Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
11-86-005
PROJ E C I NOTE E S: DEMOLITION PLAN WORK CON515T5 OF: I I PROTECTION OF ALL WALL FINISHES (EXCEPT WHERE NOTED FOR DEMOLITION). 2 COMPLETE REMOVAL AND DISPOSAL OF EXISTING WALLS AND DOOR 3 COMPLETE REMOVAL AND DISPOSAL OF EXI5TING.URINAL. 4 SAWCUT AND REMOVE OF FLOOR SLAB TO CREATE TRENCHING (CONTRACTOR TO COORDINATE 51ZING REQUIRED) FOR PLUMBING AND ELECTRICAL. 5, EXISTING DUCTWORK FOR AHU 01 AND AHU 02 TO BE REMOVED AND REPLACED WITH NEW DUCTS. SEE MECHANICAL DRAWINGS FOR MORE INFORMATION. NORTH DEMOLITION FLOOR PLAN � ..pRa°JF 111 GENERAL NOTES CONTRACTOR SHALL PROVIDE PROTECTION OF MATERIALS DURING ALL PHASES OF CON5TRUCTION.CONTRACTOR SHALL BE RESPONSIBLE FOR IMMEDIATE CLEANING AND REMOVIAL- OF ALL DEBRIS UNTIL THE PREMISES ARE ACCEPTED IN A CLEAN AND HABITABLE CONDITION BY THE ARCHITECT /INTERIOR DESIGNER CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY THAT ALL WORK OF ALL TRADES SHALL COMPLY WITH THE FLORIDA BUILDING CODES. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS IN THE FIELD AND SHALL IMMEDIATELY NOTIFY THE ARCH. /DESIGNER OF ANY CONDITION THAT DIFFER OR INTERFERES WITH THOSE SHOWN ON THIS PLAN BEFORE PROCEEDING WITH WORK. ALL DIMENSIONS SUPERSEDE SCALED DRAWINGS. LIMITED TO INFERIOR WORKMANSHIP OR MATERIALS, IMPROPER SCHEDULING OR DELINQUENT ORDERING SHALL BE BORNE BY PARTY RESPONSIBLE. THE GENERAL CONTRACTOR, HIS SUB - CONTRACTOR, OR ANY OTHER CONTRACTOR INVOLVED IN THIS PROJECT SHALL TAKE NOTE THAT ANY C05T CAUSED BY DEFECTIVE WORK, AS A RESULT OF, BUT NOT ALL ITEMS DAMAGED WHILE IN DEMOLITION PHASE THAT ARE TO REMAIN SHALL BE RESTORED OR REPLACED TO BE ACCEPTABLE BY THE ARCHITECT / INTERIOR DESIGNER, AT THE CONTRACTORS EXPENSE. ANY CONCERNS OF UNFORESEEN CONDITIONS ENCOUNTERED DURING THE DEMOLITION PHASE SHALL BE REPORTED IMMEDIATELY TO THE ARCHITECT / INTERIOR DESIGNER FOR EVALUATION. WALL LEGEND SYMBOL DESCRIPTION EXIT LIGHT WITH FLOODLIGHTS EXISTING S" CBS WALL TO REMAIN D EXISTING INTERIOR PARTITIONS TO REMAIN FUORESCENT LIGHT FIXTURE EXISTING TO BE REMOVED OR DEMOLISHED EXHAUST FAN. EXISTING CONCRETE SLAB TO BE CUT 4 REMOVED FOR NEW SHOWER SEE PROPOSED FLOOR PLAN FOR LOCATION OF SHOWER AND LAYOUT. LEGEND: SYMBOL7 DESCRIPTION SP EXISTING SPRINKLER HEAD EXIT LIGHT WITH FLOODLIGHTS V X 4' SURFACE OR PENDANT MOUNTED FUORESCENT LIGHT FIXTURE © EXHAUST FAN. • FIXTURES ARE TO BE SELECTED BY OWNER AND APPROVED BY ARGHTIECT PRIOR TO INSTALLATION. DEMOLITION NOTES: I. ALL DEMOLITION WORK SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE 2001 FLORIDA BUILDING CODE CHAPTER 33 AND COMPLY WITH ALL GOVERNING REGULATIONS. 2. GENERAL CONTRACTOR TO SURVEY THE CONDITION OF THE BUILDING TO DETERMINE WHETHER REMOVING ANY ELEMENT MIGHT RESULT IN STRUCTURAL DEFICIENCY OR UNPLANNED COLLAPSE OF ANY PORTION OF THE STRUCTURE OR ADJACENT STRUCTURES PRIOR DEMOLITION SCHEDULE. CONTRACTOR TO CONTACT ARCHITECT IMMEDIATELY PRIOR TO REMOVING ANY CONCRETE OR OTHER STRUCTURAL ITEM. 3. PRIOR TO COMMENCEMENT OF WORK, CONTRACTOR SHALL SUBMIT A MAINTENANCE OF PEDESTRIAN TRAFFIC (M.O.T.) PLANS FOR OWNER / LANDLORD APPROVAL. CONTRACTOR SHALL INDICATE ALL TEMPORARY WALLS REQUIRED, INTERMEDIATE SIGNAGE, AND M.O.T. INFORMATION. 