11-86-008GENERAL HEATING, VENTILATION AND AIR CONDITIONING NOTES 1. ALL WORK SHALL CONFORM WiTH ALL LOCAL STATE, FEDERAL 10. ALL DUCT SIZES ARE CLEAR INSIDE DIMENSIONS. DUCT MOUNTED SMOKE DETECTOR ORDINANCES AND BUILDING CODES GOVERNING THE INSTALLATION OF 11. THE HVAC CONTRACTOR SHALL WARRANT ALL WORKMANSHIP AND and less than 48" THE AIR CONDITIONING SYSTEM AND IN COMPLIANCE WiTH LATEST MATERIALS FOR ONE YEAR FROM THE DATE OF FINAL WORK AiR FLOW DIRECTION ( ARROWS DENOTE ASHRAE AND SMACNA STANDARD. ACCEPTANCE BY OWNER . ANY BREAKDOWN OCCURRING IN FIRST 2. THE DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC, NOT YEAR SHALL BE REPAIRED AT NO EXPENSE TO THE OWNER. THE FIRE RATED ROOF /FLOOR CEILING ASSEMBLY NECESSARILY SHOWING IN DETAIL OR TO SCALE ALL OF THE MINOR COMPRESSOR (S) SHALL HAVE A FIVE YEARS WARRANTY MINIMUM. p ITEMS. UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE STRUCTURAL, 12. MOUNT ALL EQUIPMENT FOR WIND LOADS AND MOUNTING HEIGHTS AS SMOKE CONTROL ARCHITECTURAL AND SiTE CONDITIONS SHALL GOVERN THE EXACT REQUIRED BY LOCAL CODES. J LOCATIONS. CONTRACTOR SHALL FOLLOW DRAWINGS iN LAYING OUT O.A.i. OUTSIDE AIR INTAKE WORK, CHECK WiTH OTHER TRADES TO VERIFY SPACES IN WHICH 13. MATERIALS: CD WORK WILL BE INSTALLED AND MAINTAIN MAXIMUM HEADROOM, AND A. AIR CONDITIONING DUCTWORK SHALL BE CONSTRUCTED OF CEILING GRILLE SPACE CONDITIONS AT WHERE HEADROOM , OR SPACE CONDITIONS CODE GAUGE GALVANIZED METAL DUCT WITH 1 -112" THICK R =40f F.L.O APPEAR INADEQUATE, NOTIFY THE ARCHITECT /ENGINEER. WRAP AROUND STANDARD DUTY FIBERGLASS BOARD FLAMEPROOF CONDENSING UNiT AHU REINFORCED ALUMINUM FACED COVER IN ACCORDANCE WITH THE J. AFTER EXAMINATION OF CONTRACT DOCUMENTS AND SITE OF S.M.A.C.N.A. AS MANUFACTURED BY OWNERS — COMING. DUCTWORK ROOF TOP UNiT CONDITIONS. THE BIDDER iS REQUIRED, BEFORE SUBMITTING HiS SHALL BE FABRICATED AND INSTALLED ACCORDING WiTH MANUFACTURER'S PROPOSAL, TO FAMILIARIZE HIM OR HERSELF WiTH THE NATURE AND INSTRUCTIONS INSTALL AiR VOLUME EXTRACTORS AT EACH DUCT EXTENT OF THE WORK AND ANY LOCAL CONDITIONS THAT MAY IN ANY TAP. MANNER AFFECT THE WORK TO BE DONE AND EQUIPMENT, MATERIALS AND LABOR REQUIRED THEREFORE, SINCE THE WORK INVOLVES NEW B. FLEXIBLE DUCTWORK SHALL BE CLASS i AiR DUCT, U.L. 181 LISTED BUILDINGS, SYSTEMS, SPECIAL CONSIDERATION SHALL BE GIVEN TO AS FOR CONDITIONED SPACE R 4.0 AND BUILT iN ACCORDANCE WiTH THE WORKING CONDITIONS. SLIGHT VARIATION OF ROUTING AND OR THE FOLLOWING REQUIREMENTS. CONSTRUCTIONS SHOULD BE ANTICIPATED BY THiS CONTRACTOR TO