09-1041-001
°off, STROBE OUTPUT LOAD TABLE HORNUSTR 750 ire HORNISTR 110CD ma STR 750 ma STR 1100 ma TOTAL Length Wire Size Vdr Last Device out Circuit O Sub -Tot CITY Sub-Tot CITY Sub -Tot CITY Sub -Tar m4 feet AWG v von STR CIRC #1 1ST LEVEL 161 x 0 0 203 x 1 203 152 x' 1 152 219 x 5 1095 1450 300 14 2262 21738 STIR CIRC #2 1ST LEVEL 161 x 0 0 203 x 0 0 152 x' 1 152 219 x 3 657 809 300 14 1262 2273796 STR CIRC #2A 1ST LEVEL 161 x 0 0 203 x 7 1421 152 x1 0 0 219 x 0 0 1421 3DO _ _ 14 22168 21 79324 STR CIRC #3 2ND LEVEL 161 x 0 0 203 x 0 0 152 x1 2 304 219 x 7 1533 1837 300 14 28657 21 13428 STR CIRC #4 2ND LEVEL 161 x 0 0 203 x 0 0 152 x' 0 0 219 x 5 1095 1095 300 14 17082 222919 STR CIRC #5 2ND LEVEL 161 x 0 0 203 x 0 0 152 x'. 0 0 219 x 5 1095 1095 300 14 17082 222918 STR CIRC #6 3TH LEVEL 161 x 0 0 203 x 0 0 152 x 2 304 219 x 7 1533 1837 300 14 28657 21 13428 STR CIRC IF 3THLEVEL 161 x 0 0 203 x 0 0 152 x 0 0 219 x 5 1095 1095 300 14 17082 222918 STR CIRC #8 3TH LEVEL 161 x 0 0 203 x 0 0 152 x 1 0 0 219 x 5 1095 1095 300 14 1 7062 222918 STR CIRC #9 4TH LEVEL 161 x 0 0 203 x 0 0 152 x'1 0 0 219 x 8 1752 1752 1 300 14 27331 21 266W STR CIRC #10 4TH LEVEL 161 x 5 805 203 x 0 0 152 x'. 5 760 219 x 0 0 1565 300 14 24414 215586 STR CIRC #104 4TH LEVEL 161 x 0 0 203 x 10 2030 152 x' 0 0 219 x 0 0 2030 ! 300 14 31668 208332 STR CIRC #11 5TH LEVEL 161 x 4 644 203 x 0 0 152 x' 7 1064 219 x 0 0 1708 300 14 26645 2133552 STR CIRC #11A 5TH LEVEL 161 x 0 0 203 x 9 1827 152 x' 2 304 219 x 0 0 2131 300 14 33244 2067564 STR CIRC #118 STHLEVEL 161 x 2 322 203 x 6 1218 152 .1-3 456 219 x 0 0 1996 300 14 31138 2088624 STR. CIRC.fl11C 5TH LEVEL) 281 r 1 281 337 z 0 0 255 x S 1275 311 x 0 0 1556 300 14 2.4274 17.97264 STR CIRC EST2 Cabinet Battery Calculation (EXISTING) II CCD BATTERY CALCULATIONS BPS -10 # Description lQuantity 110CD I ITEM Standby (ma) Alarm (ma) Total Alarm(ma) STANDBY ALARM ACTIVATED BOTH HORN (mA) CITY x 0 I Sub-Tot 0 TOTAL (mA) 360 Length (feet) 500 CURRENT CURRENT 2 -MCM Main Controller /LCD CURRENT 1 x 150 150 275 275 SUB -TOTAL Front Panel LED Modules SUB -TOTAL 1 x 5 5 16 16 AMPS DL2 Module AMPS 1 x 10 10 20 20 0 2 -LSRA 2 295 0 x 80 0 80 0 0 Siga Smoke Detectors 2 248 26 x 0 000045 000117 0000045 0.00117 0 Siga Single Stage Pull Stations 0 674 14 x 0.00025 00035 0.0004 0.0056 007 Siga -CT1 0 105 6 x 0.00025 00015 0.0004 00024 F -2 Siga -CC1 SD -3 S6-4 SD -5 SD -6 HD -1 7 x 0.00023 0.00161 0.0001 00007 0 07 Siga-CR 5.322 17 x 0.0001 00017 0.0001 0.0017 W Siga -WTM F -2 5 x 0.00025 0.00125 000025 0.00125 � Siga-RM1 0 O x 0.0002 00002 000025 0 �aaaW Heat Detector -1 2 x 0000045 0.00009 0.000045 0.00009 V i STANDBY 60 TOTAL (A) 165.01 TOTAL(B) 311.01 0 083 IHOURS Battery Calculation i1 LA 0 r In to N 00 EN .� 4-J 00 LJi 00 O Vi to tJ1 CJ QJ v M Cfi C) F- LL. O "L REQUIRED TOTAL SYSTEM REQ STANDBY REQUIRED TOTAL SYSTEM REQUIRED ALARM W Superusory Hours (C) 60 STANDBY CURRENT Battery Capacity (A. H) = 11 2[(AxC) +(0 0167xBxD)I /1000 ALARM CIRCUIT Alarm Minutes (D) 5 Battery Capacity (A.H) = 19926630778 IBatt.Capacity1OA1H AMP -HOURS HOURS AMPS AMP -HOURS 60 007 42 0 083333333 5 322 0.4435 REQ STANDBY REQUIRED ALARM TOTAL REQ OPTIONAL REQ BATTERY CAPACITY CAPACITY CAPACITY FACTOR OF CAPACITY AMP -HOURS AMP -HOURS AMP -HOURS SAFETY AMP -HOURS 42 04435 46435 1 2 5 5722 7.0 A/H Su Iled #1 161 x 0 0 203 x 0 0 152 x' 0 0 219 x 2 438 438 ' 300 14 06833 2331672 °off, STROBE OUTPUT LOAD TABLE HORNUSTR 750 ire HORNISTR 110CD ma STR 750 ma STR 1100 ma TOTAL Length Wire Size Vdr Last Device out Circuit O Sub -Tot CITY Sub-Tot CITY Sub -Tot CITY Sub -Tar m4 feet AWG v von STR CIRC #1 1ST LEVEL 161 x 0 0 203 x 1 203 152 x' 1 152 219 x 5 1095 1450 300 14 2262 21738 STIR CIRC #2 1ST LEVEL 161 x 0 0 203 x 0 0 152 x' 1 152 219 x 3 657 809 300 14 1262 2273796 STR CIRC #2A 1ST LEVEL 161 x 0 0 203 x 7 1421 152 x1 0 0 219 x 0 0 1421 3DO _ _ 14 22168 21 79324 STR CIRC #3 2ND LEVEL 161 x 0 0 203 x 0 0 152 x1 2 304 219 x 7 1533 1837 300 14 28657 21 13428 STR CIRC #4 2ND LEVEL 161 x 0 0 203 x 0 0 152 x' 0 0 219 x 5 1095 1095 300 14 17082 222919 STR CIRC #5 2ND LEVEL 161 x 0 0 203 x 0 0 152 x'. 