14-998-008NOTE: THE DETAILS ON THIS SHEET ARE CONSIDERED TYPICAL AND /ARE NOT NECESS,4RILY CALLED OUT ON PLANS HNOTE: ALL RATED ANDBOOK DATED FEBRUARY 991, REVISED AUGUST SS1..EEQUI COMPLY ENT DETAIL NUMBERS ARE SHOWN WHERE APPLICABLE FOR HOSPITAL AND INSTITUTIONAL CONSTRUCTION. ARE ACGTEP%gL aTE"1S Ilk SMALL OPENINGS MAY BE PATCHED USING JOINT == COMPOUND, CAULK MIN. 20 GA. GALV. OR BLOW -OUT PATCHES. I I I W SE�VE. SECURE N- j CUT -OUT MAX. 6'x6' T SECT. I--- STUDS - - - TYP. SECT. p PE O UP TO I - RUNNER CHANNELS, TYPICAL PIPE OR CONDUIT.' - i. i i STUD TYPICAL SEAL • _ I r - - -- 1 I GWB PATCH BUTTER BACKSIDE t I I I 1 • ' • 1 SURFACE. DO NOT REMOVE JOINT SAFING FOR PIPING NOT LARGE OPENINGS REQUIRE AGLOW -OUT PATCH S - -_ - -� _ S I GWB PATCH (BUTTER BACKSIDE SURFACE) g S COMPOUND DISPLACED ATE SUBJECT TO COt D"ATIOh l - - ( • I I I :o OR FOAMGLAS IU SLEr- j OR WALL REPAIR I N ^�� I PARTIAL ELEVATION OR F15ERGLA55 -WI I - MIN. 2 'S' SCREWS PER SECTION, MIN. �- UNSLEEVED FROPRIATORY SYSTE`l FOR • 1 I `� I I 3' FROM OPENING AND EDGE OF PATCH FOR PIPES AND CONDUIT PIPING SUBJECT_T:" FOR PIPES AND CONDUIT I 1 `W�� TYPE 'G' SCREWS MIN. 2 PER MAIN WALL SURFACE CONDENSATION E 3' NOT SUBJECT TO MOVEMENT SUBJECT TO VIBRATION 1 L___ ANNULAR OPENING IN PARTITION AROUND SECTION. LEAVE EXPOSED. �- --� I • N -- - _ I • I PIPE OR CONDUIT GREATER THAN 3' DIA. 6' MIN. 3' 6' MIN. 1 • 1 OR CONDENSATION. INSULATION WHERE EXPANSION, CONTRACTION, 1 I APPLICABLE AND /OR CONDENSATION. SMOKE RESISTANT WALLS i i i 1 CUT GYPSUM BOARD TIGHT TO PIPE S S• ANNULAR OPENING IN PARTITION i i UNSLEEVED WIRE 34 N N AROUND PIPE OR CONDUIT i N PATCH UP TO A 2' BUNDLE SECURE MI I DO NOT MUD AND TAPE EDGES 3' DIA. OR LESS. 1 SCREW Li H HOLES HOLES OVER 3' DIA HOLES UP TO 3' DIA. UP TO 3' DIA. I I I N' ACOUSTIC CAULK UP TO 1!1 OPENINGS MAY BE FILLED FULL DEPTH OF -- -- 1 � DRYWALL WITH ACOUSTICAL SEALANT. STRIKE OFF AT RUNNER TRACK SECTION Q FACE OF DRYWALL. DO NOT SPREAD BEYOND OPENING. I!1' MAX (SAFE ALTERNATIVELY, A PROPRIETARY SYSTEM MAY BE USED. BLOW -OUT PATCH PARTIAL ELEVATION /2' MAXIMUM UP TO 1/4' OPENING IF OVER 1/2') S MAY BE FILLED WITH JOINT BLOW -OUT PATCH COMPOUND. ONLY I LAYER ON EACH SIDE OF WALL REQUIRED FOR RUNNER TRACK SECTION TYPICAL SEAL ONLY I LAYER ON EACH SIDE OF WALL REQUIRED FOR 1 OR 2 HOUR WALLS. CONDUIT FOR UP TO 1/8' OPENINGS DO NOT REQUIRE ANY TREATMENT. 