Loading...
12-249-008F: "' SCALE: 1-1 /2" = T-0" EXIST. CONC. FLOOR SLAB ACOUSTICAL SEALANT (TOP & BOTTOM) CHANNEL SHAPED RUNNER. MIN. 20 GA. MSG CORROSION PROTECTED STEEL, MIN. WIDTH TO ACOMODATE STEEL STUD SIZE W/ MIN. VLONG LEGS, ATTACHED TO STRUCTURE W/ FASTENERS 9 24'0.C_ MAX. 2 X 2 LAY-IN ACOUSTICAL TILE CEILING. REFER TO REFLECTED CEILING PLAN SHT. A1.2. CONT. 6'x 20 GA. METAL TRACK WWI 0 • ILIFAllop-i CONT. FIRE BLOCKING @ 81-01 A.F.F. TYP. 6"x 20 GA. MTL. STUDS 9 24' O.C. MAX. (1) LAYER 5/8" GYP. BOARD. CHANNEL SHAPED RUNNER. MIN. 20 GA. MSG CORROSION PROTECTED STEEL, MIN. WIDTH TO ACCOMODATE STEEL STUD SIZE W1 MIN. VLONG LEGS, ATTACHED TO STRUCTURE W/ FASTENERS @ 24" O.C. MAX. 4" COVE TILE BASE TILE FLOORING BY OWNER EXIST. CONC. FLOOR SLAB ABOVE CONT. 3-5/8"x 20 GA. METAL TRACK " 2 X 2 LAY-IN ACCOUSTICAL TILE CEILING. ALTERNATE 3-58 REFER TO REFLECTED CEILING PLAN SHT. DIAGONAL BRACING EXIST. ABANDONED @ 24' O.C. A1.2. ATTACHED TO CONC. BOTTOM OF SLAB ABOVE 7777777= ACT CEILING STONE ELEV. +11' -0' cd CONT. 3-5/8'x 20 GA. MASSAGE METAL TRACK 6 CONT. FIRE BLOCKING SOUTH 9 81-0- A.F.F. TYP. in 5/8' GYP. BOARD & FACIAL EXIST. CONC. STRUCTURAL COLUMN 3-5/8' x 20 GA. METAL STUD FRAMING @ 16. O.C. CONT. 20 GA. CORROSION PROTECTED METAL BASE TRACK W/ CONCRETE FASTENERS g 16' O.C. MAX 4" COVE TILE BASE TILE FLOORING - TOP OF FINISH FLOOR SLAB ELEV. 0'-0r BOTTOM OF ACT CEILING ELEV. +10'-0' (MAIN ROOM) EXIST. SCALE: 1-1/2" = l'-O" TOP OF FINISH FLOOR SLAB ELEV. 0'-0' CO YT. 3-5/8"x 20 GA. 7X2 AL TRACK 2 � LAY-IN ACCOUSTICAL TILE CEILING. REFER TO REFLECTED CEILING PLAN SHT. A1.2. ip BOTTOM OF ACT CEILING ELEV. +8'-0' CONT. 3-5/8' x 20 GA. ( +10 -0" g METAL TRACK MAIN ROOM) CONT. FIRE BLOCKING 9 & -0" A.F.F. TYP. 7— 5/8" GYP. BOARD BOTH SIDES 3-5/8" x 20 GA. METAL STUD FRAMING g 16. O.C. MINERAL WOOL OR GLASS FIBER BATTING. CONT. 20 GA. CORROSION PROTECTED METAL BASE TRACK W/ CONCRETE FASTENERS @ 16- O.C. MAX. 4" COVE TILE BASE BOTH SIDES EXIST. CONC. FLOOR SLAB TILE FLOORING-\ A 91FMA 3 U IN go] 0 0 CA N SCALE: 1-1 /2" = l'-O" relo 2x WOOD CAP TOP OF FINISH FLOOR SLAB ELEV. 0'-0' 1/1 6'x1 /2'x5/8'ALUMINUM CHANNEL 