09-1100-00624" MAX. ARM OVER 24" MAX. ARM OVER LENTH PER NFPA 13 LENTH PER NFPA 13 1996 4- 14.2.3.4 1996 4- 14.2.3.4 I 71 (TYPICAL) NEW NEW 1" TEE Mwl I I I I II 4- 1 /4" TEE (MIN) 1" DROP --III I I I!— 1" DROP I 1 1" DROP EXISTING -1 L— EXISTING SPRINKLER I SPRINKLER SUPPLY SUPPLY BRANCH BRANCH CEILING -f T\ EILING 7\-NEW SEMI - RECESSED PENDANT SPRINKLER HEAD CENTERED IN CEILING TILE ANEW SEMI - RECESSED PENDANT SPRINKLER HEAD CENTERED IN CEILING TILE NEW HEAD INSTALLATION DETAIL NO SCALE INTERIOR RENOVATIONS TO NCB, Inc. SUITE 520, FIFTH FLOOR, PLAZA 57 7301 S.W. 57TH COURT SOUTH MIAMI, FLORIDA 33143 FIRE SPRIWLM NOTES: GENERA: A) THE FIRE SPRINKLER SYSTEM FOR THIS PROJECT IS TO BE PROCURED ON A DESIGN BUILD BASIS WITH THE SPRINKLER CONTRACTOR FULLY RESPONSIBLE FOR THE DETAILED DESIGN OF AND SHALL CON -ORM TO LOCAL CODE, DEVELOPER INSURANCE UNDERWRITER AND ALL PERTINENT STANDARDS OF NFPA. B) ORDER NEW WATER FLOW TEST FROM THE FIDE DEPARTMENT TO USE AS BASIS FOR DESIGN. C) COORDINATE WITH ALL OTHER TRADES BEFORE PREPARATION OF DESIGN DOCUMENTS. FOR SUBMITTAL AND PERMIT PURPOSES. 1) THE PROPOSED BUILDING SHALL BE FULLY SPRINKLERED IN COMPLIANCE WITH THE FOLLOWING: a. LOCAL AUTHORITY HAVING JURISDICTION. b. NFPA 13 - INSTALLATION OF SPRINKLER SYSTEMS c. NFPA 14 - NOT USED d. NFPA 20 - NOT USED e. NFPA 24 - PRIVATE FIRE SERVICE MAINS f. NFPA 101- LIFE SAFETY CODE g. THE FLORIDA BUILDING CODE - 2000 K THE FLORIDA FIRE PREVENTION CODE 1. ALL OTHER APPLICABLE CODES AND STANDARDS. 2) PROVIDE A WET PIPE SPRINKLER SYSTEM, ALTERNATIVELY FED FROM THE FIRE STANDPIPES AND PUMP SYSTEM. 3) PREPARE FULLY DIMENSIONED AND COORDINATED SPRINKLER AND FIRE STANDPIPE SHOP DRAWINGS IN ACCORDANCE WITH THE REQUIREMENT OF THIS BUILDING AND ALL APPLICABLE CODES AND STANDARDS. SHOP DRAWINGS SHALL BE PREPARED BY A LICENSED SPRINKLER CONTRACTOR AND SIGNED AND SEALED BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER, TOGETHER WITH THE HYDRAULIC CALCULATIONS. 4) SPRINKLER SYSTEM LAYOUT, AND HYDRAULIC CALCULATIONS SHALL BE PREPARED IN ACCORDANCE WITH THE FOLLOWING NFPA 13 HAZARD CLASSIFICATIONS: a. CORRIDORS 4 TOILET AREAS - ORDINARY HAZARD GROUP 211 -412) b. OFFICE SPACES - LIGHT HAZARD (1 -412) c. LOBBY AREAS - ORDINARY HAZARD (1 -13.1) d) ALL EXPOSED PIPING SHALL BE SCH. 40 - GALVANIZED STEELSTEEL. e) PROVIDE CORROSION RESISTANCE TREATMENT TO SPRINKLER HEADS EXPOSED TO WEATHER ALL NON AIR CONDITIONED AREAS ARE TO BE CONSIDERED EXPOSED TO WEATHER 5) PIPING SHALL BE IN ACCORDANCE WITH SECTION 2 -3, NFPA 13, 1999 EDITION. AND AS FOLLOWS. a) GENERAL DISTRIBUTION -SCH. 40 -BLACK STEEL. W/THREADED JOINTS. b) UNDERGROUND SERVICE PIPE FROM MAIN TO RISER -4' D.I.P. c) RISER - SCH. 10 - 4' BLACK STEEL W/ VICTAULIC FITTINGS. GENERAL DISTRIBUTION - d) FIRE