12-249-012DEMOLITION REFLECTED CEILING PLAN
SCALE: 1/4" = V -0"
DEMOLITION FL• • PAN
KEYED NOTES LEGErD
1❑ PARTIAL EXIST. PARTITION WALL TO REMAIN
2❑ EXIST. CABINETRY AND SINK TO BE DEMOLISHED
l3 EXIST. WOMEN'S TOILET ROOM TO REMAIN.
EXIST. SINK TO BE REMOVED AND RELOCATED.
SEE SHEET Al A FOR NEW LOCATION.
EXIST. SEMI — RECESSED TOILET PAPER DISPENSER "
BE DEMOLISHED.
BOTH EXIST, GRAB BARS TO REMAIN
7❑ EXIST. WATER CLOSET TO REMAIN.
8❑ EXIST. COUNTERTOP & MIRROR TO REMAIN.
EXIST. STRUCTURAL CONIC, COLUMN TO REMAIN.
10 EXIST, UTILITY SINK TO BE DEMOLISHED.
11 EXIST. TILE FLOOR FINISH, WATER CLOSET, GRAB EIS
& SINK TO BE DEMOLISHED,
Fl- 2 EXIST, ELECTRICAL PANEL B -1 A. SEE ELECTRICAL:
13 EXIST. ELECTRICAL PANEL B -1 B. SEE ELECTRICAL.
14 EXIST. BANK TELLER CABINETRY TO BE DEMOLISHE
JUST BEYOND NEW DEMISING WALL LOCATION.
15 EXIST. PARTITION WALL TO BE DEMOLISHED.
16 EXIST. CONIC. STRUCTURAL COLUMN TO REMAIN.
17 EXIST, PARTITION WALL AROUND CONIC. STRUCTUF_
COLUMN TO BE DEMOLISHED.
18 EXIST. SEMI — RECESSED, WALL MOUNTED,
FIRE— EXINGUISHER TO BE RELOCATED. SEE SHT. Al.
FOR NEW LOCATION,
19 NEW LOCATION OF 2 —HR. FIRE RATED DEMISING WA.
20 EXIST. DEMISING WALL TO REMAIN.
21 EXIST. PARTIAL STOREFRONT TO BE DEMOLISHED`Q
PAIR OF NEW STOREFRONT DOOR.
22 EXIST. WALL PARTITION & WALL CLEAN —OUT TO PEWN,
23 EXIST. FLOOR CLEAN —OUT TO REMAIN.
24 DIMENSION TO FACE —OF —STUD OF NEW 2 —HR, FIRI —NTED
DEMISING WALL.
25 EXIST. CARPET FLOOR FINISH TO BE DEMOLISHEDR
LOCATION OF NEW DEMISING WALL LOCATION.
FIELD COORDINATE,
26 EXIST. WOOD LAMINATE FLOORING TO BE DEMOUSED
TO LOCATION OF NEW DEMISING WALL LOCATION.
FIELD COORDINATE.
27 EXIST. VOT TILE FLOORING TO BE DEMOLISHED
TO LOCATION OF NEW DEMISING WALL LOCATION.
FIELD COORDINATE.
DEMO. REF. CEILING PL,N
KEYED NOTES LEGEN)
1l CEILING IN EXIST. WOMENS TOILET ROOM TO RENA'.
F2] CEILING IN EXIST. MENS TOILET ROOM TO REMAIN
OEXIST. 2x2 FLOURESCENT LIGHT FIXTURE TO BE
REMOVED & RELOCATED. SEE SHEET A1,1 FOR
NEW LOCATION.
4� EXIST, DRYWALL SOFFIT, LOUVER &TUBE LIGHT RCIRE
TO BE DEMOLISHED TO JUST BEYOND LINE OF
NEW DEMISING WALL.
EXIST. 2x2 FLOURESCENT LIGHT FIXTURE TO BE REVVED
& RELOCATED. SEE SHEET A1.1 FOR NEW LOCATIOI
6❑ BOTH 2x2 FLOURESCENT LIGHT FIXTURE TO BE
DEMOLISHED.
7� EXIST. ACT TO BE DEMOLISHED TO JUST BEYOND Ul
OF NEW DEMISING WALL,
EXIST. ACT CEIILNG Q 11' -0" A.F.F. TO REMAIN.
EXIST. FIRE SPRINKLER HEAD TO BE RELOCATED,
SEE FIRE SPRINKLER PLAN.