5/8" GYP. BOARD @ BOTH SIDES 3-5/8' x 20 GA. METAL STUD FRAMING @ 161 O.C. A MIN. 12THICK OF FIRE HALT SEALANT INSTALLED ON EACH SIDE OF THE WALL BETWEEN THE TOP OF THE GYP. BOARD & THE BOTTOM OF THE CONIC. FLOOR. AS AN OPTION, WHERE PACKING MATERIAL OR FORMING MATERIAL ARE NOT USED, BOND BREAKER TAPE MAY BE APPLIED TO CEILING RUNNER ON EACH SIDE OF WALL & @ TOP & BOTTOM. t MR-UNIM-1011 I. _j m HAND & EXIST. ABANDONED w WAL L EXIST. HOLLOW METAL HSBC BANK LL , STONE MINERAL WOOL OR GLASS cd 0 MASSAGE 6 BATT TO WALLBOARD BASE SOUTH C? in (1) LAYER 5/8- TYPE 'X' GYP. BOARD & FACIAL STAPLE. USE FIVE STAPLES FOR U- 0 � 0 EACH 4 FT. PIECE. DRIVE ONE + I LD STAPLE IN THE CENTER OF EACH SPA 0 -6—Al U- 0 STAGGERED ONE STUD CAVITY ON PAINT CORNER, APPROX. 3" FROM PANT ATTACHED W/ l'TYPE IS, STEEL 0 SCREWS SPACED S' O.C. ALONG EXIST. DEMISING VERTICAL EDGES & 12' IN THE TOILET ROOM FIELD. PARTITION TILE • HANDLE - ADA COMPLIANT LEVER TYPE, TO REMAIN MINERAL WOOL OR CLASS LESS THAN I O�� ACT +81-01 A.F.F. .(R 2 F102FI FIBER BATTING. FASTEN EACH 66 S.F. TILE 4" TILE COVE PAINT PAIN- NT BATT TO WALLBOARD BASE PAINT EXIST. ACT EXIST. +81-01 A.F.F, LAYER W/ A MIN. 9/16" LONG Fl 031 WAXING ROOM STAPLE. USE FIVE STAPLES FOR TILE V COVE TILE PAIN' EACH 4 FT. PIECE. DRIVE ONE PAINT PAINT ACT STAPLE IN THE CENTER OF EACH Fl-04 PIECE & A STAPLE @ EACH 60 S.F� TILE 4" COVE CORNER, APPROX. 3'1 FROM PAINT PAINT PAINT EDGES. EXIST. SCALE: 1-1/2" = l'-O" TOP OF FINISH FLOOR SLAB ELEV. 0'-0' CO YT. 3-5/8"x 20 GA. 7X2 AL TRACK 2 � LAY-IN ACCOUSTICAL TILE CEILING. REFER TO REFLECTED CEILING PLAN SHT. A1.2. ip BOTTOM OF ACT CEILING ELEV. +8'-0' CONT. 3-5/8' x 20 GA. ( +10 -0" g METAL TRACK MAIN ROOM) CONT. FIRE BLOCKING 9 & -0" A.F.F. TYP. 7— 5/8" GYP. BOARD BOTH SIDES 3-5/8" x 20 GA. METAL STUD FRAMING g 16. O.C. MINERAL WOOL OR GLASS FIBER BATTING. CONT. 20 GA. CORROSION PROTECTED METAL BASE TRACK W/ CONCRETE FASTENERS @ 16- O.C. MAX. 4" COVE TILE BASE BOTH SIDES EXIST. CONC. FLOOR SLAB TILE FLOORING-\ A 91FMA 3 U IN go] 0 0 CA N SCALE: 1-1 /2" = l'-O" relo 2x WOOD CAP TOP OF FINISH FLOOR SLAB ELEV. 0'-0' 1/1 6'x1 /2'x5/8'ALUMINUM CHANNEL 