SPRINKLER CONTROL VALVES TO BE OF THE PRESSURE RESTRICTIVE TYPE WHERE PRESSURE EXCEEDS 115 PrS.I�G. (o) INSTALL HANGERS IN ACCORDANCE WITH CHAPTER (o, NFPA 13, ISS5 EDITION. HANGER TO BE MANUFATURED BY ERICO CO. 1) PROTECT ELEVATORS IN ACCORDANCE WITH STATE FIRE MARSHALL'S UNIFORM SAFETY RULES, CHAPTER 4A -41. ELECTRICAL AND ELEVATOR CONTRACTORS MUST COMPLY WITH THESE REQUIREMENTS. S) PROVIDE SPARE SPRINKLER CABINET IN ACCORD WITH NFPA 13 PROVIDE A MINIMUM OF (o SPARE HEADS OF EACH TYPE, SIZE AND RATING USED. (NOT LESS THAN 24 TOTAL) PROVIDE SPECIAL SPRINKLER WRENCHES IN THE CABINET. LOCATE CABINET IN APPROVED LOCATION. S) INSTALL FIRE SPRINKLER HEADS IN THE CENTER OF THE CEILING TILES. 10) THE INSTALLATION OF H Y.A.C. AND PLUMBING HAS PRECEDENCE OVER FIRE PROTECTION. THE FIRE SPRINKLER CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL CONTRACTOR TO ALLOW ALL DUCTWORK TO BE INSTALLED AS HIGH AS POSSIBLE. 11) COORDINATE WITH ELECTRICAL CONTRACTOR FOR ANY CONFLICTS OF SPRINKLER HEADS AND LIGHT FIXTURES, SEE ELECTRICAL PLANS PLAN KEYED NOTES 10 CONNECT NEW SEMIRECESSED SPRINKLER HEAD TO PHILLIPS CONCRETE EXISTING FIRE PROTECTION WATER PIPE SYSTEM. 2' 1 — EXIST. FIRE S INKL Rg MAIN AS PER FASTENER OR EQUAL 2 ---- -t NEW FIRE SPRINKLER BRANCH r r r r LOCATE M CENTER OF TILE — — 0'sx DENOTES EXISTING PENDANT SPRINKLER HEAD - - -- TO REMAIN 11� V. DENOTES RELOCATED PENDANT HEAD LOCATE r r m MINIMUM DISTANCE = 1' 0 DENOTES EXIST. PENDANT TO REMAIN _ _ - TOTAL NO.OF HEADS NEW RELOCATED REMAIN REMOVED = CONCRETE m 11 0 = CONSTRUCTION ORIGINAL DESIGN CRITERIA: L HYDRAULIC DESIGN CRITERIA: C. OFFICES 4 GENERAL CORRIDOR 4 TOILET AREAS NFPA HAZARD CLASSIFICATION - - -- OH - 2 ALL THREAD ROD DESIGN DENSITY ---------- - - - - -- OJO GPM/SF DESIGN COVERAGE PER HEAD - - -- 130 SF. MAXIMNI. MAXIMUM HEAD SPACING --- - - - - -- 5 FT. FIRE SPRINKLER LEGEND OFFICES AREAS COMMON AREAS. OFFICES, ETC. 0 CENTRAL MODEL TY -B (QUICK RESPONSE) 165TF - K ■5b 1/2' ORIFICE. PROVIDE CLEVIS TYPE HANGER APPROVED BY SWIVEL RING CONTRACTOR SHALL NOTIFY MOAD 1 WORKING DAYS BEFORE A SHUT DOWN WILL OCCUR FOR INSTALLATION OF NEW HEADS OR LINES. SWIVEL RING TAKE -OUT U ' PIPE HANGER DETAIL - DROP -IN ANCHOR N.T.S. PIPE ROD TYPE OF MIN "C" MAX "D" SIZE SIZE FASTENER DIM. DIM. 3/4 1/2 , 1 5/81 1 5/8, 1 3/41 3�8 1 -3is' x 1 11/32' 114 13/16' 1 Tj81 DROP- IN ANCHOR 11,21 15/16' 2' 21 1 3/16' 2 3i8' 21/21 1/2 , 1 -1/2' x 1 15/32 1 -1/l�0' 2 3/41 3' 1 3/41 3 1/41 DROP- IN ANCHOR 312 2 1 3 5/1 4' 5/8 1 -5 /s' x 2 15/32' DROP-IN ANCHOR 2 1/4' 311/1 8 51 2 3/41 4 3/4 1 (0' 3/4' 1- 3/4'X3 1/4' DROP-IN ANCH. 35/1(01 5 1/21 6' N/A N/A N/A N/A INTERIOR RENOVATIONS TO NCB, Inc. SUITE 520, FIFTH FLOOR, PLAZA 57 7301 S.W. 57TH COURT SOUTH MIAMI, FLORIDA 33143 FIRE SPRIWLM