13-80-003ELECTRICAL NOTES 1. ALL WIRING TO RUN EXPOSED, CONCEALED IN MASONRY WALLS OR CONCRETE 14. ELECTRICAL CONTRACTOR SHALL VERIFY ALL EQUIPMENT NOT FURNISHED SLABS, BENEATH SLABS OF GRADE OR RUN UNDERGROUND SHALL BE IN RIGID AS WILT 11 -21 -13 UNDER THIS SECTION BEFORE ROUGHING -IN. GALVANIZED STEEL CONDUIT. OR PVC SCHEDULE 80 IF EXPOSED, OR SCHEDULE Lc! H 40 IN ALL OTHER SITUATIONS, GALVANIZED STEEL CONDUIT. ELECTRICAL METALLIC 15. SEE EQUIPMENT LAYOUT PLANS FOR LOCATION OF BUILDING EQUIPMENT BEFORE TUBING MAY BE CONCEALED IN INTERIOR HOLLOW WALLS AND ABOVE SUSPENDED ROUGHING -IN. 2 ALL WIRES SHALL BE COPPER UNLESS SPECIFICALLY OTHERWISE INDICATED ON 16. ELECTRICAL CONTRACTOR SHALL VERIFY LOCATION OF ALL EQUIPMENT'S THE DRAWINGS. ALL INSULATION SHALL BE TYPE "THW ". OR "THHN/THWN ". REQUIRING ELECTRICAL CONNECTION BEFORE ROUGHING -IN. CEILINGS. 17. CONDUIT RUNS ARE SHOWN SCHEMATICALLY. BUILDING CONDITIONS WILL 3 BOXES SHALL BE PROVIDED FOR ALL OUTLETS. IN GENERAL THESE BOXES SHALL DETERMINE THE ACTUAL CONDUIT RUN. BE STAMPED OR PRESSED SHEET METAL. BOXES IN HAZARDOUS AREAS SHALL BE APPROVED FOR THE CONDITIONS INDICATED. 18. ELECTRICAL CONTRACTOR SHALL VERIFY WITH MANUFACTURER THE LOCATION OF CONNECTION BOX OF EACH EQUIPMENT BEFORE ROUGHING -IN. 4 ALL CONDUITS SHALL BE SECURELY FASTENED TO THE BUILDING WITH PIPE STRAPS OR OTHER APPROVED PIPE SUPPORTS. 19, WHERE WIRE SIZES ARE INDICATED ON THE PLANS FOR ANY INDIVIDUAL CIRCUITS. THE INDICATED WIRE SIZE SHALL APPLY TO THE COMPLETE 5 MANUFACTURER'S NAMES AND CATALOG NUMBERS ARE USED TO DEFINE THE CIRCUIT UNLESS OTHERWISE INDICATED. TYPE AND QUALITY OF EQUIPMENT AND MATERIAL. EQUAL ITEMS OF OTHER MANUFACTURERS ARE ACCEPTABLE WITH THE APPROVAL OF THE ENGINEER. 20. ALL MOTORS STARTERS FOR FANS, PUMPS, BOILERS, AIR CONDITIONING, ETC.; SHALL BE EQUIPPED WITH OVERLOAD PROTECTION IN EACH PHASE LEG. 6 ALL WORK SHALL BE DONE IN FULL ACCORDANCE WITH THE NATIONAL STARTERS FOR MOTORS RATED AT 50 HP. OR LESS AT 208 v. MAY BE ACROSS THE ELECTRICAL CODE. ALL APPLICABLE STATE AND LOCAL CODES, AND THE LOCAL LINE TYPE, WHERE APPLICABLE STARTERS FOR LARGER MOTORS SHALL BE UTILITY COMPANY REQUIREMENTS. COMPLY W/F.B.C. 2010 REDUCED VOLTAGE TYPE PART WINDING, PRIMARY RESISTOR, ETC.) 7 . ALL WORK SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER. 21, ALL EQUIPMENT FURNISHED WITH CORD, THE CORD