12-249-008F: "'
SCALE: 1-1 /2" = T-0"
EXIST. CONC.
FLOOR SLAB
ACOUSTICAL
SEALANT
(TOP & BOTTOM)
CHANNEL SHAPED RUNNER. MIN.
20 GA. MSG CORROSION
PROTECTED STEEL, MIN. WIDTH
TO ACOMODATE STEEL STUD SIZE
W/ MIN. VLONG LEGS, ATTACHED
TO STRUCTURE W/ FASTENERS 9
24'0.C_ MAX.
2 X 2 LAY-IN ACOUSTICAL TILE
CEILING. REFER TO REFLECTED
CEILING PLAN SHT. A1.2.
CONT. 6'x 20 GA.
METAL TRACK
WWI 0 •
ILIFAllop-i
CONT. FIRE BLOCKING
@ 81-01 A.F.F. TYP.
6"x 20 GA. MTL. STUDS
9 24' O.C. MAX.
(1) LAYER 5/8" GYP. BOARD.
CHANNEL SHAPED RUNNER. MIN.
20 GA. MSG CORROSION
PROTECTED STEEL, MIN. WIDTH
TO ACCOMODATE STEEL STUD
SIZE W1 MIN. VLONG LEGS,
ATTACHED TO STRUCTURE W/
FASTENERS @ 24" O.C. MAX.
4" COVE
TILE BASE
TILE FLOORING
BY OWNER
EXIST. CONC.
FLOOR SLAB ABOVE
CONT. 3-5/8"x 20 GA.
METAL TRACK
"
2 X 2 LAY-IN ACCOUSTICAL TILE CEILING.
ALTERNATE 3-58
REFER TO REFLECTED CEILING PLAN SHT.
DIAGONAL BRACING
EXIST. ABANDONED
@ 24' O.C.
A1.2.
ATTACHED TO CONC.
BOTTOM OF
SLAB ABOVE
7777777= ACT CEILING
STONE
ELEV. +11' -0'
cd
CONT. 3-5/8'x 20 GA.
MASSAGE
METAL TRACK
6
CONT. FIRE BLOCKING
SOUTH
9 81-0- A.F.F. TYP.
in
5/8' GYP. BOARD
& FACIAL
EXIST. CONC.
STRUCTURAL COLUMN
3-5/8' x 20 GA.
METAL STUD FRAMING
@ 16. O.C.
CONT. 20 GA. CORROSION
PROTECTED METAL BASE TRACK
W/ CONCRETE FASTENERS
g 16' O.C. MAX
4" COVE TILE BASE
TILE FLOORING -
TOP OF FINISH
FLOOR SLAB
ELEV. 0'-0r
BOTTOM OF
ACT CEILING
ELEV. +10'-0'
(MAIN ROOM)
EXIST.
SCALE: 1-1/2" = l'-O"
TOP OF FINISH
FLOOR SLAB
ELEV. 0'-0'
CO YT. 3-5/8"x 20 GA.
7X2 AL TRACK
2
� LAY-IN ACCOUSTICAL TILE CEILING.
REFER TO REFLECTED CEILING PLAN SHT.
A1.2.
ip
BOTTOM OF
ACT CEILING
ELEV. +8'-0'
CONT. 3-5/8' x 20 GA. ( +10 -0" g
METAL TRACK
MAIN ROOM)
CONT. FIRE BLOCKING
9 & -0" A.F.F. TYP.
7—
5/8" GYP. BOARD
BOTH SIDES
3-5/8" x 20 GA.
METAL STUD FRAMING
g 16. O.C.
MINERAL WOOL OR
GLASS FIBER BATTING.
CONT. 20 GA. CORROSION
PROTECTED METAL BASE TRACK
W/ CONCRETE FASTENERS
@ 16- O.C. MAX.
4" COVE TILE BASE
BOTH SIDES
EXIST. CONC. FLOOR SLAB
TILE FLOORING-\
A
91FMA 3 U IN go] 0 0 CA N
SCALE: 1-1 /2" = l'-O"
relo
2x WOOD CAP
TOP OF FINISH
FLOOR SLAB
ELEV. 0'-0'
1/1 6'x1 /2'x5/8'ALUMINUM
CHANNEL
5/8" GYP. BOARD @
BOTH SIDES
3-5/8' x 20 GA.