5/8" GYP. BOARD @ BOTH SIDES 3-5/8' x 20 GA. METAL STUD FRAMING @ 161 O.C. A MIN. 12THICK OF FIRE HALT SEALANT INSTALLED ON EACH SIDE OF THE WALL BETWEEN THE TOP OF THE GYP. BOARD & THE BOTTOM OF THE CONIC. FLOOR. AS AN OPTION, WHERE PACKING MATERIAL OR FORMING MATERIAL ARE NOT USED, BOND BREAKER TAPE MAY BE APPLIED TO CEILING RUNNER ON EACH SIDE OF WALL & @ TOP & BOTTOM. t MR-UNIM-1011 I. CONT. U.L. APPROVED 1 -HR. FIRE-RATED CAULK SEALANT EACH SIDE (USCG CO. TYPE OR EQUAL) - EXIST. CONC. FLOOR SLAB ABOVE CHANNEL SHAPED RUNNER. MIN. 20 GA. MSG CORROSION PROTECTED STEEL, MIN. WIDTH TO ACCOMODATE STEEL STUD SIZE W/ MIN. l' LONG LEGS, ATTACHED TO STRUCTURE W/ FASTENERS C@ 24" O.C. MAX. 2 X 2 LAY -IN ACOUSTICAL TILE E CEILING. REFER TO REFLECTED CEILING PLAN SHT. A1.2. gQTTOM OF ACT CEILING ELEV. +8'-0' (WAXING ROOM) CONT. 3-5/8" x 20 GA. METAL TRACK CONT. FIRE BLOCKING PINKIES 9 R -0" A.F.F. TYP. NAIL SPA ALL PENETRATIONS TO BE PROTECTED W1 U.L. APPROVED 2-HR. RATED SEALANT/FIH INSTALLED AS PER U.L. DETAIL. (1) LAYER 5/8' TYPE X GYP. BOARD APPLIED VERTICALLY OR HORIZONTALLY. USG CO. TYPE AR, 0, FCV, FRX-G, IP-X2, SCX, SHX, WRIC OR WRX. VERTICAL JOINTS STAGGERED OVER STUDS & STAGGERED ONE STUD CAVITY ON OPPOSITE SIDE OF STUDS, ATTACHED W1 l' TYPE 'S'STEEL SCREWS SPACED 8" O.C. ALONG VERTICAL EDGES & 12" IN THE FIELD. 3 -5/8" MIN. x 20 GA. CORROSION PROTECTED STEEL STUDS W /1 -1/4' LEG & 1/4" RETURN 9 24' O.C. MAX. CUT STUDS 3/8' TO 3/4' LESS THAN ASSEMBLY HEIGHT. CHANNEL SHAPED RUNNER. MIN. 20 GA. MSG CORROSION PROTECTED STEEL, MIN. WIDTH TO ACCOMODATE STEEL STUD SIZE W/ MIN. l' LONG LEGS, ATTACHED TO STRUCTURE W/ FASTENERS @ 24' O.C. MAX. 4" COVE TILE BASE TILE FLOORING BY OWNER --------- I 0465 I r r PARTITION TYPE C 1 -HOUR FIRE RATED PARTITION U.L. DESIGN NO. U465 NON-BEARING WALL RATING - 1 -HR. PARTITION TYPE 'C' SCALE: 1-1 /2" = T-0" TOILET FIXTURE & ACCESSORIES BLOCK DETAILS 3-5/8" METAL STUD FRAMING 9 24' O.C. MAX. VERTICAL STUDS TO BE DOUBLED OR 20 GA. MIN. @ FIXTURES &ACCESSORIES. STUDS TOBE RIGIDLY CONNECTED 9 TOP & BOTTOM RUNNERS 2x6 MIN. BLOCKING 9 TOP OF PLUMBING FIXTURES. BLOCKING TO BE INSERTED BETWEEN VERTICAL