10 EXIST. FIRE SPRINKLER HEAD TO REMAIN.
11 EXIST. A/C SUPPLY GRILL & DUCTWORK TO BE REMC—D.
12 EXIST, A/C RETURN GRILL & DUCTWORK TO BE REM (ED,
EXIST STOREFRONT TO BE REM VED
FOR EW PAIR OF STOREFRO DOORS.
SEE SHEET A1.4 FOR NEW DOORS.
NOTE:
IF POSSIBLE EXISTING STOREFRONT TO BE
RE —USED
EXIST. STOREFRONT ELE/ATION
O[� 2 DEMOLITION
A -0.4 =
� SCALE: 1 /4 - T-0"
f
�/ '' ,',j�.,fV,�✓,j`f ,,.EXIST,, .
EXIST. 7 /PANEL B 1A
STAIR NO 2
EXIST.
PANEL `
PANEL B -1 B
HALLWAY
j ✓r,; f j' ( t t EXIST.
f✓ j j, f F fj j r I ICLOSETt t EXIST.
j '% .M EN S TOILET
F= {
s
15 II E ii
LL ER LINE
� t
j f 1 t EXIST.
BREAK ROOM i
i' j ' -
r r t
j
L - - - -w. E_ - - ,
--------- ---
_ -#1-
tL
s
�
F i
--------------
X,
' 21'-10"
ABANDONED jj1
HSBC BANK
20
NO WORK IN THIS
f' j AREA
l ;fir. ,,`j' fff�f rr'� ✓""• `,` I (
EXIST.
r
/0>X I PLATFORM
r I I I EXIST.
;rj" tI WAITING
EXIST. f
ATM ROOM
FLOOR DEMOLITION
V-10"
23
A -0.5
2
21
D. W
// , j �,j r' /, ,✓ /�
rrrj ,,
HAND & STONE !j
MASSAGE & FACIAL
SPA
X j
NO WORK IN THIS
AREA
,' � � rfr ,✓' ✓ � r�,,�
GENERAL NOTES
1, GENERAL CONTRACTOR TO VISIT SITE & FAMILIARIZE
THEMSELVES WITH ALL EXISTING & PROPOSED
CONDITIONS OF PROJECT PRIOR TO COMMENCEMENT OF
ANY WORK.
2, GENERAL CONTRACTOR SHALL FURNISH LABOR &
EQUIPMENT TO DISCONNECT, DISMANTLE, REMOVE &
SALVAGE IN THE DISPOSITION OF THE DEMOLITION
INDICATED ON THESE PLANS.
3. GENERAL CONTRACTOR SHALL TAKE ALL NECESSARY
PRECAUTIONS TO PREVENT DAMAGE TO EXISTING
STRUTURE & EQUIPMENT TO REMAIN & SHALL BE FULLY
RESPONSIBLE FOR ANY DAMAGE TO EXISTING STRUCTURE
OR EQUIPMENT CAUSED BY THE OPERATION.
4, UPON COMPLETION OF THE DEMOLITION, THE ENTIRE
AREA SHALL BE CLEANED OF ALL DEBRIS AND PREPARED
FOR THE PROPOSED CONSTRUCTION
5. EXISTING CONDITIONS NOT SHOWN ON THE
DEMOLITION/EXISTING PLAN DRAWINGS SHALL BE
REMOVED & REWORKED TO CONFORM TO THE PROPOSED
PLANS AS REQUIRED.
6. GENERAL CONTRACTOR IS RESPONSIBLE FOR THE
PROVISIONS OF BARRICADES & ALL OTHER SAFETY
EQUIPMENT AS REQUIRED B THE CONDITIONS OF THE
PROJECT SITE.
7. WHEN AN ITEM OR CONSTRUCTION ELEMENT IS NOTED TO
BE REMOVED, ALL ACCESSORIES, EQUIPMENT, PLUMBING
& ELECTRICAL CONNECTIONS, FLASHINGS, SIGNS
FRAMING &ALL ASSOCIATED CONNECTING ITEMS, ETC.
SHALL BE REMOVED ALONG WITH IT. I THE EXISTING
CONSTRUCTION, WHICH SHALL REMAAN, SHALL BE LEFT
FREE OF THESE ITEMS & ANY OTHER LOSE
CONSTRUCTION & SHALL BE READY TO RECIEVE NEW
WORK, PATCHED & REPAIRED TO MATCH EXISTING &/OR
ADJOINING AREA.
S. GENERAL CONTRACTOR SHALL CONTACT & REQUEST
FROM ANY &ALL UTILITY COMPANIES AS MAY BE
REQUIRED, SURVEYS LOCATING EXISING CONDITIONS OF
THE PROJECT SITE.
