14-1064-020I s Q) O d a wh wn Ln NN � 00 ev i • Q a0 l0 O N Cl 15' -0" I 27' -0„ " 0 ' 9- v 7 lJ 4 C x n- SC: 3/16" = 1' -0" 0 GENERAL ELECTRICAL NOTES 1 . ALL ELECTRICAL DISTRIBUTION EQUIPMENT SHALL BE LOCATED ABOVE THE BASE FLOOD CRITERIA. 9. THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE, FEES, PERMITS ASSOCIATION DUES, ANY ELECTRICAL WORK. � ROYALTIES AND TAXES OF WHATEVER NATURE SHALL APPLY TO THIS WORK. CONTRACTOR SHALL 2. INSTALL AS REQUIRED TO MAINTAIN A MAXIMUM VOLTAGE DROP FOR FEEDERS OF 2 % AND 3% FOR ELECTRICAL POWER AS REQUIRED TO COMPLETE THE JOB. ALSO PAY ALL INSPECTION FEES AS MAY BE REQUIRED BY LAW OR ORDINANCE AND SHALL KEEP CIRCUIT NUMBERS ARE DIAGRAMMATIC. EXACT NUMBERS SHALL BRANCH CIRCUITS AS PER CHAPTER 13 OF THE FLORIDA BUILDING CODE. (NO 0 THE OWNER HARMLESS FROM ANY DAMAGE AND EXPENSE ARISING FROM ANY VIOLATION OF THE THE ELECTRICAL CONTRACTOR. 29. LAWS, RULES OR ORDINANCES. 3. ALL WORK SHALL CONFORM WITH ALL LOCAL, STATE, FEDERAL ORDINANCES AND BUILDING CODES _ cd 0 GOVERNING THE INSTALLATION OF THE ELECTRICAL SYSTEM. IF WORK AS LAID OUT, INDICATED OR 10. THE CONTRACTOR SHALL SECURE ALL NECESSARY LICENSES AND INSURANCE. o SPECIFIED IS CONTRARY TO OR CONFLICTS WITH LOCAL ORDINANCES, BUILDING CODES AND Ld a W 0 REGULATIONS, THE CONTRACTOR SHALL REPORT IN WRITING TO THE ARCHITECT /ENGINEER BEFORE 11. ALL WIRE TO BE THHN OR THWN, COPPER, IN RACEWAY, UNLESS OTHERWISE SPECIFIED ON DRAWINGS. 1 SUBMITTING A BID. THE ARCHITECT /ENGINEER WILL THEN ISSUE INSTRUCTIONS AS HOW TO PROCEED. 12. PROVIDE MEANS "FURNISH AND INSTALL ". 4. THE DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC, NOT NECESSARILY SHOWING IN DETAIL OR ) i TO SCALE ALL OF THE MINOR ITEMS. UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE STRUCTURAL, 13. COORDINATE WORK WITH WORK OF OTHER TRADES TO AVOID ALL CONFLICTS. ARCHITECTURAL AND SITE CONDITIONS SHALL GOVERN THE EXACT LOCATIONS. CONTRACTOR SHALL i FOLLOW DRAWINGS IN LAYING OUT WORK, CHECK DRAWINGS OF ALL TRADES TO VERIFY SPACES IN 14. DO A COMPLETE JOB, EVERYTHING CONNECTED, READY FOR USE. WHICH WORK WILL BE INSTALLED AND MAINTAIN MAXIMUM HEAD ROOM, OR SPACE CONDITIONS AT ALL POINTS. WHERE HEAD ROOM, OR SPACE CONDITIONS APPEAR INADEQUATE, ARCHITECT /ENGINEER 15. PROVIDE LIGHT FIXTURES AS PER OWNER SELECTION OR SCHEDULE. SHALL BE NOTIFIED BEFORE PROCEEDING WITH INSTALLATION. THE CONTRACTOR SHALL, WITHOUT EXTRA CHARGE, MAKE FIELDD MODIFICATION IN LAYOUT AS NEEDED TO PREVENT CONFLICT WITH 16. PROVIDE ALL WIRING DEVICES. WIRING DEVICES SHALL BE SUITABLE FOR WORK OF VARIOUS TRADES OR FOR PROPER EXECUTION OF THE WORK. 1 THE ENVIRONMENT INSTALLED. NO TANDEM BREAKERS OR WITH TIE HANDLES. 