAXIMUM OF 25/50 FLAME SPREAD AND SMOKE DEVELOPED RESPECTIVELY. B. ALL HOT WATER AND TEMPERED WATER LINES SHALL BE INSULATED WITH 1" FIRE RETARDANT ARMAFLEX INSULATION WITH A MAXIMUM OF 25150 FLAME SPREAD AND SMOKE DEVELOPED RESPECTIVELY. 6. WATER HAMMER: THE FLOW VELOCITY OF THE WATER DISTRIBUTION SYSTEM SHALL BE CONTROLLED TO REDUCE THE POSSIBILITY OF WATER HAMMER. A WATER-HAMMER ARRESTOR SHALL BE INSTALLED WHERE QUICK-CLOSING VALVES ARE UTILIZED. WATER-HAMMER ARRESTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS SPECIFICATIONS. WATER-HAMMER ARRESTORS SHALL CONFORM TO ASSE 1010. 7. ALL VALVES SHALL BE OF THE APPROVED TYPE AND COMPATIBLE WITH THE TYPE OF PIPING MATERIAL INSTALLED IN THE SYSTEM. 8, LOCATION OF FULL-OPEN VALVES. FULL-OPEN VALVES SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: 1. ON THE BUILDING WATER SERVICE PIPE FROM THE PUBLIC WATER SUPPLY NEAR THE CURB. 2. ON THE WATER DISTRIBUTION SUPPLY PIPE AT THE ENTRANCE INTO THE STRUCTURE. 3. ON THE BASE OF EVERY WATER RISER PIPE. 4. ON THE WATER SUPPLY PIPE TO EVERY WATER HEATER. 5. SHUTOFF VALVES SHALL BE INSTALLED IN ON THE WATER SUPPLY PIPE TO EACH APPLIANCE OR MECHANICAL EQUIPMENT. 9. VALVE IDENTIFICATION. SERVICE AND HOSE BIBB VALVES SHALL BE IDENTIFIED. ALL OTHER VALVES INSTALLED IN LOCATIONS THAT ARE NOT ADJACENT TO THE FIXTURE OR APPLIANCE SHALL BE IDENTIFIED, INDICATING THE FIXTURE OR APPLIANCE SERVED. 10. JOINTS BETWEEN DIFFERENT MATERIALS. JOINTS BETWEEN DIFFERENT PIPING MATERIALS SHALL BE MADE WITH A MECHANICAL JOINT OF THE COMPRESSION OR MECHANICAL-SEALING TYPE, OR AS PERMITTED IN §P605.22.1 AND §P605.22.2. CONNECTORS OR ADAPTERS SHALL HAVE AN ELASTOMERIC SEAL CONFORMING TO ASTM D 1869 OR ASTM F 477, JOINTS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS. 11. ESCUTCHEONS: CHROME PLATED OR STAINLESS STEEL WITH SET SCREWS FOR HOLDING SECURELY IN PLACE. USE ESCUTCHEONS ON PIPES PASSING THROUGH WALLS, FLOORS AND CEILINGS OF FINISHED AREAS. 12. THE HOT WATER SUPPLY TO ANY FIXTURE REQUIRING HOT WATER SHALL BE INSTALLED ON THE LEFT SIDE OF THE FIXTURE. 13. HOSE CONNECTIONS. SILLCOCKS, HOSE BIBBS, WALL HYDRANTS AND OTHER OPENINGS WITH A HOSE CONNECTION SHALL BE PROTECTED BY AN ATMOSPHERIC-TYPE OR PRESSURE-TYPE VACUUM BREAKER OR PERMANENTLY ATTACHED HOSE CONNECTION VACUUM BREAKER, DEMOLITION NOTES 1. DEMOLITION • EXISTING PLUMBING WORK SHALL BE PERFORMED AND COMPLETED UNDER THIS SECTION OF THE WORK. 2. DISCONNECT SOIL, WASTE, VENT HOT AND COLD WATER CONNECTIONS FROM EXISTING FIXTURES. 3. REMOVE ALL EXISTING PLUMBING EQUIPMENT, FIXTURES, PIPING NOT REQUIRED, INCLUDING DRAINAGE, WATER, GAS, RAIN WATER LEADERS, AND SATISFY CODE REQUIREMENTS FOR PROHIBITED DEAD ENDS. 4. CAP EXISTING HOT COLD WATER, WASTE, VENT AND SOIL PIPING AT POINT THAT DOES NOT INTERFERE WITH NEW CONSTRUCTION, I.E. BELOW FINISHED FLOOR, BEHIND FINISHED WALLS OR ABOVE HUNG CEILINGS. 