0 0 219 x 5 1095 1095 300 14 17082 222918 STR CIRC #6 3TH LEVEL 161 x 0 0 203 x 0 0 152 x 2 304 219 x 7 1533 1837 300 14 28657 21 13428 STR CIRC IF 3THLEVEL 161 x 0 0 203 x 0 0 152 x 0 0 219 x 5 1095 1095 300 14 17082 222918 STR CIRC #8 3TH LEVEL 161 x 0 0 203 x 0 0 152 x 1 0 0 219 x 5 1095 1095 300 14 1 7062 222918 STR CIRC #9 4TH LEVEL 161 x 0 0 203 x 0 0 152 x'1 0 0 219 x 8 1752 1752 1 300 14 27331 21 266W STR CIRC #10 4TH LEVEL 161 x 5 805 203 x 0 0 152 x'. 5 760 219 x 0 0 1565 300 14 24414 215586 STR CIRC #104 4TH LEVEL 161 x 0 0 203 x 10 2030 152 x' 0 0 219 x 0 0 2030 ! 300 14 31668 208332 STR CIRC #11 5TH LEVEL 161 x 4 644 203 x 0 0 152 x' 7 1064 219 x 0 0 1708 300 14 26645 2133552 STR CIRC #11A 5TH LEVEL 161 x 0 0 203 x 9 1827 152 x' 2 304 219 x 0 0 2131 300 14 33244 2067564 STR CIRC #118 STHLEVEL 161 x 2 322 203 x 6 1218 152 .1-3 456 219 x 0 0 1996 300 14 31138 2088624 STR. CIRC.fl11C 5TH LEVEL) 281 r 1 281 337 z 0 0 255 x S 1275 311 x 0 0 1556 300 14 2.4274 17.97264 STR CIRC EST2 Cabinet Battery Calculation (EXISTING) II CCD BATTERY CALCULATIONS BPS -10 # Description lQuantity 110CD I ITEM Standby (ma) Alarm (ma) Total Alarm(ma) STANDBY ALARM ACTIVATED BOTH HORN (mA) CITY x 0 I Sub-Tot 0 TOTAL (mA) 360 Length (feet) 500 CURRENT CURRENT 2 -MCM Main Controller /LCD CURRENT 1 x 150 150 275 275 SUB -TOTAL Front Panel LED Modules SUB -TOTAL 1 x 5 5 16 16 AMPS DL2 Module AMPS 1 x 10 10 20 20 0 2 -LSRA 2 295 0 x 80 0 80 0 0 Siga Smoke Detectors 2 248 26 x 0 000045 000117 0000045 0.00117 0 Siga Single Stage Pull Stations 0 674 14 x 0.00025 00035 0.0004 0.0056 007 Siga -CT1 0 105 6 x 0.00025 00015 0.0004 00024 F -2 Siga -CC1 SD -3 S6-4 SD -5 SD -6 HD -1 7 x 0.00023 0.00161 0.0001 00007 0 07 Siga-CR 5.322 17 x 0.0001 00017 0.0001 0.0017 W Siga -WTM F -2 5 x 0.00025 0.00125 000025 0.00125 � Siga-RM1 0 O x 0.0002 00002 000025 0 �aaaW Heat Detector -1 2 x 0000045 0.00009 0.000045 0.00009 V i STANDBY 60 TOTAL (A) 165.01 TOTAL(B) 311.01 0 083 IHOURS Battery Calculation i1 LA 0 r In to N 00 EN .� 4-J 00 LJi 00 O Vi to tJ1 CJ QJ v M Cfi C) F- LL. O "L REQUIRED TOTAL SYSTEM REQ STANDBY REQUIRED TOTAL SYSTEM REQUIRED ALARM W Superusory Hours (C) 60 STANDBY CURRENT Battery Capacity (A. H) = 11 2[(AxC) +(0 0167xBxD)I /1000 ALARM CIRCUIT Alarm Minutes (D) 5 Battery Capacity (A.H) = 19926630778 IBatt.Capacity1OA1H PERMIT AREA ONLY (EXISTING) PANEL "4HF', DEDICATE BREAKER #13 20A.1P.12OV r I2- X12'X6� mm ®uu � nnn ®uu � IIBIIIPI 0 1611 SAB,IA I IelPn ul I 4S,IB,IA LOCATED 6,_E� I I I I 1f12THHN GREEN i1#12THHN GREEN L ___J r'C IA--- 12'X12'X61 LOCATED AT ELECT, M. uunuunnl PANEL -4HF-, DEDICATE © • BREAKE R #5 20A 1P.120V BPS #4 IIIIIIIIIIIIIII S,1B,2A 1 #1ZTHHN GREEN 1'C ALL 3/4" CONDUIT UNLESS OTHERWISE NOTICED 00 II CCD BATTERY CALCULATIONS BPS -10 # 5 EXISTING 11XD 110CD RECALL ITEM DESCRIPTION QTY STANDBY STANDBY ALARM ACTIVATED BOTH HORN (mA) CITY x 0 I Sub-Tot 0 TOTAL (mA) 360 Length (feet) 500 CURRENT CURRENT CURRENT CURRENT CURRENTS x 11 440 20 PER UNIT SUB -TOTAL PER UNIT SUB -TOTAL TOTAL 14 1 144 22 856 HORN CIRC #3(3RD LEVEL) AMPS AMPS AMPS AMPS 20 x 1 STROBE 75CD 9 0 0 0 255 2 295 2.295 40 2 HORWSTROBE 75CD 8 0 0 0 281 2 248 2.248 500 3 HORN/STROBE 11OCD 2 0 0 0 337 0 674 0 674 20 4 BPS10 1 007 007 0 105 0 105 0 175 F SD SD 5p SD E D E E E -1 F -2 SD -1 SD -2 SD -3 S6-4 SD -5 SD -6 HD -1 0 EOL ST#s (1.31A) AC AC TOTAL 1' WP WP 0 07 I L- _ _ _ _ _ _ _ _ _ _ J 5.322 EOL HORN#2 (0.440A) RF F 0 U) Li W -1 F -2 1' HD -1 WP WT -2 W � 0 0 F F [ to REQUIRED OPERATING TIME OF SECONDARY POWER SOURCE FROM NFPA 72 �aaaW -1 F -2 F HD -1 V i STANDBY 60 HOURS ALARM 5 MINUTES X 1/ 60 0 083 IHOURS CO Ln ^ In i1 LA 0 r In to N 00 EN .