11-715-016A NAC 75CD 75CD 75CD 75CD (E) (R) (R) (R) EXISTING FIRE ALARM CONTROL PANEL ® BUILDING LOBBY NOTE: CONTACT FIRE ALARM CONTRACTOR ENGINEERING SYSTEM TECNOLOGY (EST) FOR ANY IMPROVEMENT /ADDITION OR MODIFICATION OF EXISTING SYSTEM. DUAL TELCO LINES CONNECTED VIA DACT TO A REMOTE SUPERVISING STATION F AC P (EXISTING) AC POWER (120V 20A MAX.) 2 #12 THWN IN 1/2" C CIRCUIT R1 -53 (EXISTING) EXISTING ENCLOSURE GROUNDED Reproduced by HILTI, Inc. Courtesy of FIRESTOP SYSTEMS Underwriters Laboratories, Inc. System No, C -AJ -1388 F Rating - 2 Hr T Rating - 0 Hr 75CD 75CD 15/75CD 15/75CD (R) (N) (N) (N) REA OF WORK IS SHOWN IN FIRE 1. DEVICES IN BUILDING NOT SHOWN. EOL WIRE LEGEND: CLASS B WIRING A — (INITIATING) 2 CONDUCTOR #16 SOL CU SHIELDED FPLR B — (NOTIFICATION — HORN /STROBE) 2 CONDUCTOR #14 SOL CU FPLR OTHERWISE USE APROVED FPLP WIRE IN PLENUM SPACES. NOTE: FOR EXACT LOCATION AND QUANTITY OF FIRE ALARM SYSTEM DEVICES, REFER TO FLOOR PLAN DRAWING. NOTE: (E) — EXISTING FA DEVICES (N) — NEW FA DEVICES (R) — RELOCATED FA DEVICES GROUND FLOOR FIRE ALARM SYSTEM RISER DIAGRAM SCALE: N.T.S. "I ,SS I fl' C US 5 A ?`' 1. Floor or Wall Assembly Min 4 -1/2 in. thick reinforced lightweight or normal weight (100 -150 pcf) concrete. Wall may also be constructed of any UL Classified Blocks *. Max area of opening 224 sq in. with max dimension of 32 in. See Concrete Blocks (CAZT) in the Fire Resistance Directory for names of C1P16FfAturers. 2. Conduit One or more nom 4 in diam (or smaller) steel electrical metallic tubing or steel conduit to be installed either concentrically or eccentrically within the firestop system. The space between conduits or tubes shall be min 0 in. (point contact) to max 1/2 in. The annular space between the conduit or tube and periphery of opening shall be min 0 in. (point contact) to max 2 -3/4 in. Conduit or tube to be rigidly supported on both sides of floor or wall assembly. Conduit — Nom 4 in. diem (or smaller) steel electrical metallic conduit or steel conduit. 3. Fill, Void or Cavity Material * — Foam Min 5 in. thickness of fill material applied within the annulus, extending 1/2 in. above the top surface of the floor or both surfaces of wall and overlapping the concrete 1/2 in. on all sides of the opening. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- CP 620 Fire Foam *Bearing the UL Classification Mark System No, W -L -1095 F Ratings - 1 & 2 Hr (See Item 1) T Ratings - 1 & 2 Hr (See Item 3) L Rating At Ambient - Less Than 1 CFM /Sq Ft L Rating At 400 F - 4 CFM /Sq Ft FIRESTOP SYSTEMS 1�SSIFj�D C US FONT VIEW SECTION A -A 1. Wall Assembly — The 1 or 2 hr fire —rated gypsum wallboard /stud wall assembly shall be constructed of the materials and in the manner described