STUDS &FASTENED W /(3) 2- SHEETROCK SCREWS @ EACH END. TYP. FOR ENTIRETY OF ITEM. WALL FINISH. REFER TO FLOOR PLAN. 2x4 MIN. BLOCKING g BOTTOM OF PLUMBING FIXTURES (AS REQUIRED) TOP OF BASE CABINETS &COUNTERS. BLOCKING TO BE INSERTED BETWEEN VERTICAL STUDS & FASTENED W1(2) ]2" SHEETROCK SCREWS @ EACH END. TYP.FOR ENTIRET'YOF ITEM. 2x BLOCKING CONC. 20 GA. CORROSION PROTECTED METAL BASE TRACK 9 W/ CONCRETE FASTENERS 6'0 EXHAUST @ 16' O.C. MAX. DUCT 41 COVE TILE BASE @D BOTH SIDES ')e BRACING TILE FLOORING @ 24'0.C. SCALE: 1-1 /2" = 1' -0" 3 -5/8' METAL STUD FRAMING @ 24" O.C. MAX. VERTICAL STUDS TO BE DOUBLED FOR 20 GA. MIN. @ FIXTURES & ACCESSORIES. STUDS TO BE RIGIDLY CONNECTED AT TOP & BOTTOM. TOP OF FINISH FLOOR SLAB ELEV. 0'-0" PROVIDE 12'W. 5/8'CDX BACKING 9 ALL PLUMBING ACCESSORIES BACKING TO BE INSERTED BETWEEN VERTICAL STUDS & FASTENED W/ 2' SHEETROCK SCREWS 9 4' O.C. MAX @ EACH END. TYP FOR ENTIRETY OF ITEM. 2x WOOD CAP 1 /1 6*xl /2"x5/8'ALUMINUM CHANNEL 2-1/2" x 20 GA. METAL STUD FRAMING 161, O.C. CONC. 20 GA. CORROSION PROTECTED METAL BASE TRACK W/ CONCRETE FASTENERS @ 16' O.C. MAX. 4" COVE TILE BASE @ BOTH SIDES 2. PARTITION TYPE lG I A-1.3) SCALE: 1-1/2":-- T-0" A MIN. 1/2" THICK OF FIRE HALT SEALANT INSTALLED ON EACH SIDE OF THE WALL BETWEEN THE TOP OF THE GYP. BOARD &THE BOTTOM OF THE CONC. FLOOR. AS AN OPTION, WHERE PACKING MATERIAL OR FORMING MATERIAL ARE NOT USED, BOND BREAKER TAPE MAY BE APPLIED TO CEILING RUNNER ON EACH SIDE OF WALL& @ TOP & BOTTOM. m (r EXIST. ABANDONED • 3' -0' W. x 6'-B* H. x 1-3/4' WAL L EXIST. HOLLOW METAL HSBC BANK w ci U- MINERAL WOOL OR GLASS +1 0 FIBER BATTING. FASTEN EACH 6 BATT TO WALLBOARD BASE SOUTH +I LAYER W/ W/ A MIN. 9/16' LONG (1) LAYER 5/8- TYPE 'X' GYP. BOARD 0 STAPLE. USE FIVE STAPLES FOR U- 0 � 0 EACH 4 FT. PIECE. DRIVE ONE C, FCV, FRX-G, IP-X2, SCX, SHX, 0 STAPLE IN THE CENTER OF EACH ACCESSIBLE 0 PIECE & A STAPLE @ EACH STAGGERED ONE STUD CAVITY ON PAINT CORNER, APPROX. 