Loading...
08-1179-006MECHANICAL NOTES 1. VERIFY ALL CONDITIONS AND DIMENSIONS AT JOB SITE AND COORDINATE WITH ARCHITECTURAL PLANS. 2. UNLESS OTHERWISE �OIT�ED, CONTRACTOR SHALL FURNISH AND INSTALL ALL EQUIPMENT AND MATERIAL REQUIRED FOR A COMPLETE AND WORKABLE SYSTEM, PAY FOR ALL PERMITS AND CHARGES REQUIRED AND COMPLY WITH CITY AND OTHER GOVERNING CODES AND ORDINANCES. 3. CONTRACTORS SHALL GUARANTEE THE WORK FOR ONE YEAR. 4. ALL H.V.A.C. EQUIPMENT SHALL BE AS SCHEDULED ON THE DRAWINGS. ANY SUBSTITUTIONS MUST BE APPROVED IN WRITING. 5. ANY ROOF PENETRATIONS TO BE COORDINATED WITH LANDLORD'S ROOFING CONTRACTOR AND SHALL INCLUDE ALL WORK REGARDING ROOFING AND ROOF PENETRATIONS IN HIS BID. 6. DUCT WORK: A. DUCT WORK SHALL BE 1" MINIMUM INSULATED DUCTBOARD AS MANUFACTURED BY JOHNS (MANVILLE OR EQUAL FOR MAIN SUPPLY RUNS AND INSULATED FLEXDUCT FOR GRILLE FEEDERS. C. CONTRACTOR IS TO PROVIDE AND INSTALL AIR SCOOPS, EXTRACTORS AND /OR SPUTTER DAMPERS WITH OPERATOR AND LOCKING QUADRANTS AS INDICATED. F. FURNISH AND INSTALL ALL AIR DISTRIBUTION DEVICES AND ACCESSORIES AS INDICATED ON THE DRAWINGS, DEVICES SHALL BE AS (MANUFACTURED BY NAILOR HART, OR EQUAL., AS FOLLOWS: COUNG SUPPLY — 4310 AND COUNG RETURN— RAFG/TB. 7 MECHANICAL CONTRACTOR TO BALANCE ENTIRE SYSTEM AT THE COMPLETION OF PROJECT TO THE SATISFACTION OF THE OWNER AS REQUIRED. REBALANCING MAY INCLUDE ADJUSTING CFM IN VARIOUS AREAS. s (EF-0 NUTONE, 100 CFM EXHAUST FAN OR EQUAL, COLOR —WHITE HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR YES MANUFACTURER FIRE DAMPER CONDENSING UNIT MODEL No NO SMOKE DAMPER E09OA —B NO FIRE RATED ENCLOSURE AIR SUPPLY CF� NO FIRE RATED FLOOR /ROOF CEILING ASSEMBLY 300 NO FIRE STOPPING MOTOR HORSEPOWER NO SMOKE CONTROL 76.9/64.4 NO EXISTING TO REMAIN AIR CONDITIONING UNITS DESIGNATION AC— AREA SERVED STORE MANUFACTURER TRA E CONDENSING UNIT MODEL No TTA072C300A AIR HANDUNG UNIT MODEL No. E09OA —B AIR HANDLING U IT i j � j AIR SUPPLY CF� 2400 OUTSIDE AIR CFM 300 EXTERNAL STATIC PRESSURE H2O .75 MOTOR HORSEPOWER I ENT AIR *F DB B 76.9/64.4 ELECTRICAL SE CE A AILABLE 208/3/60 CO DE SI ING UNIT TOTAL SENSIBLE HEAT BTU HR 56,740 GRAND TOTAL HEAT BTU H R 72,800, 10 rULL LOAD AMPS 22.2 ELECTRICAL SE CE AVAILABLE 208/3/60 CCESSORIES HEATER KW. 10 PROVIDE BUILT IN CIRCUIT BREAKER FOR ALL AHU'S 5 EMPLYEE CALCULATION . X 5 PERSON /1000 SQ FT. = 20 0/A = 20 PERSONS X 15 CFM /PERSON = 300 CM THREADED SMOKE DETECTOR MOISTURE DETECTOR TO SHUT OFF UNIT AND SAUII, VISUAL AUDIBLE STRUCTURE ISOLATOR AHU —'11/4* R /ADUCT OVERFLOW GALV. PAN OVERHANG 4" ALL AROUND UNI EXISTING TO REMAIN AHU MOUNTING DETAIL SCALE.. 