13-80-015
EL-.C- TRICAL MOTES EAL. Jr. CHECKEDI 1. ALL WIRING TO RUN EXPOSED, CONCEALED IN MASONRY WALLS OR CONCRETE 14. ELECTRICAL CONTRACTOR SHALL VERIFY ALL EQUIPMENT NOT FURNISHED SLABS, BENEATH SLABS OF GRADE OR RUN UNDERGROUND SHALL BE IN RIGID UNDER THIS SECTION BEFORE ROUGHING —IN. GALVANIZED STEEL CONDUIT. OR PVC SCHEDULE 80 IF EXPOSED, OR SCHEDULE 15. EQUIPMENT LAYOUT PLANS FOR LOCATION OF BUILDING EQUIPMENT BEFORE 40 IN ALL OTHER SITUATIONS, GALVANIZED STEEL CONDUIT, ELECTRICAL METALLIC ROUGHING—IN. TUBING MAY BE CONCEALED IN INTERIOR HOLLOW WALLS AND ABOVE SUSPENDED 2012 -025 2 ALL WIRES SHALL BE COPPER UNLESS SPECIFICALLY OTHERWISE INDICATED ON 16_ ELECTRICAL CONTRACTOR SHALL VERIFY LOCATION OF ALL EQUIPMENTS THE DRAWINGS. ALL INSULATION SHALL BE TYPE 'THW" OR 'THHN/THWN'. REQUIRING ELECTRICAL CONNECTION BEFORE ROUGHING—IN. CEILINGS. 17. CONDUIT RUNS ARE SHOWN SCHEMATICALLY. BUILDING CONDITIONS WILL 3 BOXES SHALL BE PROVIDED FOR ALL OUTLETS. IN GENERAL THESE BOXES SHALL DETERMINE THE ACTUAL CONDUIT RUN. BE STAMPED OR PRESSED SHEET METAL, BOXES IN HAZARDOUS AREAS SHALL BE 1 d. ELECTRICAL CONTRACTOR SHALL VERIFY WITH MANUFACTURER THE LOCATION APPROVED FOR THE CONDITIONS INDICATED. OF CONNECTION BOX OF EACH EQUIPMENT BEFORE ROUGHING -IN. 4 ALL CONDUITS SHALL BE SECURELY FASTENED TO THE BUILDING WITH PIPE 19. WHERE WIRE SIZES ARE INDICATED ON THE PLANS FOR ANY INDIVIDUAL STRAPS OR OTHER APPROVED PIPE SUPPORTS. CIRCUITS. THE INDICATED WIRE SIZE SHALL APPLY TO THE COMPLETE 5 MANUFACTURER'S NAMES AND CATALOG NUMBERS ARE USED TO DEFINE THE CIRCUIT UNLESS OTHERWISE INDICATED. TYPE AND QUALITY OF EQUIPMENT AND MATERIAL. EQUAL ITEMS OF OTHER MANUFACTURERS ARE ACCEPTABLE WITH THE APPROVAL OF THE ENGINEER. 20. ALL MOTORS STARTERS FOR FANS, PUMPS, BOILERS, AIR CONDITIONING, ETC.; SHALL BE EQUIPPED WITH OVERLOAD PROTECTION IN EACH PHASE LEG. 6 ALL WORK SHALL BE DONE IN FULL ACCORDANCE WITH THE NATIONAL STARTERS FOR MOTORS RATED AT 50 HP. OR LESS AT 208 v. MAY BE ACROSS THE ELECTRICAL CODE. ALL APPLICABLE STATE AND LOCAL CODES, AND THE LOCAL LINE TYPE, WHERE APPLICABLE STARTERS FOR LARGER MOTORS SHALL BE UTILITY COMPANY REQUIREMENTS. COMPLY W/F.B.C, 2010 REDUCED VOLTAGE TYPE PART WINDING, PRIMARY RESISTOR, ETC.) 7 ALL WORK SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER. 21, ALL EQUIPMENT FURNISHED WITH