METAL STUD FRAMING
@ 161 O.C.
A MIN. 12THICK OF FIRE HALT
SEALANT INSTALLED ON EACH
SIDE OF THE WALL BETWEEN THE
TOP OF THE GYP. BOARD & THE
BOTTOM OF THE CONIC. FLOOR.
AS AN OPTION, WHERE PACKING
MATERIAL OR FORMING MATERIAL
ARE NOT USED, BOND BREAKER
TAPE MAY BE APPLIED TO CEILING
RUNNER ON EACH SIDE OF WALL &
@ TOP & BOTTOM.
t
MR-UNIM-1011
I.
_j
m
HAND &
EXIST. ABANDONED
w
WAL L
EXIST. HOLLOW METAL
HSBC BANK
LL
,
STONE
MINERAL WOOL OR GLASS
cd
0
MASSAGE
6
BATT TO WALLBOARD BASE
SOUTH
C?
in
(1) LAYER 5/8- TYPE 'X' GYP. BOARD
& FACIAL
STAPLE. USE FIVE STAPLES FOR
U-
0
�
0
EACH 4 FT. PIECE. DRIVE ONE
+ I
LD
STAPLE IN THE CENTER OF EACH
SPA
0
-6—Al
U-
0
STAGGERED ONE STUD CAVITY ON
PAINT
CORNER, APPROX. 3" FROM
PANT
ATTACHED W/ l'TYPE IS, STEEL
0
SCREWS SPACED S' O.C. ALONG
EXIST. DEMISING
VERTICAL EDGES & 12' IN THE
TOILET ROOM
FIELD.
PARTITION
TILE
• HANDLE - ADA COMPLIANT LEVER TYPE,
TO REMAIN
MINERAL WOOL OR CLASS
LESS THAN I O��
ACT
+81-01 A.F.F.
.(R
2
F102FI
FIBER BATTING. FASTEN EACH
66 S.F.
TILE
4"
TILE COVE
PAINT
PAIN-
NT
BATT TO WALLBOARD BASE
PAINT
EXIST.
ACT
EXIST.
+81-01 A.F.F,
LAYER W/ A MIN. 9/16" LONG
Fl 031
WAXING ROOM
STAPLE. USE FIVE STAPLES FOR
TILE
V COVE
TILE
PAIN'
EACH 4 FT. PIECE. DRIVE ONE
PAINT
PAINT
ACT
STAPLE IN THE CENTER OF EACH
Fl-04
PIECE & A STAPLE @ EACH
60 S.F�
TILE
4" COVE
CORNER, APPROX. 3'1 FROM
PAINT
PAINT
PAINT
EDGES.
EXIST.
SCALE: 1-1/2" = l'-O"
TOP OF FINISH
FLOOR SLAB
ELEV. 0'-0'
CO YT. 3-5/8"x 20 GA.
7X2 AL TRACK
2
� LAY-IN ACCOUSTICAL TILE CEILING.
REFER TO REFLECTED CEILING PLAN SHT.
A1.2.
ip
BOTTOM OF
ACT CEILING
ELEV. +8'-0'
CONT. 3-5/8' x 20 GA. ( +10 -0" g
METAL TRACK
MAIN ROOM)
CONT. FIRE BLOCKING
9 & -0" A.F.F. TYP.
7—
5/8" GYP. BOARD
BOTH SIDES
3-5/8" x 20 GA.
METAL STUD FRAMING
g 16. O.C.
MINERAL WOOL OR
GLASS FIBER BATTING.
CONT. 20 GA. CORROSION
PROTECTED METAL BASE TRACK
W/ CONCRETE FASTENERS
@ 16- O.C. MAX.
4" COVE TILE BASE
BOTH SIDES
EXIST. CONC. FLOOR SLAB
TILE FLOORING-\
A
91FMA 3 U IN go] 0 0 CA N
SCALE: 1-1 /2" = l'-O"
relo
2x WOOD CAP
TOP OF FINISH
FLOOR SLAB
ELEV. 0'-0'
1/1 6'x1 /2'x5/8'ALUMINUM
CHANNEL
5/8" GYP. BOARD @
BOTH SIDES
3-5/8' x 20 GA.
