12-249-005DEMOLITION REFLECTED CEILING PLAN
SCALE: 1/4" = 1' -0"
O F-\
OF7 A -04
DEMOLITION FLOOR PLAN
KEYED NOTES LEGEND
Fil PARTIAL EXIST. PARTITION WALL TO REMAIN
F 21 EXIST. CABINETRY AND SINK TO BE DEMOLISHED
F EXIST. WOMEN'S TOILET ROOM TO REMAIN.
44 EXIST. SINK TO BE REMOVED AND RELOCATED.
SEE SHEET A1.1 FOR NEW LOCATION.
F EXIST. SEMI - RECESSED TOILET PAPER DISPENSER TO
BE DEMOLISHED.
EXIST. GRAB BAR TO REMAIN
7❑ EXIST. WATER CLOSET TO REMAIN.
8❑ EXIST. COUNTERTOP & MIRROR TO REMAIN.
El EXIST. STRUCTURAL CONC. COLUMN TO REMAIN.
10 EXIST. UTILITY SINK TO BE DEMOLISHED_
11 EXIST. TILE FLOOR FINISH, WATER CLOSET, GRAB BARS
& SINK TO BE DEMOLISHED.
12 EXIST. ELECTRICAL PANEL B -1ATO BE RELOCATED.
SEE SHT. E -1.1 FOR NEW PANEL LOCATION.
13 EXIST. ELECTRICAL PANEL B-1 B TO BE RELOCATED
SEE SHT. E -1.1. FOR NEW PANEL LOCATION
14 EXIST. BANK TELLER CABINETRY TO BE DEMOLISHED
JUST BEYOND NEW DEMISING WALL LOCATION.
15 EXIST. PARTITION WALL TO BE DEMOLISHED.
16 EXIST. CONC. STRUCTURAL COLUMN TO REMAIN.
17 EXIST. PARTITION WALL AROUND CONC. STRUCTURAL
COLUMN TO BE DEMOLISHED.
i$ EXIST. SEMI - RECESSED, WALL MOUNTED,
FIRE- EXINGUISHER TO BE RELOCATED. SEE SHT. Ai .1.
FOR NEW LOCATION.
19 NEW LOCATION OF 1 -HR. FIRE RATED DEMISING WALL.
20 EXIST. DEMISING WALL TO REMAIN.
21 EXIST. PARTIAL STOREFRONT TO BE DEMOLISHED FOR
PAIR OF NEW STOREFRONT DOORS.
22 EXIST. WALL PARTITION & WALL CLEAN -OUT TO REMAIN.
23 EXIST. FLOOR CLEAN -OUT TO REMAIN.
24 DIMENSION TO CENTERLINE -OF -STUD
OF NEW 1 -HR. FIRE -RATED DEMISING WALL.
25 EXIST. CARPET FLOOR FINISH TO BE DEMOLISHED TO
LOCATION OF NEW DEMISING WALL LOCATION.
FIELD COORDINATE.
26 EXIST. WOOD LAMINATE FLOORING TO BE DEMOLISHED
TO LOCATION OF NEW DEMISING WALL LOCATION.
FIELD COORDINATE.
27 EXIST. VCT TILE FLOORING TO BE DEMOLISHED
TO LOCATION OF NEW DEMISING WALL LOCATION.
FIELD COORDINATE.
2$ EXIST. COUNTER TO BE CUT BACK TO DEMISING WALL.
DEMO. REF. CEILING PLAN
KEYED NOTES LEGEND
1❑ CEILING IN EXIST. WOMEN'S TOILET ROOM TO REMAIN.
21 CEILING IN EXIST. MEN'S TOILET ROOM TO REMAIN.
❑
3 EXIST. 2x2 FLOURESCENT LIGHT FIXTURE TO BE
REMOVED & RELOCATED. SEE SHEET A1.1 FOR
NEW LOCATION.
44 EXIST. DRYWALL SOFFIT, LOUVER &TUBE LIGHT FIXTURE
TO, BF_DEEMOLISHED TO JUST BEYOND LINE OF
R EXIST. 2x2 FLOURESCENT LIGHT FIXTURE TO BE REMOVED
& RELOCATED. SEE SHEET Al .1 FOR NEW LOCATION.
REXISTING 2x2 FLOURESCENT LIGHT FIXTURE TO BE
DEMOLISHED.