in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs — Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. lumber spaced 16 in. OC. Steel studs to be min 2 -1/2 in. wide and spaced max 24 in. OC. B. Wallboard, Gypsum* — 5/8 in. thick, 4 ft wide with square or tapered edges. The gypsum wallboard type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire Resistance Directory. Max size of opening 2 -5/8 in. by 18 in. The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed. 2. Electric Metallic Tubing (EMT) — One or more nom 1 in. diam steel electric tubing. The annular space shall be min 1/2 in. to a max 1 in. Conduit to be rigidly supported on both sides of wall assembly. 3. Fill, Void or Cavity Material* — Sealant — For 2 hr F Rating, min 1 -1/4 in. thickness of fill material applied within the annulus, flush with both surfaces of wall. For 1 hr F Rating, min 5/8 in. thickness of fill material applied within the annulus, flush with both surfaces of wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI, Inc. — FS —ONE Sealant *Bearing the UL Classification Marking PENETRATION DETAILS EIRE ANDZOR SMOKE RATED WALE OR FLOOR. SCALE: N.T.S. FIRE ALARM LEGEND FACP EXISTING ADDRESSABLE FIRE ALARM CONTROL PANEL (LOCATED AT BUILDING LOBBY) ® MANUAL PULL STATION O SMOKE DETECTOR CO CARBON MONOXIDE DETECTOR p HEATE DETECTOR G SMOKE DUCT DETECTOR W/ RELAY M< HORN /STROBE MULTICANDELA, SYSTEM SENSOR P2R ® STROBE LIGHT MULTICANDELA, SYSTEM SENSOR SR Q SWITCH (BY OTHERS) TAMPER SWITCH (BY OTHERS) V) ca H~¢ (n Ir v L I ° ° W W (� (f) ° Ld Ld _° J Q a_ w Ld V) 0a_ Qx 0 U) O � Z w w � ~ I o o ¢° �� g SEQUENCE 0 Z a da Q 0 nf ° J° \ Q OF �Q �4 Cn z OPERATIONS Q Cn 1- oQ oQ Q �a Imo- Z Z Z E � F- ov ° � 0- (wig Cn Cn cr) PULL STATION DETECTORS (AREA) t F SPKLR FLOW SW M Mir VALVE TAMP SW AC POWER FAILURE LOW BATTERY OPEN FAULT GROUND FAULT NAC SHORT FAULT MISSING PHONE LINE DUCT SMOKE DET FIRE ALARM LEGEND FACP EXISTING ADDRESSABLE FIRE ALARM CONTROL PANEL (LOCATED AT BUILDING LOBBY) ® MANUAL PULL STATION O SMOKE DETECTOR CO CARBON MONOXIDE DETECTOR p HEATE DETECTOR G SMOKE DUCT DETECTOR W/ RELAY M< HORN /STROBE MULTICANDELA, SYSTEM SENSOR P2R ® STROBE LIGHT MULTICANDELA, SYSTEM SENSOR SR gFLOW SWITCH (BY OTHERS) TAMPER SWITCH (BY OTHERS) SYSTEM OVERVIEW: 1) SYSTEM IS SINGLE STANDARD SCL LOOP, NFPA 4 STYLE. 2) SYSTEM IS A REMOTE SUPERVISING STATION. 3) SYSTEM IS AN ADDRESSABLE POWER LIMITED SYSTEM. 4) NOTIFICATION APPLIANCE CIRCUITS ARE STYLE Y, CLASS B. 5) USE 2 CONDUCTORS #14 (MIN.), JACKETED FIRE POWER LIMITED (FPL) WPW OR EQUIVALENT FOR THE NOTIFICATION CIRCUITS. 6) NOTIFICATION APPLIANCES MAXIMUM CURRENT PER CIRCUIT IS 2.5 AMPS. 7) FOR SLC LOOP, USE 2/18 TWISTED WIRE MIN. 8) ACOUSTICAL CEILING AND GWB CEILING THROUGHOUT THE SPACE. 