METAL STUD FRAMING
@ 161 O.C.
A MIN. 12THICK OF FIRE HALT
SEALANT INSTALLED ON EACH
SIDE OF THE WALL BETWEEN THE
TOP OF THE GYP. BOARD & THE
BOTTOM OF THE CONIC. FLOOR.
AS AN OPTION, WHERE PACKING
MATERIAL OR FORMING MATERIAL
ARE NOT USED, BOND BREAKER
TAPE MAY BE APPLIED TO CEILING
RUNNER ON EACH SIDE OF WALL &
@ TOP & BOTTOM.
t
MR-UNIM-1011
I.
CONT. U.L. APPROVED 1 -HR.
FIRE-RATED CAULK SEALANT
EACH SIDE
(USCG CO. TYPE OR EQUAL) -
EXIST. CONC.
FLOOR SLAB ABOVE
CHANNEL SHAPED RUNNER. MIN. 20 GA. MSG
CORROSION PROTECTED STEEL, MIN. WIDTH
TO ACCOMODATE STEEL STUD SIZE W/ MIN. l'
LONG LEGS, ATTACHED TO STRUCTURE W/
FASTENERS C@ 24" O.C. MAX.
2 X 2 LAY -IN ACOUSTICAL TILE
E
CEILING. REFER TO REFLECTED
CEILING PLAN SHT. A1.2. gQTTOM OF
ACT CEILING
ELEV. +8'-0'
(WAXING ROOM)
CONT. 3-5/8" x 20 GA.
METAL TRACK
CONT. FIRE BLOCKING PINKIES
9 R -0" A.F.F. TYP.
NAIL SPA
ALL PENETRATIONS TO BE
PROTECTED W1 U.L. APPROVED
2-HR. RATED SEALANT/FIH
INSTALLED AS PER U.L. DETAIL.
(1) LAYER 5/8' TYPE X GYP. BOARD
APPLIED VERTICALLY OR HORIZONTALLY.
USG CO. TYPE AR, 0, FCV, FRX-G, IP-X2,
SCX, SHX, WRIC OR WRX. VERTICAL
JOINTS STAGGERED OVER STUDS &
STAGGERED ONE STUD CAVITY ON
OPPOSITE SIDE OF STUDS, ATTACHED W1
l' TYPE 'S'STEEL SCREWS SPACED 8" O.C.
ALONG VERTICAL EDGES & 12" IN THE
FIELD.
3 -5/8" MIN. x 20 GA. CORROSION
PROTECTED STEEL STUDS W /1 -1/4' LEG &
1/4" RETURN 9 24' O.C. MAX. CUT STUDS
3/8' TO 3/4' LESS THAN ASSEMBLY
HEIGHT.
CHANNEL SHAPED RUNNER. MIN. 20 GA. MSG
CORROSION PROTECTED STEEL, MIN. WIDTH
TO ACCOMODATE STEEL STUD SIZE W/ MIN. l'
LONG LEGS, ATTACHED TO STRUCTURE W/
FASTENERS @ 24' O.C. MAX.
4" COVE TILE BASE
TILE FLOORING
BY OWNER ---------
I
0465 I
r r
PARTITION TYPE C
1 -HOUR FIRE RATED PARTITION
U.L. DESIGN NO. U465
NON-BEARING WALL RATING - 1 -HR.
PARTITION TYPE 'C'
SCALE: 1-1 /2" = T-0"
TOILET FIXTURE & ACCESSORIES
BLOCK DETAILS
3-5/8" METAL STUD FRAMING 9 24'
O.C. MAX. VERTICAL STUDS TO BE
DOUBLED OR 20 GA. MIN. @ FIXTURES
&ACCESSORIES. STUDS TOBE
RIGIDLY CONNECTED 9 TOP &
BOTTOM RUNNERS
2x6 MIN. BLOCKING 9 TOP OF
PLUMBING FIXTURES. BLOCKING TO
BE INSERTED BETWEEN VERTICAL
STUDS &FASTENED W /(3) 2-
SHEETROCK SCREWS @ EACH END.
