12-1332-007
m I c i u ELECTRICAL DEMOLITION PLAN (SEE CONSTRUCTION NOTES) SCALE:1 /4" GENERAL NOTES 1— GENERAL CONDITIONS: THE GENERAL CONDITIONS FORM A PART OF THE SPECIFICATIONS FOR THIS TRADE. EACH SUB — CONTRACTOR MUST READ GENERAL CONDITIONS, AS WELL AS THE SPECIFICATIONS FOR WORK OF OTHER TRADES AND TO ASCERTAIN WHAT WORK AND MATERIALS HE MUST SUPPLY TO THE OTHER CONTRACTORS, 2— SITE INVESTIGATION: IT SHALL BE THE RESPONSABILITY OF BIDDERS TO VISIT THE SITE AND TO ACQUAINT THEMSELVES WITH AL INFORMATION REGARDING THE NEW BUILDING. 3— DESIGN: THE INSTALLATION OF THE WIRING SYSTEM SHOWN ON THESE DWGS. SHALL CONFORM TO THE REGULATIONS OF LOCAL CODES AND ORDINANCES, N.E.C. AND LOCAL UTILITY COMPANIES. 4— MINIMUM STANDARDS: THE MATERIAL, INSTALLATIONS AND WORKMANSHIP FURNISHED UNDER THIS SECTION SHALL CONFORM TO THE REQUIREMENTS OF LOCAL CODES AND N.E.G., ALL MATERIALS USED SHALL BE LISTED OR BEAR U.L APPROVAL. 5— GUARANTEE: THIS SUB — CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE THAT ALL WORK EXECUTED UNDER THIS CONTRACT, SHALL BE FREE FROM DEFECTS OR WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR, AT CONTRACTOR'S EXPENSE, REPAIR AND REPLACE ALL WORK WHICH BECOMES DEFECTIVE DURING THE TIME OF THE GUARANTEE. 6— RACEWAYS AND FITTINGS: a RIGID GALVANIZED : 1 -1/2" OR LARGER , AND IN SLAB ABOVE GRADE. b) PVC : IN OR UNDER GND FLOOR SLAB c) EMT : ALL OTHER LOCATION. d ARMORED CABLE, MC: ABOVE SLAB, BRANCH CIRCUITS ONLY. e FITTINGS: TO MATCH APPROVED RACEWAY . 7— CONDUCTORS: THE MINIMUM CONDUCTOR NO.12 SOLID CU. TYPE "THW" INSULATION. ALUMINUM CONDUCTOR ALLOWED ONLY WHERE INDICATED ON DRAWINGS. 8— ALL EQUIPMENT LISTED ON DWGS. BY CATALOG NO. SHALL BE LIMITED TO THE KIND AND MANUFACTURE LISTED. NO SUBSTITUTION SHALL BE ALLOWED UNLESS APPROVED BY THE ENGINEER. A WRITTEN GUARANTEE OF THREE YEARS AND CREDIT FROM BASIC BID SHALL BE SUBMITTED WITH SHOP DRAWINGS. 9— CONTRACTOR TO INSTALL AND /OR CONNECT ALL EQUIPMENTS AND CONTROLS SUPPLIED BY OWNER, OR ANY OTHER TRADE, SEE OTHER TRADES DRAWINGS AND SPECIFICATIONS. 10— ALL FEEDERS AND BREAKERS SHALL BE COORDINATED WITH EQUIPMENT'S PLATE AT SITE. GENERAL CONSTRUCTION NOTES - 1. ALTERATIONS TO EXISTING WORK BEING OF SUCH NATURE THAT ALL FACETS OF THE WORK ARE IMPOSSIBLE TO DETAIL AND SPECIFY. IT IS THEREFORE THE RESPONSABILITY OF THE CONTRACTOR TO CARE- FULLY EXAMINE THE BUILDING AND THE GROUNDS AND FAMILIARIZE HIMSELF WITH THE CONDITIONS AND RELATE THESE CONDITIONS TO THE SCOPE OF THE PROPOSED WORK PRIOR TO BIDDING. 2. ANY EXISTING INSTALLATION PROBLEMS OR EXISTING CODE VIOLATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT /ENGINEER PRIOR TO BIDDING. 3. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXISTING ELECTRICAL. INTALLATION, THE WORKING CONDITIONS OF THE EXISTING ELECTRICAL PANELS, LIHGT, FIRE ALARM SYSTEM AND DEVICES AND A WRITTEN REPORT TO THE OWNER WITH THE BID PROPOSAL 4. ANY ELECTRICAL WORK WHICH WILL INTERFERE WITH THE BUILDING TENANTS NORMAL OPERATION SHALL BE NOTIFIED IN ADVANCE TO THE BUILDING OWNER OR MANAGER AND SHALL BE DONE AFTER BUILDING NORMAL OPERATION HOURS OR ON WEEKENDS. 5. THE ELECTRICAL CONTRACTOR SHALL PROVIDE TO THE OWNER AT THE END OF THE WORK A SET OF AS BUTT DRAWINGS. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AT EACH EXISTING ELECTRICAL PANELS A WRITTEN PANEL SCHEDULE WITH THE PROPER TYPE OF LOAD IDENTINFICATION AND THE ROOM NUMBER THAT ARE FEEFDING. 6. ALL DEVICES, EQUIPMENT, ETC. WHETHER SHOWN OR NOT, TO BE PROPERLY CONNECTED ELECTRICALLY, UNLESS SPECIFICALLY NOTED TO BE REMOVED. C °6 C WAITING ROOM X102 ELECTRICAL FLOOR PLAN SCALE: 1/4" irlllli /►r 'rI 0��� L P f-OI ® f 6 f C3 • rA rP'E Nt. (1639• OF •,�Az s,s®NA.. EN `` rrrntt�� LIGHTING CEILING PLAN SCALE: 1/4" 1 ❑B N0, 10 -091 LOBBY RPJ, Inc. � FAOd1ar11C��eOC1rIC>'J) L'Of1ll/flro EY1Gif10Efa STATE OF FL CO. NO. (00006513) P.E. NO. (16395) i' t y r� 4977 S.W. 74th COURT MIAMI, FL. 33155 �- PHONE. (305) 666 -2131 FAX: (305) 666 -0131 E -Mol: rpjArpjmep.com ELECTRICAL FLOOR PLAN NOTES PROVIDE FOUR NEW CONV. DUPLEX RECEPTACLE TO BE CONNECTED WITH 2 #12 THWN CU IN 1/2" TO EXISTING 1P -20 AMPS SPARE CIRCUIT BREAKER AT EXISTING ELECTRICAL PANEL ® PROVIDE THREE WALL MOUNTED J —BOX FOR THE CONNECTION OF THE MILLWORK DISPLAY LIGHTING. COORDINATE FINAL LOCATION AND CONNECTIONS TO THE DISPLAY LIGHT FIXTURES AS PER INTERIOR DESIGNER DETAILS AND FINAL MILLWORK DISPLAY SHOP DRAWING PRIOR TO ROUGH —IN. ELECTRICAL CONTRACTOR SHALL CONNECT THE NEW MILLWORK DISPLAY LIGHTING WITH 2 # 12 THWN CU IN 1 / 2" C. TO EXISTING 1P -20 AMPS CIRCUIT BREAKER. ® ELECTRICAL CONTRACTOR SHALL PROVIDE NEW LIGHT SWITCH FOR EACH MILLWORK DISPLAY CIRCUIT AND CONNECT IT WITH 2 # 12 THWN CU IN 1 / 2" TO EACH WILLWORK DISPLAY— J—BOX. FINAL LOCATION OF THE SWITCHES SHALL AS SELECTED BY THE INTERIOR DESIGNER. COORDINATE WITH INTERIOR DESIGNER DRAWINGS AND SPECS. EQ PROVIDE FLOOR MOUNTED J —BOX UNDER P.O.S. CASH REGISTER BUILT —IN DESK. WITH 3/4" EMPTY CONDUIT WITH PULL STRINGS TO BE RUN UNDER FLOOR TO THE NEAREST PARTITION AND UP TO CEILING SPACE FOR DATA /COMM. CABLE CONNECTIONS. O PROVIDE FLOOR MOUNTED J —BOX WITH TWO CONV. DUPLEX RECEPTACLE UNDER P.O.S. CASH REGISTER BUILT —IN DESK. TO BE CONNECTED WITH 4 112 THWN IN 1 / 2" C. (1 LINE, 1 NEUTRAL, 1 GROUND AND 1 I.G. WIRES) TO A NEW 1P -20 AMPS