Loading...
11-86-006NORTH PROPOSED REFLECTED CEILING PLAN SCALE : I/4" = V -O" PROPOSED FLOOR PLAN SCALE : 1/4" = V -0" NORTH ^,Ak 8 WALL LEGEND SYMBOL DESCRIPTION Revisions EXISTING 8" CBS WALL TO REMAIN GENERAL. NOTES EXISTING (I HR) FIRE RATED DEMISING WALL. FIRE RATING SHALL BE MAINTAINED AT ALL TIMES. - NEW INTERIOR PARTITIONS, BEE WALL TYPES ON SHEET A -6.0 FOR INFORMATION. CONTRACTOR SHALL PROVIDE PROTECTION OF MATERIALS DURING; ALL PHASES OF CONSTRUCTION.CONTRACTOR SHALL BE RESPONSIBLE FOR IMMEDIATE CLEANING AND REMOVAL ® SUPPLY AIR OF ALL DEBRIS UNTIL THE PREMISES ARE ACCEPTED IN A CLEAN AND HABITABLE CONDITION BY THE ARCHITECT /INTERIOR DESIGNER ` CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY THAT ALL WORK OF ALL TRADES SHALL COMPLY WITH THE FLORIDA BUILDING CODES. ® RETURN AIR CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS IN THE FIELD AND SHALL IMMEDIATELY NOTIFY THE ARCH. /DESIGNER OF ANY CONDITION THAT DIFFER OR INTERFERES WITH - THOSE SHOWN ON THIS PLAN BEFORE PROCEEDING WITH WORK ALL DIMENSIONS SUPERSEDE SCALED DRAWINGS. LIMITED TO INFERIOR WORKMANSHIP OR MATERIALS, IMPROPER SCHEDULING • OR DELINQUENT ORDERING SHALL BE BORNE BY PARTY RESPONSIBLE. rr - THE GENERAL CONTRACTOR, HIS SUB - CONTRACTOR, OR ANY OTHER CONTRACTOR INVOLVED IN THIS PROJECT SHALL TAKE NOTE THAT ANY COST CAUSED BY DEFECTIVE WORK, AS A RESULT OF, BUT NOT O ALL ITEMS DAMAGED WHILE IN DEMOLITION PHASE THAT ARE TO REMAIN SMALL BE RESTORED OR REPLACED TO BE ACCEPTABLE BY THE ARCHITECT / INTERIOR DESIGNER, AT THE CONTRACTORS ` EXPENSE. ANY CONCERNS OF UNFORESEEN CONDITIONS ENCOUNTERED DURING THE DEMOLITION PHASE SHALL z BE REPORTED IMMEDIATELY TO THE ARCHITECT / INTERIOR DESIGNER FOR EVALUATION. ^ WALL LEGEND SYMBOL DESCRIPTION SYMBOL EXISTING 8" CBS WALL TO REMAIN SP EXISTING (I HR) FIRE RATED DEMISING WALL. FIRE RATING SHALL BE MAINTAINED AT ALL TIMES. D NEW INTERIOR PARTITIONS, BEE WALL TYPES ON SHEET A -6.0 FOR INFORMATION. LEGEND: SYMBOL DESCRIPTION SYMBOL DESCRIPTION SP EXISTING SPRINKLER HEAD ® SUPPLY AIR p ELECTRIC PANEL EXIT LIGHT WITH EMERGENCY ® RETURN AIR FLOODLIGHTS (COMBO) ® EXHAUST �I HID OR FLUORESCENT WALL lJl MOUNTED LIGHT FIXTURE SURFACE OR PENDANT MOUNTED LIGHT FIXTURE NEW 2' X 2' ACT TILE Do RECESSED LIGHTING TRACK LIGHT FIXTURE I,::,* EMERGENCY LIGHT FIRE ALARM PULL N HORN / STROBE DEVICE 4 WALL MOUNTED FIRE EXTINGUISHER FA FIRE STROBE ALARM Fx`sr (R) EXISTING RELOCATED 2'x 4' FLUORESCENT LIGHTING ® EXHAUST FAN. V TELEPHONE. { FIXTURES ARE TO BE SELECTED BY OWNER AND APPROVED BY ARCHTIECT PRIOR TO INSTALLATION. PROJECT NO 1 E `• : REFLECTED CEILING PLAN WORIG CONSISTS OF: e 1. NEW EXPOSED MECHANICAL DUCT WORK IN 'NEW OPEN OFFICE LAYOUT SPACES. 2. RELOCTING EXISTING 2X4 FLOURESCENT LIGHTING FIXTURE FOR REVISED PLAN IVAG 3. NEW 2 x 2 CEILING TILE IN EXECUTIVE OFFICE 01 AND "2 'a0 L, 4 VERIFICATION OF ALL REQUIRED LIFE - SAFETY DEVICES. PROJECT NOTES: PROPOSED PLAN WORK CONSISTS OF: 1. NEW PRE - FABRICATED SHOWER TO BE PLACED IN EXISTING BATHROOM 01. 1/2' THICK DRYWALL CEILMCsONIX3WD. FURRINCs • 16" OZ. 5/S• DRYWALLS BOTH SIDES INTERIOR 6' BASEBOARD - PROFILE TO BE SELECTED BY OWNER FINSIH FLOOR — TO BE SELECTED BY OWNER EXIST. C24C, STRUCT. AND SLAB FASTEN 20 " RUNNIER TO SLAB W/ 'HILTL' SHOT PINS DNI 31PS (SHANK DIA..145) a 16" OTC. SEAL BOTH SIDES. INTERIOR PARTITION 20 GAUGE MTL STUDS AT 16. O.C. MTL. STUD ISRACINCsS AT MID -DEPTH (FIRE STOP) .0 �u TYPICAL NOM -LOAD SEARING 1 INTERIOR PARTITION SCALE- 1/2" = t' -Om Pn .4„ ! ^SA .. .r, fi,r„ �... _ v w d .n a. mom`.. >r. 43 k FES * 2011, Q Q z L wQ z9 L M 0 I O ry, L �� Z C) 0 �. W r a a_ cl) LO I � C a L. L" 00 N N C -0 QW u a � a LuN cu 4 a� F- a > - o. IQL W 0 O Q 0 C. o W C m o �0 c < w co •• • O Date Q Sheet No. -.V_111 O •• • O Date Q Sheet No. -.V_111