EEXIST. ACT TO BE DEMOLISHED TO JUST BEYOND LINE
OF NEW DEMISING WALL.
❑$EXISTING ACT. CLG. TO BE LOWERED TO +10' -V A.F.F.
EXIST. FIRE SPRINKLER HEAD TO BE RELOCATED.
SEE REFLECTED CEILING PLAN ON SHT. A -1.1.
10 EXIST. FIRE SPRINKLER HEAD TO BE RELOCATED TO
10' -0' A.F.F.
11 EXIST. A/C SUPPLY GRILL & DUCTWORK TO BE REMOVED.
12 EXIST. A/C RETURN GRILL & DUCTWORK TO BE REMOVED.
13 EXIST. FIRE SPRINKLER HEAD TO REMAIN.
EXISTL STOREFRONT TO BE REM VED
FOR AEW PAIR OF STOREFRO DOORS
SEE SHEET A1.3 FOR NEW DOORS.
■
STOREFRONT •
—DEMOLITION
SCALE: 1/4" = 1' -0"
/// EXIST.'//
HALLWAY
�I
& 1u 1—
EXIST.
WOMEN'S TOILET
`--.,(TO REMAIN)
EXIST. /;F'// PANE -1 A 1 � =
STAIR NO. 2 /EXI ��n I �� �—�
i-, 10
,s EXIST. �/ / �' ®_ �
PANEL B -1 B 13 I
FE� II
r---------- L
I EXIST. I I
l I CLOSET I i EXIST.
EN'S TOILET
F- -_=
I � I
s If
I• - --'j l_4 �
i 161
[ " " EXIST.
' I
BREAK ROOM
I II
L - -- . ------------ _
--------------------
I I I III ( - - - - --
l I II o
I
a
f
r n i
i
4 r
[ 24 "
f
FJIUK_Deji�
mq,
/// EXIST. / / /
ATM ROOM
I
I
I
I
I
I
I
I
I EXIST.
WAITING
I
I
I
DEMOLITION FLOOR
w
X25] ----
23
A -0.5
2 --
0
HAND MASSAGE a FACIAL��'.
CITE` OP SOUTH t IA
BUILDING DEPT�
f
STRUCTURAL SE," ION
"P "10VED FAY;
roe f'
F-\
,7
Oo
GENERAL NOTES
1. GENERAL CONTRACTOR TO VISIT SITE & FAMILIARIZE
THEMSELVES WITH ALL EXISTING & PROPOSED
CONDITIONS OF PROJECT PRIOR TO COMMENCEMENT OF
ANY WORK.
2. GENERAL CONTRACTOR SHALL FURNISH LABOR &
EQUIPMENT TO DISCONNECT, DISMANTLE, REMOVE &
SALVAGE IN THE DISPOSITION OF THE DEMOLITION
INDICATED ON THESE PLANS.
3, GENERAL CONTRACTOR SHALL TAKE ALL NECESSARY
PRECAUTIONS TO PREVENT DAMAGE TO EXISTING
STRUCTURE & EQUIPMENT TO REMAIN & SHALL BE FULLY
RESPONSIBLE FOR ANY DAMAGE TO EXISTING STRUCTURE
OR EQUIPMENT CAUSED BY THE OPERATION.
4. UPON COMPLETION OF THE DEMOLITION, THE ENTIRE
AREA SHALL BE CLEANED OF ALL DEBRIS AND PREPARED
FOR THE PROPOSED CONSTRUCTION.
5. EXISTING CONDITIONS NOT SHOWN ON THE
DEMOLITION/EXISTING PLAN DRAWINGS SHALL BE
REMOVED & REWORKED TO CONFORM TO THE PROPOSED
PLANS AS REQUIRED. 1
6. GENERAL CONTRACTOR IS RESPONSIBLE FOR THE
PROVISIONS OF BARRICADES & ALL OTHER SAFETY
EQUIPMENT AS REQUIRED B THE CONDITIONS OF THE
PROJECT SITE.
7. WHEN AN ITEM OR CONSTRUCTION ELEMENT IS NOTED TO
BE REMOVED, ALL ACCESSORIES, ,EQUIPMENT, PLUMBING
& ELECTRICAL CONNECTIONS, FLASHINGS, SIGNS
FRAMING & ALL ASSOCIATED CONNECTING ITEMS, ETC.