9. GENERAL CONTRACTOR SHALL INFORM & COORDINATE
W/ BUILDING MANAGEMENT LOCATION OF DUMPSTERS,
ETC. SO AS NOT TO DISRUPT OTHER TENANTS.
10. GENERAL CONTRACTOR TO NOTIFY ARCHITECT/ENGINEER
IMMEDIATELY WHEN ANY DISCREPANCIES ARISE,
11. UPON REMOVAL OF ALL FINISHES & EXPOSURE OF
STRUCTURE & HIDDEN CONDITIONS, GENERAL
CONTRACTOR TO NOTIFY ARCHITECT] FOR FIELD
INSPECTION BEFORE CONTINUING, UNLESS SO STATED BY
THE ARCHITECT.
12, ANY FIRE EXTINGUISHERS MOVED DURING CONSTRUCTION
ARE TO BE RELOCATED AT AN ADJACENT AREA AS PER
NFPA REQUIREMENTS,
13, THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE
FOR IDENTIFYING, TAGGING OUT ANDh LOCKING OUT ALL
AFFECTED CIRCUITS PRIOR TO THE COMMENCEMENT OF
DEMOLITION.
THE ELECTRICAL CONTRACTOR SHALL ALSO BE REQUIRED
TO REMOVE ALL UNUSED CONDUITS;& CONDUCTORS &
PROPERLY SUPPORT ALL EXISTING CONDUITS &
CONDUCTORS THAT WILL REMAIN PRIOR TO THE START
OF NEW WORK. 1
14. ANY DISCREPANCIES BETWEEN DRAWINGS & FIELD
CONDITIONS TO BE REPORTED TO ARCHITECT
IMMEDIATELY.
15, ALL EXISTING CONDITIONS, DIMENSIONS AND MATERIALS
OF CONSTRUCTION ARE TO BE VERIFIED IN THE FIELD
PRIOR TO ANY DEMOLITION WORK OR ANY NEW
CONSTRUCTION.
16. AREAS OF BUILDING NOT PART OF THIS REMODEL TO BE
PROTECTED FROM DUST & DAMAGE DURING REMODEL.
17, ANY MATERIALS INSTALLED ABOVE CEILING DURING
REMODEL SHALL BE NON — COMBUSTIBLE W
ACCORDANCE W/ NFPA 13.
18, THE REMOVAL OF ALL UTILITIES & SYSTEMS SHALL BE TO
THEIR FURTHEST POINT OF ORIGIN,
19. SLAB CUTS TO BE COORDINATED W/ REQUIRED
DISCIPLINES & SUB — CONTRACTORS PRIOR TO
COMMENCEMENT.
20. ALL DEMOLITION WILL BE PERFORMED IN SUCH A
MANNER SO NOT TO BLOCK OR RESTRICT ANY MEANS OF
EGRESS, AS PER FBC 2010, SECTION "1303.3 "MEANS OF
EGRESS ".
21, GENERAL CONTRACTOR TO COORDINATE THE REMOVAL
OF ALL FIXTURES W/ OWNER FOR DESIRED
REMOVAL/SALVAGING/REUSE. 1
SYMBOLS LEGEND
_ I
------ EXISTING TO BE DEMOLISHED
co
T`
J
LL
Q
2
H
O
0
cc)
r
W
rr
H
H
U
Lo
cfj
T
0
r*__
L J
N
n
V
z
r'j ` , %` ✓rj EXISTING WALL cf)
EXISTING COLUMN
L.1
r
r^
/X I
N0. DATE BY DESCRIPTION CONST.
III; REVISIONS
THE ABOVE DRAWINGS, IDEAS AND DESIGNS AREITHE PROPERTY OF DEMANDT
- ARCHITECTURE, PA NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OTHER THAN THE SPEC'.,FIC PROJECT FOR
WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECTS. ... -..
DEMANDIT
=f G TECTURE, P.A. DEMOLITION
F F tg ` - W 129 TERRACE FLOOR PLAN &
;7 *•' "'" • Ili,: FLORIDA 3 317 6 REFLECTED
l� s• 0 � "w-'� 6 5 - 5 2 5 ID
�•�° 4 CEILING PLAN
6001297
F'I;�A MANDT AR -11127
CE RTIFY THAT THIS PLAN AND
SPEGIACATION WAS PREPARED BY ME OR DATE: 03 -02 -12
Rtoll F 7GNb MY DIRECT SUPERVISION AND THAT J G A-0.4
P. AA DULY REGISTERED ARCHITECT DRAWN BY:
"•e�R:s�UNDERE LAWS OF THE STATE OF FLORIDA,
a
F.D.