� 4-J 00 LJi 00 O Vi to tJ1 CJ QJ v M Cfi C) F- LL. O "L REQUIRED TOTAL SYSTEM REQ STANDBY REQUIRED TOTAL SYSTEM REQUIRED ALARM W E. BORJA STANDBY TIME STANDBY CURRENT CAPACITY ALARM TIME ALARM CIRCUIT CAPACITY SHEET: FA_j OF � j HOURS AMPS AMP -HOURS HOURS AMPS AMP -HOURS 60 007 42 0 083333333 5 322 0.4435 REQ STANDBY REQUIRED ALARM TOTAL REQ OPTIONAL REQ BATTERY CAPACITY CAPACITY CAPACITY FACTOR OF CAPACITY AMP -HOURS AMP -HOURS AMP -HOURS SAFETY AMP -HOURS 42 04435 46435 1 2 5 5722 7.0 A/H Su Iled 00 HARDWIRE RELAY T❑:UPERVISE 1 1LQCD 1 tQCD EOL ST#12 (0.438A) POWER FOR SHUNT TRI OPERATION RELAY TO BE ACTIVATED BY HEAT DETECTOR AT EOL HORN15 (0.08A) ELEV. SHAFT & MACH, RM. CR -4 1 HD -1 II CCD HORN OUTPUT LOAD TABLE 11XD 110CD RECALL RECALL HAT SHUNT TRIP SUPERVISION r---------------------- - ---� P Output arcult HORN CIRC #1(1STLEVEL) HORN (mA) 40 x QTY 9 Sub-Tot 360 MINI 20 HORN (mA) CITY x 0 I Sub-Tot 0 TOTAL (mA) 360 Length (feet) 500 Wire Size AWG 14 Vdrop V 0936 Last Device Voltage(V) 23064 HORN CIRC #2(2ND LEVEL) 40 x 11 440 20 x 0 0 440 500 14 1 144 22 856 HORN CIRC #3(3RD LEVEL) 40 x 11 440 20 x 0 0 440 500 14 1 144 22 856 HORN CIRC 94(4TH LEVEL) 40 x 5 200 20 x 0 0 200 500 14 052 2348 HORN CIRC #5(ROOF) 40 x 2 80 20 x 0 0 1 80 1 500 14 0208 23 792 HARDWIRE RELAY T❑:UPERVISE 1 1LQCD 1 tQCD EOL ST#12 (0.438A) POWER FOR SHUNT TRI OPERATION RELAY TO BE ACTIVATED BY HEAT DETECTOR AT EOL HORN15 (0.08A) ELEV. SHAFT & MACH, RM. CR -4 1 HD -1 WIRE LEGEND: A = 2 #18 FPL (DATA)(UNSHIELDED)(BLUE) B = 2 #14 FPL (HORN)(UNSHIELDED)(RED) S = 2 #14 FPL (STROBE)(UNSHIELDED)(RED) P = 2 #16 FPL (POWER)(UNSHIELDED)(RED) ALL CONDUITS 3/4" EMT MINIMUM.40% FILLED MAX. FOR RISER AND WHERE REQUIRED. ROOF PERMIT AREA ONLY NAC #1:EOL ST #1 EOeL ST 1 #11A INAC #2:EOL ST #12 I EOL ST #11B INAC #3:EOL HORN #51 INAC #4:EOL ST #11C I--- - - - - -- 110CD II CCD PRIM. ALT. FIRE CT -1'�' MODULE TO INDICATE 11XD 110CD RECALL RECALL HAT SHUNT TRIP SUPERVISION r---------------------- - ---� P P P P t11(EOL STf 6 (2.OA) NSCD 75T NsTcD oL ST#11C (55A) j?ERMIT T E IIIIIIIIIIIIIII IIIIIIIIIIIIIII IIIIIIIIIIIIIII 201 202 203 PrEOLSTf91.75A) S6 -1 AREA ONLY S11C -1 S11C -2 S11C- 2AQS11C -3 S11C -340. 5110 -4 S9-5 _ _ _ _ _ S97 S9-8 S9-8 EOLHORK (0.2A) ,41B 7D 7500 75CD 75CD 75CD 75CD, 7CD 75CD n EOL ST#11 (1.7A) �7D STROBE (11 OCD)(WEATHERPROOF) CS405-8A-TW/LKW- 1 /449 T 110CD S11 -1 S11 -2 S11 -3 S11-4 S11 -5 S11 -4A S11 -5A S11 -6 S' -7 S1 -8 S11 -9 7 11 11D 11Q�D 11 7:D iCD 75CD 11 11 7D 7 Fl EOL ST#11 B (2.03A) 7�D 75 7 EOL ST#10 (1.56A) 5CD 'T EOL ST #9 r}G1 T S7 -4 sim -1 S11A -2 S11A -3 S11A -4 S11A -5 S11A -6 S11A -7 S11A -8 SA -9 SIR -10 S11A -11 T 11 11D IIn 11D 110CD 11 11 7ig1 TO 11 D 510-3 510-4 S1D-5 S10-4A -r EOL ST #11A (2.16A) s11B -1 S11B -2 S118 -3 S11B -4 S11B -5 S116 -6 S116 -7 S11B -8 s9-9 S6 -10 SIIB -11 PERMIT AREA ONLY 11000 110CD 11DCD r------ - - - --1 E CT -1 WT-1 DD -1 DD -2 CR -1 CR -2 SD $D D F F SD SD 5p SD E D E E E -1 F -2 SD -1 SD -2 SD -3 S6-4 SD -5 SD -6 HD -1 I I EOL ST#s (1.31A) AC AC S5 -1 1' WP WP WT -2 I L- _ _ _ _ _ _ _ _ _ _ J WIRE LEGEND: A = 2 #18 FPL (DATA)(UNSHIELDED)(BLUE) B = 2 #14 FPL (HORN)(UNSHIELDED)(RED) S = 2 #14 FPL (STROBE)(UNSHIELDED)(RED) P = 2 #16 FPL (POWER)(UNSHIELDED)(RED) ALL CONDUITS 3/4" EMT MINIMUM.40% FILLED MAX. FOR RISER AND WHERE REQUIRED. ROOF PERMIT AREA ONLY NAC #1:EOL ST #1 EOeL ST 1 #11A INAC #2:EOL ST #12 I EOL ST #11B INAC #3:EOL HORN #51 INAC #4:EOL ST #11C I--- - - - - -- 110CD II CCD 11XDP 11 DP 11XD 110CD 11Q�D 110CD P P P P P t11(EOL STf 6 (2.OA) T Y4Y T T IIIIIIIIIIIIIII IIIIIIIIIIIIIII IIIIIIIIIIIIIII 201 202 203 PrEOLSTf91.75A) S6 -1 S6 -2 S9 -1 S9 -2 S9 -3 -3Y S99 S9-5 S9-6 S9�6NP S97 S9-8 S9-8 EOLHORK (0.2A) ,41B Box S3 -6 S3 -7 S3 -8 9 JUNCTION 110CD STROBE (11 OCD)(WEATHERPROOF) CS405-8A-TW/LKW- 1 /449 IS 110CD 110CD 1 D BPS#4 7 7 7 75CD 75CD 75CD 75CD 75CD 7�D 75 7 EOL ST#10 (1.56A) 5CD 'T EOL ST #9 S7 -2 S7 -3 S7 -4 T T T T T 110CD EOL ST #10 S10 -1 SID-2 510-3 510-4 S1D-5 S10-4A S1D-5A S10-6 S9-7 )-8 510-9 510-10 EOL ST# 1 OA 110CD 110CD 110CD 11000 110CD 11DCD itOCD 110CD 110 OCD 