11-715-004�- EXISTING BUILDING EXIT i STAIR AND CORIDOOR. SHOWN FOR REFERENCE ONLY 5TAIR NO2 GENERAL DEMOLITION LEGEND; 1❑ REMOVE GYPSUM WALL BOARD PARTITIONS INDICATED BY DASHED LINES. R2 REMOVE EXISTING DOORS, FRAMES & HARDWARE INDICATED BY DASHED LINES. EXISTING DOOR, FRAME & HARDWARE TO REMAIN. REMOVE ALL EXISTING WALL FINISHES, TILE, MOLDINGS, PREPARE SURFACE FOR NEW FINISH I ■I 5 F REMOVE EXISTING CARPET, GLUE DOWN VINYL TILE, OR MISC. FLOORING AND PREPARE SURFACE TO RECEIVE NEW FINISH. REMOVE EXISTING ANY CABINETRY OR OTHER MISCELLANEOUS MILLWORK ❑ 7 EXISTING STOREFRONT WINDOWS, FIXED WINDOWS AND FRAMES TO REMAIN. PROVIDE PROTECTION DURING CONSTRUCTION OPERATIONS. 88] REMOVE EXISTING CEILING TILE & GRID OR GYPSUM WALL BOARD CEILING AND SOFFITS WITHIN DEMO AREA. REMOVE EXISTING PLUMBING FIXTURES. CAP WATER, SANITARY, AND VENT LINES. 10 REMOVE EXISTING LIGHT FIXTURES THROUGHOUT ENTIRE AFFECTED DEMO AREA. 11 REMOVE ALL EXISTING H.V.A.C. SUPPLY & RETURN GRILLS, AND DUCTWORK WITHIN AFFECTED DEMO AREA. CAP AND SEAL ANY EXISTING H.V.A.C. ROOF PENETRATIONS, EXHAUST DUCTS, ETC. PER ROOF PATCH NOTES ON M -1. REFER TO MECHANICAL DRAWINGS FOR NEW DUCT LAYOUT. 12 REMOVE EXISTING CEILING FINISH PREPARE SURFACE FOR NEW FINISH. 13 EXISTING ELECTRICAL PANEL AND PARTITION TO REMAIN 14 CAP EXISTING FLOOR OUTLET. SEE ELECT DWGS FOR ADDITIONAL INFORMATION A DEMOLITION PLAN scale: 1/4 " =1' -0" EXISTING ADJACENT TENANT SPACE TO REMAIN UNDISTURBED DURING CONSTRUCTION OPERATIONS. of F I / L_ `\ 4 \\ WIN- EXISTING CMU DEMISING WALL TO REMAIN. 3 7 EXI I A P ER� EMAIN UN RB 1�1-� A �l 7 ...... .......... g EXISTING ADJACENT TENANT SPACES ARE TO REMAIN UNDISTURBED. G.C. TO PROVIDE NOISE, DUST CONTROLS PER BUILDING MANAGER REQUIREMENTS. G.C. TO VERIFY HOURS OF OPERATIONS AND ANY OTHER RESTRICTIONS ON NORMAL CONSTRUCTION OPERATIONS PRIOR TO COMMENCEMENT OF WORK. 9 EXISTING FIRE ALARM /FIRE PROTECTION TO REMAIN IN WORKING ORDER TO THE GREATEST EXTENT POSSIBLE. COORDINATE ANY INTERRUPTIONS IN FIRE FLOW OR ALARM WITH BUILDING MANAGER. WALL LEGEND EXISTING 8" CMU EXTERIOR WALL. TO REMAIN EXISTING 1 -HR TENANT DEMISING WALL TO REMAIN EXISTING INTERIOR PARTITION WALL TO REMAIN EXISTING INTERIOR PARTITION WALL TO BE REMOVED '1rY Or SOU TH L;3UdL,LM1 ,G DEP'r. C3'IC91•J. ED 9y ..Lro<V" INTERIOR RENOVATION FOR: !4A MAN D & STONE Massage & Facial Spa 7301 SW 57th CT,, SUITE 170, SOUTH MIAMI, FL 33143 FORM GROUP, INC. 4300 5W 73 AVE, SUITE 106, MIAMI, FL 33155 TEL 305M3,4244 FX. 305.443 3338 CORPORATE LICENSE Na