Loading...
12-249-012DEMOLITION REFLECTED CEILING PLAN SCALE: 1/4" = V -0" DEMOLITION FL• • PAN KEYED NOTES LEGErD 1❑ PARTIAL EXIST. PARTITION WALL TO REMAIN 2❑ EXIST. CABINETRY AND SINK TO BE DEMOLISHED l3 EXIST. WOMEN'S TOILET ROOM TO REMAIN. EXIST. SINK TO BE REMOVED AND RELOCATED. SEE SHEET Al A FOR NEW LOCATION. EXIST. SEMI — RECESSED TOILET PAPER DISPENSER " BE DEMOLISHED. BOTH EXIST, GRAB BARS TO REMAIN 7❑ EXIST. WATER CLOSET TO REMAIN. 8❑ EXIST. COUNTERTOP & MIRROR TO REMAIN. EXIST. STRUCTURAL CONIC, COLUMN TO REMAIN. 10 EXIST, UTILITY SINK TO BE DEMOLISHED. 11 EXIST. TILE FLOOR FINISH, WATER CLOSET, GRAB EIS & SINK TO BE DEMOLISHED, Fl- 2 EXIST, ELECTRICAL PANEL B -1 A. SEE ELECTRICAL: 13 EXIST. ELECTRICAL PANEL B -1 B. SEE ELECTRICAL. 14 EXIST. BANK TELLER CABINETRY TO BE DEMOLISHE JUST BEYOND NEW DEMISING WALL LOCATION. 15 EXIST. PARTITION WALL TO BE DEMOLISHED. 16 EXIST. CONIC. STRUCTURAL COLUMN TO REMAIN. 17 EXIST, PARTITION WALL AROUND CONIC. STRUCTUF_ COLUMN TO BE DEMOLISHED. 18 EXIST. SEMI — RECESSED, WALL MOUNTED, FIRE— EXINGUISHER TO BE RELOCATED. SEE SHT. Al. FOR NEW LOCATION, 19 NEW LOCATION OF 2 —HR. FIRE RATED DEMISING WA. 20 EXIST. DEMISING WALL TO REMAIN. 21 EXIST. PARTIAL STOREFRONT TO BE DEMOLISHED`Q PAIR OF NEW STOREFRONT DOOR. 22 EXIST. WALL PARTITION & WALL CLEAN —OUT TO PEWN, 23 EXIST. FLOOR CLEAN —OUT TO REMAIN. 24 DIMENSION TO FACE —OF —STUD OF NEW 2 —HR, FIRI —NTED DEMISING WALL. 25 EXIST. CARPET FLOOR FINISH TO BE DEMOLISHEDR LOCATION OF NEW DEMISING WALL LOCATION. FIELD COORDINATE, 26 EXIST. WOOD LAMINATE FLOORING TO BE DEMOUSED TO LOCATION OF NEW DEMISING WALL LOCATION. FIELD COORDINATE. 27 EXIST. VOT TILE FLOORING TO BE DEMOLISHED TO LOCATION OF NEW DEMISING WALL LOCATION. FIELD COORDINATE. DEMO. REF. CEILING PL,N KEYED NOTES LEGEN) 1l CEILING IN EXIST. WOMENS TOILET ROOM TO RENA'. F2] CEILING IN EXIST. MENS TOILET ROOM TO REMAIN OEXIST. 2x2 FLOURESCENT LIGHT FIXTURE TO BE REMOVED & RELOCATED. SEE SHEET A1,1 FOR NEW LOCATION. 4� EXIST, DRYWALL SOFFIT, LOUVER &TUBE LIGHT RCIRE TO BE DEMOLISHED TO JUST BEYOND LINE OF NEW DEMISING WALL. EXIST. 2x2 FLOURESCENT LIGHT FIXTURE TO BE REVVED & RELOCATED. SEE SHEET A1.1 FOR NEW LOCATIOI 6❑ BOTH 2x2 FLOURESCENT LIGHT FIXTURE TO BE DEMOLISHED. 7� EXIST. ACT TO BE DEMOLISHED TO JUST BEYOND Ul OF NEW DEMISING WALL, EXIST. ACT CEIILNG Q 11' -0" A.F.F. TO REMAIN. EXIST. FIRE SPRINKLER HEAD TO BE RELOCATED, SEE FIRE SPRINKLER PLAN. 10 EXIST. FIRE SPRINKLER HEAD TO REMAIN. 