5. EXAMINE ALL DRAWINGS CAREFULLY PRIOR TO SUBMITTING A BID. CONTRACTOR WILL BE REQUIRED 17. IDENTIFY CLEARLY ON A TYPE WRITTEN FORM ALL CIRCUITS AND EQUIPMENT TO CORRESPOND WITH TO FURNISH, INSTALL AND /OR CONNECT WITH APPROPRIATE SERVICES ALL ELECTRICAL DEVICES THE PLANS AND PANELS SCHEDULE AND ATTACH INSIDE THE PERTAINING PANEL. SHOWN ON THE ELECTRICAL DRAWINGS. IF DISCREPANCIES, CONFLICTS, INTERFERENCES OR OMISSIONS OCCUR BETWEEN DRAWINGS, NOTIFY IN WRITING THE ARCHITECT /ENGINEER IN AMPLE 18. PROVIDE IDENTIFICATION LABELS FOR POWER PEDESTALS AND PANELS WHICH ARE SUITABLE FOR TIME TO PERMIT REVISIONS BEFORE THE BIDS ARE SUBMITTED, THE ENVIRONMENT INSTALLED. 6. VERIFY SERVICE CHARACTERISTICS, LOCATION AND CONNECTION WITH TELEPHONES AND ELECTRIC 19. RACEWAYS; ALL UNDERGROUND RACEWAYS TO BE PVC, INSIDE CONCRETE SLAB EMT WITH APPROVED UTILITY COMPANIES. PERFORM ALL WORK RELATED TO SERVICE IN STRICT ACCORDANCE WITH UTILITY SET SCREW FITTING. FOR FLOOR PENETRATION USE ONLY EMT. CO. STANDARDS AND REQUIREMENTS. 20. SHOP DRAWINGS; THIS CONTRACTOR SHALL FURNISH THE ENGINEER WITH SHOP DRAWINGS OF 7. INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND FIRST CLASS WORKMANLIKE MANNER. THE EQUIPMENT PRIOR TO PURCHASE FOR APPROVAL. OWNER RESERVES THE RIGHT TO DIRECT REMOVAL AND REPLACEMENT OF ITEM WHICH, IN HIS OPINION, DOES NOT PRESENT A NEAT AND WORKMANLIKE APPEARANCE. REMOVAL AND REPLACEMENT 21. TESTING; THE CONTRACTOR SHALL TEST ALL WORK AND EQUIPMENT AS DIRECTED BY THE ARCHITECT IS TO BE DONE IMMEDIATELY WHEN DIRECTED BY THE OWNER IN WRITING, AT THE SOLE EXPENSE OF AND BY AUTHORITIES HAVING JURISDICTION, FURNISHING ALL EQUIPMENT AND NECESSARY PERSONNEL CONTRACTOR. AND ELECTRIC POWER. THE ENTIRE INSTALLATION SHALL BE TESTED FOR SHORTS, GROUNDS AND OPEN CIRCUITS AND ALL DEFECTS SHALL BE DEMONSTRATED TO BE IN PROPER WORKING AND 8. START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS ACCEPTANCE BY HIM OF ALL CLAIMS OPERATING CONDITION TO THE COMPLETE SATISFACTION OF THE ENGINEER. OR QUESTIONS AS TO SUITABILITY OF THE WORK OF OTHER TRADES OR OTHER CONTRACTORS TO RECEIVE HIS WORK. THE CONTRACTOR SHALL REMOVE AND REPLACE, AT HIS EXPENSE, ALL ELECTRICAL 22. GUARANTEES; ALL EQUIPMENT AND MATERIALS SHALL BE NEW AND MANUFACTURER'S LATEST EDITION WORK WHICH MAY HAVE TO BE REMOVED BECAUSE OF INTERFERENCE WITH OTHER TRADES. AND GUARANTEED FOR ONE YEAR AFTER THE DATE OF ACCEPTANCE BY OWNER. 22. GUARANTEES; ALL EQUIPMENT AND MATERIALS SHALL BE NEW AND MANUFACTURER'S LATEST EDITION AND GUARANTEED FOR ONE YEAR AFTER THE DATE OF ACCEPTANCE BY OWNER. 23. ALL MATERIALS SHALL BEAR THE LABEL OF THE UNDERWRITERS LABORATORY FOR THE INTENDED USE OR SHALL BE MATERIALS /DEVICES APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION IN WRITING. 24. AT COMPLETION OF JOB, THE ELECTRICAL CONTRACTOR SHALL GIVE THE OWNER THE FOLLOWING: 1. AS -BUILT SET OF DRAWINGS SHOWING THE EXACT ELECTRICAL INSTALLATION. 2. OPERATING MANUAL AND MAINTENANCE MANUAL AS PER FBC 2010- ENERGY CODE SECTION 505.7.4.2. 25. BEFORE BIDDING THE JOB, THE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH ALL EXITING CONDITIONS. 