09-1046-010PLUMBING NOTES 1.0 GENERAL 1.1 PROVIDE ( FURNISH AND INSTALL) ALL NECESSARY MATERIALS AND LABOR FOR A COMPLETELY OPERATIONAL PLUMBING SYSTEM AS SHOWN ON THE DRAWINGS AND HEREIN SPECIFIED. INSTALL IN ACCORDANCE WITH THE FLORIDA BUILDING CODE AND LOCAL ORDINANCES. 1.2 SCOPE OF WORK PROVIDE THE FOLLOWING COMPLETE SYSTEMS A. SANITARY COLLECTION. B. HOT AND COLD WATER SUPPLY. C. AIR CONDITIONING CONDENSATE. 1.3 PAY FOR ALL FEES, INSPECTIONS AND CONNECTION CHARGES REQUIRED, 1.4 VERIFY AT JOB SITE ALL SPACE CONDITIONS, DIMENSIONS WITH PIPE, FIXTURES, AND EQUIPMENT SIZES PRIOR TO FABRICATION OR INSTALLATION. COORDINATE REQUIREMENTS TO AVOID INTERFERENCE WITH OTHER TRADES. 1.5 SUBMIT SHOP DRAWINGS FOR ARCHITECT / ENGINEER APPROVAL BEFORE PROCEEDING WITH THE PURCHASE OR INSTALLATION OF EQUIPMENT AND MATERIALS. 1.6 GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE. 2.0 MATERIALS 2.1 PROVIDE SHUT —OFF VALVES FOR EACH FIXTURE AND WATER HAMMEL ARRESTOR WHERE SHOWN AND WHERE REQUIRED FOR PROPER PERFORMANCE OF THE SYSTEM. 2.2 PROVIDE DIELECTRIC FITTINGS TO CONNECT PIPING TO EQUIPMENT OF DISSIMILAR METALS. USE CLAMPS AND FASTENERS OF SIMILAR METALS OR ISOLATE THEM FROM PIPING AND SLABS TO PREVENT CORROSION. 2.3 PIPING 2.3.1 DOMESTIC HOT AND COLD WATER: COPPER TUBING TYPE "K" OR "L" WITH SOLDER JOINTS. WOG BRONZE VALVES 125 P.S.I. MIN. PROVIDE PRE — MOLDED FIBERGLASS INSULATION FOR HOT WATER LINES. 2.3.2 SANITARY WASTE, VENT, AND ROOF DRAINAGE CAST IRON PIPING NO —HUB 2.3.3 A/C CONDENSATE: ABOVE FLOOR: COPPER D.W.V. PIPE WITH ARMFLEX INSULATION. BELOW FLOOR: PVC SCHEDULE 40 AND FITTINGS. INSULATE ALL OVERHEAD HORIZONTAL RUNS WITH 1/2" ARMFLEX INSULATION. PLUMBING FIXTURE SCHEDULE SYMBOL FIXTURE TYPE SIZE C.W. H.W. DESCRIPTION KS KITCHEN SINK 2' 1/21 1/2, REF. REP. ICE MAKER - I/2 1 - a g M g N f�• ,-t Y 0 9 a N Ln Ln N W) N O 0 N 7 O n d FIF W I,EVEL BUILDING PLAN SCALE: 0 __- LIJ — — — — - I'. OFFICE ouITE 565 OFFICE SUITE 510 l i T I ±w -� �-„ •4111 � 1 I I � 't I k li r� offla WTE 560 4 � i I INSTAHOT E.W.H INSTANT -TEMP MDL: E-30,30100 WATTS, 208 -1 -60 1/21 1/20 n �I iz' I,z REMOVE EXIST. CAP EXIST. 3i4'C.W. SUPPLY AND CONNECT NEW Ii4' PIPE TO EXIST. COLD AND NOT WATER ISOMETRIC NTS �I <�� REMOVE EXIST. CAP —� AND CONNECT NEW 2' SAN VENT. TO EXIST. EXIST. 2-VENT. PIPE \-REMOVE EXIST. CAP AND CONNECT NEW 2" EXIST. 4'SAN. PIPE PIPE TO EXIST. SANITARY I OMETRIC NTS SAN. PIPE SLOPE 2' OR LESS 0 1/4' / FT 3' OR 5IcsGER * 1 /8' / FT i l -12 -09 PERMIT SET K1 #2 2009 4 - A^ I FO RANYIE PE 111640, �MECH 9965 ME U„ Certificate of Au 00002906 106110". °1� Street, Mia i L 33172 TEL: 591360 FAX: 305 594 -9279 W n en ineers.com DESIG1+i : F5 DATE JOB NUMBER 09 -XXX 4565 POM(F 01 LEON SUIT[ 201 CORAL GA3LES FL 33146 TEL 305 ?89 2E70 F4X 305 789 2872 ARCHITECTURE LICENSE REGISTRATION NUMBERS CARLOS PRIO TOUZET FL AR0094099; JACQUELINE GONZALEZ FL AR0016319 Drawings are subject to modification or change as required by actual measurements, standard industry practices in light of existing structural and other conditions, applicable building codes, and the like. These plans are and shall remain the property of Touzet Studio and shall not be sold or reproduced without It's prior written consent. Touzet Studio shall be notified of any changes required by actual conditions as aforesold prior to submission of any phase for construction. ©2009:TOUZEf STUDIO.. - OWNER NG HOLDINGS, LLC MECHANICAL 1 ELECTRICAL I PLUMBING/ FIRE PROTECTION ENGINEERS FRANYIE ENGINEERS, INC. ANTONIO FRANYIE PE #11640 VIVIANNA FRANYIE PE #49985 10610 NW 27th AVENUE MIAMI, FLORIDA 33172 305.592.1360 PROFESSIONAL LICENSE ............... ............................... ISSUE NO. DESCRIPTION ISSUE DATE PERMIT SET 11.04.09 i KEY PLAN ................ ............................... PROJECT PROJECT NO.: 09_015 INTERIOR OFFICE REMODELING 7301 SW 57th COURT SPACE #525 SOUTH MIAMI, FLORIDA 33143 DRAWING TITLE PLUMBING FLOOR PLAN WATER & SANITARY ISOMETRIC & NOTES SCALE ....' .................. DRAWING N0. ' ......... . 0 0 AS NOTED Pei O 1 a I