12-249-005DEMOLITION REFLECTED CEILING PLAN SCALE: 1/4" = 1' -0" O F-\ OF7 A -04 DEMOLITION FLOOR PLAN KEYED NOTES LEGEND Fil PARTIAL EXIST. PARTITION WALL TO REMAIN F 21 EXIST. CABINETRY AND SINK TO BE DEMOLISHED F EXIST. WOMEN'S TOILET ROOM TO REMAIN. 44 EXIST. SINK TO BE REMOVED AND RELOCATED. SEE SHEET A1.1 FOR NEW LOCATION. F EXIST. SEMI - RECESSED TOILET PAPER DISPENSER TO BE DEMOLISHED. EXIST. GRAB BAR TO REMAIN 7❑ EXIST. WATER CLOSET TO REMAIN. 8❑ EXIST. COUNTERTOP & MIRROR TO REMAIN. El EXIST. STRUCTURAL CONC. COLUMN TO REMAIN. 10 EXIST. UTILITY SINK TO BE DEMOLISHED_ 11 EXIST. TILE FLOOR FINISH, WATER CLOSET, GRAB BARS & SINK TO BE DEMOLISHED. 12 EXIST. ELECTRICAL PANEL B -1ATO BE RELOCATED. SEE SHT. E -1.1 FOR NEW PANEL LOCATION. 13 EXIST. ELECTRICAL PANEL B-1 B TO BE RELOCATED SEE SHT. E -1.1. FOR NEW PANEL LOCATION 14 EXIST. BANK TELLER CABINETRY TO BE DEMOLISHED JUST BEYOND NEW DEMISING WALL LOCATION. 15 EXIST. PARTITION WALL TO BE DEMOLISHED. 16 EXIST. CONC. STRUCTURAL COLUMN TO REMAIN. 17 EXIST. PARTITION WALL AROUND CONC. STRUCTURAL COLUMN TO BE DEMOLISHED. i$ EXIST. SEMI - RECESSED, WALL MOUNTED, FIRE- EXINGUISHER TO BE RELOCATED. SEE SHT. Ai .1. FOR NEW LOCATION. 19 NEW LOCATION OF 1 -HR. FIRE RATED DEMISING WALL. 20 EXIST. DEMISING WALL TO REMAIN. 21 EXIST. PARTIAL STOREFRONT TO BE DEMOLISHED FOR PAIR OF NEW STOREFRONT DOORS. 22 EXIST. WALL PARTITION & WALL CLEAN -OUT TO REMAIN. 23 EXIST. FLOOR CLEAN -OUT TO REMAIN. 24 DIMENSION TO CENTERLINE -OF -STUD OF NEW 1 -HR. FIRE -RATED DEMISING WALL. 25 EXIST. CARPET FLOOR FINISH TO BE DEMOLISHED TO LOCATION OF NEW DEMISING WALL LOCATION. FIELD COORDINATE. 26 EXIST. WOOD LAMINATE FLOORING TO BE DEMOLISHED TO LOCATION OF NEW DEMISING WALL LOCATION. FIELD COORDINATE. 27 EXIST. VCT TILE FLOORING TO BE DEMOLISHED TO LOCATION OF NEW DEMISING WALL LOCATION. FIELD COORDINATE. 2$ EXIST. COUNTER TO BE CUT BACK TO DEMISING WALL. DEMO. REF. CEILING PLAN KEYED NOTES LEGEND 1❑ CEILING IN EXIST. WOMEN'S TOILET ROOM TO REMAIN. 21 CEILING IN EXIST. MEN'S TOILET ROOM TO REMAIN. ❑ 3 EXIST. 2x2 FLOURESCENT LIGHT FIXTURE TO BE REMOVED & RELOCATED. SEE SHEET A1.1 FOR NEW LOCATION. 44 EXIST. DRYWALL SOFFIT, LOUVER &TUBE LIGHT FIXTURE TO, BF_DEEMOLISHED TO JUST BEYOND LINE OF R EXIST. 