09-1046-004N.I.C. N.I.C. DEMOLITION - RCP SCALE:r = V -0" N.I.C. EXISTING WINDOW TO REMAIN AND BE PROTECTED DURING DEMOLITION AND CONSTRUCTION. �— DASHED LINES INDICATE EXISTING PARTITION WALL, DOORS & FRAMES TO BE REMOVED IN II �� THEIR ENTIRETY. u � 'I' III j IT -3° (VA.F. AGAINST PROPOSED PLANS) -- GC TO VERIFY EXISTING TENANT SEPARATION N.I.C. WALL IS 1 -HOUR FIRE -RATED PER CODE. ALL EXISTING OPENINGS, PENETRATIONS, ETC. TO BE FILLED WITH UL -RATED PUTTY CONFORMING TO 1 -HOUR RATING. EXISTING EGRESS STAIR (NOT IN SCOPE OF WORK) r EXISTING WINDOW TO REMAIN AND BE PROTECTED DURING DEMOLITION AND CONSTRUCTION. REMOVE EXISTING CARPET /PADDING FLOORING AND DISPOSE OEIN A RESPONSIBLE MANNER. PREPARE SUBFLOOR FOR NEW POLISHED CONCRETE FLOORING THROUGHOUT SPACE. ff\ — __—TI i' DI I II i II II � II II II II I Tj Li ------------------------ - - - - -- - - - - -- II II II I I DASHED LINES INDICATE EXISTING PARTITION WALL, I I DOORS & FRAMES TO BE REMOVED IN THEIR ENTIRETY. II II I I II II II II GC TO VERIFY EXISTING WALL I GC TO VERIFY EXISTING TENANT SEPARATION SEPARATION FROM EGRESS STAIR WALL IS 1 -HOUR FIRE -RATED PER CODE. ALL 2 -HOUR FIRE -RATED PER CODE. ALL EXISTING OPENINGS, PENETRATIONS, ETC. EXISTING OPENINGS, PENETRATIONS, ETC!, TO BE FILLED WITH UL -RATED PUTTY TO BE FILLED WITH UL -RATED PUTTY CONFORMING TO 1 -HOUR RATING. CONFORMING TO 2 -HOUR RATING. REMOVE EXISTING CARPET /PADDING FLOORING AND DISPOSE OF IN A RESPONSIBLE MANNER. PREPARE SUBFLOOR FOR NEW POLISHED CONCRETE FLOORING THROUGHOUT SPACE. _ GC TO VERIFY EXISTING SEPARATION WALL FROM PUBLIC ACCESS CORRIDOR IS 2 -HOUR FIRE- RATED (PLUSSPRINKLERS = 3 -HOUR RATING) PER CODE. ALL EXISTING OPENINGS, PENETRATIONS, ETC. TO BE FILLED WITH UL -RATED PUTTY CONFORMING TO 2 -HOUR RATING. FE DEMOLITION - FLOOR PLAN SCALE:" = V -0" EXISTING AHU CLOSET N.I.C. N.I.C. N.L(, 1 tra �e ��..1 -� n — RCP LEGEND OETR � FIRE SPRINKLER - EXISTING TO REMAIN �R FIRE SPRINKLER - RELOCATE PER NEW FIRE SAFETY PLANS ❑ FIRE STROBE - RELOCATE PER NEW FIRE SAFETY PLANS F_q EMERGENCY LIGHTING - RELOCATE PER NEW FIRE SAFETY PLANS DEMOLITION/CONSTRUCTION LEGEND EXISTING WALL TO REMAIN EXISTING WALL TO BE DEMOLISHED EXISTING DOOR TO REMAIN w EXISTING DOOR TO BE DEMOLISHED �I all GENERAL NOTES 1. ALL DIMENSIONS ARE TO BE FIELD VERIFIED, ANY DISCREPANCIES ARE TO BE DIRECTED IN WRITING TO THE ARCHITECT PRIOR TO COMPLETION OF THE WORK. o°�����yy°p�;ggr �' 1' YpalA MIAMI i. U I ri..- U'W .3. F) Y. -Pis °iT?LJ( s uFta' i ; 'Aejlc) APPRWED 5f: LtJ9 DEMOLITION GENERAL NOTES 1. EXISTING STRUCTURE TO REMAIN IN ITS ENTIRETY, UNLESS OTHERWISE NOTED. 2. ALL EXISTING FINISH SURFACES TO BE REMOVED AND RECYCLED WHEREVER POSSIBLE. STRUCTURE BELOW EXISTING FINISHES TO BE CLEANED, LEVELED AND /OR OTHERWISE PREPARED FOR NEW PROPOSED FINISHES IN ACCORDANCE WITH DRAWINGS. 3. ALL EXISTING OPENINGS AND STRUCTURAL ITEMS TO BE VERIFIED IN FIELD, 4. CONTRACTOR SHALL CHECK & VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO PROCEEDING WITH THE WORK. 5. ARCHITECT IS TO BE NOTIFIED IN WRITING OF ANY DISCREPANCIES IN PLAN, PRIOR TO WORK PROCEEDING. 6. FLOORING AND WALLS SHOULD BE LEVEL AND PLUMB WITHIN ACCEPTABLE CONSTRUCTION TOLERANCES TO RECEIVE NEW FINISHES. 