1A WEOL ST#1OA (2.OA) EOL HORN #4 S10A -1 S10A-2 S10A -3 S10A -4 S10A -5 S1W -6 S1OA -7 S10A-8 STYE -9 )A -10 _ WT -A SD-4 is 110CD 75CD 110CD 110CD 110�CD 110CD 1 CD 110CD 110CD :D 12'X121X6� P 1 UCD 110CD 110CD 7 P P P P P t11(EOL STf 6 (2.OA) T T T T IIIIIIIIIIIIIII IIIIIIIIIIIIIII IIIIIIIIIIIIIII 201 202 203 T S6 -1 S6 -2 S6 -3 S6 -4 T S6 -5 S6 -6 S6 -7 S6 -8 -9 JUNCTION S3 -1 S3 -2 S3 -3 S3 -4 ,41B Box S3 -6 S3 -7 S3 -8 9 JUNCTION 110CD STROBE (11 OCD)(WEATHERPROOF) CS405-8A-TW/LKW- 1 /449 IS 110CD 110CD 1 D 1 P 1 CP 1 P 110CD S2 -1 S2 -S2 -2 - S2 -4 T EOL ST17 (1.53A) S4 -1 S7 -6 S7 -2 S7 -3 S7 -4 S -5 S7 -7 1 CD 110CD 11OCD 11OCD 110CD B 1 1 CD 110CD 1 CD 1 CD 1 CD 1 CD 54 -6 S4 -2 S4 -3 P P P S2A -5 T 110CD 1 CD EOL ST /8 (1.31A) S8 -1 S8 -6 S8 -2 S8 -3 S8 -4 S8 -5 EOL HORN#3 (0.440A) 1A,3S,IB I �S5-4 �1C EOL ST#s (1.31A) F D S5 -1 1' WP WP WT -2 F -2 F -3 EOL HORN#2 (0.440A) RF F 0 U) Li W -1 F -2 1' HD -1 WP WT -2 12'X12'X61 IS,1 110CD 75CD 110CD 110CD 110CD 110CD 1 UCD 110CD 110CD 7 12'X12'X6`� P P BPS #2 P P DUCT DETECTOR P P EOL ST#3 (2.OA) IIIIIIIIIIIIIII IIIIIIIIIIIIIII IIIIIIIIIIIIIII 201 202 203 EST -2 0 T T T S1 -5 T T T REMOTE STATION S3 -1 S3 -2 S3 -3 S3 -4 S3 -10 S3 -5 S3 -6 S3 -7 S3 -8 9 JUNCTION 110CD STROBE (11 OCD)(WEATHERPROOF) CS405-8A-TW/LKW- 1 /449 80" AFF TO BOTTOM t WIR ID 757- 8A- TW /757A -WBW B EOL 1A BOX S2 -1 S2 -S2 -2 - S2 -4 SIGA -270 48" AFF TO CENTER 1 110CD 110CD 1 CD 1 CP 1 P 1 CD 110CD 11OCD 11OCD 110CD 110CD 110CD Etivl ELEVATOR WARNING LIGHT EOL ST#4 (1.53A) 72" AFF TO CENTER S4 -1 54 -6 S4 -2 S4 -3 S4 -4 S -5 S4 -7 S2A -5 1S 1 CD 110CD 1 CD ® SIGNAL MODULE WP WP DD -1 DD -21 T SD �1C �S5-4 �1C EOL ST#s (1.31A) F D S5 -1 S5 -6 S5 -2 F -1 F -2 F -3 EOL HORN#2 (0.440A) IA,6S,2B I 0 U) Li W W 1' WP WP WT -2 W � 0 0 F F [ to CD \ �aaaW -1 F -2 F HD -1 12'X12'X61 ls,l 1 LQCD 111111111111111 1 UCD 111111111111111 75CD IIIIIIIIIIIIIII 110CD EOL ST#1 (1.4A) .................. WP BPS #1 P BPS #2 WP BPS #3 DUCT DETECTOR FACP IIIIIIIIIIIIIII IIIIIIIIIIIIIII IIIIIIIIIIIIIII 201 202 203 EST -2 0 - - S1 -3 1 #12THHN GREEN S1 -5 2 PHONE LINES FOR S1 -7 REMOTE STATION 200 NOTIFICATION - 110C D 1#12THHN GREEN ls,l 1 LQCD 1 JQCD 1 UCD 1tQCD 75CD 1 CD 110CD EOL ST#1 (1.4A) WP WP P P T WP 11- Do-- DUCT DETECTOR SIGA -PS / SIGA -DH SIGA -SB SIGA -LED 6261006 "' S1 -1 S1 -8 S1 -3 S1 -4 S1 -5 S1 -6 S1 -7 80" AFF TO BOTTOM 1 75CD I 110CD 110C 110C D 110CD 110CD 757 -8A -T 110CD STROBE (11 OCD)(WEATHERPROOF) CS405-8A-TW/LKW- 1 /449 80" AFF TO BOTTOM t WIR ID 757- 8A- TW /757A -WBW B EOL 1A WP S2 -1 S2 -S2 -2 - S2 -4 SIGA -270 48" AFF TO CENTER ® .75CD OL #1 (0036 SIZE AS NEEDED ® 1 110CD 110CD 11OCD 11OCD 110CD 110CD 110CD Etivl ELEVATOR WARNING LIGHT EL -1 72" AFF TO CENTER ® © WATERFLOW/TAMPER MODULE TAMPER SWITCH EOL ST#2A (1.42 S2A -1 S2A -2 S2A -3 S2A -4 S2A -5 S2A -6 S2A -7 1 E ® SIGNAL MODULE WP WP DD -1 DD -21 SD SD F F F F F D D SD -1 SD -2 F -1 F -2 F -3 F -4 F -5 Z CD 5TH FLOOR 4TH FLOOR PARKING 3TH FLOOR PARKING EWL 101 2ND FLOOR PARKING DD -7 DD -8 DD -9 DD -10 A,1P Lo R R -2 CR CR -4 CR -5 CR -6 CR -7 CR -8 I CR -10 CT -1 CT -2 WT -1 CT -3 CT -4 AC -6 AC -5 AC -4 AC -3 AC -2 AC -1 AC -10 AC -9 / AC -7 TO FACP EWL BACK FLOW 100 PANEL "4Hr. DEDICAIT MAIN RISER PREVENTER BREAKER 20A.1P.120V VALVE CR -11 CKT -4 (FACP.BPS /1,2.3) 1ST FLOOR PARKING EXISTING RE ALARM RISER: N.T.S System No. C -AJ -1149 F Rating - 2 Hr T Rating - 0 Hr L Rating At Ambient - Less Than 1 CFM/sq ft L Rating At 400 F - 4 CFM /sq ft A 2 0 4 4 i� A 3 1 SECTION A -A 1. Floor or Wall Asmmby - Wn 4-1/2 iR thick reinforced i¢drei t or nand -150 ( 100 -150 pd) concrete. Mal may abo be cwabw ed of any UL Classified Concrete Blocks '. Max darn of opsnig is 12 h See Concrete Blacks (Wo category In the rre Resistance Mwtay for mmes of nxrnlachsers. 