NOTES: GENERA: A) THE FIRE SPRINKLER SYSTEM FOR THIS PROJECT IS TO BE PROCURED ON A DESIGN BUILD BASIS WITH THE SPRINKLER CONTRACTOR FULLY RESPONSIBLE FOR THE DETAILED DESIGN OF AND SHALL CON -ORM TO LOCAL CODE, DEVELOPER INSURANCE UNDERWRITER AND ALL PERTINENT STANDARDS OF NFPA. B) ORDER NEW WATER FLOW TEST FROM THE FIDE DEPARTMENT TO USE AS BASIS FOR DESIGN. C) COORDINATE WITH ALL OTHER TRADES BEFORE PREPARATION OF DESIGN DOCUMENTS. FOR SUBMITTAL AND PERMIT PURPOSES. 1) THE PROPOSED BUILDING SHALL BE FULLY SPRINKLERED IN COMPLIANCE WITH THE FOLLOWING: a. LOCAL AUTHORITY HAVING JURISDICTION. b. NFPA 13 - INSTALLATION OF SPRINKLER SYSTEMS c. NFPA 14 - NOT USED d. NFPA 20 - NOT USED e. NFPA 24 - PRIVATE FIRE SERVICE MAINS f. NFPA 101- LIFE SAFETY CODE g. THE FLORIDA BUILDING CODE - 2000 K THE FLORIDA FIRE PREVENTION CODE 1. ALL OTHER APPLICABLE CODES AND STANDARDS. 2) PROVIDE A WET PIPE SPRINKLER SYSTEM, ALTERNATIVELY FED FROM THE FIRE STANDPIPES AND PUMP SYSTEM. 3) PREPARE FULLY DIMENSIONED AND COORDINATED SPRINKLER AND FIRE STANDPIPE SHOP DRAWINGS IN ACCORDANCE WITH THE REQUIREMENT OF THIS BUILDING AND ALL APPLICABLE CODES AND STANDARDS. SHOP DRAWINGS SHALL BE PREPARED BY A LICENSED SPRINKLER CONTRACTOR AND SIGNED AND SEALED BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER, TOGETHER WITH THE HYDRAULIC CALCULATIONS. 4) SPRINKLER SYSTEM LAYOUT, AND HYDRAULIC CALCULATIONS SHALL BE PREPARED IN ACCORDANCE WITH THE FOLLOWING NFPA 13 HAZARD CLASSIFICATIONS: a. CORRIDORS 4 TOILET AREAS - ORDINARY HAZARD GROUP 211 -412) b. OFFICE SPACES - LIGHT HAZARD (1 -412) c. LOBBY AREAS - ORDINARY HAZARD (1 -13.1) d) ALL EXPOSED PIPING SHALL BE SCH. 40 - GALVANIZED STEELSTEEL. e) PROVIDE CORROSION RESISTANCE TREATMENT TO SPRINKLER HEADS EXPOSED TO WEATHER ALL NON AIR CONDITIONED AREAS ARE TO BE CONSIDERED EXPOSED TO WEATHER 5) PIPING SHALL BE IN ACCORDANCE WITH SECTION 2 -3, NFPA 13, 1999 EDITION. AND AS FOLLOWS. a) GENERAL DISTRIBUTION -SCH. 40 -BLACK STEEL. W/THREADED JOINTS. b) UNDERGROUND SERVICE PIPE FROM MAIN TO RISER -4' D.I.P. c) RISER - SCH. 10 - 4' BLACK STEEL W/ VICTAULIC FITTINGS. GENERAL DISTRIBUTION - d) FIRE SPRINKLER CONTROL VALVES TO BE OF THE PRESSURE RESTRICTIVE TYPE WHERE PRESSURE EXCEEDS 115 PrS.I�G. (o) INSTALL HANGERS IN ACCORDANCE WITH CHAPTER (o, NFPA 13, ISS5 EDITION. HANGER TO BE MANUFATURED BY ERICO CO. 1) PROTECT ELEVATORS IN ACCORDANCE WITH STATE FIRE MARSHALL'S UNIFORM SAFETY RULES, CHAPTER 4A -41. ELECTRICAL AND ELEVATOR CONTRACTORS MUST COMPLY WITH THESE REQUIREMENTS. S) PROVIDE SPARE SPRINKLER CABINET IN ACCORD WITH NFPA 13 PROVIDE A MINIMUM OF (o SPARE HEADS OF EACH TYPE, SIZE AND RATING USED. (NOT LESS THAN 24 TOTAL) PROVIDE SPECIAL SPRINKLER WRENCHES IN THE CABINET. LOCATE CABINET IN APPROVED LOCATION. S) INSTALL FIRE SPRINKLER HEADS IN THE CENTER OF THE CEILING TILES. 