Loading...
11-715-011BY ORDER OF THE CITY OF SOUTH MIAMI THE MAXIMUM OCCUPANT LOAD OF THIS ESTABLISHEMENT IS XXX OCCUPANT LOAD SIGN DETAIL N.T.S. 8 1 /2 "x11" LAMINATE SIGN TO BE POSTED AT MAIN ENTRANCE. 2" LETTERS 1" LETTERS 2" LETTERS y PROPOSED LIFE SAFETY PLAN scale: 1/4"=T-0-" EXISTING SPACE- 2,047 S.F. LIFE SAFETY LEGEND •F.E. WALL MOUNTED FIRE' EXTINGUISHER r�! riri. TRAVEL DISTANCE — — — — — — MAX. DIAGONAL OF AREA SERVED ---- - - - - -- MIN. DISTANCE BETWEEN EXITS EMERGENCY LIGHT SEE ELECTRICAL DWG'S EMERENCY EXIT SIGN SEE ELECTRICAL DWG'S FIRE PROTECTION COMPONENTS 1. FIRE ALARM SYSTEM 2. EXISTING BUILDING HAS SPRINKLER SYSTEM 3. FIRE EXTINGUISHER ONE PER 2,500 SF. 4. TENANT DEMISING WALLS 1HR. RATED WALL LEGEND WALL TYPE 1 ❑j 77 EXISTING 1HR RATED TENANT DEMISING PARTITION. 3 8" METAL FRAMING WITH 2LAYERS TYPE X, GYP. BD. WALL TYPE 2 EXISTING 2 –HR RATED EXTERIOR CMU WALL. EXISTING TYPICAL 2 HOUR ASSEMBLY RATING 8" CMU WALL W /VERTICLE REINFORCING. (SEE WALL TYPES FOR DETAILS) WALL TYPE 3 ❑3 _______,_ __ 3 -5/8" STL STUDS (20 GA.) ® 24" O.C. W/ 1/2" DRYWALL WALL BD. EA. SIDE APPLIED HORIZONTALLY, ATTACHED TO EA. STUD W /1" TYPE S -12 SCREWS 12" O.C. MAX. WALL TYPE 4 n4 ors -r - sr 3 -5/8" STL STUDS (25 GA.) ® 24" O.C. W/ 1/2" DRYWALL WALL BD. EA. SIDE APPLIED HORIZONTALLY, ATTACHED TO EA. STUD W /1" TYPE S -12 SCREWS 12" Q.C. MAX. PROVIDE BATT SOUND ATTENUATION INSULATION. LOW INTERIOR PARTITION (NEW) 6" STL STUDS (20 GA.) ® 24" O.C. STAGGERED TO FOR 6" PARTITION – BAR WALL TYPE 6 ❑ 6 6" STL STUDS (20 GA.) ® 24" O.C. W/ 5/8" "TYPE X" DRYWALL WALL BD. EA. SIDE APPLIED HORIZONTALLY, ATTACHED TO EA. STUD W /1" TYPE S -12 SCREWS 12" O.C. MAX. *STAINLESS STEEL LINER PANELS FULL HEIGHT AT KITCHEN WALL. FLORIDA BUILDING CODE'S MINIMUM OCCUPANT LOAD PURSUANT TO LIFE SAFETY CODE (NFPA 101) Chsp. 73.1 GROUND FLOOR MIN. REWIRED WIDTH. (INCH) .2" .3" PROVIDED WIDTH. (INCH) OCCUPANCY OCCUPANCY LOAD AREA TOTAL DOOR STAIR DOOR STAIR GENERAL BUSINESS AREA AREA /100s.f. GROSS 2,047 SF 21 PERSONS 4.2" — 4.2" TOTAL: 21 PERSONS 4.2" _ 102" MIAMI -DADF COiSfvl'Y FIRE DEFARTMENT BLDG, PER.MIT__t FIRE SUPPRESSION tn3�;(e fi !4?��s(l -X-1 DXrE; Z, .,p C k o 0 CYJ INTERIOR RENOVATION FOR:,, HAND & STONE Massage & Facial Spa 7301 SW 57th CT., SUITE 170, SOUTH MIAMI, FL 33143 j FORM GROUP, INC. 4300 SW 73 AVE, SUITE 106, MIAMI, FL 33155 TEL 305A43A244 FX, 305A43.3338 CORPORATE LICENSE Na AA- 26000668 ARCHITECT OF RECORD: OMAR MORALES ARCHITECT LICENSE Na AR- 00014851 111, AH 1 1I 1,, TF IIRR,- AND DID— Ake TIC RGP OF FOFM GFOUP 1NC VO PART h1Y:RO, 511A HD CUPIED, DIECLOSE'D DR USED --UT — FF=ER COMFR'T OF tLN: TITLE: SCALE: PROJECT NO. 11606 DATE JUNE 3, 2011 REVISIONS: DRAWING NO- LS-1