5. THE WORK SHALL INCLUDE THE FURNISHING OF ALL MATERIALS, CUT- I TINGS, EXTENSIONS, CONNECTIONS, REPAIRING, ADAPTING AND OTHER WORK INCIDENTAL THERETO, TOGETHER WITH SUCH TEMPORARY CONNECTIONS AS MAY BE REQUIRED. 6. EXISTING FIXTURES, MATERIALS AND EQUIPMENT TO BE REMOVED SHALL BE SALVAGED OR DISPOSED OF AS DIRECTED BY THE OWNER. 7. ANY WORK NOT SHOWN ON THE DRAWINGS OR SPECIFICALLY MENTIONED IN THE SPECIFICATIONS BUT CONSIDERED NECESSARY FOR THE COMPLETION • THE WORK IN PROPER MANNER SHALL BE PROVIDED BY THIS CONTRACTOR WITHOUT ADDITIONAL CHARGE. 8. CONTRACTOR SHALL DO HIS OWN CUTTING AND REMOVAL OF ALL HIS RELATED WORK IN ALL LOCATIONS WHERE REQUIRED, EXCEPT WHERE OTHERWISE SHOWN • THE DRAWINGS AND/011 AS SPECIFIED. • THIS CONTRACTOR SHALL BE RESPONSIBLE FOR ROUGH PATCHING AND REPAIRING. FINISH PATCHING SHALL BE PERFORMED BY GENERAL CONTRACTOR. System No. W-J-2091 SS i G F Rating - 4 Hr FIREST•P SYSTEMS T Rating L Ste'G A /T N 4 A SECTION A-A 1. WALL ASSEMBLY - MIN 8-1/2 IN. THICK REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF) CONCRETE. WALL MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE BLOCKS*. MAX DIAM • OPENING IS 7-3/8 IN. SEE CONCRETE BLOCKS (CAZT) IN VOLUME 1 OF THE FIRE RESISTANCE DIRECTORY FOR NAMES OF MANUFACTURERS. 2. THROUGH PENETRANTS - ONE NONMETALLIC PIPE TO BE INSTALLED CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN THE PIP AND THE PERIPHERY • THE OPENING SHALL BE A MIN 0 IN. (•• INT CONTACT) TO MAX 314 IN. FOR NOM DIAMETER PIPES AND MIN 0 IN. (POINT CONTACT) TO MAX 112 IN. FOR NOM DIAM (OR SMALLER) PIPES. PIPE TO BE RIGIDLY SUPPORTED • BOTH SIDES • WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES • NONMETALLIC PIPES MAY BE USED. A. POLYVINYL CHLORIDE (PVC) PIPE - NOM 6 IN. DIAM (OR SMALLER) SCHEDULE 40 SOLID OR CELLULAR PVC CORE PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING SYSTEMS. B. CHLORINATED POLYVINYL CHLORIDE (PVC) PIPE - NOM 6 IN. DIAM (OR SMALLER) SDR13.5 CPVC PIPE FOR USE IN CLOSED (PR• CESS OR SUPPLY) PIPING SYSTEMS. THE T RATING IS DEPENDENT UPON THE DIAM OF PIPE USED IN THE FIRESTOP SYSTEM. FOR NOM 4 IN. DIAM (OR SMALLER) PIPES, THE T RATING IS 4 HR FOR PIPES GREATER THAN NOM 4 IN. DIAM. THE T RATING IS 2 HR. 3. FIRESTO• SYSTEM - THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: A. FILL, VOID OR CAVITY MATERIAL - SEALANT* - MIN I-W IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS, FLUSH WITH SURFACE • WALL- HIL11 CONSTRUCTION CHEMICALS, DIV OF HILT] FS-ONE SEALANT B. FIRESTO• DEVICE - FIRESTOP COLLAR - THE FIRESTOP COLLAR SHALL BE INSTALLED IN ACCORDANCE WITH THE ACCOMPANYING INSTALIA71ON INSTRUCTIONS. THE COLLAR SHALL BE T INSTALLED AND LATCHED AROUND THE PIPE AND SECURED TO THE CONCRETE WALL WITH THE ANCHOR HOOKS PROVIDED