1/20 - 1' -0" NOTE SUPPORT ON ROOF EXISTING. CONTRACTOR TO VERIFY EXACT LOCATION PRIOR TO PRICING JOB FLASHING 11 n R/A REGISTER 6X3 STEEL CHANNEL FRAME O.B.D 0/A DUCT COUNG O 1/8" SS CABLE /WRAP AROUND U R BOLTED TO E ,APADSn4 N MIN. ,,STEEL PLATE WELDED TO PIPE 3" STEEL PIPE SUPPORT 18" 1 t O 36" 0/C ANCHOR TO SLAB ?. • . °::. �... • ' _ - .• .. ° • : 4a '. WITH 1/4"X1 -1/2' TAPCON' ::° t' ' "� •.` ,' _•: -i-— ROOF STRUCTURE • ° :.• 4 MINIMUM '• : •.° • a . ' •': • • • .• : • ' °. � • a • •• EXISTING TO REMAIN COND. UNIT MOUNTING DETAIL SCALE: 1" - 1' -0" EXISTING 1 -1 /2" CONDENSATE IN CLG. SPACE VERIFY EXACT LOCATION NEW I TAP REF. UNES 1 -318" SUCTION 7/8 UQUID EXISTING HV,4G FLOOf;R FL,4N SCAM 1/44.11 -08 EXISTING REF. ONES UP TO CONDENSING UNIT ON ROOF SEE DETAIL Dee and L Hair Studio Interior Improvements SUITE 135, GROUND FLOOR, PLAZA 57 p� 7301 S.W. 57TH COUfI 1 CITY OF SOUTH MIAMI SOUTH MIAMI, FLORIDA 33143 31" 46" CHANDLER AND ASSOCIATES PA AA 0003060 JAS� R CL�IDIFl, AiA AR NQ SOUI�I MUIIVII' FLORIDA X143 TEL (" 66g-']� FAX 0" 669-7593 VAM.CHArin COM CONDENSING DATE UNIT (330 LEIS) REVISION 6X3 STEEL CHANNEL FRAME O.B.D 0/A DUCT COUNG O 1/8" SS CABLE /WRAP AROUND U R BOLTED TO E ,APADSn4 N MIN. ,,STEEL PLATE WELDED TO PIPE 3" STEEL PIPE SUPPORT 18" 1 t O 36" 0/C ANCHOR TO SLAB ?. • . °::. �... • ' _ - .• .. ° • : 4a '. WITH 1/4"X1 -1/2' TAPCON' ::° t' ' "� •.` ,' _•: -i-— ROOF STRUCTURE • ° :.• 4 MINIMUM '• : •.° • a . ' •': • • • .• : • ' °. � • a • •• EXISTING TO REMAIN COND. UNIT MOUNTING DETAIL SCALE: 1" - 1' -0" EXISTING 1 -1 /2" CONDENSATE IN CLG. SPACE VERIFY EXACT LOCATION NEW I TAP REF. UNES 1 -318" SUCTION 7/8 UQUID EXISTING HV,4G FLOOf;R FL,4N SCAM 1/44.11 -08 EXISTING REF. ONES UP TO CONDENSING UNIT ON ROOF SEE DETAIL Dee and L Hair Studio Interior Improvements SUITE 135, GROUND FLOOR, PLAZA 57 p� 7301 S.W. 57TH COUfI 1 CITY OF SOUTH MIAMI SOUTH MIAMI, FLORIDA 33143 Them plans are for bukft department review. They are not to be construed as ftnei construction documents urd al vale are obtained and comments are ted In these a drawkgs. Due to the variations in titerpretations of the code that occur In different nvskipaltles final approval and review Is needed to assure compliance with the applicable Codes and standards. ANTONIO FRANYIE PE #11640 MECH VIVIANA FRANYIE = PE #49985 ME r•�``�. ,,•' - = -. ` ! ;,;. , -- 10610 NW 27 Street, Miami FL 33172 =, �y` °� _TEL: (305) 592 -1360 FAX: (305) 594 -9279 vuww.fran ieen ineers.com CHANDLER AND ASSOCIATES PA AA 0003060 JAS� R CL�IDIFl, AiA AR NQ SOUI�I MUIIVII' FLORIDA X143 TEL (" 66g-']� FAX 0" 669-7593 VAM.CHArin COM NO. DATE REVISION NO. DATE REVISION �� �� HVAC R OM DA'� DATES September 26, 2008 PROJECT NO` 20089 DRAWINC3 N0: —� i j � j _ i 5 ��l) c ` �c -� 1, ` � • w N pe �VN ID ATE 10/,al /0S JOB NUMBER 08 -164