Loading...
11-86-002Li Li Ll I EXISTING 101b. ABC FIRE EXTINGUISHER IN STANDARD MOUNT I NEW OPEN- L- 115 1 e-)== I e- = I R '+r �EX15TI BAT #2 #1 SPACE #1 OFFICE &FACE INTERIOR REVONVATION I,�A-I C Qn FT. EXISTING 101b. ,45C FIRE EXTINGUISHER r _ I 17 PERSONS �� ��� IN STANDARD MOUNT L---------------------------- A$'----- - - - - -- - - - - -- I91�------------------------------------------------- 10----------------------------------- - - - - -, rod A.H.0 PROPOSED EXECUTIVE EXECUTIV #2 OFFICE #3 OFFICE #2 OFFICE #1 25ro S.F. 145 S.F. 120 S.F. EXISTING — BATH #1 I I E ISTING I d LECT. RM. 3 PERSONS n Li-i GENERAL NOTES: 2 PERSONS 2 PERSONS 1. BUILDING 15 GOING TO BE OCCUPIED BY ONE TENANT ONLY. 2. SPACE DOES NOT HAVE FIRE SPRINKLER SYSTEM OR FIRE ALARM, CALL LIFE SAFETY DEVICES TO REMAIN UNDISTURBED AND FUNCTIONING DURING CONSTRUCTION. 3. FLOOR SURFACE ON BOTH SIDES OF DOORS MUST NOT HAVE LESS THAT THE WIDTH OF THE DOOR. 4. PROPOSED OCCUPANCY TO BE (B) WITH OCCUPANT LOAD OF (2a) PERSONS. SEE LIFE SAFETY STATEMENT AND OCCUPANCY BREAKDOWNS ON THIS SHEET FOR MORE INFORMATION. 6YM50L LEGEND: SYMBOL 1 DESCRIPTION _ FIRE REVIEW 2 -05 -11 SMOKE DETECTOR FA FIRE ALARM / STROBE EXIT LIGHT FP FIRE PULL STATION F 10 Ib ABC FIRE EXTINGUISHER 0 SP EXIST. SPRINKLER HEAD OEM EXIST. I HOUR FIRE RATED WALL EXIST, S" C.B.S. WALL — —� PATH OF EGRE55 EXIST. CONC. COLUMN E WALLS 0 NEW INTERIOR PARTITION EMERGENCY EXIT LIGHTS H< HORN / STROBE DEVICE z FIRE EXTINGU16HER / WALL NOTES: FIRE AND OR SMOKE SEPARATION WALLS AND PARTITIONS MUST BE NOTED WITH STENCILED SIGN AS PER FBC -1042.1.4 CONTRACTOR SHALL PROVIDE ONE ABC TYPE FIRE EXTINGU15HER FOR EVERY 3,000 SQUARE FEET OF BUILDING AREA. EXTINGUISHER SHALL BE MOUNTED AT 60" A.F.F. MAXIMUM. PROVIDE EXTINGUISHER IN STANDARD MOUNT AS PER MANUFACTURER SPECIFICATIONS. COORDINATE LOCATION WITH OWNER PRIOR TO INSTALLATION. NORTH LIFE 5AFET`�i PLAN SCALE . I 41' FIRE 5fi=RINKLER / ALARM SYSTEM INFORMATION THE SCOPE OF WORK CONSISTS OF INTERIOR ALTERATION IN A TYPE IIA BUILDING. THE LEASE SPACE HAS TWO EXISTING EXITS THE BUILDING 15 NOT SPRINKLED 4 DOES NOT HAVE A FIRE ALARM SYSTEM. 3 MINIMUM REQUIRED FLAME SPREAD CLASSIFICATION FOR INTERIOR FINISHES USE MINIMUM CLASS "C" INTERIOR FINISHES AND MATERIAL THROUGHOUT BUILDING AS PER F.F.P.C. CLASS 'C' FLAME SPREAD -16.200 AND SMOKE DEVELOPMENT D -450 PER A5TM E 84. OCCUPANCY BREA<DOWN TYPE OF USE: (B) BUSINESS = 1/100 5QFT. GROSS GENERAL OPEN OFFICE SPACE 01 GENERAL OPEN OFFICE SPACE *2 OFFICE a 1 OFFICE * 2 OFFICE # 3 TOTAL OCCUPANT: 2,145 5Q. FT. / 100 GROSS = 2-1.45 LOAD TOTAL SQUARE FOOTAGE 1,64-1 SQ. FT. 511 SQ. FT. 120 5Q. FT. %V1 i H TIi '°r Oi'1�I IN THF FL 145 SQ, FT, 256 50. FT`S L� � r >2,-45 SQ. . 4� —'- F;R2 €are, €a- ..,; nV! CeU Ie1 Revisions _ FIRE REVIEW 2 -05 -11 I Ie1 Revisions _ FIRE REVIEW 2 -05 -11 0 LL z 0 0 z w w4 CC �o z_ rr w oc QO L.f w : --- - w � � z� 0 o� W T- 0 Cl) r--U) 0 n 0 T n .J Z L .� Cl) cv) UD co N —y l \T N Lr) LL r V, 0 c) oW� u o CD 'I in Lu It O C N Q c a m Q � a 0 pWG 0 � O � Q ILI C 0 L E Q rt, UP o M •Z 044 �� U n 41 0 W co8 Q co co m T • U z aU W U a Job No. M10 -04 Date 02/08/11 Scale SHOWN r b AA-' 26001560 fleet No. z =1.