SHALL BE SHORTENED AND 8 AS SOON AS PRACTICABLE, AND WITHIN THIRTY DAYS AFTER THE AWARD OF THE INSTALLED WITH CORRECT OUTLET PLUG, JACKS, ETC., AS REQUIRED FOR CONTRACT, AND BEFORE ANY MATERIALS OR EQUIPMENT ARE RELEASED FOR COMPLETE INSTALLATION OF EQUIPMENT. ALSO WHEN APPLICABLE RECEPTACLES SHIPMENT, THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER FOR APPROVAL A SHALL BE FURNISHED TO MATCH THE ELECTRICAL EQUIPMENT SERVED BY. COMPLETE LIST OF MATERIALS AND EQUIPMENT THAT HE PROPOSES TO FURNISH AND INSTALL, GIVING MANUFACTURER'S NAMES. TRADE NAMES, CATALOG 22• ALL ELECTRICAL SERVICE EQUIPMENT SHALL BE READILY ACCESSIBLE NUMBERS, ETC. SEVEN COPIES SHALL BE FURNISHED. AND SHALL HAVE CLEAN AND DRY LOCATION AND BE PROTECTED FROM PHYSICAL DAMAGE. ALSO, CLEAN WORKING SPACE SHALL BE PROVIDED AROUND EQUIPMENT 9 WHERE A CONDUIT PASSES THROUGH A BUILDING EXPANSION JOINT OR A AS PER NEC. 110 -26 STRAIGHT RUN EXCEEDS 200 FT. AND APPROVED EXPANSION FITTING WITH BONDING JUMPER SHALL BE INSTALLED. 23. JUNCTION AND PULLBOXES SHALL BE SECURELY MOUNTED TO THE BUILDING STRUC. REPRESENTATIVE SPARE FUSES IN THE AMOUNT OF 10 90 OF EACH SIZE USED ON 10. WHERE FUSIBLE EQUIPMENT IS SPECIFIED, DELIVER TO THE OWNERS BOXES. BRACKETS, RODS, HANGERS, BOLTS OF OTHER SUITABLE SUPPORTING METHOD THE JOB WITH A MINIMUM OF 3 FUSES OF EACH SIZE. MAY BE USED. 11. THE CONTRACTOR SHALL VISIT THE SITE BEFORE SUBMITTING HIS BID IN ORDER 24. JUNCTION AND PULLBOXES SHALL BE GALVANIZED CODE -GAUGE SHEET STEEL, THAT HE MAY BECOME AWARE OF EXISTING CONDITIONS, NO ALLOWANCES WILL WITH SCREWED ON COVER, NEMA 1, OF SIZES AND SHAPE TO ACCOMMODATE BE MADE FOR ANY EXISTING CONDITION OF WHICH THIS CONTRACTOR WAS NOT WIRING WITHOUT CROWDING AND TO SUIT LOCATION. 12. CIRCUIT NUMBERS SHOWN ARE FOR IDENTIFICATION ONLY. IT SHALL BE THE 25. ALL JUNCTION AND PULLBOXES SHALL BE ACCESSIBLE ALL THE TIME AFTERICAL CONTRACTOR'S RESPONSIBILITY TO COMPLETE PHASE PANEL BOARD 26. ALL RACEWAYS ROUTED, INSULATED CONDUCTORS SYSTEM SHALL BE COLOR CODED AS PER NEC. STANDARDS . 