CIRCUIT BREAKER TO BE PROVIDED AT EXISTING SPACE AT THE EXISTING ELECTRICAL PANEL. © FINAL LOCATION OF THE TWO FLOOR MOUNTED J —BOXES SHALL BE COORDINATED WITH THE INTERIOR DESIGNER PRIOR TO ROUGH —IN. LIGHTING CEILING PLAN NOTES �A PROVIDE NEW LED EXIT SIGN WITH BATTERY PACK TO BE CONNECTED AHEAD OF- SWITCH, PHILIPSAIGHTOLIER EX2— OUTLOOK �B} PROVIDE RECESSED EMERGENCY LIGHT WITH BATTERY PACK TO BE CONNECTED AHEAD OF SWITCH. PHILIPSAIGHTOLIER SOLUTION 2 SERIES. QC PROVIDE NEW FLUORESCENT COVE LIGHTS. SEE MOUNTING DETAIL ON INTERIOR DESIGNER DRAWINGS. LIGHTOLIER T5 STAGGERED STRIP SERIES. QD PROVIDE J -BOX FOR NEW FLUORESCENT COVE LIGHT. FINAL LOCATION TO BE COORDINATE WITH INTERIOR DESIGNER FOR AN ACCESIBLE LOCATION LIGHTOLIER T5 STAGGERED STRIP SERTIES. PROVIDE 2 #12 THWN CU IN 1/2" C. TO EXISTING 1P -20 AMPS SPARE CIRCUIT BREAKER AT EXISTING PANEL. Q PROVIDE 2 #12 THWN CU IN 1/2" C. TO NEW LIGHTING SWITCH 0 PROVIDE 2 #12 THWN CU IN 1/2" C. TO NEW LIGHTING SWITCH "b" (H PROVIDE 2 #12 THWN CU IN 1/2" C. TO NEW LIGHTING SWITCH "c" IQ PROVIDE 2 #12 THWN CU IN 1/2" C. TO NEW LIGHTING SWITCH "d" Q PROVIDE 2 #12 THWN CU IN 1/2" C. TO NEW LIGHTING SWITCH "e" Q NEW LIGHTING SWITCH BANK.VERIFY FINAL LOCATION AND SWITCH TYPE AND COLOR WITH INTERIOR DESIGNER PRIOR TO ROUGH -IN. QM PROVIDE NEW RECESSED DOWN LIGHT WITH LED LAMPS. TO BE SELECTED BY INTERIOR DESIGNER (120V, LIGHTOLIER CALCULATE) Q PROVIDE NEW DECORATIVE LIGHT FIXTURE TO BE SELECTED BY INTERIOR DESIGNER. APP VED B , revi si ons : D aY: South Miami Advanced - I Center for Surgery I D QI w oar : DR. ALAN SERURE I SUITE 200 z PLACE 11/23112 ELECTRICAL FLOOR PLAN SCALE: 1/4" irlllli /►r 'rI 0��� L P f-OI ® f 6 f C3 • rA rP'E Nt. (1639• OF •,�Az s,s®NA.. EN `` rrrntt�� LIGHTING CEILING PLAN SCALE: 1/4" 1 ❑B N0, 10 -091 LOBBY RPJ, Inc. � FAOd1ar11C��eOC1rIC>'J) L'Of1ll/flro EY1Gif10Efa STATE OF FL CO. NO. (00006513) P.E. NO. (16395) i' t y r� 4977 S.W. 74th COURT MIAMI, FL. 33155 �- PHONE. (305) 666 -2131 FAX: (305) 666 -0131 E -Mol: rpjArpjmep.com ELECTRICAL FLOOR PLAN NOTES PROVIDE FOUR NEW CONV. DUPLEX RECEPTACLE TO BE CONNECTED WITH 2 #12 THWN CU IN 1/2" TO EXISTING 1P -20 AMPS SPARE CIRCUIT BREAKER AT EXISTING ELECTRICAL PANEL ® PROVIDE THREE WALL MOUNTED J —BOX FOR THE CONNECTION OF THE MILLWORK DISPLAY LIGHTING. COORDINATE FINAL LOCATION AND CONNECTIONS TO THE DISPLAY LIGHT FIXTURES AS PER INTERIOR DESIGNER DETAILS AND FINAL MILLWORK DISPLAY SHOP DRAWING PRIOR TO ROUGH —IN. ELECTRICAL CONTRACTOR SHALL CONNECT THE NEW MILLWORK DISPLAY LIGHTING WITH 2 # 12 THWN CU IN 1 / 2" C. TO EXISTING 1P -20 AMPS CIRCUIT BREAKER. ® ELECTRICAL CONTRACTOR SHALL PROVIDE NEW LIGHT