CORD, THE CORD SHALL BE SHORTENED AND d AS SOON AS PRACTICABLE, AND WITHIN THIRTY DAYS AFTER THE AWARD OF THE INSTALLED WITH CORRECT OUTLET PLUG, JACKS, ETC., AS REQUIRED FOR COMPLETE INSTALLATION OF EQUIPMENT, ALSO WHEN APPLICABLE RECEPTACLES CONTRACT, AND BEFORE ANY MATERIALS OR EQUIPMENT ARE RELEASED FOR UIPMEN SHALL FURNISHED TO MATCH THE ELECTRICAL EQUIPMEN T SERVED BY SHIPMENT, THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER FOR APPROVAL A .BE COMPLETE LIST OF MATERIALS AND EQUIPMENT THAT HE PROPOSES TO FURNISH 22 ALL ELECTRICAL SERVICE EQUIPMENT SHALL BE READILY ACCESSIBLE AND INSTALL, GIVING MANUFACTURER'S NAMES. TRADE NAMES, CATALOG AND SHALL HAVE CLEAN AND DRY LOCATION AND BE PROTECTED FROM PHYSICAL NUMBERS, ETC. SEVEN COPIES SHALL BE FURNISHED. DAMAGE. ALSO, CLEAN WORKING SPACE SHALL BE PROVIDED AROUND EQUIPMENT 9 WHERE A CONDUIT PASSES THROUGH A BUILDING EXPANSION JOINT OR A AS PER NEC. 110 -26 STRAIGHT RUN EXCEEDS 200 FT. AND APPROVED EXPANSION FITTING WITH INSTALLED. 23, JUNCTION AND PULLBOXES SHALL BE SECURELY MOUNTED TO THE BUILDING STRUC. BONDING JUMPER SHALL BE REPRESENTATIVE SPARE FUSES IN THE AMOUNT OF 10 X OF EACH SIZE USED ON BOXES- BRACKETS, RODS, HANGERS, BOLTS OF OTHER SUITABLE SUPPORTING METHOD 10. WHERE FUSIBLE EQUIPMENT !S SPECIFIED, TO THE OWNERS MAY BE USED, THE JOB WITH A MINIMUM OF 3 FUSES OF EACH SIZE. 11. THE CONTRACTOR SHALL VISIT THE SITE BEFORE SUBMITTING HIS BID IN ORDER 24. JUNCTION AND PULLBOXES SHALL BE GALVANIZED CODE —GAUGE SHEET STEEL, NEMA 1, OF SIZES AND SHAPE TO ACCOMMODATE THAT HE MAY BECOME AWARE OF EXISTING CONDITIONS, NO ALLOWANCES WILL WITH SCREWED ON COVER, WIRING WITHOUT CROWDING AND TO SUIT LOCATION. BE MADE FOR ANY EXISTING CONDITION OF WHICH THIS CONTRACTOR WAS NOT 25. ALL JUNCTION AND PULLBOXES SHALL BE ACCESSIBLE ALL THE TIME. 12. CIRCUIT NUMBERS .SHOWN ARE FOR IDENTIFICATION ONLY. IT SHALL BE THE E,t�EA T ?ICAL CONTRACTOR'S RESPONSIBILITY TO COMPLETE PHASE PANEL BOARD 26. ALL RACEWAYS ROUTED, INSULATED CONDUCTORS SYSTEM SHALL BE COLOR CODED AS PER NEC. STANDARDS . 