3" FROM PANT ATTACHED W/ l'TYPE IS, STEEL EDGES. SCREWS SPACED S' O.C. ALONG CONT. U.L. APPROVED 1 -HR. FIRE-RATED CAULK SEALANT EACH SIDE (USCG CO. TYPE OR EQUAL) - EXIST. CONC. FLOOR SLAB ABOVE CHANNEL SHAPED RUNNER. MIN. 20 GA. MSG CORROSION PROTECTED STEEL, MIN. WIDTH TO ACCOMODATE STEEL STUD SIZE W/ MIN. l' LONG LEGS, ATTACHED TO STRUCTURE W/ FASTENERS C@ 24" O.C. MAX. 2 X 2 LAY -IN ACOUSTICAL TILE E CEILING. REFER TO REFLECTED CEILING PLAN SHT. A1.2. gQTTOM OF ACT CEILING ELEV. +8'-0' (WAXING ROOM) CONT. 3-5/8" x 20 GA. METAL TRACK CONT. FIRE BLOCKING PINKIES 9 R -0" A.F.F. TYP. NAIL SPA ALL PENETRATIONS TO BE PROTECTED W1 U.L. APPROVED 2-HR. RATED SEALANT/FIH INSTALLED AS PER U.L. DETAIL. (1) LAYER 5/8' TYPE X GYP. BOARD APPLIED VERTICALLY OR HORIZONTALLY. USG CO. TYPE AR, 0, FCV, FRX-G, IP-X2, SCX, SHX, WRIC OR WRX. VERTICAL JOINTS STAGGERED OVER STUDS & STAGGERED ONE STUD CAVITY ON OPPOSITE SIDE OF STUDS, ATTACHED W1 l' TYPE 'S'STEEL SCREWS SPACED 8" O.C. ALONG VERTICAL EDGES & 12" IN THE FIELD. 3 -5/8" MIN. x 20 GA. CORROSION PROTECTED STEEL STUDS W /1 -1/4' LEG & 1/4" RETURN 9 24' O.C. MAX. CUT STUDS 3/8' TO 3/4' LESS THAN ASSEMBLY HEIGHT. CHANNEL SHAPED RUNNER. MIN. 20 GA. MSG CORROSION PROTECTED STEEL, MIN. WIDTH TO ACCOMODATE STEEL STUD SIZE W/ MIN. l' LONG LEGS, ATTACHED TO STRUCTURE W/ FASTENERS @ 24' O.C. MAX. 4" COVE TILE BASE TILE FLOORING BY OWNER --------- I 0465 I r r PARTITION TYPE C 1 -HOUR FIRE RATED PARTITION U.L. DESIGN NO. U465 NON-BEARING WALL RATING - 1 -HR. PARTITION TYPE 'C' SCALE: 1-1 /2" = T-0" TOILET FIXTURE & ACCESSORIES BLOCK DETAILS 3-5/8" METAL STUD FRAMING 9 24' O.C. MAX. VERTICAL STUDS TO BE DOUBLED OR 20 GA. MIN. @ FIXTURES &ACCESSORIES. STUDS TOBE RIGIDLY CONNECTED 9 TOP & BOTTOM RUNNERS 2x6 MIN. BLOCKING 9 TOP OF PLUMBING FIXTURES. BLOCKING TO BE INSERTED BETWEEN VERTICAL STUDS &FASTENED W /(3) 2- SHEETROCK SCREWS @ EACH END. TYP. FOR ENTIRETY OF ITEM. WALL FINISH. REFER TO FLOOR PLAN. 2x4 MIN. BLOCKING g BOTTOM OF PLUMBING FIXTURES (AS REQUIRED) TOP OF BASE CABINETS &COUNTERS. BLOCKING TO BE INSERTED BETWEEN VERTICAL STUDS & FASTENED W1(2) ]2" SHEETROCK SCREWS @ EACH END. TYP.FOR ENTIRET'YOF ITEM. 2x BLOCKING CONC. 20 GA. CORROSION PROTECTED METAL BASE TRACK 9 W/ CONCRETE FASTENERS 6'0 EXHAUST @ 16' O.C. MAX. DUCT 41 COVE TILE BASE @D BOTH SIDES ')e BRACING