A5 "SIGNIFIED BY MY HAND AND SEAL REVIEWED BY:
✓ 1 'r
/ _
EXIST STOREFRONT TO BE REM VED
FOR EW PAIR OF STOREFRO DOORS.
SEE SHEET A1.4 FOR NEW DOORS.
NOTE:
IF POSSIBLE EXISTING STOREFRONT TO BE
RE —USED
EXIST. STOREFRONT ELE/ATION
O[� 2 DEMOLITION
A -0.4 =
� SCALE: 1 /4 - T-0"
f
�/ '' ,',j�.,fV,�✓,j`f ,,.EXIST,, .
EXIST. 7 /PANEL B 1A
STAIR NO 2
EXIST.
PANEL `
PANEL B -1 B
HALLWAY
j ✓r,; f j' ( t t EXIST.
f✓ j j, f F fj j r I ICLOSETt t EXIST.
j '% .M EN S TOILET
F= {
s
15 II E ii
LL ER LINE
� t
j f 1 t EXIST.
BREAK ROOM i
i' j ' -
r r t
j
L - - - -w. E_ - - ,
--------- ---
_ -#1-
tL
s
�
F i
--------------
X,
' 21'-10"
ABANDONED jj1
HSBC BANK
20
NO WORK IN THIS
f' j AREA
l ;fir. ,,`j' fff�f rr'� ✓""• `,` I (
EXIST.
r
/0>X I PLATFORM
r I I I EXIST.
;rj" tI WAITING
EXIST. f
ATM ROOM
FLOOR DEMOLITION
V-10"
23
A -0.5
2
21
D. W
// , j �,j r' /, ,✓ /�
rrrj ,,
HAND & STONE !j
MASSAGE & FACIAL
SPA
X j
NO WORK IN THIS
AREA
,' � � rfr ,✓' ✓ � r�,,�
GENERAL NOTES
1, GENERAL CONTRACTOR TO VISIT SITE & FAMILIARIZE
THEMSELVES WITH ALL EXISTING & PROPOSED
CONDITIONS OF PROJECT PRIOR TO COMMENCEMENT OF
ANY WORK.
2, GENERAL CONTRACTOR SHALL FURNISH LABOR &
EQUIPMENT TO DISCONNECT, DISMANTLE, REMOVE &
SALVAGE IN THE DISPOSITION OF THE DEMOLITION
INDICATED ON THESE PLANS.
3. GENERAL CONTRACTOR SHALL TAKE ALL NECESSARY
PRECAUTIONS TO PREVENT DAMAGE TO EXISTING
STRUTURE & EQUIPMENT TO REMAIN & SHALL BE FULLY
RESPONSIBLE FOR ANY DAMAGE TO EXISTING STRUCTURE
OR EQUIPMENT CAUSED BY THE OPERATION.
4, UPON COMPLETION OF THE DEMOLITION, THE ENTIRE
AREA SHALL BE CLEANED OF ALL DEBRIS AND PREPARED
FOR THE PROPOSED CONSTRUCTION
5. EXISTING CONDITIONS NOT SHOWN ON THE
DEMOLITION/EXISTING PLAN DRAWINGS SHALL BE
REMOVED & REWORKED TO CONFORM TO THE PROPOSED
PLANS AS REQUIRED.
6. GENERAL CONTRACTOR IS RESPONSIBLE FOR THE
PROVISIONS OF BARRICADES & ALL OTHER SAFETY
EQUIPMENT AS REQUIRED B THE CONDITIONS OF THE
PROJECT SITE.
7. WHEN AN ITEM OR CONSTRUCTION ELEMENT IS NOTED TO
BE REMOVED, ALL ACCESSORIES, EQUIPMENT, PLUMBING
& ELECTRICAL CONNECTIONS, FLASHINGS, SIGNS
FRAMING &ALL ASSOCIATED CONNECTING ITEMS, ETC.
SHALL BE REMOVED ALONG WITH IT. I THE EXISTING
CONSTRUCTION, WHICH SHALL REMAAN, SHALL BE LEFT
FREE OF THESE ITEMS & ANY OTHER LOSE
CONSTRUCTION & SHALL BE READY TO RECIEVE NEW
WORK, PATCHED & REPAIRED TO MATCH EXISTING &/OR
ADJOINING AREA.
S. GENERAL CONTRACTOR SHALL CONTACT & REQUEST
FROM ANY &ALL UTILITY COMPANIES AS MAY BE
REQUIRED, SURVEYS LOCATING EXISING CONDITIONS OF
THE PROJECT SITE.