TYP. FOR ENTIRETY OF ITEM.
WALL FINISH.
REFER TO FLOOR PLAN.
2x4 MIN. BLOCKING g BOTTOM OF
PLUMBING FIXTURES (AS REQUIRED)
TOP OF BASE CABINETS &COUNTERS.
BLOCKING TO BE INSERTED BETWEEN
VERTICAL STUDS & FASTENED W1(2)
]2" SHEETROCK SCREWS @ EACH END.
TYP.FOR ENTIRET'YOF ITEM.
2x BLOCKING
CONC. 20 GA. CORROSION
PROTECTED METAL BASE TRACK 9
W/ CONCRETE FASTENERS 6'0 EXHAUST
@ 16' O.C. MAX. DUCT
41 COVE TILE BASE @D
BOTH SIDES ')e BRACING
TILE FLOORING @ 24'0.C.
SCALE: 1-1 /2" = 1' -0"
3 -5/8' METAL STUD FRAMING @ 24"
O.C. MAX.
VERTICAL STUDS TO BE DOUBLED
FOR 20 GA. MIN. @ FIXTURES &
ACCESSORIES. STUDS TO BE
RIGIDLY CONNECTED AT TOP &
BOTTOM.
TOP OF FINISH
FLOOR SLAB
ELEV. 0'-0"
PROVIDE 12'W. 5/8'CDX BACKING
9 ALL PLUMBING ACCESSORIES
BACKING TO BE INSERTED BETWEEN
VERTICAL STUDS & FASTENED W/
2' SHEETROCK SCREWS 9 4' O.C.
MAX @ EACH END.
TYP FOR ENTIRETY OF ITEM.
2x WOOD CAP
1 /1 6*xl /2"x5/8'ALUMINUM
CHANNEL
2-1/2" x 20 GA.
METAL STUD FRAMING
161, O.C.
CONC. 20 GA. CORROSION
PROTECTED METAL BASE TRACK
W/ CONCRETE FASTENERS
@ 16' O.C. MAX.
4" COVE TILE BASE @
BOTH SIDES
2.
PARTITION TYPE lG I
A-1.3)
SCALE: 1-1/2":-- T-0"
A MIN. 1/2" THICK OF FIRE HALT
SEALANT INSTALLED ON EACH
SIDE OF THE WALL BETWEEN THE
TOP OF THE GYP. BOARD &THE
BOTTOM OF THE CONC. FLOOR.
AS AN OPTION, WHERE PACKING
MATERIAL OR FORMING MATERIAL
ARE NOT USED, BOND BREAKER
TAPE MAY BE APPLIED TO CEILING
RUNNER ON EACH SIDE OF WALL&
@ TOP & BOTTOM.
m
(r
EXIST. ABANDONED
• 3' -0' W. x 6'-B* H. x 1-3/4'
WAL L
EXIST. HOLLOW METAL
HSBC BANK
w
ci
U-
MINERAL WOOL OR GLASS
+1
0
FIBER BATTING. FASTEN EACH
6
BATT TO WALLBOARD BASE
SOUTH
+I
LAYER W/ W/ A MIN. 9/16' LONG
(1) LAYER 5/8- TYPE 'X' GYP. BOARD
0
STAPLE. USE FIVE STAPLES FOR
U-
0
�
0
EACH 4 FT. PIECE. DRIVE ONE
C, FCV, FRX-G, IP-X2, SCX, SHX,
0
STAPLE IN THE CENTER OF EACH
ACCESSIBLE
0
PIECE & A STAPLE @ EACH
STAGGERED ONE STUD CAVITY ON
PAINT
CORNER, APPROX. 3" FROM
PANT
ATTACHED W/ l'TYPE IS, STEEL
EDGES.
SCREWS SPACED S' O.C. ALONG
CONT. U.L. APPROVED 1 -HR.
FIRE-RATED CAULK SEALANT
EACH SIDE
(USCG CO. TYPE OR EQUAL) -
EXIST. CONC.
