12-249-009
M owl GENERAL 'HVAC NOTES I THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL. AND EQUIPMENT FOR A COMPLETE HVAC SYSTEM IN ACCORDANCE WITH THESE DRAWINGS THE FLORIDA BUILDING CODE 2007 AND THE LATEST EDITION OF THE FOLLOWING PUBLICATIONS (A) ANS B91 MECHANICAL REFRIGERATION (B) NFPA PAMPHLETS 90A & 91 (C) SMACNA (D) ASHRAE 2 ALL AIR CONDITIONING DUCTWORK SHALL BE 1 -V2 ' STANDARD DUTY FOIL REINFORCED FIBERGLASS (R-6) MANUFACTURED LOGO PRINTED ON THE VAPOR BARRIER WHEN IN UNCONDITIONED SPACE, AND 3/4 ' STANDARD DUTY FOIL REINFORCED FIBERGLASS (R-4) MANUFACTURED LOGO PRINTED ON THE VAPOR BARRIER IN CONDITIONED SPACE OR RETURN PLENUM SPACE 3. ALL EXHAUST DUCTWORK SHALL BE CODE GAGE GALVANIZED SHEET METAL A DUCT SIZE SHOWN ARE NET FREE AREA INSIDE S ALL AIR DEVICES (DIFFUSERS, REGISTERS AND GRILLES) SHALL BE ALL ALUMINUM CONSTRUCTK K NTH EXPOSED SURFACE CHEMICALLY TREATED TO RECEIVE PAINT TO MATCH COLOR OR AIR GUIDE OR APPROVED EQUAL & PROVIDE OPPOSED BLADE DAMPERS AT ALL DIFFUSERS AND REGISTERS 7. THERMOSTATS SHALL BE COMBINATION COOLING / HEATING WITH SYSTEM COOL / AUTO / HEAT / OFF AND FAN ON / AUTO SELECTOR SWITCHES a REFRIGERANT PIPING SHALL BE COPPER TYPE 1! WITH V2" ARC INSULATION SHALL BE PROVIDED FOR SUCTION LINES 9 PROVIDE NEW FILTERS FOR FAN COIL BEFORE STARTING. THESE FILTERS MUST ALSO BE REPLACED PRIOR TO FINAL ACCEPTANCE BY OWNER 1Q GENERAL CONTRACTOR IS TO HIRE AN INDEPENDENT TEST AND BALANCE COMPANY WHICH SHALL PROVIDE 3 SET OF THE REPORT SIGN AND SEALED BY THE PROFESSIONAL ENGINEER FROM THE COMPANY PRIOR OF ACCEPTANCE OF WORK 'n MECHANICAL CONTRACTOR IS TO PROVIDE TURNING VANE AT ALL CHANGE OF DIRECTIONS OR TO PROVIDE TURNING RADIO, ALL OUTLETS SHALL HAVE EXTRACTORS OR SCUPPERS, AND SHALL BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE REGULATIONS. 12 FLEXIBLE DUCT INSTALLATION AND SUPPORTS TO BE PROVIDED IN ACCORDANCE WITH 2007 FBC-M SEC 603,56.6 13. FLEXIBLE AND RIGID DUCT RUNS SHALL BE FIELD ADJUSTED TO ENSURE INDIVIDUAL FLEX DUCT LENGTHS DO NOT EXCEED A MAXIMUM OF W MEASURED FROM RIGID DUCT TAKEOFFS TO DIFFUSEER CONNECTIONS CONTACT ENGINEER ON RECORD PRIOR TO TO ANY VARIANCES IN RIGID DUCT ROUTING MECHANICAL LEGEND AS PER FBC-M /1 TABLE 4M OUTDOOR • CALCULATIONS CEILING GRILLE SEE SIZE SCHEDULE OAL OUTSIDE AIR INTAKE SALON DUCT TO MATCH NECK SIZE TYPICAL 80 LOCATION CEILING FAN TYPE 9LR SIDE REGISTER ' RETURN AIR GRILL CD CEILING DIFFUSER -E-33J VOLUME DAMPER CG CEILING GRILL s© 48 LD LINEAR DIFFUSER FAN SPEED RPM THERMOSTAT U.O.NL UNLESS OTHERWISE NOTED. — J-� -- RETURN OR EXHAUST, SEE PLANS RTU ROOF TOP UNIT BACKDRAFT DAMPER AHU AIR HANDLER UNIT ELECTRICAL SERVICE AVAILABLE WALL