2 Rmgh Penetrants - One reEdie pipe, cmdLft or tubig to be Mailed within the fresfnp system. Pipe, conduit or bbog to be rigidy supported on bath sides of floor or wall assembly. The oenular space aldl be 0 Ea (point contact) to mac 1 -1/4 in. The falkrwirg Lypse and sim of nstafia pipes, cordults or tubig mq be used: A Steel P'pe - Nom 10 k dam (err smaller) Sd ed4e 10 (or heavier) $test pipe. B. Conduit - Nom 4 in dam (o smaller) shed ebcbicd meiotic tAig or steal conduit C. Capper Tubirg - Nam 4 R dam (or scaler) Type L (or heavier) copper hii*4 D. plpCopper pipe - Nom 4 iii dam (or emaler) RM*r (or heavier) copper 3. Pocking Material - M'n 3 in. Nc nm of mn 4 pd n"d wool bad irmdatim for nom 4 in. don (and rider) ppes, corndulls or Ubp and a min 4 kL thidasse of min 4 pd mrsrd wool butt kw*bw for pipe peeler then ram 4 inn dam, frmly pocked into ope ling as a pemnasrrt form. Pod&q material to be receaad from bop surface of floor or from both srfotes of wall as regkired to accommodate the rogk W th ch" Of fill material 4. nil. Void or Cavity Matedar - Sealant - Min 1/2 h thktosss of h7 material applied waft the omalus, Ouch wlib the top sLdwe of floor or both surfaces of wall At the point of cu. koafan between pipe and =cute, a min 1/2 in. can bead of fill material stern be applied at IN /pqe kW000 on the top 20ace of floor and on bath surfaces of wall. HIL11 CONS1i XWN MICALS. Blv OF NIL11 INC - CP601S. 016M or FS -flirt Sedmt (Ibtc LL RaUrxp op* a when FS-W Sealant is used). UL m ] � -P Fl Ia RESP S1SiFY5 Cr O U E - J SEQUENCE OF OPERATION 1. SEQUENCE OF OPERATION SHALL AS FOLLOWS: A. OPERATION OF TAMPER, SWITCH - SUPERVISORY INDICATION. C. OPERATION OF PULL STATION - ALARM INDICATION, ACTIVATION OF AUDIO/VISUAL AND VISUAL DEVICES. OPERATION OF SMOKE, HEAT, FLOW SWITCH - ALARM INDICATION, ACTIVATION OF AUDIOVISUAL AND VISUAL DEVICES, SHUTDOWN OF AIR HANDLING UNIT(S) IN THE AREA WHERE SIGNAL ORIGINATED. D. DUCT MOUNTED DETECTOR PROVIDE ALARM INDICATION AT THE PANEL ONLY. 2. JURISDICTION: FINAL DECISION ON SYSTEM OPERATION DURING ALARM CONDITION AND LOCATION OF CENTRALIZED PERMANENTLY SUPERVISED LOCATION SHALL BE ESTABLISHED BY OWNER, FIRE MARSHALL AND RULING AUTHORITIES. CONTRACTOR SHALL COORDINATE OPERATION AND LOCATION OF DEVICES ACCORDINGLY BEFOPE COMMENCING WORK. 3. TESTING: UPON COMPLETION OF THE INSTALLATION CONTRACTOR SHALL CONDUCT A COMPLETE TEST OF THE SYSTEM AREA AFFECTING THE TENANT SPACE IN QUESTION IN THE PRESENCE OF THE TENANT, LANDLORD AND FIRE DEPARTMENT'S REPRESENTATIVE(S). ANY CORRECTIONS TO THE SYSTEM REQUIRED FOR FINAL APPROVAL SHALL BE DONE. LEYEN D N: NEW DEVICE E: EXISTING DEVICE ER: EXISTING DEVICE RELOCATED FIRE ALARM NOTES: (EXISTING) 1. FIRE ALARM SYSTEM AND DEVICES TO BE UL LISTED, POWER LIMITED AND COMPATIBLE. 2. VISUAL ALARM PER A.N.S.I. A 117.1.4.26 AND F.B.C. 3. FIRE ALARM SYSTEM SHALL BE TOTALLY SUPERVISED. 4. UPON ACTIVATION OF ANY MANUAL OR AUTOMATIC DEVICE A RED LED SHALL ILUMINATE ZONE IN ALARM AT F.A.C.P., IN ADDITION A LOCAL AUDIBLE ALARM SHALL SOUND THE GENERAL EVACUATION SIGNAL. IF AN INITIATION OR SIGNALING DEVICE IS DISCONNECTED OR WIRING TO THOSE DEVICES ARE CUT AN APPROPRIATE YELLOW TROUBLE LED SHALL ILUMINATE AND AN AUDIBLE SIGNAL SHALL SOUND AT THE F.A.C.P. 5. THE SYSTEM SHALT_ HAVE BATTERY BACK -UP FOR 60 HOURS IN THE SUPERVISORY MODE AND 5 MINUTES MINIMUM IN ALARM. 6. THE INSTALLATION SHALL COMPLY WITH N.E.C. CHAPTER 760 AND N.F.P.A. 72. 7. ALL CEILINGS ARE LESS 10' UNLESS OTHERWISE NOTICE. 8. ALL COMPONENTS ARE LISTED FOR FIRE SERVICE USE. 9. THE EST2 PANEL PROVIDE A CONTROL OF 96 DETECTORS AND 94 MODULES PER CIRCUIT AND PER LOOPS.(SEE CUT - SHEET) 10. HEAT DETECTOR IN ELEVATOR SHAFT SHALL BE FIXED TEMPERATURE. 1357. 24" MAXIMUM DISTANCE FROM SPRINKLER HEAD. PER FIRE DEPARMENT HEAT SENSOR SHALL BE PART OF THE FIRE ALARM SYSTEM, CORRELATE TO A SMART RELAY TO ACTIVATE THE SHUNT TRIP FOR ELEVATORS UPON ALARM ON THE HEAT DETECTOR. FIRE ALARM MUST PROVIDE SUPERVISION FOR POWER AT THE SHUNT TRIP SYSTEM. 11. PROVIDE RELAY FOR FIRE HAT ACTIVATION AT ELEVATOR CAR, UPON ALARM AT SMOKE DETECTORS AT THE MACHINE ROOM & ELEVATOR SHAFT. 