1 OR 2 HOUR WALLS. BLOW -OUT PATCH IS NOT ACCEPTABLE ON WALLS RATED BUNDLED WIRES BLOW -OUT PATCH IS NOT ACCEPTABLE ON WALLS RATED AT 3 OR 4 HOURS. OVER 2 INCHES LARGER THAN I/2' OPENINGS REQUIRE AGLOW -OUT PATCH AT 3 OR 4 HOURS. NOTES: TAPE AND FINISH (SEE DETAIL 2 4 3 THIS SHEET). SOME LOCAL JURISDICTIONS I. BUTTER ENTIRE BACK SIDE OF PATCH WITH JOINT COMPOUND. WIRE PENETRATIONS FIRE OR SMOKE WALL PENETRATIONS DO NOT ALLOW THE BLOW -OUT PATCH. NOTES: 2 LEAVE ALL SCREWS EXPOSED. SECTION . 1. BUTTER ENTIRE BACK SIDE OF PATCH WITH JOINT COMPOUND. (SLEEVES SHALL BE SECURED PLASTER DRYWALL, CONCRETE, OR MASONRY 2. LEAVE ALL SCREWS EXPOSED. EQUIVALENT TO USG WALL PENETRATIONS. FIRE TEST IN THE WALL TO PREVENT TYPICAL SEAL AS FOLLOWS: 30 -MIN., 1 -HR. 4 2 -HR. RATED WALLS (FIRE. FIRE 4 SMOKE) FILE T2 -1313 PENETRATION DETAIL 'F' (11 -1 -84) MOVEMENT) EQUIVALENT TO USG WALL PENETRATIONS. FIRE TEST LESS THAN I/2' =ACOUSTIC CAULK OR DRYWALL 3- AND 4 -HR WALLS REQUIRE THE USE OF A PROPRIETARY SYSTEM FILE T2 -1313 PENETRATION DETAIL 'F' (I1 -1 -84) FLUSH PATCH - SMALL JOINT COMPOUND (NO TAPE) MORE THAN I/2' BLOW-OUT P IARY SYSTEM. 1 TYPICAL DRYWALL SEALING DETAIL AT TYPICAL DRYWALL PATCH DETAIL AT TYPICAL DRYWALL PATCH DETAIL AT TYPICAL CONDUITS (SLEEVED AND /OR RATED PARTITION PENETRATION PENETRATIONS LARGER THAN 3" DIAMETER N.TS. 3 PENETRATIONS LESS THAN 3' diameter N.TS. FLUSH PATCH DETAIL "TS' S UNSLEEVED), AND WIRE PENETRATIONS DETAIL N'TS' >R' C.M.U. OR CONCRETE / BOTTOM OF STRUCTURE PROPRIATORY SYSTEM OR ®� COVER PLATE A/C DUCT THRU FIRE UL. TESTED NONSHRINK \ DRILLED HOLE IN DRYWALL PARTITION GROUT - FILL OPENING COMPLETELY - - - - - - J I MIN. 2'x2'xlO GA. ANGLE ATTACHED I METAL STUD FRAMING AROUND TO ALL FOUR SIDES W /'10 SHEET METAL O O O I I SECTION 1 -I DUCT 8 SCREWS MINIMUM ATTACHED TO SIDE OR I NOT TO WALL r_ AS REQUIRED FOR CLOSURE IS/8' MAX. 1%. MAX j- t----- - - - --1 I z A SAFING INSULATION DAMPER PROVIDE CELL CLOSURE I I TYP. SECT. ( I E I - DRILLED HOLE IN DRYWALL • — • • — • (SEE MECHANICAL DRAWINGS) DUCT DUCT OF NON -L IN C.M.U. S WALLS ( ----- - - -j -I --- - - - - -- I Wrl I Ra O O O O O O I I APPROX. EQUAL I I I BUTT INSULATION TO ANGLE DO NOT CONCRETE MASONRY UNITS OR SOLID CONCRETE WALLS I I SECTION 2 -2 I I INSULATE DUCT THRU WALL IL I r---- - - - - -I - - - - -- I x I I I A I I PROVIDE OPENING BETWEEN WALL AND 48' MAX - 2 2 3/8' OR IR' THREADED ROD AS PER MANUFACTURER