11 EXIST. A/C SUPPLY GRILL & DUCTWORK TO BE REMC—D. 12 EXIST, A/C RETURN GRILL & DUCTWORK TO BE REM (ED, EXIST STOREFRONT TO BE REM VED FOR EW PAIR OF STOREFRO DOORS. SEE SHEET A1.4 FOR NEW DOORS. NOTE: IF POSSIBLE EXISTING STOREFRONT TO BE RE —USED EXIST. STOREFRONT ELE/ATION O[� 2 DEMOLITION A -0.4 = � SCALE: 1 /4 - T-0" f �/ '' ,',j�.,fV,�✓,j`f ,,.EXIST,, . EXIST. 7 /PANEL B 1A STAIR NO 2 EXIST. PANEL ` PANEL B -1 B HALLWAY j ✓r,; f j' ( t t EXIST. f✓ j j, f F fj j r I ICLOSETt t EXIST. j '% .M EN S TOILET F= { s 15 II E ii LL ER LINE � t j f 1 t EXIST. BREAK ROOM i i' j ' - r r t j L - - - -w. E_ - - , --------- --- _ -#1- tL s � F i -------------- X, ' 21'-10" ABANDONED jj1 HSBC BANK 20 NO WORK IN THIS f' j AREA l ;fir. ,,`j' fff�f rr'� ✓""• `,` I ( EXIST. r /0>X I PLATFORM r I I I EXIST. ;rj" tI WAITING EXIST. f ATM ROOM FLOOR DEMOLITION V-10" 23 A -0.5 2 21 D. W // , j �,j r' /, ,✓ /� rrrj ,, HAND & STONE !j MASSAGE & FACIAL SPA X j NO WORK IN THIS AREA ,' � � rfr ,✓' ✓ � r�,,� GENERAL NOTES 1, GENERAL CONTRACTOR TO VISIT SITE & FAMILIARIZE THEMSELVES WITH ALL EXISTING & PROPOSED CONDITIONS OF PROJECT PRIOR TO COMMENCEMENT OF ANY WORK. 2, GENERAL CONTRACTOR SHALL FURNISH LABOR & EQUIPMENT TO DISCONNECT, DISMANTLE, REMOVE & SALVAGE IN THE DISPOSITION OF THE DEMOLITION INDICATED ON THESE PLANS. 3. GENERAL CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PREVENT DAMAGE TO EXISTING STRUTURE & EQUIPMENT TO REMAIN & SHALL BE FULLY RESPONSIBLE FOR ANY DAMAGE TO EXISTING STRUCTURE OR EQUIPMENT CAUSED BY THE OPERATION. 4, UPON COMPLETION OF THE DEMOLITION, THE ENTIRE AREA SHALL BE CLEANED OF ALL DEBRIS AND PREPARED FOR THE PROPOSED CONSTRUCTION 5. EXISTING CONDITIONS NOT SHOWN ON THE DEMOLITION/EXISTING PLAN DRAWINGS SHALL BE REMOVED & REWORKED TO CONFORM TO THE PROPOSED PLANS AS REQUIRED. 6. GENERAL CONTRACTOR IS RESPONSIBLE FOR THE PROVISIONS OF BARRICADES & ALL OTHER SAFETY EQUIPMENT AS REQUIRED B THE CONDITIONS OF THE PROJECT SITE. 7. WHEN AN ITEM OR CONSTRUCTION ELEMENT IS NOTED TO BE REMOVED, ALL ACCESSORIES, EQUIPMENT, PLUMBING & ELECTRICAL CONNECTIONS, FLASHINGS, SIGNS FRAMING &ALL ASSOCIATED CONNECTING ITEMS, ETC. SHALL BE REMOVED ALONG WITH IT. I THE EXISTING CONSTRUCTION, WHICH SHALL REMAAN, SHALL BE LEFT FREE OF THESE ITEMS & ANY OTHER LOSE CONSTRUCTION & SHALL BE READY TO RECIEVE NEW WORK, PATCHED & REPAIRED TO MATCH EXISTING &/OR ADJOINING AREA. S. GENERAL CONTRACTOR SHALL CONTACT & REQUEST FROM ANY &ALL UTILITY COMPANIES AS MAY BE REQUIRED, SURVEYS LOCATING EXISING CONDITIONS OF THE PROJECT SITE. 9. GENERAL CONTRACTOR SHALL INFORM & COORDINATE W/ BUILDING MANAGEMENT LOCATION OF DUMPSTERS, ETC. SO AS NOT TO DISRUPT OTHER TENANTS. 