12-249-002GENERAL HVAC NOTES I THE CONTRACTOR SHALL FURNISH ALL LABOR MATERIAL AND EQUIPMENT FOR A COMPLETE HVAC SYSTEM IN ACCORDANCE WITH THESE DRAWINGS THE FLORIDA BUILDING CODE 2007 AND THE LATEST EDITION OF THE FOLLOWING PUBLICATIONS: (A) ANS B9:1 MECHANICAL REFRIGERATION (B) NFPA PAMPHLETS 90A & 91 (C) SMACNA (D) ASHRAE 2 ALL AIR CONDITIONING DUCTWORK SHALL BE 1 -1/2 Y STANDARD DUTY FOIL REINFORCED FIBERGLASS (R-6) MANUFACTURED LOGO PRINTED ON THE VAPOR BARRIER WHEN IN UNCONDITIONED SPACE, AND 3/4 " STANDARD DUTY FOIL REINFORCED FIBERGLASS (R-4) MANUFACTURED LOGO PRINTED ON THE VAPOR BARRIER IN CONDITIONED SPACE OR RETURN PLENUM SPACE a ALL EXHAUST DUCTWORK SHALL BE CODE GAGE GALVANIZED SHEET METAL A DUCT SIZE SHOWN ARE NET FREE AREA INSIDE S ALL AIR DEVICES (DIFFUSERS, REGISTERS AND GRILLES) SHALL BE ALL ALUMINUM CONSTRUCTION, WITH EXPOSED SURFACE CHEMICALLY TREATED TO RECEIVE PAINT TO MATCH COLOR OR AIR GUIDE OR APPROVED EQUAL a PROVIDE OPPOSED BLADE DAMPERS AT ALL DIFFUSERS AND REGISTERS 7. THERMOSTATS SHALL BE COMBINATION COOLING / HEATING WITH SYSTEM COOL / AUTO / HEAT / OFF AND FAN ON / AUTO SELECTOR SWITCHES a REFRIGERANT PIPING SHALL BE COPPER TYPE V WITH V2° ARMAFLEX INSULATION SHALL BE PROVIDED FOR SUCTION LINE& R PROVIDE NEW FILTERS FOR FAN COIL BEFORE STARTINQ THESE FILTERS MUST ALSO BE REPLACED PRIOR TO FINAL ACCEPTANCE BY OWNER 10. GENERAL CONTRACTOR IS TO HIRE AN INDEPENDENT TEST AND BALANCE COMPANY WHICH SHALL PROVIDE 3 SET OF THE REPORT SIGN AND SEALED BY THE PROFESSIONAL ENGINEER FROM THE COMPANY PRIOR OF ACCEPTANCE OF WORK it MECHANICAL CONTRACTOR IS TO PROVIDE TURNING VANE AT ALL CHANGE OF DIRECTIONS OR TO PROVIDE TURNING RADIO, ALL OUTLETS SHALL HAVE EXTRACTORS OR SCUPPERS AND SHALL BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE REGULATIONS 12 FLEXIBLE DUCT INSTALLATION AND SUPPORTS TO BE PROVIDED IN ACCORDANCE WITH 2007 FBC -M SEC. 6035.&6 1a FLEXIBLE AND RIGID DUCT RUNS SHALL BE FIELD ADJUSTED TO ENSURE INDIVIDUAL FLEX DUCT LENGTHS DO NOT EXCEED A MAXIMUM OF 14' MEASURED FROM RIGID DUCT TAKEOFFS TO DIFFUSEER CONNECTIONS CONTACT ENGINEER ON RECORD PRIOR TO TO ANY VARIANCES IN RIGID DUCT ROUTING MECHANICAL LEGEND AS PER FBC -M 2007 TABLE 403.3 OUTDOOR AIR CALCULATIONS AREA FLOOR OAL TOTAL CFM / CFM CFM SYSTEM DESIGNATION AREA (NET) TOTAL AIR CFM STATIONS STATION REQUIRED PROVIDED DESIGNATION BEAUTY 1100 X 17 20 17 x 20 = 340 450 A/C -1 2 VENTILATION FAN SCHEDULE UNIT DESIGNATION EF-1 CEILING GRILLE SEE SIZE SCHEDULE OAL OUTSIDE AIR INTAKE 80 LOCATION CEILING DUCT TO MATCH NECK SIZE TYPICAL SR SIDE REGISTER TOTAL AIR CFM 450 X DRIVE TYPE RETURN AIR GRILL CD CEILING DIFFUSER CENTRIFUGAL X CG CEILING GRILL -�� VOLUME DAMPER 2650 a TOTAL STATIC PRESSURE, IN. OF H2O 2.0 LID LINEAR DIFFUSER TQ THERMOSTAT UO.N. UNLESS OTHERWISE NOTED. �P-► RETURN OR EXHAUST, SEE