14-998-007OF
RUCTURE
:NSION
DERSIDE
COUSTICAL
CEILING TILE: SEE
CEILING PLAN AND SPECS
FOR TYPE
FACE OF FINISHED WALL
ACOUSTICAL
CEILING PANEL (SEE
SPECS FOR TYPE)
METAL ANGLE STRIP
FINISH TO MATCH
'1' SYSTEM
SING
SPF
3 -5/8'
MTL. STUDS
a I6' O.C.—
ACOUSTICAL
CEILING TILE
5/8' G111B.
LING
ID
DOORFRAME
NOTE: DO NOT SUPPORT SOFFIT
FROM FIRE RATED PARTITIONS.
AT FIRE PARTITIONS ANCHOR TO
STRUCTURE ABOVE.
LL
r
UNDERSIDE OF
EXISTING STRUCTURE
ACOUSTICAL
CEILING
N
W
Q
SEE INTERIOR
ELEVATION OR
REF. CLG. PLAN\
GIUB.
a
METAL STUDS.
L7
I
CORNER BEAD
LL� ACROSS SOFFIT.
z
LL PAINTED
p 5/8' G.WS
r
0
cp
1 CEILING DETAIL NT5 2 CEILING DETAIL N.T.S. 3 CEILING DETAIL N.T.S. �4) CEILING DETAIL N.T.S. rj CEILING DETAIL N.T.S.
CEILING
AC
R HE
�E
METAL STUCS
SIZE AS SUDS
rFE 'X' GIUB.
c 1l' BUGLE
DRYWALL
EW 18' O.C.
TINUOUS
I INUM
41NER
3' ACROVYN
HIGH IMPACT
VINYL ACRYLIC
EXTRUSION.
INTERIOR PARTITION
3 -5 /a' x 20 ga METAL STUDS
AT 16' O.C. SECURED TOP
AND BOTTOM
5/8' DUROCK
I x 4 WD. BAC
AT 331/2' ABO
FINISH FLOOR
331/2' ABOVE
FINISH FLOOR
(FIELD ADJUST)
8' C.M.U. WALL
5/8' DUROCK—.
1 x 4 WD. P.T. BA
AT 331/2' ABOVE
FINISH FLOOR-
331/2' ABOVE
FINISH FLOOD
(FIELD ADJUST)
NOTE: PROVIDE 1 x 4 WD. P.T. BACKING AT 331/2' ABOVE FINISHED
FLOOR SHALL BE INSTALLED FOR THE ATTACHMENT OF
EACH WALL HUNG PLUMBING FIXTURE
2 x 4 WOOD BACKING
AT TOP OF WALL CABINET
WALL CABINET
INTERIOR PARTITION
3 -5 /a' x 20 ga METAL STUDS
AT 16' O.C.
2 x 4 WOOD BACKING AT
BOTTOM OF WALL CABINET
1/2' GYPSUM
WALLBOARD
NOTE: A MINIMUM 2 x 4 HORIZONTAL WOOD MEMBER
SECURELY FASTENED TO NOT LESS THAN 2 SUCH
STUDS, SHALL BE INSTALLED FOR THE ATTACHMENT
OF EACH WALL CABINET.
i METAL STUDS OR R RRMG a
I I
----- }___ -- BACKING FOR FUTURE USE
+ r OF Vl COMPUTER SYSTEM
i ! WALL STATION.
i
s � �
c I s
I
i ' SINGLE DATA /SINGLE
VOICE OUTLET
DUPLEX RECEPTACLE -
o I ;NOF41AL POWER 20 AMP
AT IS' AFF.
iI 4" VINYL BASE -1
SPACER —
TRACKS:
SEE SPEC'S
UNDERSIDE OF
EXISTING STRUCTURE
CEILING SUSPENSION
SYSTEM TO UNDERSIDE
OF STRJCT.
SUSPENDED ACOUSTICAL
CEILING TILE: SEE
CEILING PLAN AND SPECS
FOR TYPE
FLOOR
SURFACE MOUNTED GUARD
AT FULL HEIGHT ELEVATION.
CORNER GUARD DETAIL BACKING DETAIL FOR FUTURE
N.TS. PLUMBING -s FIXTURE BACKING DETAIL N -T -5- S WALL CABINET BACKING DETAIL N.T.S. 9 ,,, A, , ,.,,,,,tom, ,t�� "T� 10 TYPICAL CURTAIN TRACK DETAIL N.T.S.