EVE METAL STUDS BEHIND GYP. BD. RECOMMENDATION GYPSUM PLASTER AND METAL RUNNERS I RATED DRYWALL CLG. 24' AX METAL LATH ON METAL PER TEST ASSEMBLY I STUDS PACK WITH THERMAFIVER MULTIPLE CONDUIT / PIPE PENETRATIONS SAFING AT MANUFACTURED NUT AND COVER PLATE CEILING LINE DENSITY WITH NO VOIDS AS REQUIRED FOR CLOSURE OR GAPS CHANNEL TO SUPPORT USE INTERMEDIATE STUD NON -RATED CEILING SERVICES WHEN SPACING 15 GREATER 2. ALL PIPES, CONDUITS AND DUCTS AT ALL THAN 24' DUE TO LARGE DUCT PLASTER AND METAL LATH NOTE: Q OF METAL STUDS (BEYOND) I. SEE MECHANICAL DRAWINGS FOR DAMPER DETAILS. FIRE WALL PENETRATIONS SHALL BE DONE AT 90 DEGREES ON BOTH SIDES. GYPSUM PLASTER, METAL LATH AND METAL STUD PARTITIONS (o PIPE PENETRATION DETAIL N.T.S. PIPE INSULATION (IF APPLICABLE) DOES NOT CONTINUE THRU SLAB OPENING PACK IN FULL WITH THERMA FIBER FIRE SAFING INSULAT CAST IRON PIPE I' OF NON SHRINK GROUT REF: UL SYSTEM No. WL 1065 MULTIPLE PIPE PENETRATION DETAIL MIN. 2 x 2 x 10 GAGE ANGLE ATTACHED TO ALL FOUR SIDES OF DAMPER SLEEVE W/ 010 SHEET METAL SCREWS MIN. 2 PER SIDE OR 1 EVERY 8 INCHES. ATTACH TO SLEEVE NOT TO WALL. DUCT BUTT INSULATION TO ANGLE. DO NOT INSULATE DUCT THRU WALL CAULK UNDERSIDE SMOKE TIGHT (TYP.) 114' MAX NOTES: I. PROVIDE SUPPORT AT FLOOR PENETRATIONS FOR SAFING WHEN PIPES ARE OVER 2' WIDE. EQUIP. TO USG PILOT FIRE TEST: FLOOR PLAN - CONDUIT FIRE STOPPING - REPORT 23396 FILE 1-4651( 5 -26 -16 ) 11 PIPE PENETRATION THRU SLAB '♦ ♦ • '• ♦ ' EXTERIOR Q' .. a .. ♦.. .d ♦ . ♦. FIRE BARRIER 4 ♦ • a ♦ ° •A 4... ' ♦ . PUTTY . e d ` ♦' :1 ♦ . • ♦. PIPE DRYWAI MTL. FUF STRIPS INTERIO REF: U.L. SYSTEM No. 84 1(o PIPE PENETRATION THRU MASONRY NOTES: I. SEE MECHANICAL DRAWINGS FOR DAMPER DETAILS. 2. MOTOR SHALL BE MOUNTED ON DAMPER SLEEVE AND TO BE MONITORED TO FIRE ALARM SYSTEM. 3. ALL PIPES, CONDUITS, AND DUCTS AT ALL SMOKE/FIRE WALL PENETRATIONS SHALL BE DONE a SO DEGREES ON BOTH SIDES. EQUIV. TO SKETCH 0 305, 306, USG, HANDBOOK N.TS. 8 PENETRATION DETAIL IN RATED CEILING COMBINATION SMOKE/FIRE METAL STUDS BEHIND I �I DAMPER GYPSUM BOARD I�I I r 4 A/C DIFFUSER THERMANBER SAFING MATERIAL 4. 2 HOR RING PACKED TIGHTLY INN _ WALL AND DAMPER SLEEVE �.� ,:..'