11-715-004�- EXISTING BUILDING EXIT
i STAIR AND CORIDOOR.
SHOWN FOR REFERENCE
ONLY
5TAIR NO2
GENERAL DEMOLITION LEGEND;
1❑ REMOVE GYPSUM WALL BOARD PARTITIONS INDICATED BY DASHED LINES.
R2 REMOVE EXISTING DOORS, FRAMES & HARDWARE INDICATED BY DASHED LINES.
EXISTING DOOR, FRAME & HARDWARE TO REMAIN.
REMOVE ALL EXISTING WALL FINISHES, TILE, MOLDINGS, PREPARE SURFACE FOR NEW
FINISH
I ■I
5 F REMOVE EXISTING CARPET, GLUE DOWN VINYL TILE, OR MISC. FLOORING AND
PREPARE SURFACE TO RECEIVE NEW FINISH.
REMOVE EXISTING ANY CABINETRY OR OTHER
MISCELLANEOUS MILLWORK
❑
7 EXISTING STOREFRONT WINDOWS, FIXED WINDOWS AND FRAMES TO REMAIN. PROVIDE
PROTECTION DURING CONSTRUCTION OPERATIONS.
88] REMOVE EXISTING CEILING TILE & GRID OR GYPSUM WALL BOARD CEILING AND SOFFITS WITHIN
DEMO AREA.
REMOVE EXISTING PLUMBING FIXTURES. CAP WATER, SANITARY, AND VENT LINES.
10 REMOVE EXISTING LIGHT FIXTURES THROUGHOUT ENTIRE AFFECTED DEMO AREA.
11 REMOVE ALL EXISTING H.V.A.C. SUPPLY & RETURN GRILLS, AND DUCTWORK WITHIN AFFECTED DEMO
AREA. CAP AND SEAL ANY EXISTING H.V.A.C. ROOF PENETRATIONS, EXHAUST DUCTS, ETC. PER
ROOF PATCH NOTES ON M -1. REFER TO MECHANICAL DRAWINGS FOR NEW DUCT LAYOUT.
12 REMOVE EXISTING CEILING FINISH PREPARE SURFACE FOR NEW FINISH.
13 EXISTING ELECTRICAL PANEL AND PARTITION TO REMAIN
14 CAP EXISTING FLOOR OUTLET. SEE ELECT DWGS FOR ADDITIONAL INFORMATION
A DEMOLITION PLAN
scale: 1/4 " =1' -0"
EXISTING ADJACENT TENANT
SPACE TO REMAIN
UNDISTURBED DURING
CONSTRUCTION OPERATIONS.
of
F
I /
L_
`\
4 \\
WIN-
EXISTING CMU DEMISING
WALL TO REMAIN.
3 7
EXI I A
P ER�
EMAIN UN
RB
1�1-�
A
�l
7
......
..........
g EXISTING ADJACENT TENANT SPACES ARE TO REMAIN
UNDISTURBED. G.C. TO PROVIDE NOISE, DUST CONTROLS
PER BUILDING MANAGER REQUIREMENTS. G.C. TO VERIFY
HOURS OF OPERATIONS AND ANY OTHER RESTRICTIONS
ON NORMAL CONSTRUCTION OPERATIONS PRIOR TO
COMMENCEMENT OF WORK.
9 EXISTING FIRE ALARM /FIRE PROTECTION TO REMAIN IN
WORKING ORDER TO THE GREATEST EXTENT POSSIBLE.
COORDINATE ANY INTERRUPTIONS IN FIRE FLOW OR
ALARM WITH BUILDING MANAGER.
WALL LEGEND
EXISTING 8" CMU EXTERIOR WALL.
TO REMAIN
EXISTING 1 -HR TENANT DEMISING
WALL TO REMAIN
EXISTING INTERIOR PARTITION
WALL TO REMAIN
EXISTING INTERIOR PARTITION
WALL TO BE REMOVED
'1rY Or SOU TH
L;3UdL,LM1 ,G DEP'r.
C3'IC91•J.
ED 9y
..Lro<V"
INTERIOR RENOVATION FOR:
!4A
MAN D & STONE Massage & Facial Spa
7301 SW 57th CT,, SUITE 170, SOUTH MIAMI, FL 33143
FORM GROUP, INC.