7. CONTRACTOR SHALL REMOVE ALL CONSTRUCTION DEBRIS FROM THE SITE AND DISPOSE OF SAID IN A LAWFUL MANNER, 8. CONTRACTOR, SOLELY, SHALL BE RESPONSIBLE FOR ADEQUATE BRACING AND SHORING OF ALL EXISTING AND NEW STRUCTURAL AND NON - STRUCTURAL ITEMS DURING DEMOLITION AND CONSTRUCTION AND PROVIDE SIGNED AND SEALED CALCULATIONS AS REQUIRED. 9. FIELD VERIFY HIDDEN OR UNFORESEEN EXISTENCE OF EMBEDDED STRUCTURAL ELEMENTS. 10. ( ONTRACTOR TO REMOVE /RELOCATE ALL EXISTING PLUMBING, ELECTRICAL, MECHANICAL, AS REQUIRED. 11. THE EXTENT OF DEMOLITION PLAN MAY NOT ENCOMPASS THE ENTIRE DEMOLITION NECESSARY TO ACCOMPLISH THE ENTIRE WORK. CONTRACTOR IS RESPONSIBLE FOR SCOPE OF WORK INCLUDING DEMOLITION IN ORDER TO ACCOMPLISH THE ENTIRE WORK. 12. EXISTING ITEMS SHOWN WITH A DASHED LINE ON DEMOLITION PLAN ARE TO BE REMOVED. AREA TO BE CLEANED, LEVELED, AND PREPARED AS REQUIRED FOR NEW FINISHES AND FIXTURES: 13. GC TO COORDINATE WITH PROPERTY MANAGER WITH REGARD TO CONSTRUCTION PROCEDURES INCLUDING, BUT NOT LIMITED TO:DEMOLITION, TRASH REMOVAL, PARKING PROCEDURE, SCHEDULING, ETC. 14. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING TREES, UTILITIES, WALKS, AND ALL ADJACENT STRUCTURES DURING DEMOLITION AND CONSTRUCTION AND REPLACE, REPAIR ALL SURFACES (INTERIOR AND /OR EXTERIOR) OR ANY OTHER AFFECTED AREAS AS MAY BE REQUIRED. 15. GC TO VERIFY ALL DEMOLITION ITEMS IN FIELD AND COORDINATE WITH OWNER PRIOR TO DEMOLITION OF ANY ITEMS IN DISPUTE. 16. DEMOLITION SCOPE OF WORK INCLUDES, BUT IS NOT NECESSARILY LIMITED 10, THE FOLLOWING: REMOVE ALL EXISTING FLOOR FINISHES DOWN TO THE STRUCTURE PREPARE EXISTING FLOOR FOR NEW FINISHES - REMOVE EXISTING WALLS AS INDICATED ON THE PLANS. EXISTING WALLS TO REMAIN ARE TO BE PROTECTED DURING DEMOLITION & CONSTRUCTION & PREPARED FOR NEW WALL FINISHES a aaaoa --- - ha a a e - eY 4565 PONCE DE LEON SUITE 201 CORAL GABLES FL 33146 TEL 305 789 2870 FAX 305 789 2872 ARCHITECTURE LICENSE REGISTRATION NUMBERS CARLOS PRIO TOUZET FL AR0094099; JACQUELINE GONZALEZ FL AR0016319 Drawings are subject to modification or change as required by actual measurements, standard industry practices in light of existing structural and other conditions, applicable building codes, and the like. These plans are and shall remain the property of Touzet Studio and shall not be sold or reproduced without it's prior written consent. Touzet Studio shall be notified of any changes required by actual conditions as • aforesaid• prior to submission of any phase for construction. © 2009, TOUZET STUDIO. OWNER NG HOLDINGS, LL( MECHANICAL / ELECTRICAL / PLUMBING/ FIRE PROTECTION ENGINEERS FRANYIE ENGINEERS, INC. ANTONIO FRANYIE PE #11640 VIVIANNA FRANYIE PE #49985 10610 NW 271h AVENUE MIAMI, FLORIDA 33172 305.592.1360 .......................... PERMIT SET 11.12.09 KEY PLAN PROJECT PROJECT NO.: 09_015 INTERIOR OFFICE REMODELING 7301 SW 57th COURT SUITE #525 SOUTH MIAMI, FLORIDA 33143 DRAWING TITLE DEMOLITION FLOOR PLAN, RCP AND NOTES I SCALE .......... . ........... DRAWING N0.............. . AS SHOWN D • 1 AS NOTED PROFESSIONAL LICENSE w� r ) 9 i ISSUE NO. DESCRIPTION ISSUE DATE PERMIT SET 11.12.09 KEY PLAN PROJECT PROJECT NO.: 09_015 INTERIOR OFFICE REMODELING 7301 SW 57th COURT SUITE #525 SOUTH MIAMI, FLORIDA 33143 DRAWING TITLE DEMOLITION FLOOR PLAN, RCP AND NOTES I SCALE .......... . ........... DRAWING N0.............. . AS SHOWN D • 1 AS NOTED