13. SEE EQUIPMENT LAYOUT PLANS FOR EXACT LOCATION OF ALL MOTORS AND FR&Q�84) NT BEFORE ROUGHING -IN. 27. PROVIDE J.B. AS REQUIRED BY FIELD CONDITIONS, EVEN IF NOT SHOWN 2 SETS OF 310 THWN (CU) IN 2 70 COND. EACH 2 SETS OF 310 THWN (CU) IN 2 70 COND. EACH 200 AMPS 1201240 MCB IN NEMA 3R ENCLOSURE FOR PANEL "B" 3 #310 THWN (CU) +1#4 THWN (CU)(G) IN 2" COND. 3 411 THWN (CU) —+1#6 THWN (CU)(G) r IN 1 -112" COND. 1 SUB PANEL " 125A. L_ J 7SCOPE OF WORK O PANEL PANEL "A" "B" 225 A. 225 A. GUTTER (E) 200 AMPS 1201240 MCB IN NEMA 3R ENCLOSURE FOR PANEL 'A" 1j1/0 THWN (G) TO -- WCP - - - -- - - - - -- 1 # 2 THWN (Cu) BARE _ 518 "0 GROUNDING ROD 10' DEEP EXISTING ELECTRICAL RISER MITI IN NtMA JK ENCLOSURE FOR PANEL "A" ELECTRICAL PLAN SCALE: 1/4" = V-011 ELECTRICAL SYMBOL LEGEND ^ ^ I Q JUNCTION BOX j % JB W /SPECIAL SUPPORT FAN & LIGHT Q HIGH HATS LIGHTING + MINI HIGH HATS LIGHTING - - Q VAPOR PROOF ® CEILING MOUNTED FIXTURE WALL MOUNTED FIXTURE Q MOTOR FOR CHANDELIER PICTURE WALL MOUNTED FIXTURE FLUORESCENT FIXTURE QUADRUPLEX RECEPTACLE c GFI RECEPTACLE GFI RECEPTACLE 8" ABOVE COUNTER 8— SINGLE RECEPTACLE I- ® 2 POLE OUTLET RECEPTACLE FLOOR RECEPTACLE SWITCHABLE DUPLEX RECEPTACLE GARBAGE DISPOSAL Cg SPOT LIGHT o ELECTRIC PANEL Lj EXHAUST FAN WP WEATHER PROOF SWITCH $s 3WAY SWITCH $0 LOW VOLTAGE SYSTEM SWITCH (DIMMER) TELEPHONE © TELEVISION CABLE OUTLET SD SMOKE DETECTOR ® GARAGE DOOR OPENER CONTROLLER ® INTERCOM ®COMBINATION SMOKE CARBON/ MONOXIDE DETECTOR LIGHTING FIXTURES FOR KITCHEN CABINETS o[]e DOOR BELL SCOPE OF WORK: REMODELING OF BATHROOMS WITH PARTIAL ALTERATION OF SEATING AREA (NON SHADED). THE RELOCATED LIGHT FIXTURES AND RECEPTACLES IN BATHROOM AREA WILL BE FED FROM THE SAME CIRCUIT AS IT IS IN THE EXISTING CONDITIONS (RELOCATED). NEW EXIT /EMERGENCY LIGHT IS PROPOSED ABOVE THE NEW ENTRANCE DOOR, DUE TO NOW ELECTRICAL FIXTURES 1S ADDED. NEW LOAD CALCULATIONS FOR PANEL "C" IS NOT REQUIRED. 0,. 3 •- °� . P.E. No 53288 • . Jose Antonio Mendez. 1 w w r. r Id f:% Professional Engineer .r� MaM(DM12 1385 Coral Way Suite #203 Mlaml, FL 33145 �0 ®BBQB ®90® limp. PH: 305 8549824 FAX(305)856-1797 jose0118(daol.o= CA 00008324 REVISIONS 5Y n REVISION L ±_1 11 -01 -13 AS WILT 11 -21 -13 N 0 m0it` Lc! H = 0 M rn M co co Q LO o O v U U W < g M O Z W w a L w z � cl O Z Q_ • t`'!''i .y� �i • r' .dv Q�cq 12kL� LU LL ll__ cn = U cq< O T DRAM EAC. Jr. Cl IECKED EAC DATE A LY '12 SCALE SHORN JOB No. 2012 -015 SHEET E-1 F W� 4 rP • N 0 m0it` Lc! H = N o . Y' O w uj .4-14 o to , �ydp O Z W w a L w z � cl O Z Q_ • t`'!''i .y� �i • r' .dv Q�cq 12kL� LU LL ll__ cn = U cq< O T DRAM EAC. Jr. Cl IECKED EAC DATE A LY '12 SCALE SHORN JOB No. 2012 -015 SHEET E-1 F W� 4 rP