11-86-009GENERAL PLUMBING NOTES
1. ALL WORK SHALL CONFORM WITH ALL LOCAL, STATE, FEDERAL
7. PROVIDE MEANS "FURNISH AND INSTALL ".
ORDINANCES AND BUILDING CODES GOVERNING THE
CW /HW
INSTALLATION OF THE PLUMBING SYSTEM. IF WORK AS LAID
8. DO A COMPLETE JOB, EVERYTHING CONNECTED, READY FOR USE.
OUT, INDICATED OR SPECIFIED IS CONTRARY TO OR CONFLICTS
Q
WITH LOCAL ORDINANCES, BUILDING CODES AND REGULATIONS,
9. SHOP DRAWINGS. CONTRACTOR SHALL FURNISH THE ENGINEER
THE CONTRACTOR SHALL REPORT IN WRITING TO THE
WITH SHOP DRAWINGS OF EQUIPMENT PRIOR TO PURCHASE
ARCHITECT /ENGINEER BEFORE SUBMITTING A BID. THE
FOR APPROVAL.
ARCHITECT /ENGINEER WILL THEN ISSUE INSTRUCTIONS AS
HW
HOW TO PROCEED.
10. AT COMPLETION OF JOB THE PLUMBING CONTRACTOR SHALL
CW
GIVE THE OWNER AN AS -BUILT SET OF REPRODUCIBLE SEPIAS
2. THE DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC, NOT
SHOWING THE EXACT LOCATION OF ALL INSTALLATIONS.
NECESSARILY SHOWING IN DETAIL OR TO SCALE ALL OF THE
LAVATORY
MINOR ITEMS. UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE
11. PLUMBING CONTRACTOR SHALL PRESSURE TEST ALL PIPING AS
STRUCTURAL, ARCHITECTURAL AND SITE CONDITIONS SHALL
REQUIRED BY CODE. TEST SHALL BE WITNESSED AND APPROVED
GOVERN THE EXACT LOCATIONS. CONTRACTOR SHALL FOLLOW
BY PROPER AUTHORITIES.
DRAWINGS IN LAYING OUT WORK, CHECK DRAWINGS OF ALL
DISHWASHER
TRADES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED
12. THE PLUMBING CONTRACTOR SHALL WARRANT ALL
AND MAINTAIN MAXIMUM HEAD ROOM, AND SPACE CONDITIONS
WORKMANSHIP AND MATERIALS FOR ONE YEAR FROM THE DATE
AT ALL POINTS. WHERE HEAD ROOM, OR SPACE CONDITIONS
OF FINAL WORK ACCEPTANCE BY OWNER. ANY BREAKDOWN
APPEAR INADEQUATE, ARCHITECT/ ENGINEER SHALL BE
OCCURRING IN FIRST YEAR SHALL BE REPAIRED AT NO EXPENSE
NOTIFIED BEFORE PROCEEDING WITH INSTALLATION. THIS
TO THE OWNER.
CONTRACTOR SHALL, WITHOUT EXTRA CHARGE, MAKE FIELD
FLOOR DRAINS
MODIFICATION IN LAYOUT AS NEEDED TO PREVENT CONFLICT
13. PROVIDE BATHROOM FIXTURES AS SPECIFIED.
WITH WORK OF VARIOUS TRADES OR FOR PROPER EXECUTION
SHOWER
OF THE WORK .
14. PROVIDE SHUT -OFF VALVE FOR EACH FIXTURE.
3. EXAMINE ALL DRAWINGS CAREFULLY PRIOR TO SUBMITTING A BID.
15. WHEREVER NOT SIMILAR METALS ARE TO BE JOINED,
CONTRACTOR WILL BE REQUIRED TO FURNISH, INSTALL AND /OR
A DI- ELECTRIC FITTING SHALL BE PROVIDED TO CONNECT BOTH
CONNECT WITH APPROPRIATE SERVICES ALL PLUMBING ITEMS
TYPES OF PIPES.