MOUNTED SIDE REGISTER CU CONDENSING UNIT YES DESIGN MANUFACTURER EF EXHAUST FAN EF EXHAUST FAN CFM CUBIC FEET PER MINUTE TF. THERMORN SD DUCT SMOKE DETECTOR U.C. UNDERCUT OF UNDERFLOOR TAG TRANSFER AIR GRILLE AS PER FBC-M /1 TABLE 4M OUTDOOR • CALCULATIONS UNIT DESIGNATION EF -1 AREA SERVED SALON OPERATING WEIGHT LBS. 80 LOCATION CEILING FAN TYPE INUNE CONDENSER TOTAL AIR CFM 450 OBS OR SEER DRIVE TYPE BELT PHASES FAN WHEEL TYPE CENTRIFUGAL s© 48 WPM 230 FAN SPEED RPM VENTILATION FAN SCHEDULE UNIT DESIGNATION EF -1 AREA SERVED SALON OPERATING WEIGHT LBS. 80 LOCATION CEILING FAN TYPE INUNE CONDENSER TOTAL AIR CFM 450 OBS OR SEER DRIVE TYPE BELT PHASES FAN WHEEL TYPE CENTRIFUGAL • r 48 WPM 230 FAN SPEED RPM 2650 a TOTAL STATIC PRESSURE, IN. OF H2O 2.0 16 MOTOR HP 3/4 BACKDRAFT DAMPER YES ELECTRICAL SERVICE AVAILABLE 208 -1 -60 CONNECTED TO EMERGENCY POWER YES DESIGN MANUFACTURER GREENHECK MODEL NUMBER BSQ -80 -7 AIR HANDLING UNIT MBTUH DUCT SMOKE DETECTOR ELECTRICAL- DATA ELECTRICAL DATA r• - _ SMOKE DAMPER(S)-© CONDENSER - M-oll• -© REF UNIT OBS OR SEER AREA SERVED VOLTS PHASES _ •__ _© • r 48 WPM 230 1 25 40 AIR HANDLING UNIT MBTUH TEMP' ENT ELECTRICAL- DATA ELECTRICAL DATA - _ '�Wi�Yii�71•iii���liEirii�® CONDENSER MANUFAC REF UNIT OBS OR SEER AREA SERVED VOLTS PHASES WIRE AMPS ` • r 48 WPM 230 1 25 40 TRANE 4TTR5048E1 16 AS SHOWN E .2 wI I, Y{V I vl , , v v l ]V V IvL- ,VIV I VnIGGLJ rri -ori tvn utwrcno rvn tmt.., 9 Pjiu CONDENSING UNIT MBTUH TEMP' ENT ELECTRICAL- DATA CONDENSER MANUFAC REF UNIT OBS OR SEER AREA SERVED VOLTS PHASES WIRE AMPS FUSES CU-1 CU-2 48 95 230 1 25 40 TRANE 4TTR5048E1 16 AS SHOWN Piia %w]m, . r • • KEY PLAN NOT TO SCALE 1 PROPOSED FLOOR PLAN - MECHANICAL Op E -1.1 SCALE: 1/4" = V -0" OLD CA #9088 1 \ r Maqueira Engineering Consultants, Inc. 7487 SW 50th Terrace Miami, Florida 33155 Tel: 305.669.5595 tolando Maqueira, PE 55482 1 J LL Q I O • III E-41 nf0 � 1 14/02/20121 JO I UPDATED ARCH, M.E.P, DRAWINGS I .� N0, I DATE I BY I DESCRIPTION CONST. REVISIONS ` ABOVE DRAWINGS, IDEAS AND DESK.'NS ARE ;THE PROPERTY OF DEMANDT Wffi5iURE. PA. NO PART THEREOF SHALL BE COPIED. DISCLOSED TO OTHERS OR M IN CONNECTION WITH ANY WORK OTHER THAN THE SPECIFIC PROJECT FOR CH THEY HAVE BM PREPARED WrtTH W THE WRITTEN CONSENT OF THE ARCHITECTS, )EMANDT RCHITECTURE, PA, .,.�$6 SW 129 TERRACE MECHA CAL MIAMI, FLORIDA 33176 305- 665 -5250 PLAN A A C 2 6 0 0 1 2 9 7 . FRANK DEMANDT AR- 11127;` 1 HEREBY CERTIFY THAT THIS PLAN AND SPEaFrATn)N WAS PREPARED BY ME OR - DATE: 03 -02 -12 UNDER D DIRE EGISTER ARCHI ECTT G.c. DRAWN BY: M-1.2 UNDER THE LAWS OF THE STATE OF FLORIDA, . i AS SIGNIFIED BY MY HAND AND SEAL REVIEWED BY: R.M.