14-1064-015T
0
r
m
v
N �
cv ul
N
N�
0 I
Ncu
v
o �
l �•
Q
N Q
0
I
in
IN
(K).3
TO PUBLIC
RIGHT OF WAY o
Lo
LIFE SAFETY
LEGEND
S
/CM C,a
EGRESS WIDTH
GENERAL NOTES
S&P
SYMBOLS
PROVIDED
1. OWNER TO PROVIDE EMERGENCY PLAN AT PROJECT
BUSINESS
EXITS
COMPLETION AS PER NFPA 101
28.7.3 AND 28.7.4.
34" EXIT 1 & 2
OCCUPANCY MARK
(0.3' PER OCCUPANT
300 S.F. AREA (S.F.)
100 1 3
ACTUAL OCCUPANT LOAD
TOTAL OCCUPANCY: 85 PERSONS
I
FS.F. PER PERSON REQUIRED
LEGEND
EXIT #1
EXIT DATA
3 & 4
■ ■
1 HR. FIRE RATED WALL
34"
1
AS PERETABLEE 10051)
OPENING WIDTH
170 PEOPLE
ALLOWED CAPACITY
EXIT ROUTE
SECONDARY ROUTE
LIFE SAFETY DATA
r
DEAD END CORRIDOR
COMMON PATH OF TRAVEL 1 FT. MAX ., 7 —..._.
TRAVEL DISTANCE TO EXITS 3 =T:- MAX...
WALL & CEILING FINISHES IN EXITS & CORRIDORS TO EXITS CLASS A OR CLASS B
WALL & CEILING FINISHES IN OFFICE AREAS CLASS A, CLASS B OR CLASS C
FLOOR FINISHES IN CORRIDORS & EXITS CLASS I OR CLASS II
EXIT CORRIDOR WALL RATING 1 HR.
LI FE SAM
CAPACITY CALCULATIONS
AN
7
=A
OCCUPANCY TYPE BUSINESS
OCCUPANCY LOAD:
THIRD FLOOR WAITING AREA: 249.00 S.F. / 15 S.F. PER PERSON
PILATES CLASS: 1,459.74 S.F. / 50 S.F. PER PERSON
GYM: 1,118.35 S.F. / 50 S.F. PER PERSON
TREATMENT ROOM: MAX. 2 PERSONS PER ROOM x 5
OFFICE: 66.59 S.F. / 100 S.F. PER PERSON
PANTRY: 98.58 S.F. / 30 S.F. PER PERSON
q&0/ter TOTAL
1
FIRE PREVENTION NOTES:
1. ALL FIRE EXTINGUISHERS SHALL HAVE MIN. RATING 2A 20BC AND
SHALL BE MOUNTED 48" A.F.F. TO TOP OF HANDLE AND NOT EXCEED 75°
TRAVEL DISTANCE AND HAVE TO BE CURRENTLY TAGGED BY LICENSED
FIRE EQUIPMENT COMPANY.
2. MAXIMUM CAPACITY SIGN WILL BE PROVIDED AND WILL BE POSTED IN
ACCORDANCE WITH F.F.P.C. (N.F.P.A 101)
3. NUMERICAL ADDRESS TO BE PROVIDED ON ALL EXTERIOR DOORS WITH 6"
NUMBERS WATERPROOF AND CONTRASTING COLORS - NUMBERS TO BE WHITE
IF PLACED ON THE WINDOW AND BLACK IF THEY ARE PLACED ON LIGHT
COLORED DOOR.
4. EACH NEW FIRE WALL, FIRE BARRIER, FIRE PARTITION, SMOKE BARRIER,
SMOKE PARTITION, OR ANY OTHER NEW WALL REQUIRED TO HAVE
PROTECTIVE OPENINGS SHALL BE PERMANENTLY IDENTIFIED WITH SIGNS OR
STENCILING ABOVE ANY DECORATIVE CEILING AND IN CONCEALED SPACES
WITH WORDING "FIRE AND SMOKE BARRIER - PROTECT ALL OPENINGS ", OR
SIMILAR LANGUAGE. SUCH SIGNS OR STENCILING SHALL BE IN 4 INCH HIGH
LETTERS, Y2 INCH STROKE, AND NOT MORE THAN 15 FEET ON- CENTER.
PERSONS
• PERSONS
PERSONS
• PERSONS
1 P•
• E 2S20
PERSONS j
®� �-Tvi
N : ALL DOORS IN
OF EGRE ALL BE SINGLE
ACTION RELEASE AND SHALL NOT
REQUIRE THE USE OF KEY, TOOL
OR SPECIAL KNOWLEDGE.
_
EGRESS WIDTH CALCULATIONS:
EXIT #
S
/CM C,a
EGRESS WIDTH
S&P
REQUIRED
PROVIDED
AS Pet TABLE mall
EXITS
15.6" (2 EXITS)
34" EXIT 1 & 2
1 &2
(0.3' PER OCCUPANT
AS PER TABLE 1005.1)
TOTAL OCCUPANCY: 85 PERSONS
EXITS
10.4" (2 EXITS)
34" EXIT 3 & 4
3 & 4
(0.2- OCCUPANT
1
AS PERETABLEE 10051)
w