13, SEE EQUIPMENT LAYOUT PLANS FOR EXACT LOCATION OF ALL MOTORS AND 27. PROVIDE J.B. AS REQUIRED BY FIELD CONDITIONS, EVEN IF NOT SHOWN pT,6N(fQV8)1 eT BEFORE ROUGHING -IN, 200 AMPS 1201240 MCB 2 SETS OF IN NEMA 3R ENCLOSURE 3#310 THWN (CU) 310 THWN (CU) FOR PANEL "B" +1#4 THWN (CU)(G) IN 2 "0 COND, EACH IN 2" COND. THWN TH N((CU)(G) IN 1--112 COND. SUB PANEL PANEL PAC EL ..A „ „B" C. 225 A. 225 A. 125 A. i 2 SETS OF �– =72i 310 ,THWN (CU) IN 2-0 -COND. EACH 200 AMPS SCOPE OF GUTTER (E) 1201240 MCB WORK IN NEMA 3R ENCLOSURE FOR PANEL A" 1 # 1 /0 THWN (G) — — A TO WCP 1 # 2 THWN (Cu) BARE 51870 GROUNDING ROD 10' DEEP -EXISTING ELECTRICAL RISE N Tom. MUD IN Vii J r n I\ ENCLOSURE FOR PANEL_ "A" ELECTRICAL PLAN 5GALE: I /4" = I'-Oil i S•. \W"i c t C. � �, F/ sm q1 I .;a�' n 4', vow • " U • G • U f Y • G r•Ffr V • • Y • W G • � r ••r ••• u " G sY•• c, e • • u s v VWG i. • • y • • " • V V ` V W U U u U u ► G V V i� V ELECTRICAL SYMBOL LEGEND''• W "G JUNCTION BOX .... f . • • . r. • r • AJB W /SPECIAL SUPPORT 6A ;k, LIGNI' U Q HIGH HATS LIGHTING ° G Y G f V W N f• . "• MINI HIGH HATS LIGHTING vO VAPOR PROOF CEILING MOUNTED FIXTURE WALL MOUNTED FIXTURE MOTOR FOR CHANDELIER PICTURE WALL MOUNTED FIXTURE FLUORESCENT FIXTURE QUADRUPLEX RECEPTACLE GFI RECEPTACLE GF1 RECEPTACLE 8" ABOVE COUNTER SINGLE RECEPTACLE 2 POLE OUTLET RECEPTACLE FLOOR RECEPTACLE SWITCHABLE DUPLEX RECEPTACLE GARBAGE DISPOSAL c� SPOT LIGHT ELECTRIC PANEL Lf j EXHAUST FAN Wp WEATHER PROOF $ SWITCH $3 3WAY SWITCH $r LOW VOLTAGE SYSTEM SWITCH (DIMMER) -4 TELEPHONE TELEVISION CABLE OUTLET s� SMOKE DETECTOR Q GARAGE DOOR OPENER CONTROLLER @ INTERCOM COMBINATION SMOKE CARBON/ MONOXIDE DETECTOR LIGHTING FIXTURES FOR KITCHEN CABINETS oB DOOR BELL 11 G V GVV • •suv � . r r • W •vWY SCOPE OF WORK: REMODELING OF BATHROOMS WITH PARTIAL ALTERATION OF SEATING ARFA (NON SHADED). THE RELOCATED LIGHT FIXTURES AND RECEPTACLES IN BATHROOM AREA WILL BE FED FROM THE SAME CIRCUIT AS IT IS IN THE EXISTING CONDITIONS (RELOCATED). NEW EXIT /EMERGENCY LIGHT IS PROPOSED ABOVE THE NEW ENTRANCE DOOR, DUE TO NOW ELECTRICAL FIXTURES IS ADDED. NEW LOAD CALCULATIONS FOR PANEL "C" IS NOT REQUIRED_ ,1 � � r • K M '1. 'NFMX rIpum"Ar"Ei " paom�am� aaa�ltala6aa P.E. No 53288 Jose Antonio Mendez. Professional Engineer go M M a a pM@911Q0am ©a 13$5 Coral Way Suite *203 Miami. FL 33145 Immomalmoma NW. FK(305)854 -9324 FAX(305)$56-1797 CA 00002324 jose011$9201-com �J C) U INN 0 U Q x W < M 'O n I Li.J 1= U) 0 0 U J p ¢n a) C3 © ° ) 2 00 N � �Q rn 0 CD N I LL_ W w tv Ul Q 0 w CP a-) __j ut Lj_ OL wwea E)RAUN EAL. Jr. CHECKEDI E.A.c DATE JULY '12 SCALE SHOWN JOB No. 2012 -025 SHEET