SHOWN ON ANY OF THE ARCHITECTURAL, AIR CONDITIONING,
U
w
ELECTRICAL AND SPRINKLER DRAWINGS WITHOUT ADDITIONAL
16. PLUMBING CONTRACTOR SHALL PROVIDE AIR CONDITIONING
EXPENSE TO THE OWNER. IF DISCREPANCIES , CONFLICTS ,
CONDENSATE DRAIN AND TRAP. SEE AIR CONDITIONING PLANS
INTERFERENCE OR OMISSIONS OCCUR BETWEEN DRAWINGS,
FOR LOCATION OF UNITS AND DRAINS.
NOTIFY IN WRITING THE ARCHITECT/ ENGINEER IN AMPLE TIME
17. MATERIALS
TO PERMIT REVISIONS BEFORE THE BIDS ARE SUBMITTED.
A. COLD WATER PIPING DOWNSTREAM OF WATER METER SHALL BE
4. INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND FIRST
TYPE "L" COPPER BELOW GROUND AND TYPE "M" COPPER ABOVE
CLASS WORKMANLIKE MANNER. THE OWNER RESERVES THE
GROUND.
RIGHT TO DIRECT REMOVAL AND REPLACEMENT OF ITEMS WHICH,
B. COLD WATER PIPES INSIDE OF SLAB SHALL BE TYPE "K" SOFT
IN HIS OPINION, DO NOT PRESENT A NEAT AND WORKMANLIKE
COPPER INSTALL INSIDE POLYETHYLENE CONDUIT. NO JOINTS
APPEARANCE. REMOVAL AND REPLACEMENT IS TO BE DONE
PERMITTED INSIDE SLAB.
IMMEDIATELY WHEN DIRECTED BY THE OWNER IN WRITING, AT
THE SOLE EXPENSE OF CONTRACTOR.
C. SANITARY WASTE AND VENT 470 AND SMALLER SHALL BE P.V.C.,
SCHEDULE 40.
5. START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS
D. STORM LINES INSIDE BUILDING SHALL BE P.V.C. SCHEDULE 40
ACCEPTANCE BY HIM OF ALL CLAIMS OR QUESTIONS AS TO
W
SUITABILITY OF THE WORK OF OTHER. TRADES OR OTHER
E IN COASTAL AREAS ALL SANITARY AND STORM PIPING OUTSIDE OF
CONTRACTORS TO RECEIVE HIS WORK. THIS CONTRACTOR
BUILDING SHALL BE SCHEDULE 40, PVC.
SHALL REMOVE AND REPLACE, AT HIS EXPENSE, ALL PLUMBING
F. CONDENSATE DRAIN PIPE SHALL BE SCHEDULE 40, PVC PIPE
WORK WHICH MAY HAVE TO BE REMOVED BECAUSE OF
AND FITTINGS.
INTERFERENCE WITH OTHER TRADES.
G. WATER HEATER RELIEF AND DRAIN LINE SHALL BE TYPE "L" COPPER,
6. THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE,
MIN 314" DIA.
FEES, PERMITS , ASSOCIATION DUES, ROYALTIES AND TAXES OF
O 1 jli
WHATEVER NATURE SHALL APPLY TO THIS WORK. HE SHALL ALSO
FIRE RATED PENETARATION NOTE
PAID ALL THE INSPECTION FEES AS MAY REQUIRED BY LAW OR
WHEN FIRE PENETRATION OF PIPING OCCUR, SHALL BE PROTECTED
ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM ANY
BY ASSEMBLY No. W -L -2088, UL APPRIVED
DAMAGE AND EXPENSE ARISING FROM ANY VIOLATION OF LAWS,
RULES OR ORDINANCES.
WATER PnWW Sd2&2
Q
112 "0
CW /HW
Q
112-0
CW
Q
314 "0
CW, 112 "0 HW
(?)
