14-998-010NOTE: THE DETAILS ON THIS SHEET ,ARE CONSIDERED T"rFIC,AL AND AIRE NOT NECESSARIL TI CALLED OUT ON PLANS NOTE: ALL RATED PENETRATION DETAILS ON THIS SHT. ARE TO COMPLY WITH UNITED STATES GYPSUM COMPANY DETAILS FOR HOSPITAL AND INSTITUTIONAL- CON37MCTION. - - - - - HANDBOOK DATED FEBRUARY 115% REVISED AUGUST Met EQUIVALENT DETAIL NUMBERS ARE SHOWN WHERE APPLICABLE - - - - - - - - FILL VOIDS WITH SAFING RUNNER TRACK AT VERTICAL JOINTS - AND FIRE CODE COMPOUND __ �'_ _- - FILL VOIDS WITH SAFING FA�LLL VOIDS SS SPRAY ON — FIREPROOFING : ' AND FIRE CODE COMPOUND RUNNER FASTEN T O.C. SECTION - VERTICAL JT. AT BEAM STEEL BEAM FAST 1' RUNNER EN OC. fUrlEF2 FASTDT T-O.C. RDOF/FLOOR DECK GA C2ONNTCANGLE STEEL JOIST 20 ROOF/FLOOR DECK ROORFLOOR DECK FILL VOIDS WITH SAFING - AND FIRE CODE COMPOUND - - - - - STEEL CLIP 'L' - p STAND-OFF v CEILING (TYPJ — _q p— q jj�7- CAULK 6 MIN FIREPROOFING �- 1/2' FIRECODE G GYPSUM BOARD (YPJ Q E SPRAY FIREPROOFING .. X SPRAYED FIREPROOFING p I SPRAYED FIREPROOFING C -H METAL STUDS 6 24' O.C. (TYP.) "v n TYP. SECTION t Lw _ �; CAVITY FULLY PACKED _ — I III WITH SAFING RUNNER TRACK AT VERTICAL JOINTS' ' 1- I NOTE: BOX IN WITH —GYP. AND METAL STUDS SEALANT BD. C •> FIN. FLR I, 20 GA. Z -CLIP 2' I i — _ I — _ 1 I WHEN STEEL JOIST CONDITION FASTEN GYP. BD. FULL HT. , .. O.C. FASTEN BEFORE , SPRAYING 2'x2'x20 GA. GALV. ANGLE PER FIRE TEST :: �.': • ; .:•' ': J �,• RUNNER FASTEN TO CLIPS RETAINER FASTEN TO -- -- . DECK T O.C. I, ONE OR TWO HOUR = ABUT TIGHTLY TO FPFG :. CONT. ANGLE RETAINER 2' TO 4' PARTITION e• ? STEEL JOIST CANNOT BE I I= SCREW TO STUDS A PART OF THE RATED SEPARATION. -- I OR 2 LAYER GYP. BD. EACH SIDE - AS REQ'D. ONE TWO HOUR' ONE OR TWO HOUR PARTITION TWO - HOUR RATED SHAFT WALLS PARTITION SPRAY FIREPROOFING MUST HAVE 2 -HOUR THICKNESS OR GREATER f SAFE AS REQUIRED F 3 EQUIV: TO SKETCH • 109, USG, HANDBOOK EQUIV: TO SKETCH " 110, USG, HANDBOOK EQUIV: TO SKETCH M 101, USG, HANDBOOK j SMOKE AND RATED PARTITION ADJACENT TO BEAM N.T.S. C2)5HAFT WALLS DETAIL N.T.S. 3 RATED PARTION UNDER BEAM N.T.S. SMOKE d RATED PARTITTION ADJACENT TO BEAM N•TS• SMOKE 8 RATED PARTITTION ADJACENT TO BEAM Nrs. (STRUCTURALLY BOXED IN) SPRAY ON DECK HR RATED FIRE PROOFI MEMBRANE NEW 5/8' TYPE 'X' ROOF/FLOOR DECK NEW STUD EXTENSION a p q p a REMOVE EXIST. ' ITT .