FLOOR SLAB ABOVE
CHANNEL SHAPED RUNNER. MIN. 20 GA. MSG
CORROSION PROTECTED STEEL, MIN. WIDTH
TO ACCOMODATE STEEL STUD SIZE W/ MIN. l'
LONG LEGS, ATTACHED TO STRUCTURE W/
FASTENERS C@ 24" O.C. MAX.
2 X 2 LAY -IN ACOUSTICAL TILE
E
CEILING. REFER TO REFLECTED
CEILING PLAN SHT. A1.2. gQTTOM OF
ACT CEILING
ELEV. +8'-0'
(WAXING ROOM)
CONT. 3-5/8" x 20 GA.
METAL TRACK
CONT. FIRE BLOCKING PINKIES
9 R -0" A.F.F. TYP.
NAIL SPA
ALL PENETRATIONS TO BE
PROTECTED W1 U.L. APPROVED
2-HR. RATED SEALANT/FIH
INSTALLED AS PER U.L. DETAIL.
(1) LAYER 5/8' TYPE X GYP. BOARD
APPLIED VERTICALLY OR HORIZONTALLY.
USG CO. TYPE AR, 0, FCV, FRX-G, IP-X2,
SCX, SHX, WRIC OR WRX. VERTICAL
JOINTS STAGGERED OVER STUDS &
STAGGERED ONE STUD CAVITY ON
OPPOSITE SIDE OF STUDS, ATTACHED W1
l' TYPE 'S'STEEL SCREWS SPACED 8" O.C.
ALONG VERTICAL EDGES & 12" IN THE
FIELD.
3 -5/8" MIN. x 20 GA. CORROSION
PROTECTED STEEL STUDS W /1 -1/4' LEG &
1/4" RETURN 9 24' O.C. MAX. CUT STUDS
3/8' TO 3/4' LESS THAN ASSEMBLY
HEIGHT.
CHANNEL SHAPED RUNNER. MIN. 20 GA. MSG
CORROSION PROTECTED STEEL, MIN. WIDTH
TO ACCOMODATE STEEL STUD SIZE W/ MIN. l'
LONG LEGS, ATTACHED TO STRUCTURE W/
FASTENERS @ 24' O.C. MAX.
4" COVE TILE BASE
TILE FLOORING
BY OWNER ---------
I
0465 I
r r
PARTITION TYPE C
1 -HOUR FIRE RATED PARTITION
U.L. DESIGN NO. U465
NON-BEARING WALL RATING - 1 -HR.
PARTITION TYPE 'C'
SCALE: 1-1 /2" = T-0"
TOILET FIXTURE & ACCESSORIES
BLOCK DETAILS
3-5/8" METAL STUD FRAMING 9 24'
O.C. MAX. VERTICAL STUDS TO BE
DOUBLED OR 20 GA. MIN. @ FIXTURES
&ACCESSORIES. STUDS TOBE
RIGIDLY CONNECTED 9 TOP &
BOTTOM RUNNERS
2x6 MIN. BLOCKING 9 TOP OF
PLUMBING FIXTURES. BLOCKING TO
BE INSERTED BETWEEN VERTICAL
STUDS &FASTENED W /(3) 2-
SHEETROCK SCREWS @ EACH END.
TYP. FOR ENTIRETY OF ITEM.
WALL FINISH.
REFER TO FLOOR PLAN.
2x4 MIN. BLOCKING g BOTTOM OF
PLUMBING FIXTURES (AS REQUIRED)
TOP OF BASE CABINETS &COUNTERS.
BLOCKING TO BE INSERTED BETWEEN
VERTICAL STUDS & FASTENED W1(2)
]2" SHEETROCK SCREWS @ EACH END.
TYP.FOR ENTIRET'YOF ITEM.
2x BLOCKING
CONC. 20 GA. CORROSION
PROTECTED METAL BASE TRACK 9
W/ CONCRETE FASTENERS 6'0 EXHAUST
@ 16' O.C. MAX. DUCT
41 COVE TILE BASE @D
BOTH SIDES ')e BRACING
TILE FLOORING @ 24'0.C.