TILE FLOORING @ 24'0.C. SCALE: 1-1 /2" = 1' -0" 3 -5/8' METAL STUD FRAMING @ 24" O.C. MAX. VERTICAL STUDS TO BE DOUBLED FOR 20 GA. MIN. @ FIXTURES & ACCESSORIES. STUDS TO BE RIGIDLY CONNECTED AT TOP & BOTTOM. TOP OF FINISH FLOOR SLAB ELEV. 0'-0" PROVIDE 12'W. 5/8'CDX BACKING 9 ALL PLUMBING ACCESSORIES BACKING TO BE INSERTED BETWEEN VERTICAL STUDS & FASTENED W/ 2' SHEETROCK SCREWS 9 4' O.C. MAX @ EACH END. TYP FOR ENTIRETY OF ITEM. 2x WOOD CAP 1 /1 6*xl /2"x5/8'ALUMINUM CHANNEL 2-1/2" x 20 GA. METAL STUD FRAMING 161, O.C. CONC. 20 GA. CORROSION PROTECTED METAL BASE TRACK W/ CONCRETE FASTENERS @ 16' O.C. MAX. 4" COVE TILE BASE @ BOTH SIDES 2. PARTITION TYPE lG I A-1.3) SCALE: 1-1/2":-- T-0" A MIN. 1/2" THICK OF FIRE HALT SEALANT INSTALLED ON EACH SIDE OF THE WALL BETWEEN THE TOP OF THE GYP. BOARD &THE BOTTOM OF THE CONC. FLOOR. AS AN OPTION, WHERE PACKING MATERIAL OR FORMING MATERIAL ARE NOT USED, BOND BREAKER TAPE MAY BE APPLIED TO CEILING RUNNER ON EACH SIDE OF WALL& @ TOP & BOTTOM. CONT. U.L. APPROVED 1 -HR. FIRE -RATED CAULK SEALANT EACH SIDE (USCG CO. TYPE OR EQUAL) - 0465 6' NOTE: PARTITION TYPE 0 SEE PARTITION TYPE C 1 -HOUR FIRE RATED PARTITION FOR TYP. NOTES. U.L. DESIGN NO. 0465 NON-BEARING WALL RATING - 1 -HR. PARTITION TYPE Dl �A-1 -3) SCALE: 1-1 /2" = 1' -0" EXIST. CONC. FLOOR SLAB ABOVE ACOUSTICAL SEALANT (TOP & BOTTOM) CHANNEL SHAPED RUNNER. MIN. 20 GA. MSG CORROSION PROTECTED STEEL, MIN. WIDTH TO ACCOMODATE STEEL STUD SIZE W/ MIN. l' LONG LEGS, ATTACHED TO STRUCTURE W1 FASTENERS @ 24' O.C. MAX. 2 X 2 LAY-IN ACOUSTICAL TILE CEILING. REFER TO REFLECTED CEILING PLAN SHT. A1.2. BOTTOM OF ACT CEILING ELEV. +10'-0" CONT. 6'x 20 GA. (MAIN ROOM) METAL TRACK CONT. FIRE BLOCKING @ 8'-0' A.F.F. TYP. 6"x 20 GA. MTL. STUDS g 24'0.C. MAX. (1) LAYER 5/8' GYP. BOARD. PARTITION NOTE: AS PER FBC 2010, BUILDING, SECTION 1607.1, INTERIOR PARTITIONS THAT EXCEED & IN HEIGHT SHALL HAVE ADEQUATE STRENGTH TO RESIST A HORIZONTAL LOAD OF NOT LESS THAN 5 P.S.F. CHANNEL SHAPED RUNNER. MIN. 20 GA. MSG CORROSION PROTECTED STEEL, MIN. WIDTH TO ACCOMODATE STEEL STUD SIZE W/ MIN. l' LONG LEGS, ATTACHED TO STRUCTURE W/ FASTENERS @ 