12. FIRE ALARM SYSTEM IS A REMOTE MONITORING STATION WITH 2 LINES DIALER. (EXISTING) 13. NOTIFICATION APPLIANCE CIRCUITS (NAC) SHALL BE CLASS "B ", STYLE "Y" WITH AN AVERAGE OUTPUT OF 2 AMPS. 14. SEQUENCE OF ELEVETOR CAPTURE: (EXISTING) A. INITIATION OF SMOKE DETECTOR AT MACHINE ROOM SHALL CAPTURE THE ELEVATOR TO THE FIRST FL. IN ADDITION FIRE HAT AND ELEVATOR WARNING LIGHT AT ELEVATOR CAR SHALL BE ACTIVATED. B. INITIATION OF SMOKE DETECTOR AT FIRST FLOOR ELEVATOR LOBBY SHALL CAPTURE THE ELEVATOR TO THE SECOND FLOOR. C. INITIATION OF HEAT DETECTOR (OPEN AREA) AT SECOND AND THIRD FLOOR ELEVATOR LOBBY SHALL CAPTURE THE ELEVATOR TO THE FIRST FLOOR. D. INITIATION OF SMOKE DETECTOR FROM FOUTH AND FIFTH FLOOR ELEVATOR LOBBY SHALL CAPTURE THE ELEVATOR TO THE FIRST FLOOR. PERMIT AREA DEVICES PERMIT AREA DEVICES SCOPE OF WORK ALARM SYSTEM TO BE INSTALLED IN ACCORDANCE WITH A. EXISTING SUITE 570, TO BE REMODELED. ACCORDING TO FLOOR NFPA72; 70;101• PLAN SHOWN IN THIS DRAWING. CHANGES PROVIDED ARE SHOWN ARE NEW CALCULATIONS. B. THE WORK COVERED BY THIS SECTION OF THE SPECIFICATIONS � � ® mn-- INCLUDES THE FURNISHING OF ALL LABOR, EQUIPMENT, NIIANH- DA-13E COUNTY Ftr.E, DEPtkRTWNT MATERIALS, AND PERFORMANCE OF ALL OPERATIONS IN BLDG, PZ MIT FIRE ALARM CONNECTION WITH THE INSTALLATION OF THE LIFE SAFETY FIRE SUPPRESSION WATER MAIN EXT. SYSTEM AS SHOWN ON THE DRAWINGS AND AS HEREIN SPECIFIED. DATE: ZZ ,2 e 1 BY: C. THE COMPLETE INSTALLATION SHALL CONFORM TO THE APPLICABLE SECTIONS OF NFPA -72, LOCAL CODE REQUIREMENTS NATIONAL ELECTRICAL CODE. D. FURNISH AND INSTALL A COMPLETE LIFE SAFETY SYSTEM AS DESCRIBED HEREIN AND AS SHOWN ON THE PLANS: TO BE 2 WIRED, CONNECTED, AND LEFT IN FIRST CLASS OPERATING CONDITION. THE SYSTEM SHALL USE CLOSED LOOP INITIATING EXISTING OFFICE 109 S 75CD S11C -3A -_� STORAGE 108 S11 C-2A - , 75CD NS exisrc STORAGE LOUNGE AREA 105 75CD S11C -3 m RFF ER F A 75CD S 11C -2 CONFERENCE RM 109 EXISTING OFFICE 109 75CD S11C -4 S CR -2 RECEPTION AREA & HALLWAY A,1S 107 S11 C -1 rDD--' E E 75CD CR- F E JILL'S OFFICE 104 L ST# 1 1 C (1.55A) OFFICE B 102 OFFICE B 102 I i OFFICE A 101 2A,1S-/ N.I.C. A,1S TO S #5 FIRE ALARM SUITE 570 - 5th FLOOR SC:1 /8 " =1' -0" 2 KEY -PLAN N.T.S EXISTING FIRE ALARM DEVICE LEGEND (EXISTING) I3PS#jT#1 EDP #3 EOL ST#6 EOL ST#2 EOL ST 4 EOL ST #7 EOL ST#2A EOL ST 5 EOL ST #8 EOL HORN#1 EOL HORN#2 EOL HORN#3 DD -7 DD -8 DD -9 DD -10 A,1P Lo R R -2 CR CR -4 CR -5 CR -6 CR -7 CR -8 I CR -10 CT -1 CT -2 WT -1 CT -3 CT -4 AC -6 AC -5 AC -4 AC -3 AC -2 AC -1 AC -10 AC -9 / AC -7 TO FACP EWL BACK FLOW 100 PANEL "4Hr. DEDICAIT MAIN RISER PREVENTER BREAKER 20A.1P.120V VALVE CR -11 CKT -4 (FACP.BPS /1,2.3) 1ST FLOOR PARKING EXISTING RE ALARM RISER: N.T.S System No. C -AJ -1149 F Rating - 2 Hr T Rating - 0 Hr L Rating At Ambient - Less Than 1 CFM/sq ft L Rating At 400 F - 4 CFM /sq ft A 2 0 4 4 i� A 3 1 SECTION A -A 1. Floor or Wall Asmmby - Wn 4-1/2 iR thick reinforced i¢drei t or nand -150 ( 100 -150 pd) concrete. Mal may abo be cwabw ed of any UL Classified Concrete Blocks '. Max darn of opsnig is 12 h See Concrete Blacks (Wo category In the rre Resistance Mwtay for mmes of nxrnlachsers. 2 Rmgh Penetrants - One reEdie pipe, cmdLft or tubig to be Mailed within the fresfnp system. Pipe, conduit or bbog to be rigidy supported on bath sides of floor or wall assembly. The oenular space aldl be 0 Ea (point contact) to mac 1 -1/4 in. The falkrwirg Lypse and sim of nstafia pipes, cordults or tubig mq be used: A Steel P'pe - Nom 10 k dam (err smaller) Sd ed4e 10 (or heavier) $test pipe. B. Conduit - Nom 4 in dam (o smaller) shed ebcbicd meiotic tAig or steal conduit C. Capper Tubirg - Nam 4 R dam (or scaler) Type L (or heavier) copper hii*4 D. plpCopper pipe - Nom 4 iii dam (or emaler) RM*r (or heavier) copper 3. Pocking Material - M'n 3 in. Nc nm of mn 4 pd n"d wool bad irmdatim for nom 4 in. don (and rider) ppes, corndulls or Ubp and a min 4 kL thidasse of min 4 pd mrsrd wool butt kw*bw for pipe