3%' METAL
STUDS A 16'
O.G. (TYP.
EXISTING CONCRETE SLAB
5/8' TYPE 'X' GYPSUM
WALLBOARD - FINISH
AS SHOWN IN ROOM
FINISH SCHEDULE
CORNER BEAD
CONTINUOUS
FOR WALL FINISH
SEE FINISH SCHEDULE
CAULKING CONTINUOUS
VINYL BASE
114' (MIN.) TILE
BACKER BOARD
`r VDENSSHIELD'
OR EQUAL)
EPDXY FLOORING -
SECONDARY CONTAIMENT
SYSTEM BY 'DEX- O -TEX'
RESISTANT TO:
/ / ///
BACKING /COVE STICK AS
PER MANUFACTURER'S
SPECIFICATIONS (TYP.)
FINISHED FLOOR - SEE
ROOM FINISH SCHEDULE
FOR TYPE AND INTERIOR
DESIGN SPECS FOR
ADDITIONAL INFORMATION
K 11) INTEGRATED BASE COVE DETAIL N'TS 12) BASE DETAIL N.T.S.
HARDWARE SC1
CABINET DETAILS
PROVIDE SGHLAGE D SERIES LEVERS -6 PIN -E- KEYWAY
OWNER WILL PROVIDE FINAL KEYING LEVERS - RHODES
GROUP ": I DOOR 0. 100
GROUP 0. 5
DOOR 0. 108
BACKSPLASH.
PROVIDE EACH SINGLE DOOR(S) WITH THE FOLLOWING:
FINISH WALL OR
PROVIDE EACH
SINGLE DOOR(S) WITH THE FOLLOWING:
CAULKING
QUANTITY DESCRIPTION MODEL NUMBER
FINISH
MFR
QUANTITY
DESCRIPTION MODEL NUMBER
FINISH
MFG?
3 EA HINGES 5B5I 45 x 45
652
IVE
3 EA
HINGE 5BBI 45 x 45
652
IVE
I EA OFFICE LOCK ND50P0 RHO
626
SCH
1 EA
STOREROOM LOCKSET ND80PD
626
SCH
1 EA SURFACE CLOSER 4041
689
LCN
I EA
SURFACE CLOSER 4041
689
LCN
1 EA WALL STOP W5401CVX
630
IVE
1 EA
WALL STOP W5401CVX
630
IVE
3 EA SILENCERS SR64
GRY
IVE
1 EA
SILENCER SR(o4
GRY
IVE
1 EA KICKPLATE KP50 10' x 46
U5320
MC
i EA
KICKPLATE KP50 10' x 34'
U532D
MG
GROUP "- 2 DOOR 0. 101, 104
3/4' PLYWOOD D CKING
CORIAN
LAMINATE FINISH
PROVIDE EACH SINGLE DOOR(S) WITH THE FOLLOWING:
AND SPLASH WIT PLASTIC
BULLNOSE
I I
C
QUANTITY DESCRIPTION MODEL NUMBER
FINISH
MFR
3/4' PLYWOOD
518' PLYWOOD PAGING
_
3 EA HINGES 55BIHW 5 x 41/2
652
IVE
TOP
I I N
WITH PLASTIC
I EA CLASSROOM ND50PD RHO
626
SCH
�— SINK (SEE
I EA KICKPLATE KP 50 10' x 46'
US32D
MG
I/4' HARDWOOD
I
LAMINATE FINISH.
PLUMB.
I EA WALL STOP W5401CCV
U532D
IVE
Q
DRWGS.)
3 EA SILENCER SR64
GRY
IVE
BACKING.
>
J
GROUP M: 3 DOOR 0. 105,105A
N
^ FINISH.
d
PROVIDE EACH SINGLE DOOR(S) WITH THE FOLLOWING:
w
I I
i 8' MIN
QUANTITY DESCRIPTION MODEL NUMBER
FINISH
MFR
Ir
1 EA OFFICE LOCK N050PD RHO
626
SCH
3/ PL OD
O
3/4' ADJUSTABLE
/ INSULATE
GROUP M% 4 DOOR "- 106
w
ENDS•
I I
13' W
PLYWOOD SHELF
1 DRAIN PIPE t
PROVIDE EACH SINGLE DOOR(S) WITH THE FOLLOWING:
z
wlTlwi�TX Q�F SOUTH MI
HOT WATER LINE
QUANTITY DESCRIPTION MODEL NUMBER
IF NISH
MFR
N.