10. GENERAL CONTRACTOR TO NOTIFY ARCHITECT/ENGINEER IMMEDIATELY WHEN ANY DISCREPANCIES ARISE, 11. UPON REMOVAL OF ALL FINISHES & EXPOSURE OF STRUCTURE & HIDDEN CONDITIONS, GENERAL CONTRACTOR TO NOTIFY ARCHITECT] FOR FIELD INSPECTION BEFORE CONTINUING, UNLESS SO STATED BY THE ARCHITECT. 12, ANY FIRE EXTINGUISHERS MOVED DURING CONSTRUCTION ARE TO BE RELOCATED AT AN ADJACENT AREA AS PER NFPA REQUIREMENTS, 13, THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR IDENTIFYING, TAGGING OUT ANDh LOCKING OUT ALL AFFECTED CIRCUITS PRIOR TO THE COMMENCEMENT OF DEMOLITION. THE ELECTRICAL CONTRACTOR SHALL ALSO BE REQUIRED TO REMOVE ALL UNUSED CONDUITS;& CONDUCTORS & PROPERLY SUPPORT ALL EXISTING CONDUITS & CONDUCTORS THAT WILL REMAIN PRIOR TO THE START OF NEW WORK. 1 14. ANY DISCREPANCIES BETWEEN DRAWINGS & FIELD CONDITIONS TO BE REPORTED TO ARCHITECT IMMEDIATELY. 15, ALL EXISTING CONDITIONS, DIMENSIONS AND MATERIALS OF CONSTRUCTION ARE TO BE VERIFIED IN THE FIELD PRIOR TO ANY DEMOLITION WORK OR ANY NEW CONSTRUCTION. 16. AREAS OF BUILDING NOT PART OF THIS REMODEL TO BE PROTECTED FROM DUST & DAMAGE DURING REMODEL. 17, ANY MATERIALS INSTALLED ABOVE CEILING DURING REMODEL SHALL BE NON — COMBUSTIBLE W ACCORDANCE W/ NFPA 13. 18, THE REMOVAL OF ALL UTILITIES & SYSTEMS SHALL BE TO THEIR FURTHEST POINT OF ORIGIN, 19. SLAB CUTS TO BE COORDINATED W/ REQUIRED DISCIPLINES & SUB — CONTRACTORS PRIOR TO COMMENCEMENT. 20. ALL DEMOLITION WILL BE PERFORMED IN SUCH A MANNER SO NOT TO BLOCK OR RESTRICT ANY MEANS OF EGRESS, AS PER FBC 2010, SECTION "1303.3 "MEANS OF EGRESS ". 21, GENERAL CONTRACTOR TO COORDINATE THE REMOVAL OF ALL FIXTURES W/ OWNER FOR DESIRED REMOVAL/SALVAGING/REUSE. 1 SYMBOLS LEGEND _ I ------ EXISTING TO BE DEMOLISHED co T` J LL Q 2 H O 0 cc) r W rr H H U Lo cfj T 0 r*__ L J N n V z r'j ` , %` ✓rj EXISTING WALL cf) EXISTING COLUMN L.1 r r^ /X I N0. DATE BY DESCRIPTION CONST. III; REVISIONS THE ABOVE DRAWINGS, IDEAS AND DESIGNS AREITHE PROPERTY OF DEMANDT - ARCHITECTURE, PA NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONNECTION WITH ANY WORK OTHER THAN THE SPEC'.,FIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECTS. ... -.. DEMANDIT =f G TECTURE, P.A. DEMOLITION F F tg ` - W 129 TERRACE FLOOR PLAN & ;7 *•' "'" • Ili,: FLORIDA 3 317 6 REFLECTED l� s• 0 � "w-'� 6 5 - 5 2 5 ID �•�° 4 CEILING PLAN 6001297 F'I;�A MANDT AR -11127 CE RTIFY THAT THIS PLAN AND SPEGIACATION WAS PREPARED BY ME OR DATE: 03 -02 -12 Rtoll F 7GNb MY DIRECT SUPERVISION AND THAT J G A-0.4 P. AA DULY REGISTERED ARCHITECT DRAWN BY: "•e�R:s�UNDERE LAWS OF THE STATE OF FLORIDA, a F.D. A5 "SIGNIFIED BY MY HAND AND SEAL REVIEWED BY: ✓ 1 'r / _ EXIST STOREFRONT TO BE REM VED FOR EW PAIR OF STOREFRO DOORS. SEE SHEET A1.4 FOR NEW DOORS. NOTE: IF POSSIBLE EXISTING STOREFRONT TO BE RE —USED EXIST. STOREFRONT ELE/ATION O[� 2 DEMOLITION A -0.4 = � SCALE: 1 /4 - T-0" f �/ '' ,',j�.,fV,�✓,j`f ,,.EXIST,, . EXIST. 