peeler then ram 4 inn dam, frmly pocked into ope ling as a pemnasrrt form. Pod&q material to be receaad from bop surface of floor or from both srfotes of wall as regkired to accommodate the rogk W th ch" Of fill material 4. nil. Void or Cavity Matedar - Sealant - Min 1/2 h thktosss of h7 material applied waft the omalus, Ouch wlib the top sLdwe of floor or both surfaces of wall At the point of cu. koafan between pipe and =cute, a min 1/2 in. can bead of fill material stern be applied at IN /pqe kW000 on the top 20ace of floor and on bath surfaces of wall. HIL11 CONS1i XWN MICALS. Blv OF NIL11 INC - CP601S. 016M or FS -flirt Sedmt (Ibtc LL RaUrxp op* a when FS-W Sealant is used). UL m ] � -P Fl Ia RESP S1SiFY5 Cr O U E - J SEQUENCE OF OPERATION 1. SEQUENCE OF OPERATION SHALL AS FOLLOWS: A. OPERATION OF TAMPER, SWITCH - SUPERVISORY INDICATION. C. OPERATION OF PULL STATION - ALARM INDICATION, ACTIVATION OF AUDIO/VISUAL AND VISUAL DEVICES. OPERATION OF SMOKE, HEAT, FLOW SWITCH - ALARM INDICATION, ACTIVATION OF AUDIOVISUAL AND VISUAL DEVICES, SHUTDOWN OF AIR HANDLING UNIT(S) IN THE AREA WHERE SIGNAL ORIGINATED. D. DUCT MOUNTED DETECTOR PROVIDE ALARM INDICATION AT THE PANEL ONLY. 2. JURISDICTION: FINAL DECISION ON SYSTEM OPERATION DURING ALARM CONDITION AND LOCATION OF CENTRALIZED PERMANENTLY SUPERVISED LOCATION SHALL BE ESTABLISHED BY OWNER, FIRE MARSHALL AND RULING AUTHORITIES. CONTRACTOR SHALL COORDINATE OPERATION AND LOCATION OF DEVICES ACCORDINGLY BEFOPE COMMENCING WORK. 3. TESTING: UPON COMPLETION OF THE INSTALLATION CONTRACTOR SHALL CONDUCT A COMPLETE TEST OF THE SYSTEM AREA AFFECTING THE TENANT SPACE IN QUESTION IN THE PRESENCE OF THE TENANT, LANDLORD AND FIRE DEPARTMENT'S REPRESENTATIVE(S). ANY CORRECTIONS TO THE SYSTEM REQUIRED FOR FINAL APPROVAL SHALL BE DONE. LEYEN D N: NEW DEVICE E: EXISTING DEVICE ER: EXISTING DEVICE RELOCATED FIRE ALARM NOTES: (EXISTING) 1. FIRE ALARM SYSTEM AND DEVICES TO BE UL LISTED, POWER LIMITED AND COMPATIBLE. 2. VISUAL ALARM PER A.N.S.I. A 117.1.4.26 AND F.B.C. 3. FIRE ALARM SYSTEM SHALL BE TOTALLY SUPERVISED. 4. UPON ACTIVATION OF ANY MANUAL OR AUTOMATIC DEVICE A RED LED SHALL ILUMINATE ZONE IN ALARM AT F.A.C.P., IN ADDITION A LOCAL AUDIBLE ALARM SHALL SOUND THE GENERAL EVACUATION SIGNAL. IF AN INITIATION OR SIGNALING DEVICE IS DISCONNECTED OR WIRING TO THOSE DEVICES ARE CUT AN APPROPRIATE YELLOW TROUBLE LED SHALL ILUMINATE AND AN AUDIBLE SIGNAL SHALL SOUND AT THE F.A.C.P. 5. THE SYSTEM SHALT_ HAVE BATTERY BACK -UP FOR 60 HOURS IN THE SUPERVISORY MODE AND 5 MINUTES MINIMUM IN ALARM. 6. THE INSTALLATION SHALL COMPLY WITH N.E.C. CHAPTER 760 AND N.F.P.A. 72. 7. ALL CEILINGS ARE LESS 10' UNLESS OTHERWISE NOTICE. 8. ALL COMPONENTS ARE LISTED FOR FIRE SERVICE USE. 9. THE EST2 PANEL PROVIDE A CONTROL OF 96 DETECTORS AND 94 MODULES PER CIRCUIT AND PER LOOPS.(SEE CUT - SHEET) 10. HEAT DETECTOR IN ELEVATOR SHAFT SHALL BE FIXED TEMPERATURE. 1357. 24" MAXIMUM DISTANCE FROM SPRINKLER HEAD. PER FIRE DEPARMENT HEAT SENSOR SHALL BE PART OF THE FIRE ALARM SYSTEM, CORRELATE TO A SMART RELAY TO ACTIVATE THE SHUNT TRIP FOR ELEVATORS UPON ALARM ON THE HEAT DETECTOR. FIRE ALARM MUST PROVIDE SUPERVISION FOR POWER AT THE SHUNT TRIP SYSTEM. 11. PROVIDE RELAY FOR FIRE HAT ACTIVATION AT ELEVATOR CAR, UPON ALARM AT SMOKE DETECTORS AT THE MACHINE ROOM & ELEVATOR SHAFT. 12. FIRE ALARM SYSTEM IS A REMOTE MONITORING STATION WITH 2 LINES DIALER. (EXISTING) 13. NOTIFICATION APPLIANCE CIRCUITS (NAC) SHALL BE CLASS "B ", STYLE "Y" WITH AN AVERAGE OUTPUT OF 2 AMPS. 14. SEQUENCE OF ELEVETOR CAPTURE: (EXISTING) A. INITIATION OF SMOKE DETECTOR AT MACHINE ROOM SHALL CAPTURE THE ELEVATOR TO THE FIRST FL. IN ADDITION FIRE HAT AND ELEVATOR WARNING LIGHT AT ELEVATOR CAR SHALL BE ACTIVATED. B. INITIATION OF SMOKE DETECTOR AT FIRST FLOOR ELEVATOR LOBBY SHALL CAPTURE THE ELEVATOR TO THE SECOND FLOOR. C. INITIATION OF HEAT DETECTOR (OPEN AREA) AT SECOND AND THIRD FLOOR ELEVATOR LOBBY SHALL CAPTURE THE ELEVATOR TO THE FIRST