AVOID CONFLICTS WITH OTHER TRADES. THESE VARIATIONS ARE 1. BENDS SHALL MAINTAIN A CENTERLINE RADIUS OF NOT LESS EXPRESSLY INCLUDED AS PART OF THE WORK WHENEVER REQUIRED AT THAN ONE DUCT DIAMETER. NO ADDITIONAL COST TO THE OWNER. IGNORANCE ON THE PART OF 2. TERMINAL DEVICES SHALL BE SUPPORTED INDEPENDENTLY OF THE CONTRACTOR WiLL IN NO WAY RELIEVE HIM OF THE OBLIGATIONS THE FLEXIBLE DUCT. AND RESPONSIBILITY ASSUMED UNDER THE CONTRACT. THE 3. DUCTS SHALL BE INSTALLED FULLY EXTENDED, THE TOTAL CONTRACTOR SHALL REPORT IN WRITING TO THE ARCHITECT /ENGINEER. EXTENDED LENGTH OF DUCT MATERIAL SHALL NOT EXCEED 5 BEFORE SUBMITTING A BID. IF ANY DISCREPANCIES ARE PERCENT OF THE MINIMUM REQUIRED LENGTH FOR THAT RUN. ENCOUNTERED, THEN WE WILL ISSUE INSTRUCTIONS HOW TO PROCEED. D. TOILET EXHAUST DUCTWORK SHALL BE GALVANIZED SHEET 26 4. INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND WORKMANLIKE GAUGE METAL DUCT INSTALLED IN ACCORDANCE WiTH THE LATEST MANNER, THE OWNER RESERVES THE RIGHT TO REQUIRE OR REMOVAL ASHRAE STANDARDS AND MANUFACTURERS RECOMMENDATIONS. THE PLACEMENT OF ITEMS WHICH WERE NOT RIGHT. E. ALL AiR DEVICES SHALL BE OF ALUMINUM CONSTRUCTION, TITUS, 5. THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE , FEES, METALAIRE OR AS APPROVED BY ENGINEER. PERMITS, ROYALTIES, AND TAXES OF WHATEVER NATURE SHALL APPLY TO THiS WORK. HE SHALL ALSO PAY ALL INSPECTIONS FEES AND F. CONDENSATE DRAIN — SHALL BE INSULATED WiTH 314" THICK SHALL KEEP THE OWNER HARMLESS FROM ANY DAMAGE AND EXPENSE ARMAFLEX. WHEN EXPOSED iN CONDITIONED SPACE. iF THE PiPE- ASSURING FROM ANY VIOLATION OF THE LAWS, RULES, OR RUN THRU A RETURN PLENUM, THEN AN COMBUSTIBLE MATERIAL ORDINANCES. IS TO BE PROVIDED iN PLENUM SiDE. 6. PROVIDE MEANS FURNISH AND INSTALL" 7. SHOP DRAWINGS: THIS CONTRACTOR SHALL FURNISH THE ENGINEER WiTH SHOP DRAWINGS OF EQUIPMENT AND DEVICES PRIOR TO PURCHASE FOR APPROVAL AND ACCEPTANCE 8. AT COMPLETION OF JOB THE HVAC CONTRACTOR SHALL GiVE THE OWNER AN AS —BUILT SET OF REPRODUCIBLE SEPIAS SHOWING THE EXACT INSTALLATION. iF ANY DEVIATIONS OCCUR FROM THiS, SET OF CONTRACT DOCUMENTS. 9. BETWEEN THE UNiTS OR SPACES THE HVAC CONTRACTOR SHALL TEST AND BALANCE THE AIR QUANTITIES SHOWN ON THE PLANS, PROVIDE T & B REPORTS IN ACCORDANCE WiTH AiR BALANCE COUNCIL STANDARDS, SIGNED AND SEALED BY A FLORIDA REGISTERED ENGINEER. SITE INVESTIGATION NOTE EXAMINATION OF CONTRACT DOCUMENTS AND SiTE OF WORK. THE BIDDER IS REQUIRED, BEFORE SUBMITTING HIS PROPOSAL, TO VISIT THE SiTE OF THE PROPOSED WORK AND FAMILIARIZE