7 /PANEL B 1A STAIR NO 2 EXIST. PANEL ` PANEL B -1 B HALLWAY j ✓r,; f j' ( t t EXIST. f✓ j j, f F fj j r I ICLOSETt t EXIST. j '% .M EN S TOILET F= { s 15 II E ii LL ER LINE � t j f 1 t EXIST. BREAK ROOM i i' j ' - r r t j L - - - -w. E_ - - , --------- --- _ -#1- tL s � F i -------------- X, ' 21'-10" ABANDONED jj1 HSBC BANK 20 NO WORK IN THIS f' j AREA l ;fir. ,,`j' fff�f rr'� ✓""• `,` I ( EXIST. r /0>X I PLATFORM r I I I EXIST. ;rj" tI WAITING EXIST. f ATM ROOM FLOOR DEMOLITION V-10" 23 A -0.5 2 21 D. W // , j �,j r' /, ,✓ /� rrrj ,, HAND & STONE !j MASSAGE & FACIAL SPA X j NO WORK IN THIS AREA ,' � � rfr ,✓' ✓ � r�,,� GENERAL NOTES 1, GENERAL CONTRACTOR TO VISIT SITE & FAMILIARIZE THEMSELVES WITH ALL EXISTING & PROPOSED CONDITIONS OF PROJECT PRIOR TO COMMENCEMENT OF ANY WORK. 2, GENERAL CONTRACTOR SHALL FURNISH LABOR & EQUIPMENT TO DISCONNECT, DISMANTLE, REMOVE & SALVAGE IN THE DISPOSITION OF THE DEMOLITION INDICATED ON THESE PLANS. 3. GENERAL CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PREVENT DAMAGE TO EXISTING STRUTURE & EQUIPMENT TO REMAIN & SHALL BE FULLY RESPONSIBLE FOR ANY DAMAGE TO EXISTING STRUCTURE OR EQUIPMENT CAUSED BY THE OPERATION. 4, UPON COMPLETION OF THE DEMOLITION, THE ENTIRE AREA SHALL BE CLEANED OF ALL DEBRIS AND PREPARED FOR THE PROPOSED CONSTRUCTION 5. EXISTING CONDITIONS NOT SHOWN ON THE DEMOLITION/EXISTING PLAN DRAWINGS SHALL BE REMOVED & REWORKED TO CONFORM TO THE PROPOSED PLANS AS REQUIRED. 6. GENERAL CONTRACTOR IS RESPONSIBLE FOR THE PROVISIONS OF BARRICADES & ALL OTHER SAFETY EQUIPMENT AS REQUIRED B THE CONDITIONS OF THE PROJECT SITE. 7. WHEN AN ITEM OR CONSTRUCTION ELEMENT IS NOTED TO BE REMOVED, ALL ACCESSORIES, EQUIPMENT, PLUMBING & ELECTRICAL CONNECTIONS, FLASHINGS, SIGNS FRAMING &ALL ASSOCIATED CONNECTING ITEMS, ETC. SHALL BE REMOVED ALONG WITH IT. I THE EXISTING CONSTRUCTION, WHICH SHALL REMAAN, SHALL BE LEFT FREE OF THESE ITEMS & ANY OTHER LOSE CONSTRUCTION & SHALL BE READY TO RECIEVE NEW WORK, PATCHED & REPAIRED TO MATCH EXISTING &/OR ADJOINING AREA. S. GENERAL CONTRACTOR SHALL CONTACT & REQUEST FROM ANY &ALL UTILITY COMPANIES AS MAY BE REQUIRED, SURVEYS LOCATING EXISING CONDITIONS OF THE PROJECT SITE. 9. GENERAL CONTRACTOR SHALL INFORM & COORDINATE W/ BUILDING MANAGEMENT LOCATION OF DUMPSTERS, ETC. SO AS NOT TO DISRUPT OTHER TENANTS. 