2x2 FLOURESCENT LIGHT FIXTURE TO BE REMOVED & RELOCATED. SEE SHEET Al .1 FOR NEW LOCATION. REXISTING 2x2 FLOURESCENT LIGHT FIXTURE TO BE DEMOLISHED. EEXIST. ACT TO BE DEMOLISHED TO JUST BEYOND LINE OF NEW DEMISING WALL. ❑$EXISTING ACT. CLG. TO BE LOWERED TO +10' -V A.F.F. EXIST. FIRE SPRINKLER HEAD TO BE RELOCATED. SEE REFLECTED CEILING PLAN ON SHT. A -1.1. 10 EXIST. FIRE SPRINKLER HEAD TO BE RELOCATED TO 10' -0' A.F.F. 11 EXIST. A/C SUPPLY GRILL & DUCTWORK TO BE REMOVED. 12 EXIST. A/C RETURN GRILL & DUCTWORK TO BE REMOVED. 13 EXIST. FIRE SPRINKLER HEAD TO REMAIN. EXISTL STOREFRONT TO BE REM VED FOR AEW PAIR OF STOREFRO DOORS SEE SHEET A1.3 FOR NEW DOORS. ■ STOREFRONT • —DEMOLITION SCALE: 1/4" = 1' -0" /// EXIST.'// HALLWAY �I & 1u 1— EXIST. WOMEN'S TOILET `--.,(TO REMAIN) EXIST. /;F'// PANE -1 A 1 � = STAIR NO. 2 /EXI ��n I �� �—� i-, 10 ,s EXIST. �/ / �' ®_ � PANEL B -1 B 13 I FE� II r---------- L I EXIST. I I l I CLOSET I i EXIST. EN'S TOILET F- -_= I � I s If I• - --'j l_4 � i 161 [ " " EXIST. ' I BREAK ROOM I II L - -- . ------------ _ -------------------- I I I III ( - - - - -- l I II o I a f r n i i 4 r [ 24 " f FJIUK_Deji� mq, /// EXIST. / / / ATM ROOM I I I I I I I I I EXIST. WAITING I I I DEMOLITION FLOOR w X25] ---- 23 A -0.5 2 -- 0 HAND MASSAGE a FACIAL��'. CITE` OP SOUTH t IA BUILDING DEPT� f STRUCTURAL SE," ION "P "10VED FAY; roe f' F-\ ,7 Oo GENERAL NOTES 1. GENERAL CONTRACTOR TO VISIT SITE & FAMILIARIZE THEMSELVES WITH ALL EXISTING & PROPOSED CONDITIONS OF PROJECT PRIOR TO COMMENCEMENT OF ANY WORK. 2. GENERAL CONTRACTOR SHALL FURNISH LABOR & EQUIPMENT TO DISCONNECT, DISMANTLE, REMOVE & SALVAGE IN THE DISPOSITION OF THE DEMOLITION INDICATED ON THESE PLANS. 3, GENERAL CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PREVENT DAMAGE TO EXISTING STRUCTURE & EQUIPMENT TO REMAIN & SHALL BE FULLY RESPONSIBLE FOR ANY DAMAGE TO EXISTING STRUCTURE OR EQUIPMENT CAUSED BY THE OPERATION. 4. UPON COMPLETION OF THE DEMOLITION, THE ENTIRE AREA SHALL BE CLEANED OF ALL DEBRIS AND PREPARED FOR THE PROPOSED CONSTRUCTION. 5. EXISTING CONDITIONS NOT SHOWN ON THE DEMOLITION/EXISTING PLAN DRAWINGS SHALL BE REMOVED & REWORKED TO CONFORM TO THE PROPOSED PLANS AS REQUIRED. 