WITH THE COLLAR- (MIN 2 ANCHOR HOOKS FOR 1-1/2 AND 2 IN. DIAM PIPES, 3 ANCHOR HOOKS FOR 3 AND 4 IN. DIAM PIPES AND 4 ANCHOR HOOKS FOR 6 IN. DAM PIPES). THE ANCHOR HOOKS ARE TO BE SECURED TO THE WALL WITH 114 IN. BY 1-1/2 IN. LONG STEEL EXPANSION BOLTS, IN CONJUCTION WITH STEEL NUTS AND MIN 3/4 IN. DIAM STEEL WASHERS WITH ONE ANCHOR BOLT IN EACH ANCHOR HOOK. SYSTEM NO. W-J-1088 'ass i f F RATINGS - 1 AND 2 HR (SEE ITEM 3) FIRESTOP SYSTEMS T RATING - 0 HR e L s 160, A 2 A SECTION A-A 1. WALL ASSEMBLY - MIN 3-W4 IN. THICK REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF) CONCRETE. WALL MAY ALSO BE CONSTRUCTED • ANY UL CLASSIFIED CONCRETE BLOCKS*. MAX DIAMETER OF OPENING 10-1/2 IN. SEE CONCRETE BLOCKS (CAZT) CATEGORY IN THE FIRE RESISTANCE DIRECTORY FOR NAMES OF MANUFACTURERS. 2. THROUGH-PENETRANTS - ONE METALLJC PIPE, CONDUIT OR TUBING TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTO• SYSTEM. AN ANNULAR SPACE OF MIN 114 IN. TO MAX 1-5/8 IN. IS REQUIRED WITHIN FIRESTOP SYSTEM. PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES • WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED: A- STEEL PIPE - NOM DIAM O. SMALLER) SCHEDULE 10 (•R HEAVIER) STEEL PIPE. B. IRON PIPE - NOM 8 IN. DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE. C. CONDUIT - NOM 4 IN. DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING (EMT) OR 6 IN. DIAM STEEL CONDUIT. D. COPPER TUBING - NOM DIAM (OR SMALLER) TYPE L (•R HEAVIER) COPPER TUBING. E. COPPER PIPE - NOM 4 IN. DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. F. FLEXIBLE STEEL CONDUIT+ - NOM 2 IN. DIAM (OR SMALLER) FLEXIBLE STEEL CONDUIT. SEE FLEXIBLE METAL CONDUIT (DXUZ) CATEGORY IN THE ELECTRICAL CONSTRUCTION EQUIPMENT DIRECTORY FOR NAMES OF MANUFACTURERS. 3. FIRESTOP SYSTEM - THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: A- PACKING MATERIAL - MIN 2-1/8 IN. OR 2-W4 IN. THICKNESS • MIN 4 PCF MINERAL WOOL BATT INSULATION FIRMLY PACKED INTO OPENING • ONE SIDE • THE WALL AS PERMANENT FORM FOR 1 AND 2 HR WALLS, RESPECTIVELY. PACKING MATERIAL TO BE RECESSED FROM ONE SIDE • WALL AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL RIAL B. FILL, VOID OR CAVITY MATERIAL - SEALANT- - MIN I IN. THICKNESS • FILL MATERIAL APPLIED WITHIN OPENING, FLUSH WITH ONE SURFACE OF WALL. 7 SYSTEM NO. W-L-1 054 F RATINGS - I AND 2 HR (SEE ITEMS I AND 3) T RATING - 0 HR L RATING AT AMBIENT - LESS THAN 1 CFMISQ FT L RATING AT 40► F - 4 CFM/SQ FT • 9 -4 • sea • a e e r� Inf6fbaWial b-ic. 811 Ponce De Leon Blvd. Carat Gables, FL m33134 TES (305) 441-1556 httpl/www.s-garchitects.com immmc= 0� Se U• U) Z C) F- Z < W ct) E LLJ U) 2 W w LO U_ > 0 Z 0 < q (.) CL � 2 to x < U) 0 z V_ C0 C:) CY) z W F- LLJ Revisions Date M '! a Date: 04.18.2012 Sheet Index '.7'LUMBING LENGEND, IA I NOTES DETAILS AND SCHEDULES Sheet Number Pl-0