M•26000668 ARCHITECT OF RECORD, OMAR MORALES ARCHITECT LICENSE Na AR- OW4851 THE ... FOHNAT. TCCHNIQUE AND OCOION —' 111E YROYE— OF k'ONM f:HOOY. 111. NO PMT 1'IICR01 SHALL BE COPIED. ll CJBSEC OR OsCO 1{RUOIiT nTU Wanilcx CONSENT OF 1— TITLE: DEMO' PLAN SCALE 1/4" = T -0" PROJECT NO. 11.606 DATE JUNE 3, 2011 REVISIONS DRAWING NO-- D -1.0 } W � CENERAL QEMOLITION NOTES: 1 GENERAL CONTRACTOR SHALL CAP AND IDENTIFY EXPOSED UTILITIES. 2 GENERAL CONTRACTOR TO PROVIDE PERMITS AND NOTICES AUTHORIZING DEMO. 3 GENERAL CONTRACTOR TO PROVIDE PERMIT FOR TRANSPORT AND DISPOSAL OF DEBRIS. 4 GENERAL CONTRACTOR SHALL SUBMIT A SCHEDULE FOR DEMOLITION PROCEDURES AND OPERATIONAL SEQUENCE FOR REVIEW AND AND ACCEPTANCE BY ARCH I TECT /ENGINEER /OWN ER. 5 GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY AND SUPPORT OF STRUCTURE. ASSUME LIABILITY FOR DAMAGE OR INJURY RELATED TO ANY PORTION OF THE WORK. 6 GENERAL CONTRACTOR SHALL CEASE OPERATIONS OPERATIONS AND NOTIFY THE ARCHITECT / ENGINEER IMMEDIATELY IF SAFETY OF STRUCTURE APPEARS TO BE ENDANGERED. TAKE PRECAUTIONS TO PROPERLY SUPPORT STRUCTURE. DO NOT RESUME OPERATION UNTIL SAFETY IS RESTORED. 7 WORK AREAS TO BE MAINTAINED IN A CLEAN /SAFE AND ORDERLY MANNER. ALL DEMOLITION DEBRIS SHOULD BE 1 REMOVED IMMEDIATELY. g EXISTING ADJACENT TENANT SPACES ARE TO REMAIN UNDISTURBED. G.C. TO PROVIDE NOISE, DUST CONTROLS PER BUILDING MANAGER REQUIREMENTS. G.C. TO VERIFY HOURS OF OPERATIONS AND ANY OTHER RESTRICTIONS ON NORMAL CONSTRUCTION OPERATIONS PRIOR TO COMMENCEMENT OF WORK. 9 EXISTING FIRE ALARM /FIRE PROTECTION TO REMAIN IN WORKING ORDER TO THE GREATEST EXTENT POSSIBLE. COORDINATE ANY INTERRUPTIONS IN FIRE FLOW OR ALARM WITH BUILDING MANAGER. WALL LEGEND EXISTING 8" CMU EXTERIOR WALL. TO REMAIN EXISTING 1 -HR TENANT DEMISING WALL TO REMAIN EXISTING INTERIOR PARTITION WALL TO REMAIN EXISTING INTERIOR PARTITION WALL TO BE REMOVED '1rY Or SOU TH L;3UdL,LM1 ,G DEP'r. C3'IC91•J. ED 9y ..Lro<V" INTERIOR RENOVATION FOR: !4A MAN D & STONE Massage & Facial Spa 7301 SW 57th CT,, SUITE 170, SOUTH MIAMI, FL 33143 FORM GROUP, INC. 4300 5W 73 AVE, SUITE 106, MIAMI, FL 33155 TEL 305M3,4244 FX. 305.443 3338 CORPORATE LICENSE Na M•26000668 ARCHITECT OF RECORD, OMAR MORALES ARCHITECT LICENSE Na AR- OW4851 THE ... FOHNAT. TCCHNIQUE AND OCOION —' 111E YROYE— OF k'ONM f:HOOY. 111. NO PMT 1'IICR01 SHALL BE COPIED. ll CJBSEC OR OsCO 1{RUOIiT nTU Wanilcx CONSENT OF 1— TITLE: DEMO' PLAN SCALE 1/4" = T -0" PROJECT NO. 11.606 DATE JUNE 3, 2011 REVISIONS DRAWING NO-- D -1.0 }