1 6. GENERAL CONTRACTOR IS RESPONSIBLE FOR THE PROVISIONS OF BARRICADES & ALL OTHER SAFETY EQUIPMENT AS REQUIRED B THE CONDITIONS OF THE PROJECT SITE. 7. WHEN AN ITEM OR CONSTRUCTION ELEMENT IS NOTED TO BE REMOVED, ALL ACCESSORIES, ,EQUIPMENT, PLUMBING & ELECTRICAL CONNECTIONS, FLASHINGS, SIGNS FRAMING & ALL ASSOCIATED CONNECTING ITEMS, ETC. SHALL BE REMOVED ALONG WITH IT. THE EXISTING CONSTRUCTION, WHICH SHALL REMAAN, SHALL BE LEFT FREE OF THESE ITEMS & ANY OTHER LOSE CONSTRUCTION & SHALL BE READY TO RECIEVE NEW WORK, PATCHED & REPAIRED TO MATCH EXISTING NOR ADJOINING AREA. 1 $. GENERAL CONTRACTOR SHALL CONTACT & REQUEST FROM ANY & ALL UTILITY COMPANIES AS MAY BE REQUIRED, SURVEYS LOCATING EXISTING CONDITIONS OF THE PROJECT SITE. I 9. GENERAL CONTRACTOR SHALL INFORM & COORDINATE W/ BUILDING MANAGEMENT LOCATION OF DUMPSTERS, ETC. SO AS NOT TO DISRUPT OTHER TENANTS. 10. GENERAL CONTRACTOR TO NOTIFY ARCHITECT/ENGINEER IMMEDIATELY WHEN ANY DISCREPANCIES ARISE. 11. UPON REMOVAL OF ALL FINISHES & EXPOSURE OF STRUCTURE & HIDDEN CONDITIONS, GENERAL CONTRACTOR TO NOTIFY ARCHITECT FOR FIELD INSPECTION BEFORE CONTINUING,'UNLESS SO STATED BY THE ARCHITECT. 12. ANY F'RE EXTINGUISHERS MOVED DURING CONSTRUCTION ARE TO BE RELOCATED AT AN ADJACENT AREA AS PER NFPA REQUIREMENTS. 1 13. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR IDENTIFYING, TAGGING OUT AND LOCKING OUT ALL AFFECTED CIRCUITS PRIOR TO THE COMMENCEMENT OF DEMOLITION. THE ELECTRICAL CONTRACTOR SHALL ALSO BE REQUIRED TO REMOVE ALL UNUSED CONDUITS & CONDUCTORS & PROPERLY SUPPORT ALL EXISTINGCONDUITS & CONDUCTORS THAT WILL REMAIN PRIOR TO THE START OF NEW WORK. f 14. ANY DISCREPANCIES BETWEEN DRAWINGS & FIELD CONDITIONS TO BE REPORTED TO ARCHITECT IMMEDIATELY. 1 15. ALL EXISTING CONDITIONS, DIMENSIONS AND MATERIALS OF CONSTRUCTION ARE TO BE VERIFIED IN THE FIELD PRIOR TO ANY DEMOLITION WORK'OR ANY NEW CONSTRUCTION. 16. AREAS OF BUILDING NOT PART OF THIS REMODEL TO BE PROTECTED FROM DUST & DAMAGE DURING REMODEL. 17. ANY MATERIALS INSTALLED ABOVE CEILING DURING REMODEL SHALL BE NON- COMBUSTABLE IN ACCORDANCE W/ NFPA 13. 1 1$. THE REMOVAL OF ALL UTILITIES & SYSTEMS SHALL BE TO THEIR FURTHEST POINT OF ORIGIN j, 19. SLAB CUTS TO BE COORDINATED W / REQUIRED DISCIPLINES & SUB - CONTRACTORS PRIOR TO COMMENCEMENT. 20. ALL DEMOLITION WILL BE PERFORMED IN SUCH A MANNER SO NOT TO BLOCK OR RESTRICT ANY MEANS OF EGRESS, AS PER FBC 2010, SECTION 1303.3 'MEANS OF EGRESS'. 21. GENERI\L CONTRACTOR TO COORDINATE THE REMOVAL OF ALL FIXTURES W/ OWNER FOR DESIRED REMOVAL/SALVAGING/REUSE. I SYMBOLS EXISTING TO BE DEMOLISHED EXISTING WALL 'Y LUMN -----BUILDING DEPT. REVISIONS DESCRIPTION • r r i s i'aA1i fl.Gh�2 CIO 00 m �J O (D T— W F_ �:D V1 I- rr O LO T— O co rl*-- Lid N CL z t AMA W ....