• —p —7•11 -- q p' •'q DRYWALL q 1"1 I JAI I p q p. p q ROOF/FLOOR DECK RATED CEILING .: q p. . q p r NOTE: DRYWALL JOINTS �— ALL DRYWALL GYP. BD. ONE . C:: I I I ° STAGGERED AT OPPOSITE WALL 5/8' TYPE 'X' METAL STUDS FILL VOIDS WITH SAFING MAX. I I I I q p q p ' SIDES BY MIN. 12' AND FIRE CODE COMPOUND I. I' J q p p ' EXISTING WALL—J' ALL REMOVE EXIST. STEEL JOIST .:I I I I '- q p p HEAD TRACK STUDS STEEL BEAM t;. ; I I I ( I f ABUT TIGHTLY TO FPFG 1 EXTEND EXISTING WALL 2 HR WALL THRU I HR CLG, ASS'Y. 20 GA. Z -CLIP I: " RUNNERS I I I I TO DECK FOR I HR WALL (SHAFT WALL SIMILER) 2' O.C. MAX 6' GYP. BD. L 20 GA Z -CLIPS 2 OG. I; FASTEN BEFORE SPRAY F ' ;1 EXTEND ALL LAYERS OF DECK FASTEN BEFORE I �` SPRAY CANTILEVER I- — — — — — — — — — I I• GYP. BD. TO DECK AND SAFING .. I: NOTE: BOARD MUST I I I I RUNNER FASTEN TO CLIPS I• F, ! SEAL AT FACE LAYER I; ": �'I k : • � SPAN MIN. 2 STUDS I I I I BEFORE CANTILEVER f_ � :•:J I -- .� WITH ACOUSTICAL SEALANT. IN I HR RATED 2 PER STUD ABUT TIGHTLY f. ' i EXTRA WIDE WALL SPACE f TO FPFCs I: ABUT GYP. BD. TIGHT I ' I HR RATED RUNNER FASTEN - : ; :.i TO CLIPS .• ;:� TO FIREPROOFING I " MEMBRANE r:: I I OR 2 LAYERS I� FILL WITH ENTIRE FING VOID ALL DRYWALL 'X' GYP. BD. EACH 5/8' TYPE SIDE - AS REQ'D. RATED WALL SAFE AS REQ'D. FURRING RATED CHASE WALL THRU I HR. CLG ASS'Y. FURRED WALL RATED PARTITION UNDER BEAM RATED PARTITION UNDER JOIST EQUIV: TO SKETCH • 109, USG, HANDBOOK EQUIV: TO SKETCH • 114, USG, HANDBOOK TYPICAL RATED PARTITION DETAIL UNDER BEAM AND /OR UNDER JOIST -j RATED WALL PERPENDICULAR TO BEAM N.TS. S TYPICAL HEAD OF PARTITION N.T.S. �(BTT YPICAL HEAD OF PARTITION 10 PARTITION PENETRATION DETAIL OF N. TS. ONE HOOUR RATED MEMBRANE N.TS. —I1­ — — — FLOOR OR ROOF SLAB ASSEMBLY CONC. SLAB ON METAL DECK ! 3' 1 I 1 1 GREATER THAN 2' —.— .: �..—. ° _ — — LESS THAN 6' ` (• o ' MAX. 2' FLOOR OR ROOF SLAB ASSEMBLY FILL VOIDS. SEE DETAIL 06 _ 1 :. 1 GYPSUM WALLBOARD BLOCK !1/1' X 1'J CUT GYPSUM PANELS TO p q p ' : I SPACED IS' O.C. VERT. AT EACH CHANNEL FIT DECK C,0WIG. p ' — - I/4' NOM. GAP FILL WITH ACOUST. SEALANT TIGHTLY FILL VOIDS AT METAL DECK WITH SAFING MATERIAL — _ X— a 1Tr'i� a� — —°— p ' 1 1.1 ► ► 1 1 1 11 q ' 1 d )• t 11 p ' - - � '.. - 1 1 WIRE TIE LATH, BLOCK I - . • jI AND CHANNEL TOGETHER r RUNNERS - ATTACH WITH 4 */CF DEN :..I ' i 2 -0 O.C. RUNNERS - ATTACH WITH -q 1 CEILING ANCHORS 2'-0' O.C. - 3.40 D M LATH (GALV.) CEILING FIN. FLOOR OR ROOF - A" •: II 1 GYPSUM PLASTER I FACE TO BE SEALED WITH 1 CONTINUOUS STEEL STUDS DRYWALL SEALANT, OR TAPE (16' / 24' O.C.) CONTINUOUS STEEL STUDS AND JOINT COMPOUND !I6' / 24' O.C-) SAFING AS REQUIRED TIGHTLY FILL VOIDS AT METAL ' 1 DECK WITH SAFNG INSULATION 1 - 1/2' CRC IV O.C. CEILING ACOUSTICAL SEALANT ACOUSTICAL SEALANT RATED CON(. BLOCK SEE N • , `. II 1 -: ��.: :� RUNNERS - ATTACH WITH ANCHORS T -0' O.C. PLAN FOR SIZE AND RATING 1 " :. i SHAFT SIDE FIN. FLOOR A�NCNHORS 2A0' O.C. FIN. FLOOR NOTE: THE BLOCK MANUFACTURER 1 FINISH SIDE I "• III TWO HOUR WALL ONE HOUR WALL v • q STATING THE APPROVED EQUIVALENT O C O A THICKNESS AS REQUIRED BY THE SECURE I - IR' CRC TO ANGLE FIN. FLOOR STANDARD BUILDING CODE. B' I -1/2' X I -1/2' X 18 GA CONT. ANGLE • I FLOOR AND STRUCTURE ABOVE. FLOOR _:' � •' FASTEN AT 24' O.G. SECTION SECTION N.T.S. N.T.S. 1 NOTES: TEST REF: TEST REF: WALL SECTION I. JOINTS MAY BE OPPOSITE IF SAFENG IS USED IN CAVITY. T- 3362 -OSU T- 3362 -0511 N.T.S. WALL SECTION !MAXIMUM HEIGHT IS' -07 REF: CEG 8 -11 -83 CEG 5 -S -84 T- 1114 -OSU GAWP -1200 T- 1114 -0SU N.T.S. 2. JOINTS IN FINISH LAYER TO RECEIVE TAPE AND JOINT COMPOUND GA-WP-1200 SMOKE 6 ONE -HOUR PARTITION DETAIL N.T.S. >> 8 ONE -HOUR PARTITION DETAIL N.T.S. �2)SMOKE 13 TYPICAL RATED BLOCK WALL FIRE OR SMOKE N.TS. TYPICAL TWO HOUR PLASTER SHAFTWALL DETAIL N.T.S. HORIZONTAL JOINT REQUIREMENTS �rj (PERPENDICULAR TO OEM (PERPENDICULAR TO OEM (MAX1`121HElr�rrle' -&) ABOVE SUSPENDED CEILINGS N.r.s. STRUCTURE ABOVE ROOF OR FLOOR DECK PIPING AND /OR CONDUIT � rjO�ti 1D� ��Y OF SCHEDULE CEILING I PIPING G�� � gU� SOUTH rLfi �L�� 1pllVG p 'X' O`4`1G���0 EP 5/8' TYPE GYPSUM ,F� 1, S "' rRUCTU 5/8' GYPSUM BOARD WALLBOARD AT RATED A/C DUCT �tO¢ r1p0 SECtI CEILING OVER 3 5/8' METAL STUDS PARTITIONS HAZARDOUS ROOM FUNCTIONS ELECTRICA CL WHICH DO NOT OTHERWISE REQUIRE A RATED ENCLOSURE F.EJF. HOSE i + ARE STILL REQUIRED TO BE SEPARATED BY A SMOKE CABINET/ ELECTRICAL/ CLEA (LEA CLEAFQ RESISTANT PARTITION TELEPHONE PANELS CONSTRUCTEDTO THE DECK A/C DUCT ABOVE. RECESSED LIGH FI TURE SMOKE RESISTANT WALLS MUST CEILING COUNTY BE CONTINUOUS FROM FLOOR I NIAiVII -DARE TO DECK ABOVE UNLESS THE FIRE DEPARTMENT CEILINGIS A FIRE RESISTANCE RATED FLOOR/CEILING OR I ROOM CORRIDOR ROOM ROONCEILINGASSEMBLY. 0 I cn FLOOR 'f. NOTE: SECTION REFER TO 1 /8' FLOOR PLAN FOR EXACT LOCATIONS N.T.S. F. E. CABINET SMOKE RESISTANT WALLS AND HAZARDOUS N.T.S. FIRE EXTINGUISHER CABINET /ELECTRICAL / N.T`. Q 1S EQUIPMENT CLEARANCE jg N.T.S. EFNIN STANDARDBUILDNr .CODE4MI.5J FUNCTION SEPARATION WALLS (As D ED TELEPHONE /PANELS SECTION DETAIL N.T.S. N.TS. xM► V Y �2 Revisions: z Oa A �O wx %" �I L z Lia 0 �V wz z< z' ~ T,, H a . o 1.4 x O C Q +' r O lIs LLI ,� 1. w cn j z~ z O r� 1- 4 Vz 154 W %ii z LLA a PERMIT SET 08/01/14 DRAWN: GAC CHECKM LEN DATE 01 -29 -14 SCALE AS SHOWN E , :tom 1- '•;� -� 1 I EGA p. Sheet No. I JOB # 201426 I