24' O.C. MAX. 4' COVE TILE BASE TILE FLOORING d 0 TOP OF FINISH BY OWNER FLOOR SLAB ELEV. 0'-0' R O O M F I N I S H S C H E D U L E (r EXIST. ABANDONED • 3' -0' W. x 6'-B* H. x 1-3/4' WAL L EXIST. HOLLOW METAL HSBC BANK w NO. U- AREA am BASE CEILING CID -1 SOUTH +I T (1) LAYER 5/8- TYPE 'X' GYP. BOARD xw APPLIED VERTICALLY OR U- 0 HORIZONTALLY. USG CO. TYPE AR, 2 C, FCV, FRX-G, IP-X2, SCX, SHX, 0 WRO OR WRX. VERTICAL JOINTS ACCESSIBLE STAGGERED OVER STUDS & 0 STAGGERED ONE STUD CAVITY ON PAINT OPPOSITE SIDE OF STUDS, PANT ATTACHED W/ l'TYPE IS, STEEL EXIST. SCREWS SPACED S' O.C. ALONG VERTICAL EDGES & 12' IN THE TOILET ROOM FIELD. CONT. U.L. APPROVED 1 -HR. FIRE -RATED CAULK SEALANT EACH SIDE (USCG CO. TYPE OR EQUAL) - 0465 6' NOTE: PARTITION TYPE 0 SEE PARTITION TYPE C 1 -HOUR FIRE RATED PARTITION FOR TYP. NOTES. U.L. DESIGN NO. 0465 NON-BEARING WALL RATING - 1 -HR. PARTITION TYPE Dl �A-1 -3) SCALE: 1-1 /2" = 1' -0" EXIST. CONC. FLOOR SLAB ABOVE ACOUSTICAL SEALANT (TOP & BOTTOM) CHANNEL SHAPED RUNNER. MIN. 20 GA. MSG CORROSION PROTECTED STEEL, MIN. WIDTH TO ACCOMODATE STEEL STUD SIZE W/ MIN. l' LONG LEGS, ATTACHED TO STRUCTURE W1 FASTENERS @ 24' O.C. MAX. 2 X 2 LAY-IN ACOUSTICAL TILE CEILING. REFER TO REFLECTED CEILING PLAN SHT. A1.2. BOTTOM OF ACT CEILING ELEV. +10'-0" CONT. 6'x 20 GA. (MAIN ROOM) METAL TRACK CONT. FIRE BLOCKING @ 8'-0' A.F.F. TYP. 6"x 20 GA. MTL. STUDS g 24'0.C. MAX. (1) LAYER 5/8' GYP. BOARD. PARTITION NOTE: AS PER FBC 2010, BUILDING, SECTION 1607.1, INTERIOR PARTITIONS THAT EXCEED & IN HEIGHT SHALL HAVE ADEQUATE STRENGTH TO RESIST A HORIZONTAL LOAD OF NOT LESS THAN 5 P.S.F. CHANNEL SHAPED RUNNER. MIN. 20 GA. MSG CORROSION PROTECTED STEEL, MIN. WIDTH TO ACCOMODATE STEEL STUD SIZE W/ MIN. l' LONG LEGS, ATTACHED TO STRUCTURE W/ FASTENERS @ 24' O.C. MAX. 4' COVE TILE BASE TILE FLOORING d 0 TOP OF FINISH BY OWNER FLOOR SLAB ELEV. 0'-0' R O O M F I N I S H S C H E D U L E • 3'-0* W. X 6-8" H. X 1 3/4" • 3' -0' W. x 6'-B* H. x 1-3/4' WAL L EXIST. HOLLOW METAL CEIUNG SOLID CORE WOOD NO. ROOM NAME AREA FLOOR BASE CEILING NOTES NORTH SOUTH EAST WEST FRAM - WITH F.B.G. 2007, CHAPTER 11, HEIGHT r-10-1 ACCESSIBLE 75 S.F. EXIST. TILE EXIST. PAINT PAINT PANT PAINT EXIST. EXIST. 