09-1046-014N 8 N N o in N in rIn Ln a N M N 0 Q N 0 0 a a- CIMLRA - ON A DESIGN BUILD A) THE FIRE SPRINKLER SYSTEM FOR THIS PROJECT IS TO BE PROCURED BASIS WITH THE SPROKLER CONTRACTOR FULLY RESPONSIBLE FOR THE DETAILED DESIGN OF AND SHALL COQ TO LOCAL CODE, DEVELOPER INSURANCE UNDERWRITER AND ALL PERTINENT STANDARDS OF NFPA 5) ORDER NEW WATER FLOW TEST FROM THE FIRE DEPARTMENT TO USE AS BASIS FOR DESIGN. C) COORDINATE WITH ALL OTHER TRADES BEFORE PREPARATION OF DESIGN DOCUMENTS. FOR SUBMITTAL AND PERMIT PURPOSES. 1) THE PROPOSED BUILDING SHALL 5E FULLY SPRINKLED IN COMPLIANCE WITH THE FOLLOWING: a. LOCAL AUTHORITY HAVING JURISDICTION. b. NFPA 13 - INSTALLATION OF SPRINKLER SYSTEMS c. NFPA 14 - NOT USED d. NFPA 20 - NOT USED e. NFPA 24 - PRIVATE FIRE SERVICE MAINS f. NFPA 101- LIFE SAFETY CODE g. THE FLORIDA BUILDING CODE - 2000 h THE FLORIDA FIRE PREVENTION CODE i. ALL OTHER APPLICABLE CODES AND STANDARDS. 2) PROVIDE A WET PIPE SPRINKLER SYSTEM, ALTERNATIVELY FED FROM THE FIRE STANDPIPES AND PUMP SYSTEM' 3) PREPARE FULLY DIMENSIONED AND COORDINATED SPRINKLER AND FIRE STANDPIPE SHOP DRAWIW_6 IN ACCORDANCE WITH THE REQUIREh1ENT OF THIS 5UILDING AND ALL APPLICABLE CODES AND STANDARDS. SHOP DRAUJINGS SHALL 5E PREPARED BY A LICENSED SPRINKLER CONTRACTOR AND SIGNED AND SEALED 5Y A FLORIDA REGISTERED PROFESSIONAL ENGINEER, TOGETHER WITH THE HYDRAULIC CALCULATIONS. 4) SPRINKLER SYSTEM LAYOUT, AND HYDRAULIC CALCULATIONS SHALL ANCE WITH THE FOLLO 5E PREPARED IN ACCORDWING NFPA 13 HAZARD CLASSIFICATIONS: a. CORRIDORS 4 TOILET AREAS - ORDINARY HAZARD GROUP 2.(1 -412) b. OFFICE SPACES - LIGHT HAZARD (1 -4.12) c. L055Y AREAS - ORDINARY HAZARD (1 -131) d) ALL EXPOSED PIPING SHALL 5E SCH. 40 - GALVANIZED STEELSTEEL. e) PROVIDE CORROSION RESISTANCE TREATMENT TO SPRINKLER HEADS EXPOSED TO WEATHER ALL NON AIR CONDITIONED AREAS ARE TO 5E CONSIDERED EXPOSED TO WEATHER 5) ACCORDANCE WITH SECTION 2 -3, NFPA 13,1(399 EDITION. AND AS FOLLOWS a) GENERAL DISTRIBUTION -SCH. 40 ADED DINTS EL. b) UNDERCIRCIUND SERVICE PIPE FROM MAIN TO RISER -4' D.I.P. c) RISER - SCH. 10 - 4' BLACK STEEL W/ ACTAULIC FITTINGS. GENE=RAL DISTRIBUTION - d) FIRE SPRINKLER CONTROL VALVES TO 5E OF THE PRESSURE RESTRICTIVE TYPE WHERE PRESSURE EXCEEDS 115 PaS.I G. (o) INSTALL HANGERS IN ACCORDANCE WITH CHAPTER (0, NFPA 13, 1999 EDITION. HANGER TO 13E MANUFATURED 5Y ERICO CO. 1) PROTECT ELEVATORS IN ACCORDANCE WITH STATE FIRE MARSHALL'S LNIFOIRM SAFETY CONTRACTORS MUST ESCOMPL.Y�WITH4THE5E REG3.I�IREMENTS� ELEVATOR 5) PROVIDE SPARE 5PRINKLER CA5INET IN ACCORD WITH NFPA 13 PROVIDE A MINIMUM OF b SPARE HEADS OF EACH TYPE, SIZE AND RATING USED. (NOT LE55 THAN 24 TOTAL) SATE CA�51N)! T INIAPPIPRROVED LOCA ION. THE CABINET. 9) INSTALL FIRE SPRINKLER HEADS IN THE CENTER OF THE CEILING TILES. 10) THE INSTALLATION OF H.VA.C. AND PLUMBING HAS PRECEDENCE OVER FIRE PROTECTION. THE FIRE SPRINKLER CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL CONTRACTOR TO ALLOW ALL DUCTWORK TO BE INSTALLED AS HIGH A5 POSSIBLE. ii) COORDINATE LE HEADS ELECTIRICAL CONTRACTOR LIGHT FIXTURES, SEE �CTR ELECTRICAL SPRINKLER PHILLIPS CONCRETE FASTENER OR EQUAL r ; r CO MINIMUM DISTANCE 1" ....... r r" CONCRETE CONSTRUCTION z I ALL THREAD ROD SWIVEL RING SWIVEL RING TAKE -OUT U PIPE HANGER DETAIL - DROP -IN ANCHOR N.T.S. PIPE SiZE ROD SIZE TYPE OF FASTENER MIN "C" DIM. MAX "D" DIM. x 1 11/32' pPOP- iN ANCHOR 1 -1/2' x 1 15/32' DROP- IN ANCHOR i/2 5/8, 13/16" 15/16' 1 3/16" 11/16" 1 3/411 1 3/411 1 1/a11 2" 2 3/a9 23/411 3 1/411 / ' 34 3 /a" 1 " 11/411 11/2 A 2,t 2 i 2 / n 1/2 " 3" 211 3 5/8 A L40 1 -'' /a' x 2 15/32' DROP- IN ANCHOR 2 I/ 4 A 2 3/411 A 7/ A 3 8 4 3/41 - 5/811 5 A 1- 3/4'x3 1/4' DROP - IN ANCH. 3 5/1611 5 1,211 3/4 ° 6 A N/A N/A N/A N/A 10614 Street, Mia i L 33 2 1360 FAX:305f 594- _ 1 I t 24" MAX. ARM^ OVER 24" MAX. ARM OVER -7 LENTH PER NFPA 133_ 1996 4- 14.2.3.4 LENTH PER NFPA 13 I I1996 4- 14.2.3.4 (TYPICAL) I I I NEW NEW �— 1 1/4" TEE (MIN) I1" TEE (MNI I I 1 DROP _ I I — 1 " DROP I 1 DROP -�- I�-- EXISTING EXISTING -I SPRINKLER SUPPLY SPRINKLER BRANCH! SUPPLY BRANCH I I ICEILING CEILING 7\—NEW SEMI — RECESSED I PENDANT SPRINKLER HEAD I I CENTERED IN CEILING TILE EW SEMI — RECESSED I PENDANT SPRINKLER HEAD ICENTERED IN CEILING TILE NEW HEAD INSTALLATION DETAIL INO SCALE TOTAL NO. OF H, FADS NEW MOCATED REMAIN REMOVED PENDANTS S 24 1i 0 SIDEWALL TOTAL NO. OF HEADS of AVERAGE COVERAGE PROVIDED 11 5GL FT. PER HEAD orzICSIN& gE51t;W CRITEk& L HYDRAULIC DESIGN CRITERIA: C. OFFICES 4 GENERAL CORRIDOR 4 TOILET AREAS NFPA HAZARD CLASSIFICATION - - -- OH - 2 DESIGN AIEA OF APPLICATION - - -- iA00 SF. DESIGN DENSITY ---------- - - - - -- 0.10 GPM/5F DESIGN COVERAGE PER HEAD - - -- 130 5F. MAXIMUM, MAXIMUM HEAD SPACING --- - - - - -- 15 FT, HRE Sfzj J LER LEGEND, OFFICES AREAS COMMON AREAS OFFICES, ETC. UPRIGHT OR PENDANT SPRINKLER HEAD, CENTRAL MODEL TY -5 (QUICK RESPONSE) 165 °F — K =5.6 1/2' ORIFICE. PROVIDE CLEVIS TYPE HANGER APPROVED 5Y UPRIGHT OR PENDANT SPRINKLER HEAD. tl,RE „ IWIM CONSTRUCTION NOTE$ CONTRACTOR SHALL NOTIFY MDAD 1 WORKING DAYS 5EFORE A SHUT DOWN WILL OCCUR FOR INSTALLATION OF NEW HEADS OR LINES. • ED NOM t�I CONNECT NEW SEMIRECE55ED SPRINKLER HEAD To,, EXISTING FIRE PROTECTION WATER pip E;SYS„ M 2' EXIST. FIRE SPR ER MAINaAS PER REFERENCED A55UIL �-- -{ NEW FIRE PR1 *1 LE'R:0RANCH ' =3 Q DENOTES NEW PENDANT SPRINKLER HEAD NEW DENOTES EXISTING HEAD TO 5E RELOCATED (D DENOTES OR REMOVED TO A NEW LOCATION. 0 RM EXIST TO REMAIN. Q DENOTES EXIST. PENDANT HEAD TO 5E p REMOVED CAP. MAY 5E RELOCATED TO NEW. Y ?h y1fpF, 1 4, �g R FIRE F SCALE: I/S' =1' -0' TECTION OFPIC FIFTH LEVEL 5UILDING PLAN AN -SUITE r • R C H I T E C T U n Fi 4565 PO :ICC OE LEON SUITE 201 COOL Gh.BLES ' L 33146 TEL 305 7R4 ?670 FAX 301789 2872 ARCHITECTURE LICENSE REGISTRATION NUMBERS CARLOS PRIO TOUZET FL AR0094099; JACQUELINE GONZALEZ FL AR0016319 Drawings are subject to modification or change as required by applicable building eats, standard d the (industry practices in light of existing structural and other conditions, app -< ; plans areyand shall remain the property of Touzet Studio, and shall not be sold or reproduced without It's prior written consent. Touiet Studio shall be notified of any changes required by actual conditions as aforesaid . prior to submission of any phase for construction. ©2009, TOUZBT STUDIO. h ,r OWNER � ..... .. NG HOLDINGS, LL( °rta MECHANICAL ELECTRICAL PLUMBING FIRE PROTECTION ENGINEERS b FRANYIE ENGINEERS, INC. ANTONIO FRANYIE PE #11640 VIVIANNA FRANYIE PE 449985 10610 NW 27th AVENUE MIAMI, FLORIDA 33172 305.592.1360 I ........................ , PROFESSIONAL LICENSE 525 ISSUE N0. DESCRIPTION ISSUE DATE PERMIT SET 11.04.09 'aH I— �-7 - -3— —�J I I IB 1 �I I -I t Ill � I I I IOFFICE SUITE 545 p OFFICE SUITE 555 OFFICE SUITE 565 I'I OFFICE SUITE 510 yl .i (III �I i= I I« viii ri I lam- 1 ��. .... i� ---`�I ;,I Pi Li I oFFiCE SUITE 550, $ ' OFFICE SURE 560 � ICE SUITE 540 it I 11 -12 -09 PERMIT SET r�t� Je 6 INTERIOR OFFICE REMODELING 7301 SW 57th COURT yi SPACE #525�� r SOUTH MIAMI, FLORIDA 33143 DRAWING TITLE rt'�, +4b w. RE PROTECTION FL06R PLC 4 ANTO "'° FRANYIE 3 PE #11640 MECH DETAILS &NOTES 17 r MA �998�5 MME C Certificate of . . . . . . .�. ' Authorization # 00002906" SCALE DRAWL ;NO. a� 10614 Street, Mia i L 33 2 1360 FAX:305f 594- EEL ww ( ,_ � n�, en�lne: �r 1,�itN DAT E ' AS NOTED • FS, 101 xx ` , a U BER G, JOB N M —XXX ifa a� I � ,e t,t KEY PLANn ... ci S" �t I> y i I FOR", sLZ DAI x kM` PROJECT PROJECT NO.: 09015 INTERIOR OFFICE REMODELING 7301 SW 57th COURT yi SPACE #525�� r SOUTH MIAMI, FLORIDA 33143 DRAWING TITLE rt'�, +4b w. RE PROTECTION FL06R PLC 4 ANTO "'° FRANYIE 3 PE #11640 MECH DETAILS &NOTES 17 r MA �998�5 MME C Certificate of . . . . . . .�. ' Authorization # 00002906" SCALE DRAWL ;NO. 10614 Street, Mia i L 33 2 1360 FAX:305f 594- EEL ww ( ,_ � n�, en�lne: DESK 1,�itN DAT E ' AS NOTED • FS, 101 xx ` , a U BER G, JOB N M —XXX ifa a� ,e t,t ci S" �t i