I EA STOREROOM LOCK ND80PD (08)/RHO
626
SCH
•
w
LAMINARMLE11ING DEPT.
MIAMI -DADE COUNTY
FIRE DEPAICTMENT
Mi
r:
Revisions:
A05 -01 -14 AHCA
COMMENTS
L�
z �
A�
<0
Imo
wx
�z
z
W
0
V
Lo
Z a
h
I4
O
a4
19
O
elf C
I
CQ -w 1 14
w
O
Cod
�..�
W
AA
V
zo
V z
Q
-j �..�
V �
PERMIT SET
08/01/14
DRAW% GAG
CHECKED: LEN
DATES 01 -29 -14
sCAm AS SHOUJN
E..F4 phi
U.�:-
'Sa 4 ��1 963 1 -
Sheet No.
A -5
OF
8
JOB f 201426
CABINET DETAILS
FINISH WALL OR
BACKSPLASH.
FINISH WALL OR
CAULKING
BACKSPLASH.
SLANTED TOP
(TYPICAL)
.
W/. 5/8' PLYWOOD
CAULKING
FACING AND PLASTIC
FINISH STRIP (METAL)
(TYPICAL).
LAMINATE FINISH.
2. -I' (TYP. UATL)
FINISH STRIP (METAL).
2'-I' (TYP. U ON.)
3/4' PLYWOOD DECKING
CORIAN
—I
AND SPLASH WITH PLASTIC
BULLNOSE
3/4' PLYWOOD D CKING
CORIAN
LAMINATE FINISH
EDGE.
AND SPLASH WIT PLASTIC
BULLNOSE
I I
C
LAMINATE FINISH.
EDGE.
3/4' PLYWOOD
518' PLYWOOD PAGING
_
TOP
I I N
WITH PLASTIC
�— SINK (SEE
— 5/8' PLYWOOD
I/4' HARDWOOD
I
LAMINATE FINISH.
PLUMB.
FACING WITH
Q
DRWGS.)
— 5/8' PLYWOOD
PLASTIC LAMINATE
BACKING.
>
J
FACING WITH
N
^ FINISH.
d
PLASTIC LAMINATE
w
I I
i 8' MIN
FINISH.
Ir
r
Q
r-
Q
3/ PL OD
O
3/4' ADJUSTABLE
/ INSULATE
w
ENDS•
I I
13' W
PLYWOOD SHELF
1 DRAIN PIPE t
z
wlTlwi�TX Q�F SOUTH MI
HOT WATER LINE
w
w
N.
K
a
•
w
LAMINARMLE11ING DEPT.
LINE BORING WITH
CLEAR
I
SCHEDULED
9
w
�
CHROME PIN (TYP.)
N
FINISH WALL. N
c4
FINHSHDWALLD
z
L J
$ TI
z
_ _
HARDSJM91WAL
6' SCHEDULED
SCHEDULED FL R w
w
SPECS) TYPICAL.
MAX FLOOR AND
AND BASE. dwi
dwi
(16' a PATIENT p
- '
BASE.
3/4' PLYWOOD
CUBICLES)
,Ippm7mcc BY.
BOTTOM.
15' r ul
(TYP. U.ON.) ?
Q
w
l
f�
+�
w BACKSPLASH (SEE
INTERIOR ELEVJ.
N.T.S.
N.TS.
N.T.S.
CABINET GENERAL NOTES
1. WHERE CABINET END ABUTS A WALL, PROVIDE BACKSPLASH, 4' HIGH UNLESS OTHERWISE
NOTED ON INTERIOR ELEVATIONS.
ONLY
FINISH WALL OR BACKSR"
INTERIOR MODIFICATIONS
2. BACKSPLASH AND COUNTERTOP ARE CONTINUOUS AS SHOWN ON INTERIOR ELEVATION
(ANY EXTERIOR MODIFICATION MAY REQUIRE
3. PROVIDE CONTINUOUS SEALANT ALONG TOP OF BACKSPLASH AT WALL.
3/4' PLYWOOD DECKWI
r: iOA:ZD A °i EAI:A \CE)
4. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AT FIELD. COORDINATE ALL
FINISH STRIP (METAL)
AND `PL `4 VM PLASTIC
EQUIPMENT INSTALLED IN CABINETS, AND SUBMIT SHOP DRAWINGS TO ARCHITECT FOR
LAMNATE FINISH
APPROVAL PRIOR TO FABRICATION.