FLOOR. D. INITIATION OF SMOKE DETECTOR FROM FOUTH AND FIFTH FLOOR ELEVATOR LOBBY SHALL CAPTURE THE ELEVATOR TO THE FIRST FLOOR. PERMIT AREA DEVICES PERMIT AREA DEVICES SCOPE OF WORK ALARM SYSTEM TO BE INSTALLED IN ACCORDANCE WITH A. EXISTING SUITE 570, TO BE REMODELED. ACCORDING TO FLOOR NFPA72; 70;101• PLAN SHOWN IN THIS DRAWING. CHANGES PROVIDED ARE SHOWN ARE NEW CALCULATIONS. B. THE WORK COVERED BY THIS SECTION OF THE SPECIFICATIONS � � ® mn-- INCLUDES THE FURNISHING OF ALL LABOR, EQUIPMENT, NIIANH- DA-13E COUNTY Ftr.E, DEPtkRTWNT MATERIALS, AND PERFORMANCE OF ALL OPERATIONS IN BLDG, PZ MIT FIRE ALARM CONNECTION WITH THE INSTALLATION OF THE LIFE SAFETY FIRE SUPPRESSION WATER MAIN EXT. SYSTEM AS SHOWN ON THE DRAWINGS AND AS HEREIN SPECIFIED. DATE: ZZ ,2 e 1 BY: C. THE COMPLETE INSTALLATION SHALL CONFORM TO THE APPLICABLE SECTIONS OF NFPA -72, LOCAL CODE REQUIREMENTS NATIONAL ELECTRICAL CODE. D. FURNISH AND INSTALL A COMPLETE LIFE SAFETY SYSTEM AS DESCRIBED HEREIN AND AS SHOWN ON THE PLANS: TO BE 2 WIRED, CONNECTED, AND LEFT IN FIRST CLASS OPERATING CONDITION. THE SYSTEM SHALL USE CLOSED LOOP INITIATING EXISTING OFFICE 109 S 75CD S11C -3A -_� STORAGE 108 S11 C-2A - , 75CD NS exisrc STORAGE LOUNGE AREA 105 75CD S11C -3 m RFF ER F A 75CD S 11C -2 CONFERENCE RM 109 EXISTING OFFICE 109 75CD S11C -4 S CR -2 RECEPTION AREA & HALLWAY A,1S 107 S11 C -1 rDD--' E E 75CD CR- F E JILL'S OFFICE 104 L ST# 1 1 C (1.55A) OFFICE B 102 OFFICE B 102 I i OFFICE A 101 2A,1S-/ N.I.C. A,1S TO S #5 FIRE ALARM SUITE 570 - 5th FLOOR SC:1 /8 " =1' -0" 2 KEY -PLAN N.T.S EXISTING FIRE ALARM DEVICE LEGEND (EXISTING) SYMBOL DESCRIPTION CATALOG NUMBER MOUNTING HEIGHT ®oR ®E SMOKE DETECTOR SIGA -PS / SIGA -SB t ID HEAT DETECTOR SIGA -HRS 11- Do-- DUCT DETECTOR SIGA -PS / SIGA -DH SIGA -SB SIGA -LED 6261006 "' I ® FM_Rj CONTROL RELAY MULTI - VOLTAGE CONTROL RELAYS SIGA -CR MR -101 I 75CD STROBE (75CD) G1F -VM 80" AFF TO BOTTOM 1 75CD HORN /STROBE (75CD) G1F -HDVM 80" AFF TO BOTTOM 110CD HORN /STROBE (11OCD) 757 -8A -T 80" AFF TO BOTTOM 110CD STROBE (11 OCD)(WEATHERPROOF) CS405-8A-TW/LKW- 1 /449 80" AFF TO BOTTOM t WIR ID HORN /STROBE(11 OCD)(WEATHERPROOF) 757- 8A- TW /757A -WBW 80" AFF TO BOTTOM WP PULL STATION (WEATHERPROOF) SG -32 48" AFF TO CENTER D MANUALL PULL STATION SIGA -270 48" AFF TO CENTER ® FIRE ALARM JUNCTIONBOX SIZE AS NEEDED ® BOOSTER POWER SUPPLY BPS -10 Q ® FIRE ALARM CONTROL PANEL EST -2 (ANALOG CONTROLPANEL) Etivl ELEVATOR WARNING LIGHT EL -1 72" AFF TO CENTER ® © WATERFLOW/TAMPER MODULE TAMPER SWITCH SIGA -WTM BY OTHERS ©S FLOW SWITCH BY OTHERS 3 ® CONTROL MODULE SIGA -CT1 ® SIGNAL MODULE SIGA -CC1 C ® CONTROL MODULE SIGA -CT2 DEVICE CIRCUITS WITH INDIVIDUAL ZONE SUPERVISION. E. ALL PANELS AND PERIPHERAL DEVICES SHALL BE THE STANDARD - CEILING PRODUCT OF A SINGLE MANUFACTURER AND SHALL DISPLAY THE 3' -2" MIN. MANUFACTURER'S NAME ON EACH COMPONENT. THE CATALOGUE SMOKE NUMBERS SPECIFIED UNDER THIS SECTION ARE THOSE OF (EST) DETECTOR A/C EDWARDS SYSYTEM TECHNOLOGY AND CONSTITUTE THE TYPE, DIFFUSER AND /OR FLUORECENT LIGHT QUALITY OF ALARM, MATERIAL, AND OPERATING FEATURES DESIRED. SMOKE DETECTOR MOUNTING DETAIL F. MAIN PANEL EDWARDS EST 2. WORK BE DONE WITH N.T.S GENESIS SERIES AND SIGNATURE INITIATING DEVICES. ER =MEANS EXISTING TO RELOCATED E =MEANS EXISTING TO REMAIN PLANS ARE BASED ON CONTRACT DRAWINGS PROVIDED BY ENGINEER ON RECORD. TO THE BEST OF MY KNOWLEDGE I'M PROVIDING THE DESIGN OF CONNECTIONS TO MAIN FIRE ALARM SYSTEM AND PERIPHERAL DEVICES PER MANUFACTURER RECOMMENDATION, INCLUDING DROP OF VOLTAGE AND BATTERY CALCULATIONS l 11 r'- fY1 "' w '^ L U- O 1 W Q Ca U U IQ U ^ I O w _v W V) Ln O � N L^ Q W 11. � 0 m 3 C Q) C L Z 0) p W W W W F_ Z CD Z CD 0 U) Li W W W W m CT] W � 0 0 Q [ to CD \ �aaaW V i 0) _0 0 O1 C: a-+ V N Q% CO Ln ^ In i1 LA 0 r In to N 00 EN .� 4-J 00 LJi 00 O Vi to tJ1 CJ QJ v M Cfi C) F- LL. O "L N Q� W E. BORJA P.E.# 36040 ELECTRICAL CAD DATE: 4/13/05 SCALE: AS SHOWN EB# 000 7048 SHEET: FA_j OF � j