12-249-022ELECTRICAL LEGEND �A 'A' INDICATES FIXTURE TYPE REFER TO THE LIGHT FIXTURE SCHEDULE RECESSED OR SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE, SIZE AS PER ®` PLAN. RECESSED OR SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE CONNECTED TO EMERGENCY POWER OR WITH BATTERY BACK UP, SIZE AS PER PLAN, CEILING OR ROOF MOUNTED EXHAUST FAN. Fv] DATA OUTLET WALL MOUNTED 18' AFF UNO (STUB UP 3/4' CONDUIT INTO CEILING SPACE) OR FLUSH FLOOR MOUNTED. t TELEPHONE OUTLET WALL MOUNTED AT 18' AFF UNO (STUB UP 3/4' CONDUIT INTO CEILING SPACE) OR FLUSH FLOOR MOUNTER COMBINATION TELEPHONE / DATA OUTLET WALL MOUNTED AT 18' AFF UNO (STUB UP 3/4' CONDUIT INTO CEILING SPACE) OR FLUSH FLOOR MOUNTER Q CABLE TV OUTLET WALL MOUNTED AT 18' AFF UNO (STUB UP 3/4' CONDUIT INTO CEILING SPACE) OR FLUSH FLOOR MOUNTER �y SINGLE RECEPTACLE -120 VOLT,1 PHASE, 3 WIRE, WALL MOUNTED AT 18' AFF UNO OR FLUSH FLOOR MOUNTER q � RECEPTACLE -120 VOLT,1 PHASE 3 WIRE, WALL MOUNTED AT 18' AFF x UNO OR FLUSH FLOOR MOUNTER QUAD RECEPTACLE - 120 VOLT,1 PHASE, 3 WIRE, WALL MOUNTED AT 18' AFF LINO OR FLUSH FLOOR MOUNTED. - GROUND FAULT INTERRUPTER DUPLEX RECEPTACLE -120 VOLT,1 PHASE 3 WIRE, SINGLE RECEPTACLE - 240 VOLT,1 PHASE 4 WIRE MOUNTED AT 18' AFF UNO >� RECESSED MOUNTED ELECTRICAL PANEL. ® SURFACE MOUNTED ELECTRICAL PANEL E;-73 ELECTRICAL SERVICE METER 60 SAFETY DISCONNECT SWITCH. 3 = NO OF POLES, 60 = SWITCH SIZE FUSED AS NF PER MFG, NAMEPLATE NF = NON FUSER (2)1 CEILING MOUNTED EXIT LIGHT, ARROW INDICATES DIRECTION OF EGREES HO WALL MOUNTED EXIT LIGHT, ARROW INDICATES DIRECTION OF EGREES CEILING MOUNTED JUNCTION BOX H� WALL MOUNTED JUNCTION BOX SINGLE POLE TOGGLE SWITCH MOUNTED AT 48' AFF UNO. $2 TWO POLE TOGGLE SWITCH MOUNTED AT 48' AFF UNO. $3 THREE WAY POLE TOGGLE SWITCH MOUNTED AT 48' AFF UNO. FOUR WAY POLE TOGGLE SWITCH MOUNTED AT 48' AFF UNO: $D DIMMER SWITCH 600 WATTS MINIMUM MOUNTED AT 48' AFF UNO $m MANUAL MOTOR RATED STARTER TOGGLE SWITCH WITH THERMAL OVERLOADS Q MANUAL PULL STATION MOUNTED AT 48' AFF SK STROBE LIGHT MOUNTED AT 80' AFF, 75 od UNO. COMBINATION HORN / STROBE MOUNTED AT 80' AFF, 75 Cd UNO. SD FIRE ALARM SMOKE DETECTOR HD FIRE ALARM SMOKE DETECTOR GENERAL NOTES: I ALL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND OTHER APPLICABLE CODES AND STANDARDS, 2 THE CONTRACTOR IS RESPONSIBLE FOR EVALUATING FIELD CONDITIONS BY VISITING THE SITE PRIOR TO COMMENCING/BIDDING WORK. 3. THE CONTRACTOR SHALL SATISFACTORILY REPAIR /REPLACE EQUIPMENT OR PART OF STRUCTURE DAMAGED AS A RESULT OF HIS WORK SURFACES AND FINISHED AREAS SHALL BE RESTORED TO MATCH ADJACENT AREAS 4, APPROVAL SHALL BE OBTAINED FROM THE ENGINEER PRIOR TO CUTTING OR DRILLING ANY STRUCTURAL SUPPORT MEMBER S ALL DEVICE BOXES SHALL BE INSTALLED FLUSH AND CONDUITS RUN CONCEALED IN FINISHED AREAS EXCEPT AS SPECIFICALLY SHOWN/NOTED OTHERWISE 6, WIRE SIZE SHALL BE #12 THHN/THWN STRANDED MINIMUM UNLESS OTHERWISE NOTED ON PLANS. 