4300 5W 73 AVE, SUITE 106, MIAMI, FL 33155
TEL 305M3,4244 FX. 305.443 3338
CORPORATE LICENSE Na M•26000668
ARCHITECT OF RECORD, OMAR MORALES
ARCHITECT LICENSE Na AR- OW4851
THE ... FOHNAT. TCCHNIQUE AND OCOION —' 111E YROYE— OF k'ONM f:HOOY. 111.
NO PMT 1'IICR01 SHALL BE COPIED. ll CJBSEC OR OsCO 1{RUOIiT nTU Wanilcx CONSENT OF 1—
TITLE:
DEMO' PLAN
SCALE
1/4" = T -0"
PROJECT NO.
11.606
DATE
JUNE 3, 2011
REVISIONS
DRAWING NO--
D -1.0
}
W �
CENERAL QEMOLITION NOTES:
1
GENERAL CONTRACTOR SHALL CAP AND IDENTIFY
EXPOSED UTILITIES.
2
GENERAL CONTRACTOR TO PROVIDE PERMITS AND
NOTICES AUTHORIZING DEMO.
3
GENERAL CONTRACTOR TO PROVIDE PERMIT FOR
TRANSPORT AND DISPOSAL OF DEBRIS.
4
GENERAL CONTRACTOR SHALL SUBMIT A SCHEDULE FOR
DEMOLITION PROCEDURES AND OPERATIONAL SEQUENCE
FOR REVIEW AND AND ACCEPTANCE BY
ARCH I TECT /ENGINEER /OWN ER.
5
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR
SAFETY AND SUPPORT OF STRUCTURE. ASSUME
LIABILITY FOR DAMAGE OR INJURY RELATED TO ANY
PORTION OF THE WORK.
6
GENERAL CONTRACTOR SHALL CEASE OPERATIONS
OPERATIONS AND NOTIFY THE ARCHITECT / ENGINEER
IMMEDIATELY IF SAFETY OF STRUCTURE APPEARS TO BE
ENDANGERED. TAKE PRECAUTIONS TO PROPERLY
SUPPORT STRUCTURE. DO NOT RESUME OPERATION UNTIL
SAFETY IS RESTORED.
7
WORK AREAS TO BE MAINTAINED IN A CLEAN /SAFE AND
ORDERLY MANNER. ALL DEMOLITION DEBRIS SHOULD BE
1
REMOVED IMMEDIATELY.
g EXISTING ADJACENT TENANT SPACES ARE TO REMAIN
UNDISTURBED. G.C. TO PROVIDE NOISE, DUST CONTROLS
PER BUILDING MANAGER REQUIREMENTS. G.C. TO VERIFY
HOURS OF OPERATIONS AND ANY OTHER RESTRICTIONS
ON NORMAL CONSTRUCTION OPERATIONS PRIOR TO
COMMENCEMENT OF WORK.
9 EXISTING FIRE ALARM /FIRE PROTECTION TO REMAIN IN
WORKING ORDER TO THE GREATEST EXTENT POSSIBLE.
COORDINATE ANY INTERRUPTIONS IN FIRE FLOW OR
ALARM WITH BUILDING MANAGER.
WALL LEGEND
EXISTING 8" CMU EXTERIOR WALL.
TO REMAIN
EXISTING 1 -HR TENANT DEMISING
WALL TO REMAIN
EXISTING INTERIOR PARTITION
WALL TO REMAIN
EXISTING INTERIOR PARTITION
WALL TO BE REMOVED
'1rY Or SOU TH
L;3UdL,LM1 ,G DEP'r.
C3'IC91•J.
ED 9y
..Lro<V"
INTERIOR RENOVATION FOR:
!4A
MAN D & STONE Massage & Facial Spa
7301 SW 57th CT,, SUITE 170, SOUTH MIAMI, FL 33143
FORM GROUP, INC.
4300 5W 73 AVE, SUITE 106, MIAMI, FL 33155
TEL 305M3,4244 FX. 305.443 3338
CORPORATE LICENSE Na M•26000668
ARCHITECT OF RECORD, OMAR MORALES
ARCHITECT LICENSE Na AR- OW4851
THE ... FOHNAT. TCCHNIQUE AND OCOION —' 111E YROYE— OF k'ONM f:HOOY. 111.
NO PMT 1'IICR01 SHALL BE COPIED. ll CJBSEC OR OsCO 1{RUOIiT nTU Wanilcx CONSENT OF 1—
TITLE:
DEMO' PLAN
SCALE
1/4" = T -0"
PROJECT NO.
11.606
DATE
JUNE 3, 2011
REVISIONS
DRAWING NO--
D -1.0
}