SCALE: 1-1 /2" = 1' -0"
3 -5/8' METAL STUD FRAMING @ 24"
O.C. MAX.
VERTICAL STUDS TO BE DOUBLED
FOR 20 GA. MIN. @ FIXTURES &
ACCESSORIES. STUDS TO BE
RIGIDLY CONNECTED AT TOP &
BOTTOM.
TOP OF FINISH
FLOOR SLAB
ELEV. 0'-0"
PROVIDE 12'W. 5/8'CDX BACKING
9 ALL PLUMBING ACCESSORIES
BACKING TO BE INSERTED BETWEEN
VERTICAL STUDS & FASTENED W/
2' SHEETROCK SCREWS 9 4' O.C.
MAX @ EACH END.
TYP FOR ENTIRETY OF ITEM.
2x WOOD CAP
1 /1 6*xl /2"x5/8'ALUMINUM
CHANNEL
2-1/2" x 20 GA.
METAL STUD FRAMING
161, O.C.
CONC. 20 GA. CORROSION
PROTECTED METAL BASE TRACK
W/ CONCRETE FASTENERS
@ 16' O.C. MAX.
4" COVE TILE BASE @
BOTH SIDES
2.
PARTITION TYPE lG I
A-1.3)
SCALE: 1-1/2":-- T-0"
A MIN. 1/2" THICK OF FIRE HALT
SEALANT INSTALLED ON EACH
SIDE OF THE WALL BETWEEN THE
TOP OF THE GYP. BOARD &THE
BOTTOM OF THE CONC. FLOOR.
AS AN OPTION, WHERE PACKING
MATERIAL OR FORMING MATERIAL
ARE NOT USED, BOND BREAKER
TAPE MAY BE APPLIED TO CEILING
RUNNER ON EACH SIDE OF WALL&
@ TOP & BOTTOM.
CONT. U.L. APPROVED 1 -HR.
FIRE -RATED CAULK SEALANT
EACH SIDE
(USCG CO. TYPE OR EQUAL) -
0465 6'
NOTE: PARTITION TYPE 0
SEE PARTITION TYPE C 1 -HOUR FIRE RATED PARTITION
FOR TYP. NOTES. U.L. DESIGN NO. 0465
NON-BEARING WALL RATING - 1 -HR.
PARTITION TYPE Dl
�A-1 -3) SCALE: 1-1 /2" = 1' -0"
EXIST. CONC.
FLOOR SLAB ABOVE
ACOUSTICAL
SEALANT
(TOP & BOTTOM)
CHANNEL SHAPED RUNNER. MIN. 20 GA. MSG
CORROSION PROTECTED STEEL, MIN. WIDTH
TO ACCOMODATE STEEL STUD SIZE W/ MIN. l'
LONG LEGS, ATTACHED TO STRUCTURE W1
FASTENERS @ 24' O.C. MAX.
2 X 2 LAY-IN ACOUSTICAL TILE
CEILING. REFER TO REFLECTED
CEILING PLAN SHT. A1.2. BOTTOM OF
ACT CEILING
ELEV. +10'-0"
CONT. 6'x 20 GA. (MAIN ROOM)
METAL TRACK
CONT. FIRE BLOCKING
@ 8'-0' A.F.F. TYP.
6"x 20 GA. MTL. STUDS g 24'0.C. MAX.
(1) LAYER 5/8' GYP. BOARD.
PARTITION NOTE:
AS PER FBC 2010, BUILDING, SECTION 1607.1,
INTERIOR PARTITIONS THAT EXCEED & IN
HEIGHT SHALL HAVE ADEQUATE STRENGTH TO
RESIST A HORIZONTAL LOAD OF NOT LESS
THAN 5 P.S.F.
CHANNEL SHAPED RUNNER. MIN. 20 GA. MSG
CORROSION PROTECTED STEEL, MIN. WIDTH
TO ACCOMODATE STEEL STUD SIZE W/ MIN. l'
LONG LEGS, ATTACHED TO STRUCTURE W/
FASTENERS @ 24' O.C. MAX.