314-0
CW /HW
Q
112-0
HW
(b)
314-0
CW
(%
1 0 CW
EXIS77NG M
3/4 "0 CWS V
(CS)
112-0 HB
3/4" VACL
BREAKER
NEW
iODA
Ni
=Vom
SITE INVESTIGATION NOTE
EXAMINATION OF CONTRACT DOCUMENTS AND SITE OF WORK: THE BIDDER IS REQUIRED,
BEFORE SUBMITTING HIS PROPOSAL, TO VISIT THE SITE OF THE PROPOSED WORK AND
FAMILIARIZE HIM OR HERSELF WITH THE NATURE AND EXTENT OF THE WORK AND
ANY LOCAL CONDITIONS THAT MAY IN ANY MANNER AFFECT THE WORK TO BE DONE
AND EQUIPMENT, MATERIALS AND LABOR REQUIRED THEREFORE SINCE THE WORK INVOLVES
NEW AND /OR EXISTING BUILDINGS, SYSTEMS AND FACILITIES, SPECIAL CONSIDERATION SHALL
BE GIVEN TO EXAMINATION OF WORKING CONDITIONS, NEW FACILITIES AND ALL BUILDING
STRUCTURES FAMILIARIZE TO HIMSELF WITH ALL EXISTING CONDITIONS. SLIGHT VARIATION
OF ROUTING AND OR CONSTRUCTIONS SHOULD BE ANTICIPATED BY THIS CONTRACTOR TO AVOID
CONFLICTS WITH OTHER TRADES. THESE VARIATIONS ARE EXPRESSLY INCLUDED AS PART OF THE
WORK WHENEVER REQUIRED AT NO ADDITIONAL COST TO THE OWNER. IGNORANCE ON THE PART
OF THE CONTRACTOR WILL IN NO WAY RELIEVE HIM OF THE OBLIGATIONS AND RESPONSIBILITY
ASSUMED UNDER THIS CONTRACT.
SCOPE OF WORK:
THIS JOB CONSIST OF NEW SHOWER INSTALATION ON BATH #1 AS
SHOWN ON PLANS, WATER & SEWER LINES WILL BE CONECTED
THE EXISTING ROUGH.
FIXTURE CONNECTION SCHEDULE
FOR PLUMBING FIXTURES AND FIXTURE FITTINGS
ITEM
WASTE &
SOIL
WATER
COLD
HOT
WATER CLOSET
3"
112"
- -
TUB
2"
1/2"
112"
WHIRLPOOL
2"
112"
112"
BIDET
1 -1/4"
112"
1/2"
LAVATORY
1 -114"
112"
112"
KITCHEN SINK
1 -1/2"
112"
112"
DISHWASHER
1 " hose
- -
1/2"
CLOTHES WASHER
3"
314"
1/2"
HOSE BIBB
_ -
112"
FLOOR DRAINS
2" MIN.
112"
- -
SHOWER
2"
1/2"
1/2"
REFRIGERATOR
- -
112"
- -
NOTE: PROVIDE ANTI SCALD VALVE ® EACH
SHOWER AND TUB
NOTE. ALL TRAPS SHALL BE CONSISTENT W /FIXTURE OUTLET SIZE.
LEGEND:
- - - - - - - DENOTE EXISTING PIPE
- DENOTE COLD WATER PIPE
- - DENOTE HOT WATER PIPE
S400 Gyls
N,
k
NGEN}
0115 C LL
(5
WATER ISOMETRIC-
N. T. S
• . - A - - r -
SCALE: 1/4"= V-0"
HAMMER ARRESTOR:
AMTROL, MODEL 500
- INSTALL IN ACC.. LOCATION.