10) THE INSTALLATION OF H Y.A.C. AND PLUMBING HAS PRECEDENCE OVER FIRE PROTECTION. THE FIRE SPRINKLER CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL CONTRACTOR TO ALLOW ALL DUCTWORK TO BE INSTALLED AS HIGH AS POSSIBLE. 11) COORDINATE WITH ELECTRICAL CONTRACTOR FOR ANY CONFLICTS OF SPRINKLER HEADS AND LIGHT FIXTURES, SEE ELECTRICAL PLANS PLAN KEYED NOTES 10 CONNECT NEW SEMIRECESSED SPRINKLER HEAD TO Q EXISTING FIRE PROTECTION WATER PIPE SYSTEM. 2' 1 — EXIST. FIRE S INKL Rg MAIN AS PER 2 ---- -t NEW FIRE SPRINKLER BRANCH ON DENOTES NEW PENDANT SPRINKLER HEAD LOCATE M CENTER OF TILE — — 0'sx DENOTES EXISTING PENDANT SPRINKLER HEAD - - -- TO REMAIN 11� V. DENOTES RELOCATED PENDANT HEAD LOCATE R AT CENTER OF TILE. ROVIDE IN DROP MIN. 0 DENOTES EXIST. PENDANT TO REMAIN _ _ - TOTAL NO.OF HEADS NEW RELOCATED REMAIN REMOVED PENDANTS 3 m 11 0 TOTAL NO. OF HEADS 10 AVERAGE COVERAGE PROVIDED M Sa FT. PER HEAD ORIGINAL DESIGN CRITERIA: L HYDRAULIC DESIGN CRITERIA: C. OFFICES 4 GENERAL CORRIDOR 4 TOILET AREAS NFPA HAZARD CLASSIFICATION - - -- OH - 2 DESIGN AREA OF APPLICATION - - -- 15W SF. DESIGN DENSITY ---------- - - - - -- OJO GPM/SF DESIGN COVERAGE PER HEAD - - -- 130 SF. MAXIMNI. MAXIMUM HEAD SPACING --- - - - - -- 5 FT. FIRE SPRINKLER LEGEND OFFICES AREAS COMMON AREAS. OFFICES, ETC. UPRIGHT OR PENDANT SPRINKLER HEAD. CENTRAL MODEL TY -B (QUICK RESPONSE) 165TF - K ■5b 1/2' ORIFICE. PROVIDE CLEVIS TYPE HANGER APPROVED BY UPRIGHT OR PENDANT SPRINKLER HEAD. FIRE SPRWLER CONSTRUCTION NOTES CONTRACTOR SHALL NOTIFY MOAD 1 WORKING DAYS BEFORE A SHUT DOWN WILL OCCUR FOR INSTALLATION OF NEW HEADS OR LINES. T1 F j: �q 0 t�PEF � ANTONIO FRANYIE PE #11640 MECH VIVIANA FRANYIE PE #49985 ME �'j w, 4M �U'NW 27 Street, Miami FL 33172 TEL: (30 821* FAX: (305) 594 -9279 www. path ` lieien ineers.com DESIG ' ' W "ATE JOB NUMBER 04 -214 Q Q Q I p— — — i — 9--- - - I - - -- 11� I ° - - - -- _ _ - 11 XA I- -- - - - --- c o-- i i CHANDLER AND ASSOCIATES PA AA 00011M 7ASON R CEIAIMM AR Na I601S6 SOUM MTAK FLORIDA 33143 MM = 681 -7992 FAX (30b) 668 -7993 WWW.CHANDIERARCETrECrURECOM cow = NO. DATE 4 U ell V t,k EXISTIMCs FIRE SPRINKLER LAYOUT. SEE SHELL PERMIT SE' 05 ------------------------- -------------------------- --- -------- coveter wmf TEIWAM O---------- ��------------------------------------------------------------ - - - - -- �o F 's_ OFFICE PLAN - SUITE 524 NORM SCALE: ua' ■1' -m' ..1T,>Isa I I I I — — -- -- - - - - -- -- - - - - -- -------- ----------- I - - - -- ---® I I I I I I I I I — —�> I j 5UILDING KEY PLAN, FEVEM I NO. DATE FEVI" i A -a nn DRAWING TRIZ { r + PARMAL PL�IV WINE 520 SCALE. SEE PAGE ` DATES PROJECT NOS 2009.6 TT \ \rte I� !_� LLl � L. FP -1 f �T