SHALL BE REMOVED ALONG WITH IT. THE EXISTING
CONSTRUCTION, WHICH SHALL REMAAN, SHALL BE LEFT
FREE OF THESE ITEMS & ANY OTHER LOSE
CONSTRUCTION & SHALL BE READY TO RECIEVE NEW
WORK, PATCHED & REPAIRED TO MATCH EXISTING NOR
ADJOINING AREA. 1
$. GENERAL CONTRACTOR SHALL CONTACT & REQUEST
FROM ANY & ALL UTILITY COMPANIES AS MAY BE
REQUIRED, SURVEYS LOCATING EXISTING CONDITIONS OF
THE PROJECT SITE. I
9. GENERAL CONTRACTOR SHALL INFORM & COORDINATE
W/ BUILDING MANAGEMENT LOCATION OF DUMPSTERS,
ETC. SO AS NOT TO DISRUPT OTHER TENANTS.
10. GENERAL CONTRACTOR TO NOTIFY ARCHITECT/ENGINEER
IMMEDIATELY WHEN ANY DISCREPANCIES ARISE.
11. UPON REMOVAL OF ALL FINISHES & EXPOSURE OF
STRUCTURE & HIDDEN CONDITIONS, GENERAL
CONTRACTOR TO NOTIFY ARCHITECT FOR FIELD
INSPECTION BEFORE CONTINUING,'UNLESS SO STATED BY
THE ARCHITECT.
12. ANY F'RE EXTINGUISHERS MOVED DURING CONSTRUCTION
ARE TO BE RELOCATED AT AN ADJACENT AREA AS PER
NFPA REQUIREMENTS. 1
13. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE
FOR IDENTIFYING, TAGGING OUT AND LOCKING OUT ALL
AFFECTED CIRCUITS PRIOR TO THE COMMENCEMENT OF
DEMOLITION.
THE ELECTRICAL CONTRACTOR SHALL ALSO BE REQUIRED
TO REMOVE ALL UNUSED CONDUITS & CONDUCTORS &
PROPERLY SUPPORT ALL EXISTINGCONDUITS &
CONDUCTORS THAT WILL REMAIN PRIOR TO THE START
OF NEW WORK. f
14. ANY DISCREPANCIES BETWEEN DRAWINGS & FIELD
CONDITIONS TO BE REPORTED TO ARCHITECT
IMMEDIATELY. 1
15. ALL EXISTING CONDITIONS, DIMENSIONS AND MATERIALS
OF CONSTRUCTION ARE TO BE VERIFIED IN THE FIELD
PRIOR TO ANY DEMOLITION WORK'OR ANY NEW
CONSTRUCTION.
16. AREAS OF BUILDING NOT PART OF THIS REMODEL TO BE
PROTECTED FROM DUST & DAMAGE DURING REMODEL.
17. ANY MATERIALS INSTALLED ABOVE CEILING DURING
REMODEL SHALL BE NON- COMBUSTABLE IN
ACCORDANCE W/ NFPA 13. 1
1$. THE REMOVAL OF ALL UTILITIES & SYSTEMS SHALL BE TO
THEIR FURTHEST POINT OF ORIGIN j,
19. SLAB CUTS TO BE COORDINATED W /
REQUIRED
DISCIPLINES & SUB - CONTRACTORS PRIOR TO
COMMENCEMENT.
20. ALL DEMOLITION WILL BE PERFORMED IN SUCH A
MANNER SO NOT TO BLOCK OR RESTRICT ANY MEANS OF
EGRESS, AS PER FBC 2010, SECTION 1303.3 'MEANS OF
EGRESS'.
21. GENERI\L CONTRACTOR TO COORDINATE THE REMOVAL
OF ALL FIXTURES W/ OWNER FOR DESIRED
REMOVAL/SALVAGING/REUSE. I
SYMBOLS
EXISTING TO BE DEMOLISHED
EXISTING WALL
'Y
LUMN
-----BUILDING DEPT. REVISIONS
DESCRIPTION
•
r r
i s i'aA1i
fl.Gh�2
CIO
00
m
�J
O
(D
T—
W
F_
�:D
V1
I-
rr
O
LO
T—
O
co
rl*--
Lid
N
CL
z
t
AMA
W
....