2' -I' (T1'P. UAN
Comm
5. REFER TO 1/4' FLOOR PLANS AND INTERIOR ELEVATIONS FOR MODIFICATIONS.
BULLNOSE
6. ARCHITECT/ INTERIOR DESIGNER TO SELECT COLOR OF ALL CABINET FINISHES.
EDGE'
-1. NOT USED.
BAGKSPLASH.
8. ALL INTERIOR CABINET FINISHES TO HAVE PLASTIC LINERS (TYPICAL, UNLESS
OTHERWISE NOTED.)
3/4' x 1 1/2' SPRUCE
S
9. REFER TO INTERIOR ELEVATIONS FOR INDICATION OF LOCKABLE OR NON - LOCKABLE
FRAME (TYP.) DRS
FEATURES. REFER TO SPECIFICATIONS FOR MATERIALS, LOCKS AND HARDWARE.
7i
10. NO CABINETS ARE TO BE SUPPORTED OR HUNG FROM ANY FIRE RATED PARTITION.
HARDWARE (SEE
CABINETS WILL BE HUNG FROM THE SOFFIT ABOVE OR SUPPORTED BY ADJACENT NON-
SPECS) TYPICAL
RATED PARTITIONS. SEE FLOOR PLANS FOR EXACT LOCATION OF FIRE RATED PARTITIONS.
DRAWERS
9
11. PROVIDE EASED COMER EDGES AT ALL CABINET TOPS NOT ABUTTING A WALL.
I/4' PLYwOOD.`'
u' 5/8' PLYWOOD
12. ALL CABINETS ARE TO BE CONSTRUCTED OF GRADE 'A' PLYWOOD AND ARE TO BE
FACING WITH
w
FASTENED TOGETHER WITH SCREWS.
'tutu PLASTIC LAMINATE
FINISH
13. ALL COUNTERTOPS CONNECTED TO WALLS MUST EITHER BE SUPPORTED BY A BASE
DRAWERS
tu
uli
CABINET OR A FULL LENGTH LEG SUPPORT.
— — 3/4' PLY¢D.
14. MILLWORK MANUFACTURER SHALL INSTALL ONE PLASTIC GROMMET PER EACH
(TYPICAL)
ELECTRICAL RECEPTACLE, TELEPHONE OUTLET, CRT OUTLET, ECT. SPECIFIED ON THE
EQUIPMENT PLANS AND/ OR ELECTRICAL DRAWINGS. INSTALL WITHIN THE KNEE SPACE
OF ALL CABINETS SHOWN ON EQUIPMENT DRAWINGS.
DC4 MOOD —r
15. GENERAL CONTRACTOR SHALL COORDINATE ANY NECESSARY ACCESS REQUIREMENTS
IN CABINETRY. ACCESS DOORS AND /OR ACCESS PANELS SHALL BE INCLUDED AS PART
OF THE CABINET WORK WHEN NECESSARY TO INSTALL AND /OR SERVICE ANY TYPE OF
MECHANICAL, PLUMBING OR ELECTRICAL DEVICE THAT IS CONCEALED BY THE CABINETRY.
16. STEEL STUDS SUPPORTING HUNG FIXTURE AND CABINETS SHALL BE DOUBLE OR 20
GAUGE AS PER FBC 2010 A HORIZONTAL MEMBER FASTENED TO NO LESS THAN 2 STUDS
SHALL BE PROVIDED AT WALL HUNG CABINETS AS PER F.B.G. 2010
N.T.S.
MIAMI -DADE COUNTY
FIRE DEPAICTMENT
Mi
r:
Revisions:
A05 -01 -14 AHCA
COMMENTS
L�
z �
A�
<0
Imo
wx
�z
z
W
0
V
Lo
Z a
h
I4
O
a4
19
O
elf C
I
CQ -w 1 14
w
O
Cod
�..�
W
AA
V
zo
V z
Q
-j �..�
V �
PERMIT SET
08/01/14
DRAW% GAG
CHECKED: LEN
DATES 01 -29 -14
sCAm AS SHOUJN
E..F4 phi
U.�:-
'Sa 4 ��1 963 1 -
Sheet No.
A -5
OF
8
JOB f 201426