9) NOTIFICATION CIRCUIT TO BE 15 DB ABOVE AMBIENT NOISE IN ALL AREAS. 10) DETECTORS MUST BE PLACED 3 FEET AWAY MINIMUM FROM ANY AIR DIFFUSER. 11) ELECTRICAL /FIRE ALARM CONTRACTOR SHALL SUBMIT A COMPLETE SET OF FIRE ALARM SHOP DRAWINGS TO ARCHITECT /ENGINEER FOR APPROVAL BEFORE THE BEGINNING OF WORK. THIS SET SHALL INCLUDE A COMPLETE RISER DIAGRAM, POINT TO POINT CONNECTION DIAGRAM, DEVICES ADDRESS LIST, BACK —UP BATTERY CALCULATIONS, VOLTAGE DROP CALCULATIONS AND SPEC SHEETS. SPECIFICATIONS: 1) ALL EQUIPMENT SHALL BE UL APPROVED. 2) ALL FIRE ALARM EQUIPMENT FOR THIS PROJECT SHALL BE RATED FOR POWER LIMITED. 3) CABLE SIZE SHALL COMPLY WITH ARTICLE 760 -71 AND THE CABLE INSTALLATION SHALL COMPLY WITH THE SEPARATION AND USE OF CONDUCTORS AND CABLES AS SPECIFIED IN ARTICLES 760 -54 AND 760 -61 OF THE NEC. 4) BUILDING WIRING SHALL SPECIFICALLY CONFORM WITH THE NEC ARTICLE 760 PART C FOR POWER LIMITED FIRE PROTECTION SIGNAL CIRCUITS WITH EMPHASIS ON ARTICLE 760 -52(b) ON POWER LIMITED WIRING METHODS AND MATERIALS. 5) MINIMUM WIRE SIZE: a) #18 AWG COPPER (2/18 FPLR TWISTED & SHIELDED) FOR INITIATING DEVICES LOOP. b) #14 AWG COPPER (2/14 FPL) FOR NOTIFICATION DEVICES CIRCUIT. 6) ALL NEW WIRING INSTALLED IN DUCTS, PLENUMS AND OTHER SPACES USED FOR ENVIRONMEMNTAL AIR SHALL BE PLENUM RATED, FPLP, AS PER NEC ARTICLE 760 -61. 7) ALL ALARM NOTIFICATION DEVICES SHALL BE AUDIBLE AND VISUAL (UNLESS SPECIFIED) AND SHALL BE VIA HORN STROBE COMBINATION DEVICES. STROBES SHALL BE CLEAR XENON TYPE, WITH INTENSITY OF 75 CANDELAS, U.O.N., AS PER ARTICLE 4.28(1) THROUGH (5) OF THE ADA GUIDELINES AND AS PER ARTICLE 4.28.2 & 4.28.3 OF THE FLORIDA ACCESIBILITY CODE. 8) HORN STROBES AND STROBE DEVIECS SHALL BE PLACED 80" (6' -8 ") ABOVE THE HIGHEST FLOOR LEVEL WITHIN THE SPACE OR 6" BELOW THE CEILING, WHICHEVER IS LOWER AS PER ADA GUIDELINES AND ARTICLE 4.28(6) OF THE NFPA -72. 9) MANUAL INITIATING DEVICES SHALL BE PLACED 48" (4') ABOVE FINISH FLOOR. 10) MAXIMUM OVER— CURRENT PROTECTION FOR OFIRE ALARM PANEL SHALL BE 20 AMPS. fa a 1, n' a dt?a.1) r' 1 c sR't�t'KDXI,��.7 � k o I, 6,�. "" FG ENGINEERS, INC. } Frank Garcia, P.E. t� .'+ r c # 60778 ` 3001 PONCE DE LEON BLVD. SUITE -101. CORAL GABLES, FLORIDA 33134 PH: (305) 441 -5892, FAX: (305) 441 -5893 fE-mail: fgarciaf @bellsouth.net C -A. #:26052 I INTERIOR RENOVATION FOR: I HAND & STONE Massage & Facial Spa 7301 SW 57th CT., SUITE 170, SOUTH MIAMI, FL 33143 FORM GROUP, INC. 4300 SW 73 AVE., SUITE 106, MIAMI, FL 33155 TEL. 305.443.4244 EX. 305.443.3338 CORPORATE LICENSE No. AA- 26000668 ARCHITECT OF RECORD: OMAR MORALES rvo NU TiiHE AR ' D AT,HI CTGTENAIrD !S F No. AR, `3F F-1 51 TITLE: SCALE: PROJECT N0. 11 -606 DATE: JUNE 3. 12011 REVISIONS: DRAWING NO.: E! 3