••.:' � • • : • I- - - - --� MIN • ♦ , • IF1 \ RECOMMENDATION 5/8' TYPE 'X' DRYWALL PATCH • • :♦ I SMOKE/FIRE PARTITION 2 a ' • • FIF METAL RUNNERS TOP AND BOTTOM A4- a• .d' - .. SEAL SMOKE TIGHT . . ♦ 0 MOLDABLE PUTTY (TYP.) EACH SIDE BACK SIDE OF DRYWALL PATCH. - ♦. :♦. NOTE: SEAL SMOKE TIGHT AT ALL - , INSTALLED FLUSH TO EDGES (TYP.). BLK. W A. BOTH SURFACES OF I ED ,: •: •: :•. �•.:•.. ARE .4. A. :A- WAL INSULATION THIC104ESS 2 3 d '. AD. ffi 'r . ' . ' ' THE AS SPECIFIED. EXTEND ' . • •♦ A. METAL PIPE / CONDUIT REF: U.L. SYSTEM No. 84 1(o PIPE PENETRATION THRU MASONRY NOTES: I. SEE MECHANICAL DRAWINGS FOR DAMPER DETAILS. 2. MOTOR SHALL BE MOUNTED ON DAMPER SLEEVE AND TO BE MONITORED TO FIRE ALARM SYSTEM. 3. ALL PIPES, CONDUITS, AND DUCTS AT ALL SMOKE/FIRE WALL PENETRATIONS SHALL BE DONE a SO DEGREES ON BOTH SIDES. EQUIV. TO SKETCH 0 305, 306, USG, HANDBOOK N.TS. 8 PENETRATION DETAIL IN RATED CEILING COMBINATION SMOKE/FIRE METAL STUDS BEHIND I �I DAMPER GYPSUM BOARD I�I I r 4 A/C DIFFUSER THERMANBER SAFING MATERIAL 4:v 2 HOR PROVIDE OPENING BETWEEN PACKED TIGHTLY INN _ WALL AND DAMPER SLEEVE �.� ,:..'••.:' � • • : • I- - - - --� AS PER MANUFACTURER IF1 \ RECOMMENDATION 5/8' TYPE 'X' DRYWALL PATCH I I SMOKE/FIRE PARTITION 2 ..• .. :.. • .♦ . ' � PACK METAL RUNNERS TOP AND BOTTOM - .. SEAL SMOKE TIGHT APPLY DRYWALL COMPOUND TO MOLDABLE PUTTY (TYP.) EACH SIDE BACK SIDE OF DRYWALL PATCH. NOTE: SEAL SMOKE TIGHT AT ALL INSTALLED FLUSH TO EDGES (TYP.). N.T.S. [ 12 ) WALL DIFFUSER DETAIL N.TS. ( 13 N.TS. I Cj) TYPICAL DUCT PENETRATION DETAIL BOTTOM OF STRUCTURAL DECK CAULK SMOKE TIGHT (TYP.) EACH SIDE SMOKE/FIRE RATED PARTITION MAX. (SEE WALL TYPES) BLOW UP PATCH TO BE LJ ONE LAYER 5/8' TYPE 'X' GYPSUM WALLBOARD EACH SIDE (SEE SIMILAR DETAIL THIS SHEET) MULTIPLE CONDUIT PENETRATING FIRE/ SMOKE RATED PARTITIO METAL HANGERS (TYP. APPLY DRYWALL COMPOUND TO BACK SIDE OF DRYWALL PATCH EACH SIDE SEAL SMOKE TIGHT AT ALL EDGES (TYP. z_ E NITS. [ 10) TYPICAL INSULATED DUCT PENETRATION DETAIL N.T.S. BOTTOM OF STRUCTURAL DECK SPA SMOK TG (TYP IDES) FPIUUT BARRf DRYWALL OVER METAL FURRING STRIPS 1 MULTIPLE PIPE PENETRATION DETAIL N.T.S. 15 PIPE PENETRATION THRU MASONRY N.T.S. d . UL. SYSTEM NO. W -L -1054 A 3 3 lA OPWA 61266 METAL F RATING - I HOUR AND 2 HOUR 6' 644' 4:v 2 HOR Im' 121/4@ INN T RATING - 0 HOUR NOTL• �.� ,:..'••.:' � • • : • NOT TO 6» 34' SEAL IF1 FIRE RATED CONCRETE . ` '• n 111 ft t l l :�:�::::'r::'r:::8r:•r:• }y: :•:I I I I I I I I 2 ..• .. :.. • .