4' COVE TILE BASE
TILE FLOORING
d 0 TOP OF FINISH
BY OWNER FLOOR SLAB
ELEV. 0'-0'
R O O M F I N I S H S C H E D U L E
(r
EXIST. ABANDONED
• 3' -0' W. x 6'-B* H. x 1-3/4'
WAL L
EXIST. HOLLOW METAL
HSBC BANK
w
NO.
U-
AREA
am
BASE
CEILING
CID
-1
SOUTH
+I
T
(1) LAYER 5/8- TYPE 'X' GYP. BOARD
xw
APPLIED VERTICALLY OR
U-
0
HORIZONTALLY. USG CO. TYPE AR,
2
C, FCV, FRX-G, IP-X2, SCX, SHX,
0
WRO OR WRX. VERTICAL JOINTS
ACCESSIBLE
STAGGERED OVER STUDS &
0
STAGGERED ONE STUD CAVITY ON
PAINT
OPPOSITE SIDE OF STUDS,
PANT
ATTACHED W/ l'TYPE IS, STEEL
EXIST.
SCREWS SPACED S' O.C. ALONG
VERTICAL EDGES & 12' IN THE
TOILET ROOM
FIELD.
CONT. U.L. APPROVED 1 -HR.
FIRE -RATED CAULK SEALANT
EACH SIDE
(USCG CO. TYPE OR EQUAL) -
0465 6'
NOTE: PARTITION TYPE 0
SEE PARTITION TYPE C 1 -HOUR FIRE RATED PARTITION
FOR TYP. NOTES. U.L. DESIGN NO. 0465
NON-BEARING WALL RATING - 1 -HR.
PARTITION TYPE Dl
�A-1 -3) SCALE: 1-1 /2" = 1' -0"
EXIST. CONC.
FLOOR SLAB ABOVE
ACOUSTICAL
SEALANT
(TOP & BOTTOM)
CHANNEL SHAPED RUNNER. MIN. 20 GA. MSG
CORROSION PROTECTED STEEL, MIN. WIDTH
TO ACCOMODATE STEEL STUD SIZE W/ MIN. l'
LONG LEGS, ATTACHED TO STRUCTURE W1
FASTENERS @ 24' O.C. MAX.
2 X 2 LAY-IN ACOUSTICAL TILE
CEILING. REFER TO REFLECTED
CEILING PLAN SHT. A1.2. BOTTOM OF
ACT CEILING
ELEV. +10'-0"
CONT. 6'x 20 GA. (MAIN ROOM)
METAL TRACK
CONT. FIRE BLOCKING
@ 8'-0' A.F.F. TYP.
6"x 20 GA. MTL. STUDS g 24'0.C. MAX.
(1) LAYER 5/8' GYP. BOARD.
PARTITION NOTE:
AS PER FBC 2010, BUILDING, SECTION 1607.1,
INTERIOR PARTITIONS THAT EXCEED & IN
HEIGHT SHALL HAVE ADEQUATE STRENGTH TO
RESIST A HORIZONTAL LOAD OF NOT LESS
THAN 5 P.S.F.
CHANNEL SHAPED RUNNER. MIN. 20 GA. MSG
CORROSION PROTECTED STEEL, MIN. WIDTH
TO ACCOMODATE STEEL STUD SIZE W/ MIN. l'
LONG LEGS, ATTACHED TO STRUCTURE W/
FASTENERS @ 24' O.C. MAX.
4' COVE TILE BASE
TILE FLOORING
d 0 TOP OF FINISH
BY OWNER FLOOR SLAB
ELEV. 0'-0'
R O O M F I N I S H S C H E D U L E
• 3'-0* W. X 6-8" H. X 1 3/4"
• 3' -0' W. x 6'-B* H. x 1-3/4'
WAL L
EXIST. HOLLOW METAL
CEIUNG
SOLID CORE WOOD
NO.
ROOM NAME
AREA
FLOOR
BASE
CEILING
NOTES
NORTH
SOUTH
EAST
WEST
FRAM -
WITH F.B.G. 2007, CHAPTER 11,
HEIGHT
r-10-1
ACCESSIBLE
75 S.F.
EXIST. TILE
EXIST.
PAINT
PAINT
PANT
PAINT
EXIST.