2007 FFPC 7.2.1.4.1 �7. TOILET ROOM NICKEL FINISH TILE • HANDLE - ADA COMPLIANT LEVER TYPE, LESS THAN I O�� ACT +81-01 A.F.F. .(R 2 F102FI BREAK ROOM 66 S.F. TILE 4" TILE COVE PAINT PAIN- NT PAINT PAINT EXIST. ACT EXIST. +81-01 A.F.F, Fl 031 WAXING ROOM 72 S.F. TILE V COVE TILE PAIN' PAINT PAINT PAINT ACT +&-17' AFF. Fl-04 HALLWAY 60 S.F� TILE 4" COVE PAINT PAINT PAINT PAINT ACT +81-01 TI LE A.F.F. 01-0-5 I MANICURE TABLES 337 S.F. TILE 4'COVE TILE PANT PAINT PAINT PAINT ACT +11-01 A.F.F. 1-0-61 PEDICURE SPA 337 S.F. TILE 4° COVE PAINT PAIN' PAINT PAINT ACT +11-01 CHAIRS TILE 1 A.F.F. F107 1 WAITING AREA 80 S.F. S.F TILE 'COVE PANT PAINT PAINT PANT ACT A-F.F TILE Fl-08-1 RECEPTION 42 S.F. TILE 4* COVE PAINT PAINT PAINT PAINT ACT +11-01 A.F.F. TILE Fl-0-9-1 NAIL DRYING TABLES 80 S.F. TILE COVE TILE PAINT PAIN' PAIN' PAINT ACT +11-01 A.F,F. I NOTES: 1. FINISH TYPES & COLORS TO BE OWNER SELECTED. 2. GENERAL CONTRACTOR TO PROVED PLYWOOD WOT 2x BLOCKING FOR ALL ACCESSORIES & FIXTURES. REFER TO BLOCKING DETAILS ON THIS SHEET. 3. TOILET ROOM LAYOUT & ACCESSORIES AS PER F.B.C. 2010, CHARTER 11. 4. CONTRACTOR TO SUBMIT SHOP DRAWINGS TO ARCHITECT FOR REVIEW FOR ALL NEW EQUIPMENT & FIXTURES PRIOR TO PURCHASING. 5. CONTRACTOR TO FIELD VERIFY ALL CLEARANCES FOR ADA COMPLIANCE. 'v_ M wws= DT* *I ing V: 9 a 0 EXISTING C17-Y OF SOUTHh'i IA &q BUILDING DEPT. STRUCTUR4L SECTION �; no= ............ co • 0 0 W F_ co rO Lo 0 Lo N CL ■ • 3'-0* W. X 6-8" H. X 1 3/4" • 3' -0' W. x 6'-B* H. x 1-3/4' EXIST. HOLLOW METAL SOLID CORE WOOD • FRAME - HOLLOW METAL TO BE PAINTED • HORIZONTAL SLIDING EXIST. SELF-CLOSER. SATIN NICKEL TO CO )LY COMPLY DOOR TO BE PAINTED FRAM - WITH F.B.G. 2007, CHAPTER 11, SECTIONS 11- 4,13.10 AND HORIZONTAL SLIDING 11-4.13.11. DOOR ALLOWED PER • HINGES - (3) 4� BUTTS, SATIN 2007 FFPC 7.2.1.4.1 �7. NICKEL FINISH ROOM OCCUPANCY • HANDLE - ADA COMPLIANT LEVER TYPE, LESS THAN I O�� SATIN NICKEL .(R 2 1\1 I • PRIVACY LOCK, SATIN NICKEL EXISTING C17-Y OF SOUTHh'i IA &q BUILDING DEPT. STRUCTUR4L SECTION �; no= ............ co • 0 0 W F_ co rO Lo 0 Lo N CL ■ •