♦ . ' � SPA SMOK TG (TYP IDES) FPIUUT BARRf DRYWALL OVER METAL FURRING STRIPS PIPE SMOKE (TYP.) IN FILL WITH APING INSUL. FOR GONG, ALL, FILL IATELY ADJ. AS WITH CONIC. THEN APPLY THIS DETAIL INTERIOR MODIFICATIONS ONLY (ANY EXTERIOR MODIFICATION MAY REQUIRE A DO,'.FD APPEARANCE) NOTE: ALL PIPES, CONDUITS, DUCTS AT ALL SMOKE / FIRE WALL PENETRATIONS SHALL BE DONE AT W DEGREES ON BOTH SIDES EQUIP. TO USG WALL PENETRATIONS FIRE TEST FILE T2 -1313 EQUIP. TO USG WALL PENETRATIONS FIRE TEST FILE T2 -1313 PENETRATION DETAIL ' F ' ( 11 -1 -84 ) PENETRATION DETAIL ' F ' ( 11 -1 -84) REF: UL. SYSTEM No. 83 - (ULTIPLE PIPE PENETRATION THRU BOTTOM OF STRUCTURAL DECK BOTTOM OF STRJCTURAL DECK PIPE HANGERS (TYP. SEAL SMOKE TIGHT AT BOTH SIDES) N PIPE HANGERS (TYP. 1' -0' 1 (TYP.) EACH SIDE AT BOTH SIDES) MAX. I �p PIPE 1 I PIPE SMOKE OR FIRE RATED PARTITION DRYWALL TYPE 'X' ON -1 I FOR SEALING AND /OR METAL STUDS I I PATCHING OF OPENING I I SEE DETAIL NO. 8 THIS SHT. ULK DOTED LINE INDICATE CK IN FULL WITH PATCH CONDITION E SAFING INSUL. FOR CONC. BLK NOTE: L, FILL IMMEDIATELY I. ALL PIPES AND CONDUIT AT SMOKE/FIRE WALL PENETRATIONS SHALL AREAS WITH CONC, BE DONE AT W DEGREES ON BOTH SIDES. J APPLY THIS DETAIL. N.T.S. 11) TYPICAL PIPE SUSPENSION DETAIL AT RATED PARTITION N.T.S. 1 MULTIPLE PIPE PENETRATION DETAIL N.T.S. 15 PIPE PENETRATION THRU MASONRY N.T.S. d . UL. SYSTEM NO. W -L -1054 A 3 3 lA OPWA 61266 METAL F RATING - I HOUR AND 2 HOUR 6' 644' 4:v 2 HOR Im' 121/4@ 1' T RATING - 0 HOUR NOTL• �.� ,:..'••.:' � • • : • NOT TO 6» 34' SEAL FIRE RATED CONCRETE . ` '• n TIGHT 2 ..• .. :.. • .♦ . ' � PACK OR CONCRETE BLOCK WALL - .. SEAL SMOKE TIGHT FIRE S MOLDABLE PUTTY (TYP.) EACH SIDE •• *. a ':•, •• NOTE: INSTALLED FLUSH TO '. ! d'. BLK. W A. BOTH SURFACES OF I ED ,: •: •: :•. �•.:•.. ARE PIPE SMOKE (TYP.) IN FILL WITH APING INSUL. FOR GONG, ALL, FILL IATELY ADJ. AS WITH CONIC. THEN APPLY THIS DETAIL INTERIOR MODIFICATIONS ONLY (ANY EXTERIOR MODIFICATION MAY REQUIRE A DO,'.FD APPEARANCE) NOTE: ALL PIPES, CONDUITS, DUCTS AT ALL SMOKE / FIRE WALL PENETRATIONS SHALL BE DONE AT W DEGREES ON BOTH SIDES EQUIP. TO USG WALL PENETRATIONS FIRE TEST FILE T2 -1313 EQUIP. TO USG WALL PENETRATIONS FIRE TEST FILE T2 -1313 PENETRATION DETAIL ' F ' ( 11 -1 -84 ) PENETRATION DETAIL ' F ' ( 11 -1 -84) REF: UL. SYSTEM No. 83 - (ULTIPLE PIPE PENETRATION THRU BOTTOM OF STRUCTURAL DECK BOTTOM OF STRJCTURAL DECK PIPE HANGERS (TYP. SEAL SMOKE TIGHT AT BOTH SIDES) N PIPE HANGERS (TYP. 1' -0' 1 (TYP.) EACH SIDE AT BOTH SIDES) MAX. I �p PIPE 1 I