4. COORDINATE ALL DEMOLTION WORK WITH ALL OTHERS TO INSURE WORK WILL PROGRESS WITHOUT INTERUPTION AND DELAYS. COORDINATE AND SCHEDULE THE WORK WITH THE OWNER / LANDLORD WHERE POSSIBLE DISTURBANCE MAY OCCUR AND OTHER POTENTIAL DISRUPTIONS OF OWNERS FUNCTIONS AND SERVICES MAY OCCUR ALL WORK AFFECTING OWNER'5 FUNCTIONS AND ACTIVITIES, INCLUDING ACCOMPLISHING WORK, TO BE COMPLETED BY PHASING WITH OWNER'S APPROVAL 5. ALL AREAS OUTSIDE OF INDICATED "SCOPE OF WORK" SHALL REMAIN UNDISTURBED UNLESS OTHERWISE NOTED. 6. CONTRACTOR SHALL BE RESPONSIBLE TO FIELD CHECK AND VERIFY ALL CONDITIONS PRIOR TO COMMENCEMENT OF DEMOLITION, AND NOTIFY THE OWNER AND ARCHITECT IF ANY DISCREPANCIES ARE FOUND. 1. THE CONTRACTOR IS TO PROTECT ALL EXISTING FINISHES AND SURFACES THROUGHOUT SPACE WHICH ARE NOT PART OF DEMOLITION, INCLUDING ALL EXISTING ELEVATORS, STAIRCASES,, ENTRANCE LOBBIES, STORE FRONTS, AND SERVICE AREAS. THE CONTRACTOR WILL REPLACE OR REFINISH DAMAGED AREAS. PLACE PLYWOOD OR OTHER PROTECTIVE COATING OVER GRANITE d FABRIC PANELS AT FLOORS AND WALLS IF DESIGNATED TO REMAIN. S. DEMOLITION DRAWINGS AND NOTES ARE ONLY TO A551ST IN SHOWING THE SCOPE OF DEMOLITION WORK AND IS NOT INTENDED TO INDICATE ALL DEMOLITION. CONTRACTOR SHALL REMOVE ALL EXISTING ITEMS FOR A "BROOM CLEAN" SPACE. 9. CONTRACTOR SHALL PROTECT ALL EXISTING FACILITIES AND SITE UTILITIES FROM DAMAGE. 10.CONTRACTOR 15 TO REMOVE OR CAP MECHANICAL ITEMS WHICH ARE NOT TO BE REUSED INCLUDING WIRING, CONDUITS, PIPES, DUCTWORK, ETC. I1.CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING A TRASH/DEBRIS REMOVAL SERVICE FOR REMOVAL OF ALL DEBRIS FOR ALL TRADES AND WALL WORK RELATING TO THIS PROJECT. COORDINATE LOCATION OF DUMPSTER WITH OWNER 12.WIRING 15 TO BE REMOVED BACK TO PANEL. WORK TO BE DONE BY AN ELECTRICAL CONTRACTOR CARE SHOULD BE TAKEN TO IDENTIFY ALL ELECTRICAL CONDUITS WHICH WILL REMAIN FOR BUILDING SYSTEMS AND TAGGED TO REMAIN. 13.PERIMETER GLAZING TO REMAIN SHALL HAVE PRECAUTIONS TAKEN TO PROTECT MATERIALS DURING CONSTRUCTION. CONTRACTOR WILL REPLACE ALL GLASS BROKEN DURING DEMOLITION. 14.ALL LIGHTING FIXTURES ARE TO BE REMOVED AND STORED FOR POSSIBLE REUSE ON THE PROJECT UNLESS OTHERWISE NOTED. 15.UPON COMPLETION OF DEMOLITION WORK, CONTRACTOR SHALL REMOVE TOOLS, EQUIPMENT, AND DEMOLISHED MATERIALS FROM SITE. REMOVE PROTECTIONS, DEBRIS, RUBBISH, AND OTHER MATERIALS RESULTING FROM DEMOLITION WORK FROM BUILDING SITE. TRANSPORT AND LEGALLY DISPOSE OF MATERIALS OFF -SITE. B i9 Revisions o _ z� W W Cc ff W ,o o < -C) Cc W �: � Q. 0 W TO 0 rr L.J.. 0 J o 0 v -co v z L 00 00 N ` cv LO 0 ° LL 0 �. W co a m 0 LO c N (10 O C 0 Q 6 Q IL dt 0 Q uj W pia 0 C13 U) cl) c >� p L N Q O a LL - o R Q 'm o U. � U. v Q} p� U T ca to . N 7 Q u o• No -04 . late 1I1 I I i A s � Sheet No. A � 2',