26. ELECTRICAL CONTRACTOR SHALL GIVE BUILDING MANAGEMENT A 7 DAY NOTICE PRIOR TO STARTING ANY ELECTRICAL WORK. � O 27. THE CONTRACTOR SHALL PROVIDE TEMPORARY ELECTRICAL POWER AS REQUIRED TO COMPLETE THE JOB. 28. CIRCUIT NUMBERS ARE DIAGRAMMATIC. EXACT NUMBERS SHALL BE DETERMINED IN THE FIELD AND (NO 0 REFLECTED ON AS -BUILT DOCUMENTATION BY THE ELECTRICAL CONTRACTOR. 29. THE ELECTRICAL CONTRACTOR SHALL BALANCE THE LOADS FOR ALL PANELS. ELECTRICAL LEGEN C-: g p m m DUPLEX RECEPTACLE OUTLET. (20A. 120V. 1PH.) e- SINGLE RECEPTACLE OUTLET. (? ?F . 120V. ' PH.1- - - - ♦ QUADUPLEX RECEPTACLE OUTLET: -(20A. 120V. _1PH.) DISCONNECT SWITCH, SIDE HA9,?l -F -TYPE-.T- 0 SURFACE MOUNTED LIGHT FIXTURE. 10 $ LIGHT SWITCH. LETTER INDICATES LIGHT FIXTURES CONTROLLED. $o DIMMABLE LIGHT SWITCH ,$ LIGHT SWITCH 3 -WAY T'IPE. EMERGENCY BATTERY POWERED LIGHTS CONNECT AHEAD OF LIGHT SWITCH. } EXIT SIGN 120V. WITH BATTERY BACK UP POWER WALL OR CEILING MOUNT. CONNECT AHEAD OF LIGHT SWITCH. ARROW = DIRECTION OF EXIT. SHADED AREA = FACE OF FIXTURE. EXIT SIGN WITH EMERGENCY LIGHTS. P14 -5 ELECTRICAL PANEL P14, CIRCUIT #5, VERIFY CIRCUITS AT JOB SITE. O A/C THERMOSTAT. VERIFY LOCATION. EXHAUST FAN. O JUNCTION BOX. SIZE AS REQUIRED. WP WEATHER PROOF ENCLOSURE. = ELECTRICAL PANEL. SEE SCHEDULE. O SEE KEYED NOTES FOR DESCRIPTION. 9 DRYER RECEPTACLE OUTLET 208V., 1PH. D. DATA OUTLET. VERIFY WITH TENANT FOR QUANTITY & LOCATIONS. Fill FLOOR MOUNTED DUPLEX RECEPTACLE OUTLET AND DATA OUTLET GFCI GROUND FAULT CIRCUIT INTERRUPTER. EWC ELECTRIC WATER COOLER. EWH ELECTRIC WATER HEATER. IWH INSTANT WATER HEATER. TTB TELEPHONE TERMINAL BOARD. E EXISTING TO REMAIN MECHANICAL SUPPLY DIFFUSER (SEE MECHANICAL DRAWINGS) z MECHANICAL RETURN AIR GRILLE (SEE MECHANICAL DRAWINGS) 2'x4' RECESSED FLUORESCENT (TYPE T8) LIGHT FIXTURE. O2'x2' RECESSED FLUORESCENT (TYPE T8) LIGHT FIXTURE. 0 120 V AC OCCUPANCY SENSOR NOTE: THE LIGHTING DESIGN IS IN COMPLIANCE WITH THE FLORIDA BUILDING CODE - ENERGY CODE SECTION 505. NOTE: FIRE ALARM DRAWINGS UNDER SEPARATE PERMIT. ELECTRICAL SCOPE OF WORK: 1. INSTALL AND PROVIDE BRANCH CIRCUIT FOR NEW ELECTRICAL EQUIPMENT. NEW ELECTRICAL EQUIPEMENT ARE THOSE NOT MARKED WITH AN "E ". EXISTING WIRING MAY BE USED AS INDICATED ON PANEL DIRECTORY. 2. BALANCE PANEL LOADS. 3. VERIFY EXISTING LOADS AND UPDATE PANEL DIRECTORY ACCORDINGLY. 4. PROVIDED NEW TYPE WRITTEN PANEL DIRECTORIES. REVISIONS BY /BLDG. DEPT. COMM. R.A. z � � 09 -23 -2014 W_ o o r? o � O W Ln _O cV o 0 tn (NO 0 o c r ?M M LL _ cd 0 C 0 o = O W o a Ld a W 0 .� nom. Vi 1�•, h4k o o r? o O f ` o _O cV o C4 �l (NO 0 o 4- `I QD W LL N � p o �f a Q Q�m ' r v LLi h4k o 0 C4 �l (NO 0 o ° •u) H LL N � p E a •� a H �- •- O u- ' r v 1 h4k Gj U w CL M DATE: 08/22/14 SCALE: AS SHOWN DWN. BY: CHKD. BY. RRL V.S. DSGN. BY: CHKD. BY: V.S. V S. PROJECT NO: 12 -127 DRAWING: Imo? Sheet 10 of 14 X11 , Gj U w CL M DATE: 08/22/14 SCALE: AS SHOWN DWN. BY: CHKD. BY. RRL V.S. DSGN. BY: CHKD. BY: V.S. V S. PROJECT NO: 12 -127 DRAWING: Imo? Sheet 10 of 14 ' r 1 tt I � ) i . i 1 Gj U w CL M DATE: 08/22/14 SCALE: AS SHOWN DWN. BY: CHKD. BY. RRL V.S. DSGN. BY: CHKD. BY: V.S. V S. PROJECT NO: 12 -127 DRAWING: Imo? Sheet 10 of 14