PIPE SMOKE OR FIRE RATED PARTITION DRYWALL TYPE 'X' ON -1 I FOR SEALING AND /OR METAL STUDS I I PATCHING OF OPENING I I SEE DETAIL NO. 8 THIS SHT. ULK DOTED LINE INDICATE CK IN FULL WITH PATCH CONDITION E SAFING INSUL. FOR CONC. BLK NOTE: L, FILL IMMEDIATELY I. ALL PIPES AND CONDUIT AT SMOKE/FIRE WALL PENETRATIONS SHALL AREAS WITH CONC, BE DONE AT W DEGREES ON BOTH SIDES. J APPLY THIS DETAIL. N.T.S. 11) TYPICAL PIPE SUSPENSION DETAIL AT RATED PARTITION N.T.S. 1 MULTIPLE PIPE PENETRATION DETAIL N.T.S. 15 PIPE PENETRATION THRU MASONRY N.T.S. '111' UL. SYSTEM NO. W -L -1054 A 3 3 lA OPWA 61266 THIQOM F RATING - I HOUR AND 2 HOUR 6' 644' I`:' 2 HOR Im' 121/4@ 1' T RATING - 0 HOUR NOTL• MAJt2MIJM AW LAR 6PAC6 Bi WMN PIPIT AND OP6NMG NOT TO 6» 34' FIRE RATED CONCRETE 2 OR CONCRETE BLOCK WALL 3M FIRE BARRIER SEAL SMOKE TIGHT MOLDABLE PUTTY (TYP.) EACH SIDE INSTALLED FLUSH TO BOTH SURFACES OF FOAM GLASS PIPE INSULATION THIC104ESS 2 3 ffi THE WALL AS SPECIFIED. EXTEND METAL PIPE / CONDUIT 6' BEYOND WALL ON A BOTH SIDES �— AS REQUIRED FOR CLOSURE SECTION A -A CUT OPENING IN WALL L WALL ASSEMBLY - THE I OR 2 HOUR FIRE -RATED GYPSUM W4LL BOARDNSTUD QUALL ASSEMBLY SHALL BE CONSTRUCTED OF TFE 77 WITHIN 1/4' OF FOAM MATER14LS AND N THE MANNER SPECIFIED N THE INDIVIDUAL U300 OR U400 SERIES WALL AND PARTITION DESIGNS N THE UL FIRE GLASS AND SEAL OPENING RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: MIAMI -DADE WITH DR7lUALL MUD A $1>LID$ - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOMINAL Z BY 4 NCH LUMBER SPACED 16 INCHES Or- STEEL STUDS TO BE MIL 2 -14 IR WIDE AND SPACED MAXIMUM 24 NCH ON CENTER WHEN L FIRE DEP'All STEEL STUDS ARE USED AND THE DIAMETER OF OPENING EXCEEDS THE WIDTH OF STUD CAVITY, THE OPENING SHALL BE FRAMED PROVIDE CELL CLOSURE ON ALL SIDES USING LENGTHS OF STEEL STUD INSTALLED BETILEEN THE VERTICAL STUDS AND SCREW-ATTACHED TO THE STEEL OF NON - COMBUSTIBLE STUDS AT EACH END. THE FRAMED OPENING N THE WALL SHALL BE 4 K TO 6 R WIDER AND 4 TO 6 R HIGHER THAN THE DIAMETER OF THE PENETRATING ITEM BUSH THAT, WHEN THE PENETRATING ITEMM IS INSTALLED N THE OPENNG, A 2 TO 3 R CLEARANCE IS MATERIAL IN GMJJ. WALLS PRESENT BETWEEN THE PENETRATING ITEM AD THE FRAMING ON ALL FOUR SIDES. B. GYPSUM BOARD- • 5/6 INCH THICK 4 FT. WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, THICIQNESS, NUMBER OF LAYERS. FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED N THE INDIVIDUAL U300 OR U400 SERIES DESIGN IN THE U_ FIRE RESISTANCE DIRECTORY. MAXIMUM DIAMETER OF OPENING IS 32 -1/4 R FOR STEEL STUD WALLS. MAX DIAM OF UL SYSTEM No202 OPENING IS 14 -I/! IN. FOR WOOD STUD WALLS. NOTE: THE V RATNG OF THE FIRESTOP SYSTEM 15 EG1)AL TO THE FIRE RETNG OF THE WALL ASSEMBLY. ALL PIPES, CONDUITS AND DUCTS AT ALL SMOKE/FIRE WALL 2. THROUGH - PENETRANTS - ONE METALLIC PIPE. CONDUT OT TUBING TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY PENETRATION SHALL BE DONE AT W DEGREES ON BOTH SIDES, WITHIN THE FIRESTOP SYSTEM. AN ANNA-AR SPACE CF MR 0 INTO MAX 2 -1/4 IN. IS RECUIRED WITHIN FIRESTOP SYSTEM PIPE, CONDUIT OR TU3NG TO BE RIGIDLY SUPPORTED ON BOTH SEES OF WALL ASSEMBLY. THE FOLLOWING TYPES AD SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED, A STEEL PIPE_ NOM 30 R DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE B. IRON PIPE NOM 30 IN. DIAL (OR SMALLER) CAST OR DUCTILE IRON PIPE. G fill- NOM 4 K DIAM (OR SMALLEW STEEL ELECTRICAL METALLIC TUBING OR 6 IN. DIAML STEEL CONDUIT. D. ice$ TUBING NOM 6 IN. DIAL (OR SMALLER) TTPE V (OR HEAVIER) COPPER TUBING. E f @ PIPE- NOM 6 R DIAL (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE 3. FILL, VOID OR CAVITY MATERIAL- - SEALA14T MN 5/8 R OR 1 -1/4 R THICIQdESS CF FILL MATERIAL APPLIED WITHIN THE ANNULUS, MA)OW MA) MIJrM MIN" PUTTY '111' PIPE INMB OPWA 61266 THIQOM RATN3 6' 644' I`:' 2 HOR Im' 121/4@ 1' 3 HOW NOTL• MAJt2MIJM AW LAR 6PAC6 Bi WMN PIPIT AND OP6NMG NOT TO 6» 34' EQUIP. TO USCG WALL PENETRATIONS FIRE TEST FILE T2 -1313 RUSH WITH BOTH SURFACES CF WALL FOR I OR 2 M WALLS RESPECTIVLEY. AT THE POINT CONTACT LOCATION B MMIN PIPE AD PENETRATION DETAIL ' F ' ( 11 -1 -84) WALL, A MN VI N DIAL BEAD OF FILL MATERIAL SHALL BE APPLIED AT THE PIPE COVERMCa/WALL NIEFPACE ON BOTH °A1WACE8 OF REF: UL SYSTEM No202 HIILTI CONSTRUCTION CHEMICALS, DIV OF HILTI NC - FS - ONE SEALANT • Bearing the UL Clawricatlon Mark N.T.S. PIPE PENETRATION DETAIL N.T.S. ENETRATION FIRESTOP FOR METAL PIPE 18 19 14 2 HOUR PENETRATION DETAIL N.T.S. N.TS. 20 THROUGH A CONCRETE WALL N.T.S. Revlslons: 0 0 zn_� 0 z 1 0 4 E-,4 A�110-011 1-111 �0 LQ �/ 1 lz-' z w2 0 V wz _z 4 zs; a to ;4 O 0 C r O LAJ W H=�1 z� zA O r� �--' z W C4 z w a PERMIT SET 08/01/14 DRAWL GAG CHECKED: LEN DATE: 01-29 -14 SCALE: AS SHOWN E. .� •� a i (Zvi . 1 d,t O� 8\llc3 . 7 ' •.: .'`.c ED' A'�? Sheet No. A -6 OF 8 Jos # 201426