9. GENERAL CONTRACTOR SHALL INFORM & COORDINATE
W/ BUILDING MANAGEMENT LOCATION OF DUMPSTERS,
ETC. SO AS NOT TO DISRUPT OTHER TENANTS.
10. GENERAL CONTRACTOR TO NOTIFY ARCHITECT/ENGINEER
IMMEDIATELY WHEN ANY DISCREPANCIES ARISE,
11. UPON REMOVAL OF ALL FINISHES & EXPOSURE OF
STRUCTURE & HIDDEN CONDITIONS, GENERAL
CONTRACTOR TO NOTIFY ARCHITECT] FOR FIELD
INSPECTION BEFORE CONTINUING, UNLESS SO STATED BY
THE ARCHITECT.
12, ANY FIRE EXTINGUISHERS MOVED DURING CONSTRUCTION
ARE TO BE RELOCATED AT AN ADJACENT AREA AS PER
NFPA REQUIREMENTS,
13, THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE
FOR IDENTIFYING, TAGGING OUT ANDh LOCKING OUT ALL
AFFECTED CIRCUITS PRIOR TO THE COMMENCEMENT OF
DEMOLITION.
THE ELECTRICAL CONTRACTOR SHALL ALSO BE REQUIRED
TO REMOVE ALL UNUSED CONDUITS;& CONDUCTORS &
PROPERLY SUPPORT ALL EXISTING CONDUITS &
CONDUCTORS THAT WILL REMAIN PRIOR TO THE START
OF NEW WORK. 1
14. ANY DISCREPANCIES BETWEEN DRAWINGS & FIELD
CONDITIONS TO BE REPORTED TO ARCHITECT
IMMEDIATELY.
15, ALL EXISTING CONDITIONS, DIMENSIONS AND MATERIALS
OF CONSTRUCTION ARE TO BE VERIFIED IN THE FIELD
PRIOR TO ANY DEMOLITION WORK OR ANY NEW
CONSTRUCTION.
16. AREAS OF BUILDING NOT PART OF THIS REMODEL TO BE
PROTECTED FROM DUST & DAMAGE DURING REMODEL.
17, ANY MATERIALS INSTALLED ABOVE CEILING DURING
REMODEL SHALL BE NON — COMBUSTIBLE W
ACCORDANCE W/ NFPA 13.
18, THE REMOVAL OF ALL UTILITIES & SYSTEMS SHALL BE TO
THEIR FURTHEST POINT OF ORIGIN,
19. SLAB CUTS TO BE COORDINATED W/ REQUIRED
DISCIPLINES & SUB — CONTRACTORS PRIOR TO
COMMENCEMENT.
20. ALL DEMOLITION WILL BE PERFORMED IN SUCH A
MANNER SO NOT TO BLOCK OR RESTRICT ANY MEANS OF
EGRESS, AS PER FBC 2010, SECTION "1303.3 "MEANS OF
EGRESS ".
21, GENERAL CONTRACTOR TO COORDINATE THE REMOVAL
OF ALL FIXTURES W/ OWNER FOR DESIRED
REMOVAL/SALVAGING/REUSE. 1
SYMBOLS LEGEND
_ I
------ EXISTING TO BE DEMOLISHED
co
T`
J
LL
Q
2
H
O
0
cc)
r
W
rr
H
H
U
Lo
cfj
T
0
r*__
L J
N
n
V
z
r'j ` , %` ✓rj EXISTING WALL cf)
EXISTING COLUMN
L.1
r
r^
/X I
N0. DATE BY DESCRIPTION CONST.
III; REVISIONS
THE ABOVE DRAWINGS, IDEAS AND DESIGNS AREITHE PROPERTY OF DEMANDT
- ARCHITECTURE, PA NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OTHER THAN THE SPEC'.,FIC PROJECT FOR
WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECTS. ... -..
DEMANDIT
=f G TECTURE, P.A. DEMOLITION
F F tg ` - W 129 TERRACE FLOOR PLAN &
;7 *•' "'" • Ili,: FLORIDA 3 317 6 REFLECTED
l� s• 0 � "w-'� 6 5 - 5 2 5 ID
�•�° 4 CEILING PLAN
6001297
F'I;�A MANDT AR -11127
CE RTIFY THAT THIS PLAN AND
SPEGIACATION WAS PREPARED BY ME OR DATE: 03 -02 -12
Rtoll F 7GNb MY DIRECT SUPERVISION AND THAT J G A-0.4
P. AA DULY REGISTERED ARCHITECT DRAWN BY:
"•e�R:s�UNDERE LAWS OF THE STATE OF FLORIDA,
a
F.D.