11-715-011BY ORDER OF
THE CITY OF SOUTH MIAMI
THE MAXIMUM OCCUPANT LOAD
OF THIS ESTABLISHEMENT IS
XXX
OCCUPANT LOAD SIGN DETAIL
N.T.S.
8 1 /2 "x11"
LAMINATE SIGN TO
BE POSTED AT MAIN
ENTRANCE.
2" LETTERS
1" LETTERS
2" LETTERS
y
PROPOSED LIFE SAFETY PLAN
scale: 1/4"=T-0-"
EXISTING SPACE-
2,047 S.F.
LIFE SAFETY LEGEND
•F.E. WALL MOUNTED FIRE' EXTINGUISHER
r�! riri. TRAVEL DISTANCE
— — — — — — MAX. DIAGONAL OF AREA SERVED
---- - - - - -- MIN. DISTANCE BETWEEN EXITS
EMERGENCY LIGHT
SEE ELECTRICAL DWG'S
EMERENCY EXIT SIGN
SEE ELECTRICAL DWG'S
FIRE PROTECTION COMPONENTS
1. FIRE ALARM SYSTEM
2. EXISTING BUILDING HAS SPRINKLER
SYSTEM
3. FIRE EXTINGUISHER ONE PER 2,500 SF.
4. TENANT DEMISING WALLS 1HR. RATED
WALL LEGEND
WALL TYPE 1
❑j 77 EXISTING 1HR RATED TENANT DEMISING
PARTITION. 3 8" METAL FRAMING WITH
2LAYERS TYPE X, GYP. BD.
WALL TYPE 2
EXISTING 2 –HR RATED EXTERIOR CMU WALL.
EXISTING TYPICAL 2 HOUR ASSEMBLY RATING 8"
CMU WALL W /VERTICLE REINFORCING. (SEE WALL
TYPES FOR DETAILS)
WALL TYPE 3
❑3 _______,_ __ 3 -5/8" STL STUDS (20 GA.) ® 24" O.C. W/ 1/2"
DRYWALL WALL BD. EA. SIDE APPLIED
HORIZONTALLY, ATTACHED TO EA. STUD W /1"
TYPE S -12 SCREWS 12" O.C. MAX.
WALL TYPE 4
n4 ors -r - sr 3 -5/8" STL STUDS (25 GA.) ® 24" O.C. W/ 1/2"
DRYWALL WALL BD. EA. SIDE APPLIED
HORIZONTALLY, ATTACHED TO EA. STUD W /1"
TYPE S -12 SCREWS 12" Q.C. MAX. PROVIDE BATT
SOUND ATTENUATION INSULATION.
LOW INTERIOR PARTITION (NEW)
6" STL STUDS (20 GA.) ® 24" O.C. STAGGERED
TO FOR 6" PARTITION – BAR
WALL TYPE 6
❑
6 6" STL STUDS (20 GA.) ® 24" O.C. W/ 5/8"
"TYPE X" DRYWALL WALL BD. EA. SIDE APPLIED
HORIZONTALLY, ATTACHED TO EA. STUD W /1"
TYPE S -12 SCREWS 12" O.C. MAX.
*STAINLESS STEEL LINER PANELS FULL HEIGHT AT
KITCHEN WALL.
FLORIDA BUILDING CODE'S MINIMUM OCCUPANT LOAD
PURSUANT TO LIFE SAFETY CODE (NFPA 101) Chsp. 73.1
GROUND FLOOR
MIN. REWIRED WIDTH.
(INCH)
.2" .3"
PROVIDED WIDTH.
(INCH)
OCCUPANCY
OCCUPANCY LOAD
AREA
TOTAL
DOOR
STAIR
DOOR
STAIR
GENERAL BUSINESS
AREA
AREA /100s.f. GROSS
2,047 SF
21
PERSONS
4.2"
—
4.2"
TOTAL:
21 PERSONS
4.2"
_
102"
MIAMI -DADF COiSfvl'Y FIRE DEFARTMENT
BLDG, PER.MIT__t
FIRE SUPPRESSION tn3�;(e fi !4?��s(l -X-1
DXrE; Z,
.,p
C k o 0 CYJ
INTERIOR RENOVATION FOR:,,
HAND & STONE Massage & Facial Spa
7301 SW 57th CT., SUITE 170, SOUTH MIAMI, FL 33143 j
FORM GROUP, INC.
4300 SW 73 AVE, SUITE 106, MIAMI, FL 33155
TEL 305A43A244 FX, 305A43.3338
CORPORATE LICENSE Na AA- 26000668
ARCHITECT OF RECORD: OMAR MORALES
ARCHITECT LICENSE Na AR- 00014851
111, AH 1 1I 1,, TF IIRR,- AND DID— Ake TIC RGP OF FOFM GFOUP 1NC
VO PART h1Y:RO, 511A HD CUPIED, DIECLOSE'D DR USED --UT — FF=ER COMFR'T OF tLN:
TITLE:
SCALE:
PROJECT NO.
11606
DATE
JUNE 3, 2011
REVISIONS:
DRAWING NO-