HiM OR HERSELF WiTH THE NATURE AND EXTENT OF THE WORK AND ANY LOCAL CONDITIONS THAT MAY IN ANY MANNER AFFECT THE WORK TO BE DONE AND EQUIPMENT, MATERIALS AND LABOR REQUIRED THEREFORE. SINCE THE WORK INVOLVES NEW AND /OR EXISTING BUILDINGS, SYSTEMS AND FACILITIES, SPECIAL CONSIDERATION SHALL BE GIVEN TO EXAMINATION OF WORKING CONDITIONS, NEW FACILITIES AND ALL BUILDING STRUCTURES FAMILIARIZE TO HIMSELF WiTH ALL EXISTING CONDITIONS. SLIGHT VARIATION OF ROUTING AND OR CONSTRUCTIONS SHOULD BE ANTICIPATED BY THiS CONTRACTOR TO AVOID CONFLICTS WiTH OTHER TRADES. THESE VARIATIONS ARE EXPRESSLY INCLUDED AS PART OF THE WORK WHENEVER REQUIRED AT NO ADDITIONAL COST TO THE OWNER. IGNORANCE ON THE PART OF THE CONTRACTOR WiLL IN NO WAY RELIEVE HiM OF THE OBLIGATIONS AND RESPONSIBILITY ASSUMED UNDER THiS CONTRACT. LEGEND R 24X24 CD —(SEE SCHEDULE) DUCT TO MATCH NECK SiZE TYP. r y CEILING GRILLE SEE SIZE SCHEDULE ® DUCT TO MATCH NECK SiZE TYP. RAG —( RETURN AIR GRILL)) VOLUME DAMPER �} THERMOSTAT NOTE. OAi SHALL BE MiNIMUM 10 FEET HORIZONTAL DISTANCE FROM ALL VENTS. NOTE: ALL MATERIALS USE INTO THE AIR PLENUM RETURN CLOSET & OPEN CEILING SPACE SHALL BE NONCOMBUSTIBLE MATERIAL. LOW VELOCITY SUPPLY AIR DUCT (SEE PLAN VIEW) METAL ROUND FITTING QUADRANT OPERATOR TO BE OUTSIDE INSULATION PROVIDE INSULATION GUARD WHERE NECESSARY PROVIDE 1" FIBERGLASS INSULATION SEALED TO TO NECK & PERIMETER OF DIFFUSER PERFORATED DIFFUSER —. 1314 i • 11,80i SCOPE OF WORK: INSULATED FLEX. (8' -0" MAXIMUM) (THERMOFIN OR EQUAL) SEAL JOINT W/ DUCT SEALER & TAPE THIS JOB CONSIST OF NEW DUCT WORK LAYOUTS FOR TWO EXISTING A/C UNITS DUE TO AN INTERIOR REMODELING IN AN EXISTING OFFICES BUILDING. THE TWO 4 TON SPLIT SYSTEM ARE TO REMAIN. (SEE SCHEDULE). NO ENERGY AND HEAT LOAD CALCULATIONS ARE REQUIRED AT THIS TIME. STANDARD 3" WIDE HANGERS Hanget extension to be the sum of the distances between the hanging wires and the duct size, ID (Smacna Duct size, Inches DD 48: Wide or grater DUCT MOUNTED SMOKE DETECTOR Less tho 48" wide Eft and less than 48" SEE F.A. RISER FOR SPECS. deep AiR FLOW DIRECTION ( ARROWS DENOTE —� 1 WAY, 2 WAY, ETC., SEE PLANS —�—"" RETURN OR EXHAUST, SEE PLANS. than 16" deep FIRE RATED ROOF /FLOOR CEILING ASSEMBLY Less then 29" wide 8ft p WALL MOUNTED SiDE REGISTER. X SMOKE CONTROL LTJ EXHAUST FAN J FIRE DAMPER O.A.i. OUTSIDE AIR INTAKE S.R. SIDE REGISTER CD CEILING DIFFUSER CG CEILING GRILLE H.P. HEAT PUMP UNiT F.L.O FULL LOUVERED DOOR CU CONDENSING UNiT AHU AiR HANDLER UNiT UC UNDERCUT DOOR FOR AiR RETURN RTU ROOF TOP UNiT