10. GENERAL CONTRACTOR TO NOTIFY ARCHITECT/ENGINEER IMMEDIATELY WHEN ANY DISCREPANCIES ARISE, 11. UPON REMOVAL OF ALL FINISHES & EXPOSURE OF STRUCTURE & HIDDEN CONDITIONS, GENERAL CONTRACTOR TO NOTIFY ARCHITECT] FOR FIELD INSPECTION BEFORE CONTINUING, UNLESS SO STATED BY THE ARCHITECT. 12, ANY FIRE EXTINGUISHERS MOVED DURING CONSTRUCTION ARE TO BE RELOCATED AT AN ADJACENT AREA AS PER NFPA REQUIREMENTS, 13, THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR IDENTIFYING, TAGGING OUT ANDh LOCKING OUT ALL AFFECTED CIRCUITS PRIOR TO THE COMMENCEMENT OF DEMOLITION. THE ELECTRICAL CONTRACTOR SHALL ALSO BE REQUIRED TO REMOVE ALL UNUSED CONDUITS;& CONDUCTORS & PROPERLY SUPPORT ALL EXISTING CONDUITS & CONDUCTORS THAT WILL REMAIN PRIOR TO THE START OF NEW WORK. 1 14. ANY DISCREPANCIES BETWEEN DRAWINGS & FIELD CONDITIONS TO BE REPORTED TO ARCHITECT IMMEDIATELY. 15, ALL EXISTING CONDITIONS, DIMENSIONS AND MATERIALS OF CONSTRUCTION ARE TO BE VERIFIED IN THE FIELD PRIOR TO ANY DEMOLITION WORK OR ANY NEW CONSTRUCTION. 16. AREAS OF BUILDING NOT PART OF THIS REMODEL TO BE PROTECTED FROM DUST & DAMAGE DURING REMODEL. 17, ANY MATERIALS INSTALLED ABOVE CEILING DURING REMODEL SHALL BE NON — COMBUSTIBLE W ACCORDANCE W/ NFPA 13. 18, THE REMOVAL OF ALL UTILITIES & SYSTEMS SHALL BE TO THEIR FURTHEST POINT OF ORIGIN, 19. SLAB CUTS TO BE COORDINATED W/ REQUIRED DISCIPLINES & SUB — CONTRACTORS PRIOR TO COMMENCEMENT. 20. ALL DEMOLITION WILL BE PERFORMED IN SUCH A MANNER SO NOT TO BLOCK OR RESTRICT ANY MEANS OF EGRESS, AS PER FBC 2010, SECTION "1303.3 "MEANS OF EGRESS ". 21, GENERAL CONTRACTOR TO COORDINATE THE REMOVAL OF ALL FIXTURES W/ OWNER FOR DESIRED REMOVAL/SALVAGING/REUSE. 1 SYMBOLS LEGEND _ I ------ EXISTING TO BE DEMOLISHED co T` J LL Q 2 H O 0 cc) r W rr H H U Lo cfj T 0 r*__ L J N n V z r'j ` , %` ✓rj EXISTING WALL cf) EXISTING COLUMN L.1 r r^ /X I N0. DATE BY DESCRIPTION CONST. III; REVISIONS THE ABOVE DRAWINGS, IDEAS AND DESIGNS AREITHE PROPERTY OF DEMANDT - ARCHITECTURE, PA NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONNECTION WITH ANY WORK OTHER THAN THE SPEC'.,FIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECTS. ... -.. DEMANDIT =f G TECTURE, P.A. DEMOLITION F F tg ` - W 129 TERRACE FLOOR PLAN & ;7 *•' "'" • Ili,: FLORIDA 3 317 6 REFLECTED l� s• 0 � "w-'� 6 5 - 5 2 5 ID �•�° 4 CEILING PLAN 6001297 F'I;�A MANDT AR -11127 CE RTIFY THAT THIS PLAN AND SPEGIACATION WAS PREPARED BY ME OR DATE: 03 -02 -12 Rtoll F 7GNb MY DIRECT SUPERVISION AND THAT J G A-0.4 P. AA DULY REGISTERED ARCHITECT DRAWN BY: "•e�R:s�UNDERE LAWS OF THE STATE OF FLORIDA, a F.D. A5 "SIGNIFIED BY MY HAND AND SEAL REVIEWED BY: