Loading...
09-1046-013"" "✓.SHEET NL ROUND VSITION SQUARE ROUND )VIDE INSULATION BLANKET VAPOR BARRIER OVER 3AR CLG. AND LIGHT 'URES WHEN NEXT TO , USSER. FERN CONTROLLER AIR DISTRIBUTION EDULE UL AR INSULATED PLENUM / ..,�J CPLENUM---/ NG DIFFUSER SEE AIR DISTRIBUTION SCHEDULE DIFFUSER & CONNECTOR DETAIL N.T.S. PHILLIPS CONCRETE FASTENER OR EQUAL ..-- -- HANGER ROD - SIZE 4 SPACINIG PER SMACNA GALV. THRU BOLT 0 ,�— STRAP HANGER LOW VELOCITY GALVANIZED ROUND SHEET METAL DUCT ROUND DUCT HANGING DETAIL NTISTS 11/2' x 22 GA. METAL STRAP AROUND DUCT A/C SPLIT SYSTEM SCHEDULE DESIGNATION EXIST. AHU -1 NO QUANTITY 1 SUPPLY AREA SCRVED SUITE 525 CONSTRUCTION MANUFACTURER TRANS ALUMINIUM FAN COIL MODEL No. T 0(03 - CONDENSING UNIT MODEL No. 2TTFU060 - C 0 E1 1 N E D R A T I N G S TOTAL SENSIBLE CAPACITY BTU HR 61000 GRAND TOTAL CAPACITY BTU HR 45100 24' x 24' MODULAR TOTAL HEATING CAPACITY BTU/HR 25,500 - ENERGY EFFICIENCY RATIO SEER (EER) 12.0 CEILING DIFFlJSER. DIFFUSER COEFFICIENT OF PERFORMANCE COP ECG CRATE FINISH F A N N C O I L U N I T TYPE VERTICAL MOUNTING TYPE TOTAL AIR SUPPLY CFM 2,000 T - BAR OUTSIDE AIR SUPPLY CFM 200 30 MAX ENTERING AIR CONDITIONS FDB FWB 80/67 METALAIRE EVAPORATOR COIL MIN. ROWS MAX. F.P.I. - MODEL EXTERNAL STATIC PRESSURE "H20 05 CC5 -1 FAN SPEED RPM HIGH SPEED 051D FAN MOTOR HP 3/4 FIRE DAMPER ELECTRICAL SERVICE AVAILABLE 1 20811160 RUNNING LOAD AMPS 3.9 ELECTRIC RESISTANCE HEATER SIZE KW j 1.5 UNIT WEIGHT 225 C 0 N D E N S I N G U N I T TYPE AIR COOLED LOCATION ROOF REFRIGERANT TYPE R-22 AMBIENT AIR TEMPERATURE FDB 95T_ NUMBER OF COMPRESSORS 1 NUMBER OF REFRIGERANT CIRCUITS 1 CAPACITY REDUCTION STEPS % 0 -100 ELECTRICAL SERVICE AVAILABLE 20811160 RUNNING LOAD AMPS 24.0 MINIMUM CIRCUIT AMPS 38.0 MAXIMUM FUSE SIZE AMPS 60.0 UNIT WEIGHT 212 A C C E S S O R1 E S REFRIGERANT PIPING LENGHT FT. LIQUID LINE TYPE O.D. - SUCTION LINE SIZE O.D. THERMOSTAT HEAT /COOL FILTER SECTION AND FILTER TYPE 1'1/2' THROWAWAY SMOKE DETECTOR IN SUPPLY V I B R A T 1 0 1 S 0 L A T 0 R S FOR FAN COIL UNIT - FOR CONDENSING UNIT - A U T 0 A T I C C O N T R 0 L S TYPE - DESCRIPTION - OUTSIDE AIR CALCULATIONS AIR DISTRIBUTION SCHEDULE DESIGNATION YES NO Remarks USE SUPPLY SUPPLY RETURN CONSTRUCTION ALUMINIUM ALUMINIUM ALUMINIUM CAPACITY (C.F.M.) SHOWN ON PLANS - - FIRE RATED ENCLOSURE - SIZE SHOWN ON PLANS FIRE RATED ROOF/FLOOR CEILING ASSEMBLY TYPE 24' x 24' MODULAR - - - SMOKE CONTROL COMMENTS o CEILING DIFFlJSER. DIFFUSER SIDEWALL REG15TER ECG CRATE FINISH ALL ALUMINIUM ALL ALUMINIUM ALL ALUMINIUM MOUNTING TYPE T - BAR DUCT T - BAR NOISE CRITERIA 30 MAX 30 MAX 30 MAX MANUFACTURER METALAIRE METALAIRE METALAIRE MODEL 5500 V4004 CC5 -1 A C C E S S O R I E S OPPOSED BLADE REGIST. 051D 051 - FIRE DAMPER CONNECTION SIZE SHOWN ON PLANS NOTES : 1. FINISHES AND TYPES OF MOUNTS SHALL BE COORDINATED WITH ARCHITECTURAL DRAWINGS. 2. PROVIDE SINGLE THICKNESS TURNING VANES AT ALL 900 RECTANGULAR ELBOWS AND DOUBLE THICKNESS TURNING VANES AT ALL 900 SQUARE ELBOWS, OR 3 PIECE ELBOWS, 3. PROVIDE VOLUME EXTRACTORS BEHIND EACH SUPPLY OUTLET AND AT EACH DUCT BRANCH SUPPLY OUTLETS MODEL — OBDC. DUCT BRANCH TAKE —OFF MODEL — AIRTROL MOD. 102 4. PROVIDE O.B. DAMPER AT ALL SUPPLY OUTLETS. 5. DUCT WORK TYPE SEE A/C NOTES. 6. AIR PATTERN AND DIFFUSOR FACE SHOWN ON PLANS. 7. DIFFUSOR NECK SIZE SHOWN ON PLANS. (6x6, 90, 12x12, OR 15x15) HVAC DESIGN REQUIRES; w YES NO Remarks DUCT SMOKE DETECTOR I/ ;, n en - FIRE DAMPER(5) - - SMOKE DAMPER(S) - - - FIRE RATED ENCLOSURE - - - FIRE RATED ROOF/FLOOR CEILING ASSEMBLY FIRE STOPPING - - - SMOKE CONTROL - - - 11 -12 -0' PERMIT SE 009. " 0 i! { ANTONIO FRANYIE -A PE 111640 MECH PE 49985 MME JOB NUMBER 09 -xxx Rry 4565 PONCE DE LEON SUITE 101 'CORAL GABJS FL 33146 TEL 305 7G9 2873 FAY 305 X89 2872 ARCHITECTURE LICENSE REGISTRATION NUMBERS CARLOS PRIO TOUZET FL AR0094099; JACQUELINE GONZALEZ FL AR0016319 .................. ............................... Drawings are subject to modification or change as required by actual measurements, standard Industry practices In light of existing structural and other conditions, applicable building codes, and the like. These plans are and shall remain the property of Touzet Studio and shall not be sold or reproduced without It's prior written consent. Touzet Studio shall be notified of any changes required by actual conditions as aforesaid prior to submission of any phase for construction. ©2009, TOUZET STUDIO. .................. ............................... OWNER NG HOLDINGS, LL( MECHANICAL / ELECTRICAL / PLUMBING/ FIRE PROTECTION ENGINEERS FRANYIE ENGINEERS, INC. ANTONIO FRANYIE PE #11640 VIVIANNA FRANYIE PE #49985 10610 NW 27th AVENUE MIAMI, FLORIDA 33172 305.592.1360 PROFESSIONAL LICENSE ................. ............................... ISSUE NO. DESCRIPTION ISSUE DATE PERMIT SET 11.04.09 .................. ............................... KEY PLAN PROJECT PROJECT NO.: 09 015 INTERIOR OFFICE REMODELING 7301 SW 57th COURT SPACE #525 SOUTH MIAMI, FLORIDA 33143 .................. ............................... DRAWING TITLE SCHEDULES & DETAILS SCALE DRAWING NO. AS NOTED MAN w Certificate of Authorization # 00002906 rc7 Street, 59 1360 Mia t L 33172 FAX: (305) 594-9279 ;, n en ineers.com WN ' DATE JOB NUMBER 09 -xxx Rry 4565 PONCE DE LEON SUITE 101 'CORAL GABJS FL 33146 TEL 305 7G9 2873 FAY 305 X89 2872 ARCHITECTURE LICENSE REGISTRATION NUMBERS CARLOS PRIO TOUZET FL AR0094099; JACQUELINE GONZALEZ FL AR0016319 .................. ............................... Drawings are subject to modification or change as required by actual measurements, standard Industry practices In light of existing structural and other conditions, applicable building codes, and the like. These plans are and shall remain the property of Touzet Studio and shall not be sold or reproduced without It's prior written consent. Touzet Studio shall be notified of any changes required by actual conditions as aforesaid prior to submission of any phase for construction. ©2009, TOUZET STUDIO. .................. ............................... OWNER NG HOLDINGS, LL( MECHANICAL / ELECTRICAL / PLUMBING/ FIRE PROTECTION ENGINEERS FRANYIE ENGINEERS, INC. ANTONIO FRANYIE PE #11640 VIVIANNA FRANYIE PE #49985 10610 NW 27th AVENUE MIAMI, FLORIDA 33172 305.592.1360 PROFESSIONAL LICENSE ................. ............................... ISSUE NO. DESCRIPTION ISSUE DATE PERMIT SET 11.04.09 .................. ............................... KEY PLAN PROJECT PROJECT NO.: 09 015 INTERIOR OFFICE REMODELING 7301 SW 57th COURT SPACE #525 SOUTH MIAMI, FLORIDA 33143 .................. ............................... DRAWING TITLE SCHEDULES & DETAILS SCALE DRAWING NO. AS NOTED MAN