VD MANUAL VOLUME DAMPER NOTE. OAi SHALL BE MiNIMUM 10 FEET HORIZONTAL DISTANCE FROM ALL VENTS. NOTE: ALL MATERIALS USE INTO THE AIR PLENUM RETURN CLOSET & OPEN CEILING SPACE SHALL BE NONCOMBUSTIBLE MATERIAL. LOW VELOCITY SUPPLY AIR DUCT (SEE PLAN VIEW) METAL ROUND FITTING QUADRANT OPERATOR TO BE OUTSIDE INSULATION PROVIDE INSULATION GUARD WHERE NECESSARY PROVIDE 1" FIBERGLASS INSULATION SEALED TO TO NECK & PERIMETER OF DIFFUSER PERFORATED DIFFUSER —. 1314 i • 11,80i SCOPE OF WORK: INSULATED FLEX. (8' -0" MAXIMUM) (THERMOFIN OR EQUAL) SEAL JOINT W/ DUCT SEALER & TAPE THIS JOB CONSIST OF NEW DUCT WORK LAYOUTS FOR TWO EXISTING A/C UNITS DUE TO AN INTERIOR REMODELING IN AN EXISTING OFFICES BUILDING. THE TWO 4 TON SPLIT SYSTEM ARE TO REMAIN. (SEE SCHEDULE). NO ENERGY AND HEAT LOAD CALCULATIONS ARE REQUIRED AT THIS TIME. STANDARD 3" WIDE HANGERS Hanget extension to be the sum of the distances between the hanging wires and the duct size, ID (Smacna Duct size, Inches Maximum Hange Spacing 48: Wide or grater 4 ft Less tho 48" wide Eft and less than 48" deep SMOKE DAMPERS Width between 28" Eft & 48" and greater than 16" deep FIRE RATED ROOF /FLOOR CEILING ASSEMBLY Less then 29" wide 8ft and 16 depth or less CHANNEL SECTION if Total Minimum Minimum Extension is Channel Channel not greater than: Gauge Profile 6" 24 3" X 1.5" 18" 22 3" X 2" 30" 18 3" X 2" USE OF 2" WiDE 22 gauge 2x 1.5" hangers may be substituted for 3" hangers for ducts with widths not over 48" and depths not over 24" provided that not more than one joint occurs between hangers and the maximum hanger spacing 4ft. Exception: When duct perimeter is 80" or less and does not require reinforcement two joints are permitted 314" DEEP x 118", OWERED ACTU TEn N. FLE FLEXIBLE DUCT SHALL BE SUPPORTED AT INTERVALS NO GREATER THAN 5 FEET. P DUCT HANG DETAIL x26GA AT s 2 -112" SQUARE WAS 12" MAX. O.C., MIN. 10 X 1 -1 /4" METAL SCREWS. FIBROUS GLASS DUCT. GFM CLOSURE. SCREW. POP RIVET OR SPOT WELD TO EQUIPMENT FLANGE. A. H. U PLENUM C O NNE C TIO N. N.T_S_ HVAC DESIGN REQUIRE: YES NO DUCT SMOKE DETECTOR X FIRE DAMPER(S) X SMOKE DAMPERS X FIRE RATE ENCLOSURE X FIRE RATED ROOF /FLOOR CEILING ASSEMBLY X FIRE STOPPING X SMOKE CONTROL X CFM OAi MECHAN %.#P%L PLAN SCALE: 1/4"= V-0' Revisions . 'l5 i= 0 LL Z %9 0 Q o a Z W W Q o Z WFrew >0 LL _ W co C6 —� innn Q 0Z) W r 0 VJ O �o CL o rr CL ■ R �t oWTE W goo o @ . = o Wo I= C > o i` C.91 <d0p o ■ 00 ZQ�� M)W t ■ J .5 � 2 Job No. M10 -04 Date 01 Z24/11 Scale SHOWN Y64 Sea] °,.,a� �O'l AA- 26001560 Sheet No. MA