SWITCH FOR EACH MILLWORK DISPLAY CIRCUIT AND CONNECT IT WITH 2 # 12 THWN CU IN 1 / 2" TO EACH WILLWORK DISPLAY— J—BOX. FINAL LOCATION OF THE SWITCHES SHALL AS SELECTED BY THE INTERIOR DESIGNER. COORDINATE WITH INTERIOR DESIGNER DRAWINGS AND SPECS. EQ PROVIDE FLOOR MOUNTED J —BOX UNDER P.O.S. CASH REGISTER BUILT —IN DESK. WITH 3/4" EMPTY CONDUIT WITH PULL STRINGS TO BE RUN UNDER FLOOR TO THE NEAREST PARTITION AND UP TO CEILING SPACE FOR DATA /COMM. CABLE CONNECTIONS. O PROVIDE FLOOR MOUNTED J —BOX WITH TWO CONV. DUPLEX RECEPTACLE UNDER P.O.S. CASH REGISTER BUILT —IN DESK. TO BE CONNECTED WITH 4 112 THWN IN 1 / 2" C. (1 LINE, 1 NEUTRAL, 1 GROUND AND 1 I.G. WIRES) TO A NEW 1P -20 AMPS CIRCUIT BREAKER TO BE PROVIDED AT EXISTING SPACE AT THE EXISTING ELECTRICAL PANEL. © FINAL LOCATION OF THE TWO FLOOR MOUNTED J —BOXES SHALL BE COORDINATED WITH THE INTERIOR DESIGNER PRIOR TO ROUGH —IN. LIGHTING CEILING PLAN NOTES �A PROVIDE NEW LED EXIT SIGN WITH BATTERY PACK TO BE CONNECTED AHEAD OF- SWITCH, PHILIPSAIGHTOLIER EX2— OUTLOOK �B} PROVIDE RECESSED EMERGENCY LIGHT WITH BATTERY PACK TO BE CONNECTED AHEAD OF SWITCH. PHILIPSAIGHTOLIER SOLUTION 2 SERIES. QC PROVIDE NEW FLUORESCENT COVE LIGHTS. SEE MOUNTING DETAIL ON INTERIOR DESIGNER DRAWINGS. LIGHTOLIER T5 STAGGERED STRIP SERIES. QD PROVIDE J -BOX FOR NEW FLUORESCENT COVE LIGHT. FINAL LOCATION TO BE COORDINATE WITH INTERIOR DESIGNER FOR AN ACCESIBLE LOCATION LIGHTOLIER T5 STAGGERED STRIP SERTIES. PROVIDE 2 #12 THWN CU IN 1/2" C. TO EXISTING 1P -20 AMPS SPARE CIRCUIT BREAKER AT EXISTING PANEL. Q PROVIDE 2 #12 THWN CU IN 1/2" C. TO NEW LIGHTING SWITCH 0 PROVIDE 2 #12 THWN CU IN 1/2" C. TO NEW LIGHTING SWITCH "b" (H PROVIDE 2 #12 THWN CU IN 1/2" C. TO NEW LIGHTING SWITCH "c" IQ PROVIDE 2 #12 THWN CU IN 1/2" C. TO NEW LIGHTING SWITCH "d" Q PROVIDE 2 #12 THWN CU IN 1/2" C. TO NEW LIGHTING SWITCH "e" Q NEW LIGHTING SWITCH BANK.VERIFY FINAL LOCATION AND SWITCH TYPE AND COLOR WITH INTERIOR DESIGNER PRIOR TO ROUGH -IN. QM PROVIDE NEW RECESSED DOWN LIGHT WITH LED LAMPS. TO BE SELECTED BY INTERIOR DESIGNER (120V, LIGHTOLIER CALCULATE) Q PROVIDE NEW DECORATIVE LIGHT FIXTURE TO BE SELECTED BY INTERIOR DESIGNER. a� P ac APP VED _ _ _ ---- - -___ project:, revi si ons : D aY: South Miami Advanced I Center for Surgery I QI w oar : DR. ALAN SERURE I SUITE 200 z PLACE 11/23112 UPSTAIRS STUDIO ' I SOUTH MdAMI, FL 33143 I ®2'12-------- et d architecture - - - - -� � - -! Mari 41 Midway w Martinez, Stew AIA 3941 Midway Street Ln AL �. = /� Miami, Florida 33133 A— A Tel 305 447 -1907 Fax 305 447 -1906 sO Qg Q re-mail: infoC-upstairsstudioarchitect 7com rt 0 a p FLORIDA LICENSE: AA 0003146 a� P ac