11-1278-001I
0i
I
N
z
O
I
D0
r-1
#7050 Limits of Work
F-
2
CZ L7
LLJ
N =
a
L.�
O
I �
60 Z
•--I Q
Lv
7-
LIVV LVlvl_
7.2 FEET4 " =1 ' -0" 75' -0" Not To Scale
USE AND OCCUPANCY:
The existing Multi Family Building is "R -2" per
Florida Building Code 2007- Building Chapter 3,
Section 310 - Residential Group R.
FBC ALTERATION LEVEL 1
In accordance with the Florida Building Code
2007- Existing Building: Removal and
Replacement of Windows/Doors as indicated on
this sheet is a LEVEL 1 Alteration per Section
403.1
Per FBC Existing Buildings ALTERATION
LEVEL 1, Sec. 403.2 Building work shall
comply with the Florida Building Code 2007 -
Existing Building, Sections; 601 -607 & 612.
I
I O
7.2 FE
o �
WINDOW/DOOR SCHEDULE 0
NOTE: New windows /door ARE Dade County Large Missle Approved.
E Existing window or door to remain or Not In Contract
A ES Windows, Series 1000/1050 Aluminum Single Hung Window - L.M.I. , 19A" x 744" high.
Dade County Product Approval # 09- 1008.05, Expiration 11/6/2013
Approved Wind Pressure = +70.0 PSF, -80.0 PSF
(Equal Lites, Minimum "Standard Top Rail," Minimum Glass Type "A," with Hi -Rise Sill)
Site Specific Pressure = +55.9 PSF, -60.7 PSF
+70.0 > +55.9, -80.0 > -60.7
B ES Windows, Series 2000 12050A1um. Horizontal Sliding Window - L.M.I., 74" x 63" high.
Dade County Product Approval # 09- 1008.06, Expiration 11/6/2013
Approved Wind Pressure = +80.0 PSF, -90.0 PSF (Min. Glass "Al", H.D.Rail , XO)
Site Specific Pressure = +52.5 PSF, -67.4 PSF
+80.0 > +52.5, -90.0 > -67.4
WITH HORIZONTAL ROLLER "13/1" ON EACH SIDE AS INDICATED:
B/1 ES Windows, Series 200012050 Alum. Horizontal Sliding Window - L.M.I. , 53" x 63" high.
Dade County Product Approval # 09- 1008.06, Expiration 11/6/2013
Approved Wind Pressure = +80.0 PSF, -86.6 PSF (Min. Glass "Al", STD Rail, XO)
Site Specific Pressure = +53.7 PSF, -69.9 PSF
+80.0 > +53.7, -86.6 > -69.9
CONNECT "B" TO B/1 " ON EACH SIDE WITH MULLION "13/2" AS INDICATED:
B/2 63" Mullion Span Use MINIMUM E.S. Windows 1"x4" Custom Mullion
Dade County Product Approval #09- 0825.03 Expires 9/16/2014
Opening Width 127 ", Tributary Width 632 ", Mull Length 63" = 82.9 psf allowed > 68.5 psf Required
With Mullion Clips, Min. Anchor Type "B" = 73.4 psf allowed > 68.5 psf Required
C ES Windows, Series 2000/2050 Alum. Horizontal Sliding Window -L. M. 1. , 74" x 505" high.
Dade County Product Approval # 09- 1008.06, Expiration 11/6/2013
Approved Wind Pressure = +80.0 PSF, -90.0 PSF (Min. Glass "Al", STD Rail, XO)
Site Specific Pressure = +53.3 PSF, -58.1 PSF
+80.0 > +53.3, -90.0 > -58.1
O
3 - EAST ELEVATION
LAPP=
80' -0"
�i
N
z
a
0
I
0
X7050 Limits of Work
uvv wives
7.2 FEET
K*1
O O
-1 /4 = I -v 75' -0" Not To Scale
0
D ES Windows, Series 1500 Aluminum Fixed Window - L.M.I. , 29" x 83j" high.
Dade County Product Approval # 08- 0417.06, Expiration 11/6/2013
Approved Wind Pressure = +70.0 PSF, -90.0 PSF (Min. Glass "B ", Min. Anchors B)
Site Specific Pressure = +54.9 PSF, -59.7 PSF
+70.0 > +54.9, -90.0 > -59.7
GANG "D" UNITS WITH MULLION "D/1" AS INDICATED:
D/1 83 7/8" Mullion Span Use MINIMUM E.S. Windows 1"x4" Standard Mullion
Dade County Product Approval #09- 0825.03 Expires 9/16/2014
Opening Width 58 ", Tributary Width 29 ", Mull Length 83 7/8" = 70.2 psf allowed > 59.7 psf Required
With Mullion Clips, Min. Anchor Type "A" = 65.4 psf allowed > 59.7 psf Required
F ES Windows, Series 1500 Aluminum Fixed Window - L.M.I. , 53" x 14$" high.
Dade County Product Approval # 08- 0417.06, Expiration 11/6/2013
Approved Wind Pressure = +70.0 PSF, -70.0 PSF (Min. Glass "A ", Min. Anchors A)
Site Specific Pressure = +56.8 PSF, -61.6 PSF
+70.0 > +56.8, -70.0 > -61.6
G ES Windows, Series 4000 Aluminum Sliding Glass Door - L.M.I. , 72" x 80" high.
Dade County Product Approval # 09- 0210.07, Expiration 3/18/2014
Approved Wind Pressure = +70.0 PSF, -80.0 PSF (Min. Glass "A", NO Reinf., XO)
Site Specific Pressure = +54.3 PSF, -59.1 PSF
+70.0 > +54.3, -80.0 > -59.1
H ES Windows, Series 4000 Aluminum Sliding Glass Door - L.M.I. , 1422" x 80" high.
Dade County Product Approval # 09- 0210.07, Expiration 3/18/2014
Approved Wind Pressure = +70.0 PSF, -80.0 PSF (Min. Glass "A ", HEAVY Reinf., OXO)
Site Specific Pressure = +53.3 PSF, -68.9 PSF
+70.0 > +53.3, -80.0 > -68.9
J ES Windows, Series 3000 Alum Outswing French Doors w /wo Sidelites -L. M.1. , 352 x 79j" high.
Dade County Product Approval # 09- 0825.04, Expiration 9/16/2014
Approved Wind Pressure = +70.0 PSF, -80.0 PSF (Min. Glass "A ", X)
Site Specific Pressure = +54.3 PSF, -59.2 PSF
+70.0 > +54.3, -80.0 > -59.2
ND ZON
7.2 FEI
0
4- COURTYARD
0
O
5- COURTYARD
C
Q
r�
a
QC
QC
zt
7.2 FEET ,
0
91
GROUND LEVEL
LOCATION PLAN
1/8" = 1' -0„
H
#662 1 661 1
UNIT LOCATION PLAN
Scale: Approx. 1/16 " =1' -0"
IF--]
Le
I= -F
ABOVE ABOVE ABOVE
-lam
SECOND LEVEL
LOFT AREA
U
Q
C0
Courtya nd
s
c
#7050
(See Location Plans) +
L
Courtyard
ag2t -F
Below
1
SECOND LEVEL
LOCATION PLAN
1Z8" = 1' -0"
0