13-80-012p - -- .. -. - - -0 Cam- MAX 20 FT Wm 4& ONE HOUR FIRE RATED WALL NON -RATED SOUND PARTITION CPET COMMON PATH OF EGRESS TRAVEL (MAX 20 FT)- UNSPRNKLED TRAVEL DISTANCE TO REACH EXIT (MAX 200 FT)- UNSPRMKLED DEAD END LIMIT (MAX 20 FT) UNSPRINKLED EXISTING BUILDING AREA NEW PARTITION 4' WALLS EXIT SIGN EMEWGENCY LIGHT W/ BATTERY BACKUP LIFE SAFETY ANALYSIS: CONSTtRUCTION TYPE EXISTING TO REMAIN (TYPE V-13) FBC. 2010 -TABLE 601 TOTAL AREA ALLOWED EXISTING ONE STORYA,321 SOFT. M.C. 2010 -TABLE 503 DINING AREA 10161 (INTERIOR BUILD OUT ONLY) NFPA 101(2012) -TABLE 13.12 EXISTING ONE STORY/215 SQFC. F.B.C. 2010 -CABLE 1005.1 BATHROOM AREAS (INTERIOR BUILD OUT ONLY) NEW LIFE SAFETY PLAN DISTANCE REQUIREMENTS: UNSPRINKLERED TRAVEL DISTANCE LIMIT 200' -0' MAX ALLOWED NFPA 101(2012) -TABLE Zb COMMON PATH LIMIT 20' -0' MAX ALLOWED F.B.G. 2010 -TA13LE 10143 DEAD END LIMIT 20' -0' MAX ALLOWED 10161 CY LOAD FACTORS: WHERE ACCESS TO EXITS IN PROVIDED BY CORRIDORS, SUCH CORRIDORS SHALL BE NFPA 101(2012�383b.1 NFPA 101(2012) -TABLE 13.12 OCCUPANCY -GROUP A I PER 15 SQFT. (NET) F.B:C_ 2010 -TA5LE 1004JJ CUPANT LOAD AT MAX. USE 88 OCCUPANTS FT7oTAL NFPA 101(2012) -TABLE 13.12 STING PROVIDED (VIA 2 REMOTE EXITS) 330 OCCUPANTS F.B.C. 2010 -CABLE 1005.1 EGRESS CAPACITY (DOOR) 36' SIMPLE DOOR (33' CL. W) 33/02 = 165 OCCUPANTS EXISTING EXIT SIGN EXISTING EMEWoENCY LIGHT W/ BATTERY BACKUP wrrw ••• ♦ r •r••• 00% r W •a WW W ♦ u r r Y J w r V L w V 6 r • • w ss • • r r W U w u Y W it r W• u • • u uui, r r LIFE SAFETY GONSTRUCTION NOTES = r ♦ a ♦ a u • • a ♦•• w ru L- CONTRACTOR TO PROVIDE FIRE EXTINGUISHERS DURING CONSTRUCTION IN CONPLIANCE WITH NFPA 1141 r••• ua•a• rNa 2: ALL FLAMMABLE OR CONBUSTIBLE LIQUIDS TO BE STORED DURING CONSTRUCTION TO Ct"PL Y WITH NF°A -101 (LATEST EDITION) u a i a ♦ • w i• Y • was i 3.- CONTRACTOR TO PROVIDE FIRE 4 SMOKE SAFING AND CAULKING AS REQUIRED FOR ALL PROPOSED PENATRATIONS AT EXISTING AND NEW FIRE RATED 4 SMOKE PARTITIONS/WALLS. 4.- SEE FIRE PROTECTION, ELECTRICAL 4 PLUMBING DWG's FOR DETAILS. ADDITIONAL NOTES: 1- CONTRACTOR TO PROVIDE SIGNAGE AT ALL RATED PARTITIONS, ABOVE ANY DECORATIVE CEILING AND IN CONCEALED SPACES. PROVIDE SIGNAGE . SPACE SIGNAGE EVERY 25' -0' MAX. IN RED LETTERS W/W HIGH CHARACTERS SO ASTO READ 'FIRE 4 SMOKE BARRIER - PROTECT ALL OPENINGS'. ALL SIGNAGE INSTALLATION SHALL COMPLY W/ FBC 104214, AND NWA -1011 4 14 2: ALL GRAZED PANELS, INTERIOR WINDOWS, AND SIDELITES W/BOTOM EDGE ELEVATION AT LESS THAN IV ABOVE FLOOR FINISH SHALL RECEIVE CATEGORY -II SAFETY GLAZING:, EXCEP WHERE 45 MIN WIRED SAFETY GLAZING IS REQUIRED. 3.- PROVIDE ONE ABC FIRE EXTINGUISHER AT V1515LE SPACE. 4.- ALL INTERIOR FINISHES TO BE TYPE 'C' FLAME SPREADS. • U G c$ •W• rrs i•su . CORRIDOR SEPARATION NOTE (NFPA 101 - 38310.1) WHERE ACCESS TO EXITS IN PROVIDED BY CORRIDORS, SUCH CORRIDORS SHALL BE NFPA 101(2012�383b.1 SEPARATED FROM USE AREAS BY WALLS (FIRE BARRIERS) IN ACCORDANCE WITH SECTION 83 HAVING A MINIMUM 1 -HOUR FIRE RESISTANCE RATING, UNLESS ONE OF THE FOLLOWING CONDITIONS EXISTS. 1) WI -ERE EXITS ARE AVAILABLE FROM AN OPEN FLOOR AREA. 2) WITHIN A SPACE OCCUPIED BY A SINGLE TENANT. 3) WITHIN A BUILDINGS PROTECTED THROUGHOUT BY AN APPROVED SUPERVISED NEW LIFE SAFETY PLAN AUTOMATIC TIC, SYSTEM N ACCORDANCE WITH 5.1.1.1 (1) A-1*02---1 �r ,� ;� . � � � � •.� a rt �� x4 I MOWN REVISIONS BY AS PER COUNTY COMMENT 4 -29 -201 Lo b: q o r7 � o 90 an , Li o -I X Lil w U) _ z w W < v F N 0 r, w D w x °o rn V C=l, J cD J J q U Q r� rr Lo C • o 00 z �o..w rn .r rn 0 0 to N IL Z o 04 w w Q o � n � w ..< LU r/ 1 Q ) fu tj DRAWN 71 ElAa Jr. CHECKED DATE JULY '12 SCALE SHOWN JOB No. 2012 -025 SHEET NEW LIFE SAFETY PLAN & NOTES A-1*02---1