7. ALL CONDUCTORS SHALL BE COPPER 8. ALL CONDUCTORS SHALL BE RUN IN CONDUIT (METALLIC TYPE1 IF PVC SCHEDULE 40 IS USED FOR UNDERGROUND FEEDERS ONLY, AN EQUIPMENT GROUND CONDUCTOR SIZED IN ACCORDANCE WITH NEC 250-95 MUST BE INSTALLED AND CONDUIT SIZE INCREASED AS REQUIRED. 9: ALL MATERIAL. MUST BE UL APPROVED. 1Q ALL BRANCH CIRCUITS MUST BE PROPERLY PHASE BALANCED. n CONTRACTOR SHALL SEAL ALL FLOOR OPENINGS WITH A FIRE SEAL SIMILAR TO 3M FIRE DAM 1M 12 ALL EMPTY CONDUITS TO BE PROVIDED WITH NYLON PULL STRINGS. 13. FUSES SHALL BE DUAL ELEMENT, TIME DELAY TYPE UNLESS OTHERWISE NOTED, 14 ALL LUMINARIES SHALL BE PROPERLY SUPPORTED IN ACCORDANCE WITH CEILING SYSTEM MANUFACTURER RECOMMENDATIONS AND LOCAL CODE REQUIREMENT& 1S RISERS ARE DIAGRAMMATIC ONLY. THEY DO NOT SHOW EVERY BEND REQUIRED FOR THE INSTALLATION. 16. THIS DRAWING IS A GLADE FOR THE INSTALLATION OF ELECTRICAL SERVICE THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE A FUNCTIONING SYSTEM 17. ALL CABLES SHALL BE RUN WITHOUT SPLICES EXCEPT OTHERWISE INDICATER 18. ALL PULL AND JUNCTION BOXES SHALL BE ACCESSIBLE AT ALL TIMES 19L EXACT POINT AND METHODS OF CONNECTION SHALL BE DETERMINED IN FIELD. 201 ALL WORK SHALL BE DONE IN A NEAT WORKMANLIKE MANNER CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, FIRE ALARM SYSTEM SPECIFICATION SHEETS AND ALL BATTERY CALCULATIONS TO THE BUILDING DEPARTMENT AND THE ENGINEER FOR REVIEW PRIOR TO ACQUIRING THE PERMIT. N m A -3709 ^� EXISTING PANELS 'BW 'BIB' TO BE RELOCATED AS SHOWN, TO RISER DIAGRAM RECONNECT ALL EXISTING BRANCH CIRCLAT LOADS, EXTEND �... CONDUIT & WIRE AS REQUIRED 10, i) vmz 0 A.D.A. )ILET ROOM SKI i EX r EXIST. STarR N6.2 jA -36 A-3426 - _..... -- -2527 A -34,36 - - - A-34 < _ ('6 BREAK T ROOM HALLWAY ///EXIST. - -- ATM ROOM � WAITING ;tom_ ^, AREA m 11 A- A -13 RECEPTION NAIL _ ,tt............ a_4. .... DRYER AREA AIS i •� i4 1 9 f/ffff/ EXIST. HAND & STONE MASSAGE & FACIAL SPA NO WORK IN THIS / / / / //. AREA % G i Rwn O r W cr- D O C6 T- o LO Q N CL Q J U z Q M 1 14/02/20121 JG I UPDATED ARCH, M.E.P. WANANGS N0. I DATE I BY I DESCRIPTION CONST. REVISIONS ai •• • •'.` •. a' '7 •' Y Z a DEMANDT ARCHITECTM, PA, 8886 SW 129 TERRACE POWER MIAMI, FLORIDA 33176 KEY PLAN PROPOSED FLOOR PLAN - POWER & COMM p 305-66550 A A C 2 6 0 0 - 0 1 12 5 2 9 7 PLAN 1 � 7 FRANK DEMANDT AR-1 1127 NOT TO SCALE E -1.1 SCALE: 1/4" = 1' -0" 1 HEREBY CERTIFY THAT THIS PLAN AND p SPECIFUCATION WAS PREPARED BY ME OR DATE: 03 -02 -12 m UNDER MY DIRECT AM DULY REGISTERED ARCHITECT T DRAWN BY: G.G. E-1.1 UNDER THE LAWS OF THE STATE OF FLORA, AS SIGNIFIED BY MY HAND AND SEAL REVIEWED BY: R.M.