EXIST.
2007 FFPC 7.2.1.4.1 �7.
TOILET ROOM
NICKEL FINISH
TILE
• HANDLE - ADA COMPLIANT LEVER TYPE,
LESS THAN I O��
ACT
+81-01 A.F.F.
.(R
2
F102FI
BREAK ROOM
66 S.F.
TILE
4"
TILE COVE
PAINT
PAIN-
NT
PAINT
PAINT
EXIST.
ACT
EXIST.
+81-01 A.F.F,
Fl 031
WAXING ROOM
72 S.F.
TILE
V COVE
TILE
PAIN'
PAINT
PAINT
PAINT
ACT
+&-17'
AFF.
Fl-04
HALLWAY
60 S.F�
TILE
4" COVE
PAINT
PAINT
PAINT
PAINT
ACT
+81-01
TI LE
A.F.F.
01-0-5 I
MANICURE
TABLES
337 S.F.
TILE
4'COVE
TILE
PANT
PAINT
PAINT
PAINT
ACT
+11-01
A.F.F.
1-0-61
PEDICURE SPA
337 S.F.
TILE
4° COVE
PAINT
PAIN'
PAINT
PAINT
ACT
+11-01
CHAIRS
TILE
1
A.F.F.
F107
1
WAITING AREA
80 S.F. S.F
TILE
'COVE
PANT
PAINT
PAINT
PANT
ACT
A-F.F
TILE
Fl-08-1
RECEPTION
42 S.F.
TILE
4* COVE
PAINT
PAINT
PAINT
PAINT
ACT
+11-01
A.F.F.
TILE
Fl-0-9-1
NAIL DRYING
TABLES
80 S.F.
TILE
COVE
TILE
PAINT
PAIN'
PAIN'
PAINT
ACT
+11-01
A.F,F.
I
NOTES:
1. FINISH TYPES & COLORS TO BE OWNER SELECTED.
2. GENERAL CONTRACTOR TO PROVED PLYWOOD WOT 2x BLOCKING FOR ALL ACCESSORIES & FIXTURES.
REFER TO BLOCKING DETAILS ON THIS SHEET.
3. TOILET ROOM LAYOUT & ACCESSORIES AS PER F.B.C. 2010, CHARTER 11.
4. CONTRACTOR TO SUBMIT SHOP DRAWINGS TO ARCHITECT FOR REVIEW FOR ALL NEW EQUIPMENT &
FIXTURES PRIOR TO PURCHASING.
5. CONTRACTOR TO FIELD VERIFY ALL CLEARANCES FOR ADA COMPLIANCE.
'v_ M
wws= DT* *I ing V: 9 a 0
EXISTING
C17-Y OF SOUTHh'i IA &q
BUILDING DEPT.
STRUCTUR4L
SECTION
�; no=
............
co
•
0
0
W
F_
co
rO
Lo
0
Lo
N
CL
■
• 3'-0* W. X 6-8" H. X 1 3/4"
• 3' -0' W. x 6'-B* H. x 1-3/4'
EXIST. HOLLOW METAL
SOLID CORE WOOD
• FRAME - HOLLOW METAL TO BE PAINTED
• HORIZONTAL SLIDING
EXIST. SELF-CLOSER. SATIN NICKEL TO CO )LY
COMPLY
DOOR TO BE PAINTED
FRAM -
WITH F.B.G. 2007, CHAPTER 11,
SECTIONS 11- 4,13.10 AND
HORIZONTAL SLIDING
11-4.13.11.
DOOR ALLOWED PER
• HINGES - (3) 4� BUTTS, SATIN
2007 FFPC 7.2.1.4.1 �7.
NICKEL FINISH
ROOM OCCUPANCY
• HANDLE - ADA COMPLIANT LEVER TYPE,
LESS THAN I O��
SATIN NICKEL
.(R
2
1\1
I • PRIVACY LOCK, SATIN NICKEL
EXISTING
C17-Y OF SOUTHh'i IA &q
BUILDING DEPT.
STRUCTUR4L
SECTION
�; no=
............
co
•
0
0
W
F_
co
rO
Lo
0
Lo
N
CL
■
•