PLANS RTU ROOF TOP UNIT CONNECTED TO EMERGENCY POWER YES AHU AIR HANDLER UNIT MODEL NUMBER WALL MOUNTED SIDE REGISTER CU CONDENSING UNIT BY DESCRIPTION ----EF— 04PM FAN ® EF EXHAUST FAN CFM CUBIC FEET PER MINUTE TF, THERMORN SD DUCT SMOKE DETECTOR UC. UNDERCUT OF UNDERFLOOR TAG TRANSFER AIR GRILLE VENTILATION FAN SCHEDULE UNIT DESIGNATION EF-1 AREA SERVED SALON OPERATING WEIGHT LBS. 80 LOCATION CEILING FAN TYPE INUNE X TOTAL AIR CFM 450 X DRIVE TYPE BELT X FAN WHEEL TYPE CENTRIFUGAL X SMOKE CONTROL 1600 X FAN SPEED, RPM 2650 a TOTAL STATIC PRESSURE, IN. OF H2O 2.0 `` MOTOR HP 3/4 TRANE BACKDRAFT DAMPER YES 3/4 ELECTRICAL SERVICE AVAILABLE 208 -1 -60 UPDATED M.E.P. DRAWINGS CONNECTED TO EMERGENCY POWER YES DESIGN MANUFACTURER GREENHECK MODEL NUMBER I BSQ -80 -7 HVAC DESIGN REQUIRE: YES NO DUCT SMOKE DETECTOR X ELECTRICAL DATA FIRE DAMPERS) AIR HANDLER X SMOKE DAMPERS) SENSIBLE X FIRE RATE ENCLOSURE VOLTS X FIRE RATED ROOF/FLOOR CEILING ASSEMBLY AMPS' X FIRE STOPPING SUC, X SMOKE CONTROL 1600 X ITHERMOSTAT (PROGRAMMABLE) X 80 0 AIR HANDLING UNIT DESIGNATION CFM MBTUH ENTERING F ELECTRICAL DATA MANUFAC. AIR HANDLER OBS TOTAL SENSIBLE WB DB VOLTS PHASES HTNG KW AMPS' FUSES U(, SUC, COND. AHU -1 AHU -2 1600 48 35 67 80 230 1 4,9 20 30 TRANE 4TEE3C10A1 3/8 3/4 3/4 * CONTRACTOR TO PROVIDE MOTORIZED FRESH AIR DAMPERS FOR EACH AHU CONDENSING UNIT DESIGNATION MBTUH TEMR ENT. CONDENSER ELECTRICAL DATA MANUFAC, REF UNIT OBS OR SEER AREA SERVED VOLTS PHASES WIRE AMPS FUSES CU -1 CU -2 48 95 230 1 25 40 TRANE 4TTR5048E1 16 AS SHOWN 12x10 O/A METAL DUCT MOUNT E OF SLAB KEY PLAN NOT TO SCALE PROPOSED FLOOR PLAN - MECHANICAL SCALE: 1/4" = V -0" NE"MmPAR CA #9088 \ /Acz Maqueira Engineering Consultants, Inc. 7487 SW 50th Terrace Miami, Florida 33155 Tel: 305.669.5595 Rolando Maqueira, PE 55482 'S MA � Q`: '�GENSF' •��'� o V : n . M, 5 G 0 48 r • • f° �•; SfA EOF ;• �� A 0,••'•.FL O FLOP'• Q? �s °® SS /O N AA- /'#IIII1111NI -t, A 5/14/2012 FD BUILD. DEPT. COMMENTS 2 06/18/201 JG UPDATED M.E.P. DRAWINGS 1 4/02/2012 JG UPDATED ARCH. M.E.P. DRAWINGS NO. DATE BY DESCRIPTION CONST. REVISIONS IE ABOVE DRAWINGS, IDEAS AND DESIGNS ARE THE PROPERTY OF DEMANDT tCHITECTURE. PJL NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR 3ED IN CONNECTION WITH ANY WORK OTHER THAN THE SPECIFIC PROJECT FOR ACH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECIS. DEMANDT ARCHITECTURE, P,A, 8886 SW 129 TERRACE MECHANICAL MIAMI, FLORIDA 33176 305- 665 -5250 PLAN A A C 2 6 0 0 1 2 9 7i'" FRANK DEMANDT AR -11127 I HEREBY CERTIFY THAT THIS PLAN AND .. SPECIFICATION WAS PREPARED BY ME OR DATE: 03 -02 -12 I AM DU Y REGISTERED STERED ARCHITECTT DRAWN BY: G.C. M - f 2 UNDER THE LAWS OF THE STATE OF FLORIDA, R.M. AS SIGNIFIED BY MY HAND AND SEAL REVIEWED BY: �•s Mr.n,,r.+r.•,r fi /t C CY) LL Q T- 0 O T W I— O U T O CY) � t� JQ R Q Z Y Z a