- CONNECTION SIZE. 112" NPT
HEIGHT. 4 -112"
- DIAMETER: 3 -3/8"
MAX. PRESSURE. 150 PSI
MAX. TEMP: 200' F
MAX. SHOCK PRESSURE. 200 PSI
TO BE INSTALLED IN CWS AND HWS
HIGH POINT FOR EACH GROUP OF
FIXTURE SERVICING.
MAXIMUM FLOW RATE AND CONSUMPTION
FOR PLUMBING FIXTURES AND FIXTURE FITTINGS
PLUMBING FIXTURE
MAXIMUM FLOW RATE
OR FIXTURE FITTING
OR QUANTITY
LAVATOTY, PRIVATE
1.5 GPM 0 60 PSI
LAVATOTY, PUBLIC
0.5 GPM 0 60 PSI
LAVATORY, PUBLIC, METERING
0.25 GALLONS PER METERING CYCLE
OR SELF - CLOSING
SHOWER HEAD
1.5 GPM 0 80 PSI
SINK FAUCET
1.5 GPM 0 60 PSI
URINAL =
WATER LESS OR
0.5 GALLON PER FLUSHING CYCLE
WATER CLOSET
, y 1,28 'GALLON ,PERq FLUSHING CYCLE
DISWASHER (RESIDENTIAL
a
8.5 GALLONS PER CYCLE OR LESS (ENERGY .?
STAR/WATER SENSE CERTIFIED) (C)
DISWASHER ( COMMERCIAL ) -
LESS 774AN 1.2 GALLONS PER RACK FOR FILL do
DUMP MACHINES do LESS THAN 0.9 GALLONS
PER RACK FOR ALL,OTHER TYPES OF MACHINES
DISWASHER (UNDER THE COUNTER
1.0 GALLON 00 LESS' PER RACK FOR HIGH -TEMP.
MACHINES
MACHINES do 1.7 GALLONS PER RACK FOR LOW-
0
TEMPERATURE MACHINES
WASHING MACHINE
WATER FACTOR OF 8 OR LOWER (ENERGY STAR/
WATER SENSE CERTIFIED) (C)
SEWER_
NOTE:
ALL TUB AND SHOWER SHALL BE
ANUSCALDING VALVE 0 110% (TYPICAL)
NOTE:
ALL SANITARY PIPE 2 112 "0 OR SMALLER
SHALL RUN @ 114" SLOPE PER L.FT.
3" AND LARGER 0 1/8" SLOPE PER L.FT.
NOTE:
ALL PLUMBING WATER DEVICE
PROVIDE SHUT -OFF VALVE.
NOTE.
ALL VTR SHALL BE OFF SET
A MIN. OF 4' -0" FROM FIRE
SEPARATION WALL.
NOTE:
ALL PIPES TO DISCHARGE
MIN. 12" FROM STRUCTURE
LEGEND:
0. H - OVER HEAD
U.S - UNDER SLAB
U.G - UNDER GROUND
LEGEND:
- - DENOTE EXISTING PIPE
DENOTE NEW PIPE
DENOTE VENTILATION PIPE
oll pG
J�
�I/�, `1F01
/ 0
PpG.10 /
D�FGGG�� / /�., Ga )
IGO (E}
2'0(2ru)
SANITARY ISOMETRIC
N. T. S.
Revisions
z
0
Q
0
z
W
wQ
w a:
a
_
U
w
W
co ,
Z
W
c /)
r0
o
.e
CL
a
L.L
W
l■•
0
c0p
_
El
z
i
"
O 1 jli
c
C
..I
o
aWE
0 0
c
c
a�
a o
C.
a
=
-0
w
0
0
W
wg C
v 0
'o
�z0�
`a
W
W
L
r
Z
Job No. M 10 =04
Date
01 /24Z1
1
Scale
SHOW N
� �.�( �1b('.
� ♦ ♦ it t
��ii �� 1j`.'�{ ^"�pFRy
AA- 26001.560
Sheet No.
P -1
p.
h a
e
stl
�i
S
u
'
R �1
ae
ya